Tender For Infrastructure Work In Berm E-01 And E-03, jodhpur-Rajasthan

Tender Notice

51858784
Tender For Infrastructure Work In Berm E-01 And E-03
Tender
Indian
Rajasthan
Jodhpur
07-11-2025

Tender Details

Tender For Infrastructure Work In Berm E-01 And E-03; 1 Supply and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. 1.1 3x4 sqmm. 600.00 Metre. 206.00 123600.00 2 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2.1 15/16 A switch 55.00 Each 156.00 8580.00 2.2 6 pin 15/16 A socket outlet 55.00 Each 197.00 10835.00 3 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3.1 03 Module (200mmx75mm) 35.00 Each 327.00 11445.00 3.2 8 Module (125mmX125mm) 20.00 Each 454.00 9080.00 4 Supply and fixing of following sizes of medium class PVC conduit/casing capping along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 4.1 25mm 200.00 Meter 145.00 29000.00 4.2 32mm 100.00 Meter 184.00 18400.00 5 Supply and fixing of following ways Horizontal type three pole and neutral MCB distribution board 415V, on surface/recess complete with tinned coper bus bar, neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc as required. (But without MCB/RCCB/isolator) 5.1 4way (4+12), Double door 2.00 Each 4091.00 8182.00 6 Supplying and fixing 5A to 32Amp rating 10kA, C curve MCB breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. 6.1 Single pole 24.00 Each 256.00 6144.00 7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 7.1 4x16sqmm+2x6sqmm earth wire 100.00 Meter 1365.00 136500.00 8 Online UPS- Input supply: Three Phase, Output supply: Three Phase Supplying, installation, Testing & Commissioning of of following capacity at full load (Unity Power Factor) at operating temperature 0 to 40 deg C, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swappable (allow for the replacement or addition of battery modules without shutting down the entire system) modular Power Supply (UPS) system with N+1 modules (N denotes total number of modules required for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch alongwith provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. UPS shall have inbuilt phase sequence correction. The UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for reliable operation using Insulated Gate Bipolar Transistor (IGBT)s both for the rectifier & inverter (3 Level) with PWM (Pulse Width Modulation). The quality of design, manufacturing and inspection process should confirm to the relevant International standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >96% while operating on battery mode and delivering quality power to the 100% non-linear loads. Current total harmonic effect(ITHD) on the input grid shall be < 5% at 50 %load. (The required LC ( inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1), however UPS shall be suitable to take load at 0.7 lagging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC: 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1-meter distance, protections: Input Under voltage over voltage, abnormal out voltage, battery over charging, output over current, short circuit protection, battery deep discharge protection, 10KV surge. UPS must comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. Communication RS232/RS485/SNMP port open protocol for BMS integration, all hardware & software for iOT Communication as per approved by Engineering in charge. Required battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accoseries are inclusive of the cost). This system must provide a means for logging and alarming of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least 80% of the load, Noise Level 65 DB at 1-meter distance. The system shall be in compliance IEC 62040- 1,2 & 3, IS: 16242 and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more LC Display / LED) to display: a) Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current. d) Battery: Voltage, Capacity. e) Load: KVA, KW, Percentage. f) Temperature: STS, Inverter, PFC. g) Event Logging & Statistical Data (On LCD/LED): UPS should capture and display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass / Total Running time, etc. i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load / UPS Fault /Battery charging and discharging, overload, battery voltage and battery capacity. j) Audible Alarms: Mains Failure, Battery Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short circuit, Over Temperature. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. 8.1 20KVA (Each Power module shall be < 10 KVA) 2.00 Each 341772.00 683544.00 9 Supplying and fixing of following rating four pole 415V, MCB TPN, C Curve in the existing MCB DB complete with connections, testing and commissioning etc. as required. 9.1 63Amp 6.00 Each 2318.00 13908.00 10 Supplying and drawing of UTP 4 pair CAT 6A LAN Cable in the existing surface/ recessed Steel/ PVC conduit/DLP as required. 3300.00 Metre. 77.00 254100.00 11 Supply Installation Testing & Commissioning of Cat6A UTP Patch cord 1 mtr (For rack and User side) etc as required. 150.00 Each 358.00 53700.00 12 Supply Installation Testing & Commissioning of 24 Port Patch Panel Cat6A Unloaded in 1U form factor, with universal A/B labelling and 110 connector terminations on rear of panel allowing for quick and easy installation of 22 to 24 AWG cable, etc. as required. 5.00 Each 5541.00 27705.00 13 SITC of single UTP CAT6A I/O of specified make including mounting inside single and MS back box of 02Module assembly (if required), RJ 45 Connector as per requirement, inclusive of termination of UTP CAT6A cable at each IO at workstation area/device/ user side/patch panel side etc. as required. 14 Supply and fixing of 105*50 mm DLP PVC trucking system including all accessories like Flexible cover, cover joints, body joints, angles and end caps etc. as required. 100.00 Metre. 1324.00 132400.00 15 Supply, laying, testing and commissioning of fibre optic cable of given capacitates to be laid in prelaid conduits/PVC/DLP etc. as required. 15.1 4 core, single mode, optical cable 200.00 Metre. 43.00 8600.00 16 Splicing/termination of fibre optic cable cores using fusion splicing with pre-terminated pigtails, dressing and proper fixing in splice trays. 25.00 Each 641.00 16025.00 17 Supplying and fixing TPN sheet steel enclosure on surface/ recess (but without MCB/MCCB) complete with connections etc. as required. 4.00 Each 726.00 2904.00 18 Supply and installation of ABC (DCP) Type fire extinguisher 06KG, MAP-90%, portable type, average range of throw 05 meter, avg discharge time 24 sec. weight (full) is approx. 8.9kg, operating temp range - 30 C to +60 C with nozzle and Hose as per latest IS standard etc. as required. 4.00 Each 6831.00 27324.00 19 Supply and installation of CO2 type 4.5KG fire extinguisher, portable type, average range of throw 02 meter, avg discharge time 11 sec, weight (full) is approx. 18kg, operating temp range -30 C to +60 C with nozzle and Hose as per latest IS standard etc. as required.

Key Value

Document Fees
INR 500 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail