Tender For Repair And Renovation Of 12 Nos Type Iii Qtrs At Arc Sarsawa; 1 Demolition of brick/stone masonry built in cement/lime mortar of any mix including all quoins pillar ashlars masonryand removal complete all as specified& directed. 2 Material and labour for brick work with sub class B, burnt clay bricks of old size, designation 100, straight or curved on plan exceeding 6 mtr mean radius, built in cement mortar 1:6 complete all as specified & directed. 3 Material and labour for brick work with sub class B, burnt clay bricks of old size, designation 100 straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and directed. 4 Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed. 5 Material and labour for rendering 10mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified. 6 Material and labour for rendering 15mm thick in two layer in CM 1:4 with water proof compound on stone wall surfaces or other than fair faces of brick work & surfaces finished even and smooth without using extra cementcomplete all as specified.Note : Water proofing compound shall be measured and paid for seperately. 7 Material and labour for rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified. 8 Material and labour for preparation of new plastered surfaces of walls apply two or more coat Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specificationincluding priming coat a primer applied @ 0.90 litre/ 10 sqmon the surface complete incuding necessary scaffolding all as specified and directed at any height . Note : Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.Make -Asian Paints Royal(10 years product warranty) orNerolac(10 years product warranty)/Berger(10 years product warranty) at any height incuding necessary scaffolding. 9 Material and labour for preparation of complete removal of existing surfaces of walls apply two or more coat Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specificationat any height incuding necessary scaffolding. Note : Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.Make -Asian Paints Royal(10 years product warranty) orNerolac(10 years product warranty)/Berger(10 years product warranty) at any height incuding necessary scaffolding. 10 Material and labour for preparation of new plastered surfaces of Ceiling apply twocoat Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specificationincluding priming coat a primer applied @ 0.90 litre/ 10 sqmon the surface complete all as specified and directed at any height incuding necessary scaffolding. Note : Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.Make -Asian Paints Royal(10 years product warranty) orNerolac(10 years product warranty)/Berger(10 years product warranty) at any height incuding necessary scaffolding. 11 Material & Labour for preparation of new plaster surfaces applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed at any height incuding necessary scaffolding over new/complete removal surfaces.Note :- (i) Primer and emulsion application to be carried out through air less spray machine (Only mechanical application allowed except in paint application on bands/chajja/building edges/borders/projections where contrasting color as specified and directed is to be applied). (ii) Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper masking to be carried out before primer and paintapplication).Make - Nerolac Excel Top guard (10 years product warranty)/ Asian Paints Ultima Protek (10 years product warranty)/ Berger weather coat long life 10 (10 years product warranty) at any height incuding necessary scaffolding. 12 Material and labour for preparation of Old plastered/complete removal of existing surfaces of Ceilingapply distempering two or more coat with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specification using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper including priming coat of exterior primer applied @ 0.90 litre/ 10 sqmshould be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed at any height incuding necessary scaffolding. Note : Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.Make -Asian Paints Royal(10 years product warranty) orNerolac(10 years product warranty)/ Asian Paints Royal(10 years product warranty)/ Berger(10 years product warranty) at any height incuding necessary scaffolding. 13 Material and labour for exterior or interior waterproof/weather proof cement based1 mm thick putty @ 1 Kg(undiluted) per sq mtr. onnew plastered/old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps:-Step 1) Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute.Step 2) Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI. 14 Taking down shutter of any description exceeding 1 Sqm and not exceeding 2 Sqm each complete all as specified and as directed. 15 Taking down chowkhat or frame (without taking off shutter from the frame)not exceeding 1.5 Square Metre each , removing from the site including cutting holes required fortaking out existing hold fast etc. complete all as specified and as directed. 16 Taking down chowkhat or frame (without taking off shutter from the frame) exceeding 1.5 Square Metre and not exceeding 04 Square Metre each , removing from the site including cutting holes required fortaking out existing hold fast etc. complete all as specified and as directed. 17 Material and labour for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam sheet instead ofWood grain printed PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing. 18 Supply and fixinging Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded prelam PVC `C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of prelam both side PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, stile & rails feathered at edges, suppling & fixing in the frame at site as per specification & drawing. 19 Supply and fixinging 35 mm thick IInd class hard woodGlazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); supplied and fitted to chowkats complete all as specified and directed.Note : Door shutter width not exc 0.85mwith single shutter each door but door shutter width exc 0.85m two panel shutter each doorwithout any extra cost. 20 Material and labour for Flush shutters 32 mm thick, solid core construction, with block board core and ply wood face panels, commercial type on both sides complete all as specified and as directed by the Engineer-in-Charge. 21 Material and labour for for preparing of newuntreated wooden surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint (of approved shade) over a coat of pink primer complete all as specified. 22 Material and labour rolled mild steel framed work as in chowkats of door or gates of angle or other section with gusset plates, rails braces etc. complete. drilled for fixing for steel sheeting or other covering doors, etc to be prepared for hanging or sliding with and including either hooks and hinges and hanging ,door fitting (exclusive of steel sheeting or other covering, running rails and guides) also fastening and fixingconforming to Fe-410(Gde E-250) quality A complete all as specified and as directed by the Engineer-in-Charge. 23 Material and labour for rolled mild steel work as in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 complete all as specified & directed. 24 Supply and fixinging for 18/19mm thick High Density High Moisture Resistant board (HDHMR) Prelaminated both sides as in Controllers Desk ,palmed boxes,showcase,shutters of Cup Boards etc including 6mm designing teak wood beading on edges complete all as specified and as directed by Engr-in-Charge. 25 Supply and fixinging 75mm extruded brass handles, fabricated type polished complete all as specified & directed by Engr-in-Charge. 26 S & F Width of flaps (when open) 30mm Continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified & directed by Engr-in-Charge. 27 Supply and fixinging FAST DM01SS Stainless Steel Furniture Door Catcher Magnet Size No. 2 for for Wadrobe, Cupboard and Almirah Door. (SS MAT)with Mounting Screw complete all as specified 28 Material and labour for forclamps , hold fasts; wall ties, plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts plate washers and similar small articles conforming to Fe-290 Gde-E-165 ® as directed by Engr-in-Charge. 29 S & F IInd class hard wood plain solid straight chowkat and frame wrought framed rebatted on the solid rounded or chamfered put together with glue pinned at joint complete all as specified. 30 Supply and fixinging stainless steelhinges 100mm long medium weightto pressed steel/angle iron frames by welding/screws all as specified. 31 Supply and fixinging aluminium anodised barrel tower bolt 150mm size extruded section, ISI marked & fixed 32 Supply and fixinging aluminium anodised barrel tower bolt 200mm size extruded section, ISI marked & fixed 33 Supply and fixinging extruded aluminium alloy handles 150mm size fabricated type anodised. ISI marked. 34 Supply and fixinging 300mm Aluminium alloy, anodised, sliding door bolt with hasp ,staple (bolt type) and fixingclips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified. 35 Supply and fixinging anodized aluminium frame with power coating (minimumthickness 50 micron) and other sections for doors, windows, ventilators, partitions,with one or more rebates including joining cleat for fixing etc. complete all as specified & as directed. 36 Supply and fixinging anodized aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m,with power coating (minimumthickness 50 micron)including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos), suitable handle (1 No.) complete all as specified & as directed. 37 Supply only 5mm thick Sheet glass, ordinary quality, in squares n exc 0.5 sq. m each paneall as specified and directed by Engr-in-Charge 38 Supply only 5mm thick Froasted glass in squares n exc 0.5 sq. m each pane all as specified and directed by Engr-in-Charge 39 Supply only5mm thickTinted Coloured glass fixed to metal frame complete all as specified and directed. 40 Supply and fixinging Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples & scrwed complete all as specified and directed 41 Supply and fixinginganodized aluminium grill with power coating (minimumthickness 50 micron) of approved pattern and fixed to the existing window/ventilatorframe with CP brass/stainless steel scrwed @ 200mm center to center, including cutting the grill to proper opening sizefor fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete as per requirement & directed by Engr-in-Charge. 42 Supply and fixinging in repair DOOR SEAL BOTTOM, DOOR AIR GAP RUBBER SHIELD (Best Quality) Anti Rust , Brown/white/balck colour, Black Rubber Complete all as specified Make : Sealplus or Equivalent 43 Taking down cement plaster or other existing treatment from sunken floors, cleaning the surface with wire brushes, brooms etc and finally washing down the area to be treated. Material and labour for for treating the sunken floors and adjoining vertical surfaces as under: (a) Plastering 15 mm in CM 1:3 mixed with liquid type water proofing compound to sunken floors and adjoining vertical surfaces. Surface shall be cured & allowed to dry.(b) Applying Ist layer of cement slurry by brush@ 0.488 Kg per Sqm mixed with acrylic based polymer modified cementeous compound of Adhesive@ 0.253 Kg per Sqm complete as per manufacture instructions.(c) Applying 2nd layer of cement slurry by brush@ 0.488 Kg per Sqm mixed with acrylic based polymer modified cementeous compound of Adhesive @ 0.253 Kd per Sqm complete as per manufacture instructions. (c) Testing the sunken floor for water tightness by ponding water for 72 Hours. (d) Fixing of 32mm dia GI pipe medium grade spout projecting 43 cm beyond wall, one number in each sunken portion. complete all as specified and directed . 44 Supply and fixinging 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including removing the old pipes and making good the disturbed surface as per existing complete all as specified & directed. 45 Supply and fixinging 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches/under floor including removing the old pipes and making good the disturbed surface as per existing complete all as specified & directed. 46 Supply and fixinging in repair80 mm bore PVC (SWR) single junction (single T ) equal or unequalprovided with access door complete all as specified. 47 Supply and fixinging in repair 80mm bore PVC (SWR) bends any radius complete all as specified. 48 Supply and fixingingPVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls/spout pipes including removing the old pipes and making good the disturbed surface as per existing complete all as specified & directed. 49 Supply and fixinging PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints laid in trenches/under floor including removing the old pipes and making good the disturbed surface as per existing complete all as specified & directed. 50 Supply and fixinging in repair 110 mm bore PVC (SWR) bends any radius complete all as specified. 51 Supply and fixinging in repair 110 mm bore PVC (SWR) vent cowl complete all as specified. 52 Supply and fixinging in repair 110 mm bore PVC (SWR) single junction (single T ) equal or unequalprovided with access door complete all as specified. 53 Supply and fixinging in repairs CI spun pipe 75 mm bore fixed to walls or laid in floors complete including jointing all as specified. 54 Supply and fixinging in repairs CI spun pipe 100 mm bore fixed to walls or laid in floors complete including jointing all as specified. 55 Supply and fixinging in repairs CI junction for 100mm bore CI pipe including jointingcomplete all as specified and directed . 56 Supply and fixinging in repairs CI junction for 75mm bore CI pipe including jointing complete all as specified and directed . 57 Supply and fixinging CI bend for 100mm pipe including jointing complete all as specified. 58 Supply and fixinging CI bend for 75mm pipe including jointing complete all as specified. 59 Taking up or down 15mm steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed . 60 Taking up or down 20mm steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed . 61 Supply and fixinging galvanised iron tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge. 62 Supply and fixinging galvanised iron tubing 20mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge. 63 Supply and fixinging as in repairvitreous china wash down water closet pan (Padestal pattern), white (ISI marked), including connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonoage pipe etc & with plastic WC seat cover (white) closed pattern with flat bottom and cover and suitable mild steel chromium plated or aluminised hinging device complete all as specified. 64 Supply and fixinging as in repair vitreous china squatting pan of orrisa pattern long pan size 580mm white (ISI marked) with P or S trap, front or back inlet and foot rest any pattern, including connection to flushing pipe anti-syphonage pipe etc, including setting of pan & trap in lean PCC 1:5:10 complete and making good to distrubed floor with PCC or cement mortar 1:3 to match with sorroundings all as directed. 65 Supply and fixinging in repairs vitreous china wash basin white, flat back, size 550x400mm including pillar tap brass CP 15mm bore with long screwed shanks and fly nuts waste coupling brass CP 32mm bore, flange end bedded in red lead cement and other end fixed and PVC connection 450mm long 15mm bore with 2 Nos nuts and washes CI brackets complete all as specified and directed. 66 Supply and fixinging in repairs Jet spray chromium plated brass for EWC with & including PVC connection 600 mm long suitable for 15 mm bore GI pipe with PTMT nut & nipple complete all as specified and directed. 67 Supply and fixinging in repairs PVC connection of 15mm bore with2 Nos. PTMT nuts, 60m long fixed with one end to pillar tap & the other end to stop cock or iron pipe all as directed by Engineer-in-charge. 68 Supply and fixinging in repair towel rails of 20mm dia tubular brass chromium plated 60cm long D type fixed to all as directed by Engr-in-charge. 69 Supply and fixinging in repairs MS grating CP 100mm dia, with hole/without for waste pipe of approved make including fixing with CM to floor/nahani traps etc complete all as directed. 70 Supply and fixinging in repairs brass chromium plated shower rose 125mmx125mm size with swivel joint type including fixing to steel pipe of 15mm bore or union complete all as specified. 71 Supply and fixinging in repairs looking mirror 600x450mm bevelled edge 5.5mm thick selected quality glass, mounted on 6mm thick commercial ply, aluminium frame around and fixed to wooden plug with CP brass screws and cup washeres and as directed. 72 Supply and fixinging in repair15 mm fancy type, chromium plated, bib tap cast copper alloy with crutch or butter fly handle screwed down, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge. 73 Supply and fixinging in repair 15 mm fancy type angle valves, chromium plated alloy screwed down high presure, screwed both ends for iron pipe or for unions of 15 mm dia long sunk concealed type complete all as specified & directed by Engr-in-Charge. 74 Supply and fixinging in repair15 mm Angle Stop valves, cast copper alloy chromium plated screwed down, high pressure, with crutch or butter fly handle screwed both ends for iron pipe or for unionssuitable for 15 mm bore tubes, complete all as specified. 75 Supply and fixinging in repair 20mm bore Stop valves, cast copper alloy screwed down high presure, screwed both ends for iron pipe or for unions fixedcomplete all as specified. 76 Supply and fixingingin repair chromium plated Brasshealth faucet for EWC with including PVC Connection 1m long suitable for 15mm borewith all connected fittings complete all as specified. 77 Supply and fixinging32/40mm dia PVC flexible waste pipe 80cm long withsocket for union, for WHB/urinal/sink complete all as specified. 78 Supply and fixinging in repairs ofsize 600mm x 100mm with SS railing glassshelf rectangular typecomplete all as specified & as directed. 79 Supply and fixinging in repairs of 300 mm dia with SS railing glass corner shelf complete all as specified & as directed. 80 Supply and fixinging in repair 15 mm2-in-1 CP bib cock complete all as specified and directed by Engr-in-Charge. 81 Supply and fixinging in repair 15 mm 2 wayCP angle cock completeall as specified and directed by Engr-in-Charge. 82 Supply and fixinging in repair Brass CP Soap Dispenser with Glass Bottle complete all as specified. 83 Dismantling water tanks of capacity exc 250ltr but not exc 500ltr and removing from site complete all as specified & directed by Engr-in-Charge. 84 Supply and fixinging 500 Litre capacity Rotational moulded polyethylene water storage tanks Triple layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc.complete as specified. 85 Supply and fixinging ball valves brass high pressure with polythelene float and fly net complete, screwed , iron pipes 15 mm diacomplete all as specified & directed by Engr-in-Charge 86 Supply and fixinging Mirror Cabinet PVC frame of size 400x500mm fixed to wall with rawl plug & stainless steel suitable size scrweds complete all as specified and directed. 87 Dismentling floor , hearth or wall tiling incl cement mortar bedding (but ot backing) , removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. 88 Material and labour for 25 thick cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as inlevelling coarse for tiles complete all as specified and directed. 89 Material and labour for 100 mm thick PCC 1:4:8 type D -2 using 40 mm graded stone aggregate as in sub basecomplete all as specified& directed by Engr-in-Charge. 90 Material and labour for for double charged vitrified ceramic tiles 8mm to 9mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10 mm thick screed bed in cement & sand mortar 1:6 complete all as specified and directed. 91 Material and labour coloured non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed. 92 Material and labour for for double charge vitrified ceramic tiles8 to 9mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile not exceeding 0.36 sqm, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick screed bed in cement & sand mortar 1:4 complete all as specified and as directed. 93 Material and labour for Glazed ceramic coloured tiles in vertical surface450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles and over 10 mm thick rendring in cm 1:4 complete all as specified& directed by Engr-in-Charge. 94 Material and labour for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing completeincl 15mm thick screed bed in CM 1:4 complete all as specified and directed. 95 Material and labour for machine cut kota stone slab flooring 20mm - 25mm thick (size not less than 550mm x 550mm) as in flooring, set and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to achieve mirror finish laid over & including screed bed / bedding layer of 15mm thick in cement mortar 1:4, complete all as specified & directed 96 Material and labour for machine cut kota stone slab 20mm - 25mm thick (size compatible to floor) as in vertical surfaces (skirting, dado, riser, steps), set and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to achieve mirror finish laid over & including rendering plaster or backing coat of 15mm thick cement mortar 1:4, complete all as specified & directed. 97 Demolition of cement concrete (un-renforced) in ground floor and paving. exc. 15 cm thickness(below or above ground level.) & removal of rubbish material complete all as directed by Engineer-in-charge and all as specified. 98 Supply and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified & directed. 99 Material and labour for 75 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as inplinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. 100 Demolition Mud in roofs, any thicknes, including plastering , existing tretement and cleaning (whether full thickness removed or only or part there of)etcin all respect and preparing it for further treatment and taking out and disposal of debris & rubbish to a distance exc 1 Km but not exc 1.5 Km complete all as specified & directed by Engr-in-Charge. 101 Material and labour for screed laid 10mm thick in CM 1:4with water proofing compound over green concrete surface(WPC will be measured and paid seperately) surface finished even and smooth (without using extra lime or cement) complete all as specified& directed by Engr-in-Charge. 102 Supply only integral liquid water proofing compound (ISI marked). 103 Material and labour for Atactic Polypropylene (APP) polymeric water proofing treatement to roof, at any height, using membrane minimum 3 mm thick and weighting not less than 3.0 kg per sqm, black finish reinforced with non-woven polyster matt (Weight not less than 150 gram per Sqm), with properties of high penetration and centre core consisting of 90 micron, high molecular high density polyethylene (HMHDPE) film consisting of five layers with thermo fusible finish laid by force application after applying compatible bitumen primer at the rate of 0.40 litre per Sqm, torching over laps with a propane orbutane gas torch with a over lap of 100 mm at the side on transverse direction and 150 mm at the ends on longitudinal direction and sealing including a tack coat of hot blown bitumen 85/25 @ 1.2 Kg per Sqm below APP including applying one coat of heat repellant bitumen aluminum paint @ 0.10 litre per sqm on top of the treated surface of roof complete all as specified & directed .Notes: (i) The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators duly approved by GE in writing.(ii) Contractor shall submit Security deposit as a guarantee against Water proofing treatment as specified. 104 Material and labour for providing cement concrete intype B0 1:2:4 (using 12.5 mm graded crushed stone aggregate) as in roof padding,laid to(consolidated thickness 65mm or less) as leveling course, laid and compacted inmin slope 1:30 over roof complete all as specified& directed by Engr-in-Charge. 105 DismantlingPlain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings. 106 Material and labour for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified & directed. 107 Material and labour for for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engr-in-Charge. 108 Material and labour for for Cutting openings, through brick walls for door, window and other openings or enlarging existing openings.converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and directed by Engr-in-Charge. 109 Supply and fixinging in repairs brass chromiumfor 2 in 1 wall mixer & screwed down for iron pipe of 15mm bore all as specified and as directed. 110 Demolition and breaking up drain pipes 150 mm dia (salt glazed ware AC or reinforcement concrete set in cement mortar. 111 Material and labour for 150 mm Salt glazed stonware pipelaid and jointed complete with collars complete all as specified and directed by Engr-in-Charge. 112 Material and labour for 150 mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed by Engr-in-Charge. 113 Material and labour for for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate for 150 mm dia bore drain pipe for bed concrete including packing under and hunching against the sides of pipe after they are laid and tested complete all as specified and directed by Engr-in-Charge. 114 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/ loose soil complete all as specified and directed by Engr-in-Charge. 115 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and exc 1.5 m but not exc 3.00 m in depth and getting out soft/ loose soil complete all as specified and directed by Engr-in-Charge. 116 Material and labour for cement conc. 1:4:8 type D2 (40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified. 117 Returning, filling in, including spreading, levlling ,watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge. 118 Removing surplus excavated material to a distance exc 250m but n.exc 500m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge. 119 Material and labour for for 150mm dia Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed by Engr-in-Charge. 120 Demolition ofreinforced cement concrete as in cover/slab of drain/culvert/septic tank/soakage wellall a specified & directed by Engineer-in-Charge. 121 Material and labour for for precast RCC 1:2:4type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including placing in position and set in CM (1:6) complete all as specified & as directed.Note :- Reinforcement shall be measured and paid for separately. 122 Material and labour for Mild steelTMT bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to TMT bar complete all as specified and directed by Engr-in-Charge. 123 Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators,socket outlet but excludingtube light fittings, calling bell etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etccomplete all as specified and as directed by the Engineer-in-Charge. 124 Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 25 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfacesand incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally including provision of new covered plate over sunken box for housing themodular switches , modular socket outlets,modularfan regulators etc. and making smooth the disturbed surfaces as per existingfor one light/fan/exhaust fan point controlledby one way switch,complete all as specified and as directedby Engineer-in-Charge. Note :-a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid forseparately . 125 Description same all as per item No. 124here-in-abovebut for One 3 pin, 5 Amps, socket outlet controlled by one switch on independent board,complete all as specified and as directedby Engineer-in-Charge. 126 Description same allas per item No.124 here-in-abovebut for One 3 pin 5 Amps socket outlet controlled by one switch on same board,complete all as specified and as directedby Engineer-in-Charge. 127 Description same allas per item No.124 here-in-abovebut for bell/buzzer point,controlled by one bell switch complete all as specified and as directedby Engineer-in-Charge. 128 Description same allas per item No.124 here-in-abovebut for two way point,controlled by two way switch complete all as specified and as directedby Engineer-in-Charge. 129 Description same all as per srl item No 124 here-in-before but for one socket outlet 15 Amp with 2.5 sqmm PVC insulated, unsheathedcable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.5 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copperwire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge. 130 Supply and fixingmodular socket outlet2/3 pin, 6 Amp, one way, two module, 230 voltscomplete all as specified and as directedby Engineer-in-Charge. 131 Supply and fixingmodular socket outlet2/3 pin, 16 Amp, one way, two module, 230 voltscomplete all as specified and as directedby Engineer-in-Charge. 132 Supply and fixing modular switch 1 module, single pole, one way 6 Amps flush type, 230 voltscomplete all as specified and as directedby Engineer-in-Charge. 133 Supply and fixing modular switch 1 module, single pole, one way 16 Amps flush type, 230 voltscomplete all as specified and as directedby Engineer-in-Charge. 134 Supply and fixingmodular bell push 6 Amp, one way, one module, 230 voltscomplete all as specified and as directed by the Engineer-in-Charge. 135 Supply and fixingmodular switch 1 module, single pole, two way 6 Amps flush type, 230 voltscomplete all as specified and as directedby Engineer-in-Charge. 136 Supply and fixingcalling bell ding dong 230 voltcomplete all as specified and as directed by the Engr-in-charge. 137 Supply and fixinglamp holder, PVC/polycarbonate type, with back plate for angular batten fittings complete all as specified and as directed by the Engineer-in-Charge. 138 Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminalcomplete all as specified and as directedby Engineer-in-Charge. 139 Supply & layingsub main wiring with two run of 4 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 4 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI markedmulti stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall and surface on ceiling in PVC conduit medium gradeISI marked of adequate size for housing the wirescomplete including taking down old sub main wiring all as specified. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.(ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length. 140 Supply & layingsub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI markedmulti stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall and surface on ceiling in PVC conduit medium gradeISI marked of adequate size for housing the wirescomplete including taking down old sub main wiring all as specified. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.(ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length. 141 Supply and fixing sheet metal MCB DBs 12 way with 200 Amps rated bus bar single pole and neutralIP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surface after removing old Unserviceable MCB DB complete all as specified and as directed by the Engineer-in-Charge. 142 Supply and fix sheet metal enclosureVertical triple pole & neutral (VTPN) with TPN MCCB 100 Amp for 415 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and includinglugs/thimbles duly crimped for connection, necessary PCC work and making smooth the disturbedcomplete all as specified and as directed by the Engineer-in-Charge. 143 Supply and fixing MCB single pole, 240 volt, 6 to 32 amps, 10 KA C curvecomplete all as specified and as directedby Engineer-in-Charge. 144 Supply and fixing MCB SPN, 240 volt, 6 to 40 amps, 12 KA C curvecomplete all as specified and as directedby Engineer-in-Charge. 145 Supply and fixing electronic Fan step regulator modular 110 watt, 1 module, 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and as directed by the Engineer-in-Charge. 146 Supply and fixing modular blanking plate, 1 module complete all as specified and as directed by the Engineer-in-Charge. 147 Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised iron wireearth lead of 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron, earth wire protected by GI pipe 15mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c with one handle for liftingmade out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion . 148 Supply and fixingearth continuity conductor nor main earthing lead of 4.00 mm galvanised iron wire, burried in ground or fixed on wall in and including 15 mm bore GI pipe medium grade fro protection of earth wire complete all as specified and as directed by the Engineer-in-Charge. 149 Supply and fixingLED surface mounted bulk head luminaries 1x8-10 W with min 800 lumen, industrial model, IP 65, Aluminum housing, surge protection including driver & LED lampetc complete with all accessories connecting with three core copper conductor flexible cablefrom ceiling rose to connector of the lightas in repair complete all as specified and as directed by the Engineer-in-Charge. 150 Supply and fixing indoor decorative LED tube light fitting Batten type 1x18/20 Wwith opal diffuser, high efficient aluminium housing body in CRCA body suitable for LED tube, high efficient, AC 220-240 volts, 50 Hz and including 1x18/20 W LED tube rod luminaries (Warm/Cool as per site requirement) environment friendly, high efficient, T8 with aluminium extrusion heat sinkconnecting with copper conductor flexible cablefrom ceiling rose to connector of the lightcomplete all as specified and as directed by the Engineer-in-Charge. 151 Supply and fixing LED batten fitting 10-12 watt, 2 feet, 6500Kaluminium housing and integrated electronic driver including tube rod cool/warm typeindustrial model completeconnecting with copper conductor flexible cablefrom ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge. 152 Supply & fixing single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA C curve as in repair complete all as specified and as directed by the Engr-in-charge. 153 S&F designer wall bracket having wooden base of brown colour and V shape designer glass matching with wooden basealongwith9 watt LED bulb with B-22 base as in repair complete all as specified and as directed by the Engineer-in-Charge. 154 Supply and fixingPVC, round shape junction box cover of suitable sizecomplete all as specified and as directed by the Engineer-in-Charge. 155 Taking down old UNSV DBs including old MCB/MCCBs of any size from any locationcomplete all as specified and as directed by the Engineer-in-Charge. 156 Supply and fixing plastic body ventilation fan 250 mm sweep, 1250 RPM, 50HZ,240 volts complete with cooper wound motor including all fixing accessories and including making the electrical connection by using three core wire with colour code complete all as specified and as directedby Engineer-in-Charge. 157 Shifting of existing electric energy meter with box to other location as directed complete all as specified and as directedby Engineer-in-Charge. 158 Supply and fixing Energy meter box, flame retardant, polycarbonate body including all fixing arrangenment like DIN rails, mounting plate, connection boxes, fastning screw protection plate etc. suitable to accomodate single phase energy meter with locking arrangementcomplete all as specified and directed. 159 Supply and fixing 09 watt LED bulb with B22 base cap, 1200 lumens, colour rating index 80, colour, temp F 6500K, startup time less that 2 second, in built surge 3.0 kv, voltage range 140V to 270V, lamp life 15000 hours complete all as specified and as directed. 160 Supply and fixing as in replacement, enviorment freindly,indoor decorative LED polycarbonate body, tube light fitting Batten type, 5/6 Wwith opal diffuser, operating voltage range 14 V to 270 V, driver effciency 88%, lumen effceincy = 100 Im/watt, THD≤80, colour temperature 6500 K, inbuilt surge protection = 2.5 KV, isolation = 3.75 and with zero merucry content including all accessariesall as specified and directed as directed by the Engineer-in-Charge. 161 Supply and fix exhaust fan 300 mm sweep, anti corrsive metal body, sturdy metal bird guard copper wounded, double ball bearing, five star rating,1320 RPM,50HZ, 240 volts complete with dynamically balanced blade for vibration free rotation, split pin, clamp and fixing at site on and includingMS fabricated base frame using flexible wire after making hole in wall as required at site andmaking goodthe disturbed surfaces and including making the electrical connection by using three core wire with colour code complete all as specified and as directedby Engineer-in-Charge. 162 Supply & fixing electric water heater(Geyser), storage type, steel body with copper inner tank, heating element of 2KW, storage capacity 25 litre, electrically operated, BEE 5 Star rated with all accessories such as safety valve, thermostate, NRV, SS connection pipe, temperature control knob etc. including fixing lugs, bolts etc and installation on location by drilling holes and plug to fastners by bolts and rawl plug, including making connection with3 core flexible copper wire of size 2.5 Sqmm from geyserto metal plug & socket complete all as specified & directed. 163 Supply and fixing ceiling fan 1200 mm sweep, 240 volts complete with blades, down rod, electronic regulator and all accessories, having minimum air delivery 210 CFM, BEE five star rates with brushless direct current motor (BLDC) complete including making the electrical connection by using three core wire with colour code complete all as specified and as directedby Engineer-in-Charge. 164 Taking down Ceiling fan/Exhaust fan/Geyser by disconnecting electric connection, and deposited to MES store yard before execution of work and refixing the same after completion of B/R repair after cleaning all dust etc.complete all as specified and as directed by the Engineer-in-Charge. 165 Taking down LT panel by disconnecting cable and sub main wiring properly complete all as specified and directed.Note : Meter shall be deposited in MES store yard. 166 Supply and fixing as in replacement metel flush box 4 module complete all as specified and directed. 167 Supply and fixing as in replacement metel flush box 6 module complete all as specified and directed. 168 Supply and fixing as in replacement white cover plate with frame suitable for 4 module box complete all as specified and directed. 169 Supply and fixing as in replacement white cover plate with frame suitable for 6 module box complete all as specified and directed. 170 Supply and fixing MCCB, 3 pole, 415 volts, adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed. 171 For Credit Schedule refer tender documents. The amount of credit schedule shall be deducted in total quoted amount of BOQ to arrive contract sum.