}

Tender For Electrical, Data Cabling And Air Conditioning Works Of Union Bank Of India Madurai V K Street Branch, MADURAI-Tamil Nadu

Tender Notice

51866774
Tender For Electrical, Data Cabling And Air Conditioning Works Of Union Bank Of India Madurai V K Street Branch
Tender
Indian
Tamil Nadu
Madurai
31-10-2025

Tender Details

Tender For Electrical, Data Cabling And Air Conditioning Works Of Union Bank Of India Madurai V K Street Branch Supply and laying of following size of original (Approved make )PVC insulated copper wire in suitable PVC conduit of 2mm thk with necessary PVC accessories like elbows, bends etc, necessary clampings a 4 x 6 sqmm + 1 x 4 sqmm from Main MCB DB to UPS input cost of 4 x 6sqmm wire & } 1 x 4 sqmm wire } Cost of PVC conduit pipes} 25 /M Laying/fixing charges } b BM cabin one AC machine Cost of 2 x 4 sqmm wire 1 x 1.5 sqmm wire Cost of PVC conduit pipes 40 /M Laying/fixing charges c Banking Hall 6 AC machine Cost of 2 x 4 sqmm wire } 1 x 1.5 sqmm wire Cost of PVC conduit pipes 200 /M Laying/fixing charges d 2 x 4 sqmm + 1 x 2.5 sqmm from UPS output to UPS output main MCB DB & UPS output circuits DBs Cost of 2 x 4 sqmm wire & } 1 x 2.5 sqmm wire } 25 /M Cost of PVC conduit pipes } Laying/fixing charges } e 3 x 2.5 sqmm from UPS output to circuit DBs to UPS points (Four circuits) Cost of 3 x 2.5 sqmm wire & } Cost of PVC conduit pipes ) Laying charges } 490 /M (UPS & RAW POWER CIRCUIT) 2a Supply and fixing of 2 x 4 sq.mm and 1 x 2.5 sq.mm (Approved make ) copper wire in PVC conduit of 2mm thk from change over switch to generator point 40 /M b Supply and fixing of 15 A switch plug and socket with suitable surface mounted box. (Approved make ) 8 /No 3a Supply and laying for 3.5 X 50 sq.mm aluminium armoured cable for EB meter to Main DB 50 /M b Supply & fixing of (Approved make) following 8way 3phase vertical type double door MCCB DBs in suitable MS enclosures with necessary interconnection main MCCB DB MS Enclosures -1No 1 /No 100Amps MCCB -1No 1 /No 63Amps 3pole MCB -4Nos 4 /No SP 40Amps MCB -12Nos 12 /No c UPS INPUT MAIN MCB DB (Approved make )with MS enclosure 1 /set 63Amps 4pole MCB d UPS OUTPUT MAIN MCB DB (Approved make ) Double door single phase 8way with MS enclosure -1 40Amps 2pole MCB -1 2 /set SP 10 Amps MCB -6 e Supply & fixing of (Approved make) following 8way three phase vertical type double door MCB DBs in suitable MS enclosures with necessary interconnection main MCB DB for lighting MS Enclosures 1 /No 63 Amps 4 pole MCB 1 /No SP 25 Amps MCB 12 /No 4a Change over with phase shifter Supply & Installation of 63Amps 4 pole change over switch for generator - (Approved make ) 1 /No b Supply & providing of 3 Phase indicating lamps (3Nos) in suitable box 1 /set c Supply & fixing of 63Amps Auto Phase Selector switch for UPS Input 1 /set (Approved make ) d Supply and laying of 2pair Telephone cable (Approved make )suitable PVC pipe/channel 390 /M cost of cable cost of PVC pipe Laying charges e Supply & installation/fixing of Modular type RJ11 Telephone sockets(Approved make ) 10 /No f Supply & installation/fixing of 20 pair krone box with Connectors including Temination Charges 1 /set 5a Supply, installation and testing of dedicated earth pit for UPS as per standard using 600mm x 600mm x 3mm copper thick. The rate should include excavation, salt and charcoal powder, brick work 450mm x 450mm, cast iron cover/plate etc of & providing of copper plate ear thing as per standard for dedicated earth pit for UPS 1 /set b Supply & laying of 6sqmm copper wire within 20mm GI pipe from earth electrodes to the UPS 55 /M 6a Supply & fixing of 3Nos 6amp socket with 2Nos.6amp switch in suitable surface mounted box. -UPS Power (Approved make ) 17 /No b Supply & fixing of 1Nos 6amp socket with 1Nos.6amp switch in suitable surface mounted box for Wall Fan and Officer Table. - (Approved make ) 25 /No c Supply & fixing of 2Nos 6amp socket with 1Nos.15amp switch in suitable box for Raw Power-Modular type- (Approved make ) 10 /No 7a Supply and fixing of original 4 x 4 sq.mm + 1 x 2.5 sqmm copper wire in PVC conduit of 2mm thick from Main MCB DB to generator change over and from changeover to lighting board 50 /M b Supply and fixing 20A Metal clad plug and socket for AC unit 8 /No 8 Point wiring: Point wiring for light,fan, 6A switched sockets with (Approved make) 2R 1.5 Sqmm FRLS insulated multi strand single core copper conductor wire drawn in 20mm dia 2mm thick PVC conduit to be laid on false ceiling by clamping with GI clamps, concealed on wall and RCC roof etc with all accessories like conduit bends, junction boxes etc. The work also involves supply and fixing of 6A modular switch housed in manufacture’s zinc passivated MS box to be concealed to wall. a One light point controlled by one switch 55 /No b Two light controlled by one switch 10 /No c Fan point with fan hook 6 /No d 6A switch box sockets in the switch board itself 8 /No e Supply and fixing of Calling bell with switch including Connection Charges, etc., complete. 1 /No f Supply and installation of 2R 2.5 Sqmm FRLS multi strand copper wire drwn in 20mm PVC conduit 2mm thick to be laid concealed on wall between DBs and switch boxes including terminations at both ends (UPS & RAW POWER CIRCUIT) Supply of commercial Recess mounted 36W LED luminates comprises of CRCA housing powder coated in white the LED cluster are PMMA diffuser uniform glare-free light distribution suitable for 600mmx600mm coiling and operating voltage 240V input current 0.140 – 0.160 AMP input wattage 33-37W 16 /No b Supply of ISW LED Recess mounted down lighter comprises of aluminium dia cast housing and ring finished white powder coated with high translucent frosted PMMA diffuser operation voltage 240V input current 0.06-0.075 AMP input wattage 14.5-15.5W 33 / No c 1 X 28 With Patti Light Fixture. 14 / No d 48” Ceiling Fan of Approved make. 5 / No e Supply & fixing of Blue colour LED FLEXI Strip Light fittings in the stepped false ceiling area including the cost of wiring etc., complete. 70 /m f Battern Holder with 11 Watts CFL Retrofit. 3 /No g Pedestal Fan Approved make. (Almonard 16) 10 / No h Exhaust Fan Approved make. 4 / No 10 CCTV, FIRE & BURGLAR ALARM WIRING: PVC FRLS conduit to be clamped to ceiling / wall and not to be run over false ceiling or partitions. a Supply and laying 3-in-1 video & power cable for CCTV cameras in 20mm dia. 1.6to1.8mm thick medium class PVC FRLS conduit clamped in wall /ceiling with GI saddle clamps, base, screws, etc. b Supplying & laying of 2 X 1.5 Sq.mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath laid in the ceiling with all necessary accessories viz., GI saddle clamps with base, screws, glands etc. c Supply and laying 2 runs of 14/36 SWG PVC insulated twisted copper wires in20mm dia. medium class PVC FRLS conduits with GI saddle clamps with base,screws, glands etc., 11 Removing and Clearing the existing electrical wiring and switch box,Dbs,fan,light fittings etc., and providing for temporary arrangement lights,fan,ups points for cash,running counters,officer tables branch functioning 1 /set TOTAL (I) (inclusive of all taxes and expenses & GST etc.,)

Key Value

Document Fees
Refer document
Tender Value
INR 12.71 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail