| 1 | Fabricating, supplying and erection of 3 meter Tubular electrical street light pole, GI with pure polyster powder coated Base plate 200 X 200 X 8 mm thick, Bottom pipe 114 od x 3 mm thik x 1 mtr long , top pipe 76 od x 2.5 mm thk x 2 mtr long , inbuilt junction box, adjustable arm fitting(as per attached Fig 2A) for light, (As perattached design), mcb connectors etc GI M16 X 450 Foundation Bolt & Nut Assembly IS 2062 for base plate with door opening arrangements, including suitable boards, banana connectors, Bakelite sheet, door, hinges for keeping the MCBs, and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s forPole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm, top.mm with 3 mm thick, suitable base plate and 4Nos of long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended. (The pole should be as per the image (Fig 02,02A) attached) including transportation, labor, painting, tools etc. Make: Bajaj / Suncity / as recommended by Engineer incharge |
| 2 | Fabricating, supplying and erection of 6000mm Double Arm Decorative Pole made of CI casting sections of Bottom Dia with 407 approx. 16 mm thickness. The bottom CI base will be 1200mm in height, including the Base top Casting. Above the base CI pipe of 110 dia with a spiral Floral or leaf design with an approx. height of 735mm for each CI section. The pole shall also be provided with a designed CI bracket with a span of 900mm. The bracket stem height with 1500mm, CI Top with 280 mm height to cover the bracket stem and to give an aesthetic look to the pole. The pole shall be properly cleaned, machine-polished, and coated with an epoxy zinc-rich penetrating primer, finished with a polyurethane base paint for a long-lasting finish, featuring a 45-micron coat and an additional Glossy lacquer coat. The total paint coating would be 120 microns. A Junction provision shall be provided and the base casting for Loop in Loop out connector mounted on an appropriate size Bakelite sheet with stud terminals along with 1 no. 6A SP MCB (ABB, simens, L&T, legrand make) to be provided with each pole. The Pole shall be packed with shrink wrapping along with bubble paper wrap to avoid scratches during transportation C installation. The Poles shall be supplied with foundation bolts M16 X 600mm made up of mild steel and threaded portion to be hot dip galvanized, along with 2 nuts C 1 vicer per bolt. Factory test reports, along with Test certificates of material to be attached along with the supply. The Pole shall withstand the wind speed of 75KMPH as per IS 875. door, hinges for keeping the MCBs, with suitable base plate and 4Nos of long J bolts along with template (excluding foundation) as per drawing appended. (The pole should be as per the image Fig 1,1A attached) including transportation, labor, hydra, tools, painting etc. Make: Bajaj / Suncity / as recommended by Engineer incharge |
| 3 | Supplying, and fixing of Single Arm Bracket with 1000 mm Standard 40/50 mm dia Hot dip Galvanized M.S. Bracket suitable for out door luminaries and mounted on above said pole using necessary bolts, nuts etc., complete. (Fig 2A) |
| 4 | Supplying of 4 core 16sqmm 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. Make: Finolx, Havells, Polycab, Glostar. |
| 5 | Earth work excavation In all kinds of soils. Depth upto 1.50m for pipelines / cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, dammering on surface, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. |
| 6 | Providing and installing at site of work P.V.C. pipes 6 Kg/m2: 63mm including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. |
| 7 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff In existing Trench (2.5 to 25 sqmm) |
| 8 | Supplying and terminating of 16 sqmm tinned Alluminium lugs ( 8 nos each pole X 40 poles) and crimping and wiring to terminal point forwire of following sizes Make: Braco, MIC, Dowells, Jaison |
| 9 | Dismantling of existing 5 to 7mtr long street light pole/RCC pole with foundation, brackets, and fittings using mechanical/manual means, filling mud on pit and transporting/stacking it in the place as suggested by the Engineer In charge |
| 10 | Dismantling of existing foot path street light pole concrete foundation (appx 50 numbers), cables, pipes and fittings using mechanical/manual means, filling mud on pit and transporting/stacking it in the place as suggested by the Engineer In charge in the path 1 & 2. |
| 11 | Supplying and drawing 3C x 2.5 mm2 Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS8130-1984 and(Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 |
| 12 | Supplying & Fixing Chemical earthling Using 6ft. Copper bonded rod with backfill compound for grounding. Conduits, ICcutouts & other equipmentsbackfill compound which is non corrosive, thermally conductive, potential to permissiblelimits,superiorFaultconductioncapacity,nontoxic,weatherresistance&capable of achieving ohmic value less than one ohm and welding works, CC chamber of 400 x400x400 mm with a cast iron cover and naming of pits, etc (Authorisation certificate &test certificates should be submitted if needed) Using 6ft. Copper bonded rod with backfill compound For each 5 poles (8 locations) |
| 13 | Supply and fixing of LED Streetlight 100W luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency>1301m/w, nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 5 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. Note: Comprehensive warranty of 5 years including removing of faulty fittings and refixing of repaired/new fittings using necessary scaffoldings/sky lift etc within 5 days from the date of complaint. Failing which necessary deduction will be made in the security deposit amount. Make: Philips/Bajaj/Havells/Jaguar |
| 14 | Supply and fixing of LED Streetlight 40W luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti-glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency>1301m/w, nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 5 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds /Osram make LED Source. Note: Comprehensive warranty of 5 years including removing of faulty fittings and refixing of repaired/new fittings using necessary scaffoldings/skylift etc within 5 days from the date of complaint. Failing which necessary deduction will be made in the security deposit amount.Make: Philips/Bajaj/Havells/Jaguar |
| 15 | Wiring for lighting/power circuit using 1 run X 4 sq.mm PVC insulated 1100V grade multistrand copper conductor single core cable in open or concealed system of wiring. Make: Finolex, Havels, Anchor, RR cable |
| 16 | Supplying and fixing of 25 mm heavy duty cable glands suitable for UG cable of 1.1 KV class for cable termination (40 poles x 2 No’s on each pole) |
| 17 | Cutting of Tar Road surface for cable trenches and disposing of the excavated earth, as directed including Barricading, Danger Lighting then Refilling the Cable Trenches and cement concreting on top layer/dammering |
| 18 | Supplying and making 4 C x (16) Sq mm Heat shrinkable type Straight Through Jointing Kits Suitable for 1.1 kV Class LTUG Cable as per IS-13573. Make: Reychem, MIC,3M |
| 19 | Supply and Installation / Fixing / Provision of Pole box with HRC Fuse / MCB provision and suitable connector / terminal for 3 Ph/ 1 Ph connections with Loop-In & Loop- Out terminals for 10 mm2 /25 mm2 3.5 C AI/Ar/Cu/Ar Cable and branch out 2.5 mm2 2 core AI/Cu PVC Insulated cable, enclosed in a Thermoplastic, Polystyrene enclosure, which should be shock proof, safe, IP65(Weather Proof), rust proof, dust proof, water proof having Internally Embedded Gasket withprovisionforcableentrythroughIP65Thermoplastic, polyamide glands and/or grommets. 260mmX210mmX116mm |
| 20 | Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.) 3-120sec setting. |
| 21 | Supplying & fixing 10 Amp SP miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and \"C\" Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. |
| 22 | Supplying & fixing 32 Amp TPN miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and \"C\" Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. |
| 23 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. |
| 24 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates |
| 25 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. |
| 26 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including shuttering,lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications : M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates |
| 27 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. |
| 28 | Providing and applying two coat of exterior paint of Apex having anti fungus and water resistance character of approved colour and shade over a base coat of asian primer including removing existing white wash/ colour wash by steel brushing/scraping, providing scaffolding, filling of cracks with putty where necessary complete. with primer. |