Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | HSR 5.7.4 Demolishing brick work manually/ by mechanical means including stacking of serviceable material anddisposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 2 | HSR 5.11 Demolishing mud phaska in terracing and disposal of material within 50 metres lead. |
| 3 | HSR 5.14 Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead |
| 4 | HSR 5.29.1 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below |
| 5 | HSR 5.43.1 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm |
| 6 | HSR 5.44 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 7 | HSR 5.23.2 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:2:4 or leaner mix (i/c equivalent design mix) |
| 8 | HSR 5.45 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 9 | HSR 5.48 Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 10 | HSR 5.54.3 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 150 mm dia pipe |
| 11 | HSR 5.55.1 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : |
| 12 | HSR 5.56.2 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes and lead at site within 50 metre lead as per direction of Engineer-in-charge: Above 150 mm dia up to 300 mm dia |
| 13 | HSR 5.63 Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 14 | HSR 3.1.18 Shifting of malba |
| 15 | HSR 4.7.1.1 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth and lift up to 1.5 m, as directed by Engineer-in- Charge: 1.1 All kinds of soil 50m lead |
| 16 | HSR 4.16.1.2Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 17 | HSR 4.38.1 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 18 | HSR 6.1.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 19 | HSR 6.16 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 20 | HSR 6.30.4 Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ) |
| 21 | HSR 6.33.6 Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 22 | HSR 7.22.2 Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 4 coarse sand) |
| 23 | HSR 11.5.3 12 mm cement plaster of mix : 1 :4 (1 cement: 4 fine sand) |
| 24 | HSR 7.28.2Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level |
| 25 | HSR 12.158.2 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.Pre-laminated particle board with decorative lamination on both sides |
| 26 | HSR 12.157.1.2 Aluminium For fixed portion. Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 27 | HSR 12.157.2.2 Aluminium For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 28 | HSR 8.32 ALUMINIUM COMPOSITE PANELS |
| 29 | HSR 12.159.2 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 30 | HSR 12.160.1 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight up to 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness |
| 31 | HSR 12.164 Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 32 | HSR 12.171 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top and bottom pivot and double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in charge (Door handle, lock and stopper etc.to be paid separately). |
| 33 | HSR 12.97.1 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:125x75x4 mm |
| 34 | HSR 12.98.1 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm |
| 35 | HSR 12.99.3 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10 mm |
| 36 | HSR 12.99.5 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100x10 mm |
| 37 | HSR 12.102.1 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
| 38 | HSR 12.102.2 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :100 mm |
| 39 | HSR 10.73 Providing and fixing ceramic and Glazed tiles/ vitrified tiles/ of any size of approved make in floors / dados, laid in any pattern as specified over base of 3 mm thick adhesive of reputed brands as per IS specification 15477-2004 using 5 Kg. adhesive per sqm area of tiles and jointed with white cement slurry mixed with pigment to match the shade of tiles excluding cost of tiles.(The size of tile required upto 8\" x 4\") |
| 40 | HSR 10.70.3 Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 41 | NS Providing and laying industrial grade epoxy flooring system over prepared concrete surface, including mechanical hacking/grinding to remove laitance and contaminants, vaccum cleaning, and surface preparation to achieve proper adhesion. The system shall consist of :Pimer Coat: Two compoinent low viscosity epoxy resin and polyamide harnener, solvent free, applied @ 0.2 kg/sqmBase Coat: Epoxy resin blended with graded quartz/silica filler (ratio 1:4 by weight) forming a self leveling mortar, applied to 1.5mm -2mm thicknss.Top Coat: High performance, 100% solids epoxy resin + amine hardener, pigmented and UV-resistant, applied to 0.5mm - 1mm thickness, giving smooth, glossy, chemical and abrasion resistant finish.The cured flooring shall have:Bond strength > 1.5 N/sqmmHardness shore D > 80Abrasion resistance < 2mm lossChemical resistance > Resistant to mild acids, alkalis, oils, and solvents. |
| 42 | NS Providing and fixing of puff panel wall 80mm thick (Isolloyd & Jindal /equivalent reputed brand as approved by engineer-in-charge) with 8 mm thick double walled glass window (24\" x 2.5\") and 2 doors of size 3.25\" x 7\" each including all Accessories (Inner Flashing/Outer Flashing/ U channel) with Silicon & Pop Rivet & gitti, complete in all aspects as per directions of engineer in charge. |
| 43 | HSR 10.37.1 Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick |
| 44 | HSR 10.38 Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 45 | HSR nan Providing and laying of acid/alkali proof Mandana stone of required size upto maximum of 600 mm x 60 mm of thicness 25 mm to 40 mm and that for skirting and dado shall be 15 mm to 20 mm. The size of stone shall depend on drainage system laid over the bed of cement mortar of thickness 25 mm to 40 mm keeping 6 mm to 10 mm joint all around for all the stones which should be filled with high quality epoxy resin. The joints shall be racked 12 mm to 19 mm deep and the same should be filled with expoxy resin compound. The entire floor shall be machine or hand rubbed, polished, cleaned with exalic acid upto the satisfaction of engineer-in-charge. |
| 46 | HSR 8.29 Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. |
| 47 | HSR 10.58 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete |
| 48 | HSR 10.61 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding pointing the joints with white cement and matching pigments etc., complete |
| 49 | HSR 10.98 Providing and fixing Grass paver block of required strength and thickness on 25 mm thick compacted bed ofsand and filling the joint with sand complete in all respect |
| 50 | HSR 10.99 Providing and fixing covel stone/garden stone of size 150 mm x 150 mm laid in 20 mm thick cement mortar 1:3 including grouting the joint with white cement and matching pigment complete in all respect (Covel/Garden stone to be as per manufacturer`s specifications to be got approved from Engineer-in-charge) |
| 51 | HSR 17.69.2 Providing and Laying 80 mm thick ISI marked Interlocking Paver Blocks conforming to IS 15658:2006/IRC SP 63: 2004 of all shapes and colours in design mix cement M 40 over the bed of 30 mm thick fine sand complete in all respect. |
| 52 | HSR 10.100.2 Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth. |
| 53 | HSR 8.16 Providing and fixing of reconstituted stone tile work (IS 3622-2017-Reaffirmed) for wall Cladding up to 10 m height with special adhesive (IS 15477-2019) over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade. |
| 54 | HSR 9.11 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1 With common burnt clay non-modular brick tile of class designation 10 |
| 55 | HSR 11.26.1 Pointing on tile brick work with cement mortar 1:3 (1 cement : 3 fine sand):Flush/ Ruled/ Struck or weathered pointing |
| 56 | HSR 19.53 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase |
| 57 | HSR 9.18 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 58 | HSR 13.29.2 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 59 | HSR 11.73.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer`s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work |
| 60 | HSR 30.22 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 61 | HSR 11.60\" Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 62 | HSR 11.67.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer |
| 63 | HSR 11.95.1 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm |
| 64 | HSR 11.123 Wall painting with (bio grade)plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) Generally used in hospital buildings etc. complete as per Specifications. |
| 65 | HSR 11.94.1 Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 litre/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 66 | HSR 22.2.1 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White vitreous chinaware Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 67 | HSR 22.5 Providing and fixing white vitreous chinaware pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 68 | HSR 22.10.2.1 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x510 mm bowl depth 200 mm |
| 69 | HSR 22.14.1.2 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe, 40 mm dia |
| 70 | HSR 22.17.2 Providing and fixing 40mm i/d chromium plated trap with chromium plated pipe to wall with walflange completed for use with sinks |
| 71 | HSR 22.20.2 Providing and fixing in position C.I. plain Nahani Trap conforming to I.S.I. specifications and of self cleaning design with C.P. brass hinged grating with frame complete, With 75 mm internal diameter outlet |
| 72 | HSR 22.23.1 Providing and fixing white vitreous chinaware pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 73 | HSR 22.38 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. |
| 74 | HSR 22.42.1 Providing and fixing toilet paper holder : 1 C.P. brass |
| 75 | HSR 22.82.1 Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay non-modular bricks |
| 76 | HSR 22.83 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 77 | HSR 22.84 Making hole up to 20x20 cm and embedding pipes up to 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) including disposal of malba. |
| 78 | HSR 22.86.3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 25 mm nominal outer dia Pipes |
| 79 | HSR 22.104.1 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore Ea |
| 80 | HSR 22.97.2 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore |
| 81 | HSR 22.101.2.2 Providing and fixing Unplasticised PVC connection pipe with brass unions : 45 cm length 20 mm nominal bore |
| 82 | HSR 22.103.3 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore |
| 83 | HSR 22.105.1 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore |
| 84 | HSR 22.109 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 85 | HSR 22.110.1 Providing and fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology.15 mm nominal bore |
| 86 | HSR 22.117 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 87 | HSR 22.118 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 88 | HSR 22.120\" Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. |
| 89 | HSR 22.121 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 90 | HSR 22.123.2.1 Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating |
| 91 | HSR 22.124.3 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball.25 mm nominal bore, 152mm long, weighing not less than 440 gms |
| 92 | HSR 22.173.1 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay non-modular bricks of class designation 7.5 |
| 93 | HSR 22.174.1 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4(1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside)with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessaryexcavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering withcement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1 With common burnt clay non-modular bricks of class designation 7.5 |
| 94 | HSR 22.181 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and s |
| 95 | HSR 22.209 Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 96 | HSR 22.222.1.1 Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 1.1 Single Socket Type A 160mm o/d SWR UPVC pipe lines laid complete |
| 97 | HSR 9.57.3 Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 150 mm diameter |
| 98 | HSR 9.58.5.3 Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5°150 mm bend |
| 99 | HSR 9.58.3.3 Single tee with door 150x150x150 mm |
| 100 | HSR 9.58.4.3 Single tee without door 150x150x150 mm |
| 101 | HSR 8.26.2.1 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shadeArea of slab over 0.50 sqm |
| 102 | HSR 8.27.2 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in Charge. Granite work |
| 103 | HSR 8.28 Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 104 | HSR 13.41 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 105 | HSR 13.37.2 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover |
| 106 | HSR 13.38 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover |
| 107 | HSR 13.40\" Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured). |
| 108 | HSR 12.130.2 Providing and fixing of casement and fixed windows made from multi chambered UPVC profiles of 56 to 68mm width in natural from stabilized for heat, light, impact & UV radiation The UPVC profiles should be reinforced with galvanized steel profiles of designed thickness. All openable sashes shall be having weather seal fitted in continuous lengths made from Bubble EPOM Rubber and side hung/ top hung with up to 90 degree opening friction stays of SS 304 with provision of multipoint locking system made from Espag rods. All handle shall be made from Die Cast Zinc alloy (Model ESPAG)BS1004A in white finish with suitable locking arrangement. The windows shall be fixed to opening using expandable screws and friction stays that shall be able to with stand wind speeds up to 180 km/hr. the shoot bolts in windows shall be rust proof metallic coated steel. The window frames shall be fixed in masonry wall RCC with necessary fasteners, nuts, bolts, washers, caps, silicon sealant etc. complete |
| 109 | HSR 12.130.3 Double glass glazing comprising of 6 mm thick toughened clear glass+ 12mm air gap+ 5mm annealed clear glass. |
| 110 | HSR 22.88.5 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 40 mm dia nominal bore |
| 111 | HSR 4.12.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. |
| 112 | HSR 6.1.8 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) |
| 113 | HSR 7.21.1 Brick work with common burnt clay non-modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 114 | HSR 11.5.212 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand) |
| 115 | HSR 6.30.3 Suspended floors, roofs, landings, balconies and access platform |
| 116 | HSR 6.14.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 117 | HSR 21.93.1 Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge.. |
| 118 | HSR 21.28 Providing and fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS :1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1:2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge |
| 119 | NS Providing and fixing Acrylic letter without module LED size 4.5\" height inclusive the cost of fitting and wiring complete in all respect as per the direction of Engineer-in-Charge. |
| 120 | NS Providing and fixing Acrylic letter without module LED size 12\" height inclusive the cost of fitting and wiring complete in all respect as per the direction of Engineer-in-Charge. |
| 121 | HSR 6.30.16.1 Edges of slabs |
| 122 | NS Establishing a walk-in-cold room unit of size 15\"6\" x 17\" x 12\" for maintaining room temperature -22℃ having panels of Polyurethane Foam (PUF) density 40 +/- 2 Kg/cubic meter, thickness 120 mm on walls & roof, 100 mm thick on floor, lamination of PP G.I. Sheet on both sides for walls and ceiling along with providing door panels having 120 mm thick PUF, double glass & door heater. The outdoor unit comprising compressor of type hermetic sealed having capacity 5hplt (make bitzer/equivalent reputed brand as approved by engineer-in-charge), R-404A referigerant. The indoor unit evaporator with make guntner equivalent reputed brand as approved by engineer-in-charge. The outdoor and indoor unit both required one stand-by units. The unit comprising digital temperature controller, Accessories (Inner Flashing/Outer Flashing/ U channel) with Silicon & Pop Rivet & gitti), MS stands for condensing units, drain pipe, gas copper pipe cabling upto 6 mtrs. , controller,Contactors Schneider with electrical controls, Wireleep, poliycab cap , Copper pipe Accessories, Ball valve, Drier, Site Glass & Gas Testing, freight, etc. complete in all aspects as per the directions of engineer-in-chage. The cost excludes only wiring from main panel to cold room. |
| 123 | NS Establishing Air Washer Unit of capacity 15000 CFM, overall size 114\" x 74\" x 80 \" with double skin air washer unit, 40 mm Aluminium Section, 25 mm Pannel Puff injected, sheet 0.6 mm outer PPGI (AMNS/equivalent make), inner sheet 0.6 mm GI (JSW/Tata/Equivalent reputed make), water tank made up of SS 304 (JSW/equivalent reputed make) 1 mm thick water tank, 200 mm thick celing pad, PVC alminator, water pump of capacity 1hp (crompton/equivalent reputed make), 10 micron prefilter, Blower fan nicotra/equivalent reputed make, Blower motor of capacity. 7.5 kWof crompton/reputed equivalent make, bases of motor, blower, air washer made up of G.I. 1.2 mm thick. AND Exhaust Unit of Capacity 15000 CFM, overall size 88\" x 68\" x 64\" double skin exhaust unit made up of 40 mm aluminium section, 25 mm Panel puff enjected, sheet 0.6 mm outer PPGI (AMNS/equivalent make), inner sheet 0.6 mm GI (JSW/Tata/Equivalent reputed make) having blower motor of capacity 9.3 kWof crompton/equivalent reputed make, belt driven blower nicotra/reputed equivalent make with unit base of G.I. sheet 1.2 mm thick AND Kitchen HOOD of SS 202 0.8 mm thick sheet of size 4 feet x 2 feet upto 6 pcs. with fitting AND GI Damper of sizer 12 inch x 12 inch upto 12 pcs including fitting with fitting AND Damper with grills ms powder coated 24 inch x 8 inches upto 25 pcs. including fittings AND Electrical panels of Air Washer Unit and Exhaust unit of make ( Switchgear/ L&T/ Reputed Make as approved by Engineer-in-Charge. Complete in all aspects excluding electrical cables. |
| 124 | NS Providing & fabrication of Ducting work for Air washer and Exhaust units with 24 gauge G.I. sheet(JSW/Tata/Equivalent reputed make) including all accessories, nut, bolts, thread rods, etc. complete in all aspects as per directions of engineer-in-charge. |
| 125 | NS Providing & fabrication of Ducting work for Air washer and Exhaust units 22 gauge G.I. sheet (JSW/Tata/Equivalent reputed make) ducting upto 200 sq. ft. areaincluding all accessories, nut, bolts, thread rods, etc. complete in all aspects as per directions of engineer-in-charge. |
| 126 | NS Providing & fabrication of insulation foam XLP 9mm for Air washer and Exhaust units I (safari/equivalent reputed make) upto 800 sq. ft. area including all accessories, nut, bolts, thread rods, etc. complete in all aspects as per directions of engineer-in-charge. |
| 127 | NS Providing, fixing, installing and commissioning of 2 Ton with minimum 3 star rating of BEE Air Conditioners (Split Type) of fixed speed type compressor, complete with Indoor Unit (IDU), Outdoor Unit (ODU), surface/concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 3 mtrs IDU to ODU), copper cable upto 3 mtr. (IDU to ODU), R-32/R-410 refrigerant, PVC drain pipe (dia 15 mm) upto 3 mtr., remote, ODU stand, with all accessories provided by brand manufacturer complete in all aspects. The condenser coil shall be of copper with blue/golden fins. Warranty 1 year from Brand Manufacturer with 5 kVA copper winded stabilizer with working range of 90 V-300V having display showing input/output voltage with all accessories. |
| 128 | NS Providing, fixing, installing and commissioning of 1.5 Ton with minimum 3 star rating of BEE Air Conditioners (Split Type) of fixed speed type compressor, complete with Indoor Unit (IDU), Outdoor Unit (ODU), surface/concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 3 mtrs IDU to ODU), copper cable upto 3 mtr. (IDU to ODU), R-32/R-410 refrigerant, PVC drain pipe (dia 15 mm) upto 3 mtr., remote, ODU stand, with all accessories provided by brand manufacturer complete in all aspects. The condenser coil shall be of copper with blue/golden fins. Warranty 1 year from Brand Manufacturer with 4 kVA copper winded stabilizer with working range of 90 V-300V having display showing input/output voltage with all accessories. |
| 129 | HSR 23.26.4 Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire set 3067 buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6\"x4\" made of GI pipe 32mm dia). |
| 130 | HSR EL257 MS Bucket for fire |
| 131 | NS Supply and Erection of ABC Stored Pressure type Fire Extinguisher 6 Kg. Capacity (5 year warranty) bearing ISI Mark for fire fighting ABC class of fire extinguisher will be manufactured strictly as per BIS IS:683:2006 bearing ISI Mark EN3 615 approved powder Make : -Safex / Minimax / Cease Fire/ Aska Equivalent reputed make as approved by engineer-in-charge |
| 132 | NS Supply and Erection of Watermist and CAF (compressed Air Foam) Low pressure trolley mounted fire extinguisher 50 Ltr. Capacity Make : -Cease Fire/ Aska Equivalent reputed make as approved by engineer-in-charge |
| 133 | NS Supply and Erection of Co2 type Fire Extinguisher 4.5Kgs. Capacity, made from brand new seamless cylinder, as per IS: 7285 and CCE approval, fitted with Dischargehose and horn and Squeeze Grip type valve with initial Charge as per IS: 15683:2006 specification, bearing ISI Mark Make : -Safex / Minimax / Cease/ Aska Fire Equivalent reputed make as approved by engineer-in-charge |
| 134 | NS Establishing RO system including freight and instalation in the factory with all specifications & scope as mentioned in the DNIT complete in all aspects as per directions of engineer-in-charge) |
| 135 | NS Establishing 5 KLD Effluent Treatment Plant with all specifications & scope as mentioned in the DNIT; complete in all aspects as per directions of engineer-in-charge. |
| 136 | NS Design, Supply & erection of transformer of150 kVA of standard make including G.O. switch, Disc Insulators, Pin Insulators H. Pole, entire cable network from G.O. switch to H.T metering equipment and from H.T metering to Transformer. From transformer to main to L.T, earthing, safety equipment, fenced enclosure for transformer, and any other contingent thereto complete in all respect as per approved make and directions of Engineer-in-charge as per respective capacity. |
| 137 | HSR 24.12.70 PROVIDING AND ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITHOUT SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 120 sqmm 3.5 core Main Cable |
| 138 | HSR 23.22.1.11 Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA MCCB |
| 139 | HSR 23.22.2.2 MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 250 A FP |
| 140 | HSR 23.22.4.12 Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work.Vertical TPN DB Double Door 12 way ( 8 incoming 3phase*12 outgoing) |
| 141 | HSR 23.22.5.8 Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCB\"s FOUR POLE |
| 142 | HSR 23.22.5.4 Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCB\"s FOUR POLE |
| 143 | HSR 23.22.5.4 Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Single Pole |
| 144 | HSR 23.22.5.4 Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole |
| 145 | HSR 24.1.4 Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. |
| 146 | HSR 24.1.5 Extra for charcoal or coke and salt for G. I. plate or copper plate earth electrode. |
| 147 | HSR 24.1.10 Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. |
| 148 | HSR 23.5.3 Wiring only in existing conduit and MS Box for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable , without separate |
| 149 | HSR 23.5.2 Wiring only in existing conduit and MS box for Twin control light point with 2 nos , 2-ways, 5 amp. switch in 1.5 sqmm FRLS PVC insulated copper conductor cable . |
| 150 | HSR 23.5.5 Wiring in existing conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling, including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch etc complete as required |
| 151 | HSR 23.5.6.2 Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) |
| 152 | HSR 23.5.6.1 Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1.1.80mm) |
| 153 | HSR 23.5.6.3 Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1.1.80mm) |
| 154 | HSR 23.5.6.4 Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 6 Sqmm(1.1.80mm) |
| 155 | HSR 23.7.6.2 Supply and erection of PVC CONDUIT ISi marked (Medium) recessed in walVceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. |
| 156 | HSR 23.7.6.4 Supply and erection of PVC CONDUIT ISi marked (Medium) recessed in walVceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 40 mm dia. |
| 157 | HSR 23.8.11.1 Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch |
| 158 | HSR 23.8.11.3 15 amp 1 way switch |
| 159 | HSR 23.8.11.4 5 amp Socket |
| 160 | HSR 23.8.11.5 15 amp 6 pin Socket |
| 161 | HSR 23.8.11.7 step type Fan Regulator 2 modules 300 watt |
| 162 | HSR 23.8.11.10 Blanking plate |
| 163 | HSR 23.8.1.5 Ceiling rose flush/surface type |
| 164 | HSR 23.8.10.3 Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 4 Modules |
| 165 | HSR 23.8.10.4 Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 6 Modules |
| 166 | HSR 23.8.10.5 Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 8 Modules |
| 167 | HSR 23.8.10.6 Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 12 Modules |
| 168 | HSR 23.8.10.2 Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 3 Modules |
| 169 | HSR 23.8.4 Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. |
| 170 | HSR 20.72 Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. |
| 171 | HSR 24.14.23 PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 16 Sq mm 4 core (UnArm.) |
| 172 | HSR 24.14.17 PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 10 Sq mm 4 core (UnArm.) |
| 173 | HSR 23.23.7.1 Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. |
| 174 | HSR 24.14.31 PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 25 Sq mm 4 core (UnArm.) |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy