Tender For Repair/Maintenance Of Different Type/Capacity Of Centrifugal/ Submersible/Monoblock Pump Sets Including Borewells And Allied Works At Af Stn Naliya, naliya-Gujarat

Tender Notice

51848794
Tender For Repair/Maintenance Of Different Type/Capacity Of Centrifugal/ Submersible/Monoblock Pump Sets Including Borewells And Allied Works At Af Stn Naliya
Tender
Indian
Gujarat
Naliya
07-11-2025

Tender Details

Tender For Repair/Maintenance Of Different Type/Capacity Of Centrifugal/ Submersible/Monoblock Pump Sets Including Borewells And Allied Works At Af Stn Naliya; 1 Material and labour for repair & overhauling of 70/75 HPelectrical induction motor, 3 phase, 415 volts including disconnecting all electrical connections, decoupling from pump, taking down the motor from foundation, cleaning and varnishing the stater & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignmentconnecting all electrical connections, checking the vibrations, RPM, DOR,testing on full load complete all as specified and directed. 2 All as per serial item numer 1.00 here-in-before but of capcity 60HP, 3 Phase 3 All as per serial item numer 1.00 here-in-before but of capcity 15HP-20 HP, 3 Phase 4 Material and labour in repairs for rewinding of 70/75 HP, 3 Phase capacity induction motor by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new copper wire of existing gauge and size / turns, varnishing with class B insulation, balancing of shaft, incl replacement of UNSV connection plate / terminal point as per site requirement, assembling the motor including transportation, testing as per the specified RPM at workshop complete all as specified and as directed. 5 All as per serial item numer 4.00 here-in-before but of capcity 60 HP, 3 Phase 6 All as per serial item numer 4.00 here-in-before but of capcity 15 to 20 HP, 3 Phase 7 Material and labour for repair & overhauling of 70/75 HP, 3 Phase capacity centrifugal pump set of any make, dismantling and taking down pump after disconnecting water supply connections, decoupling from motor removing out impeller, cleaning, descaling , greasing to bearings and replacement of unserviceable parts such as bearings, pump shaft sleeves, coupling pully, pump shaft etc.Assembly in the pump with new packing materials, nuts, bolts & washers , gland bolt & packing,coupling bushes, coupling boltsand coupling with motor checking for vibration & alignment connectingdelivery and suction pipe, testing the pump setscomplete all as specified and directed.Note :- Spare parts shall be measured and paid separately 8 All as per serial item numer 7.00 here-in-before but of capcity 60 HP, 3 Phase 9 All as per serial item numer 7.00 here-in-before but of capcity 15 to 20 HP, 3 Phase 10 Supply and fix in repair following parts for existing centrifugal pump set electric driven 3 phase 415 volt 75/70 HP complete all as specified and directed. 11 Motor bearing. Make : SKF/NBC/TATA/FAG/ UBC. 12 Motor cooling fan 13 Pump motor Pin bush coupling of size RB 198/10 with nut bolts, washer 14 L-225/190 spider. 15 Cover bolts & washers 16 Pump bearing with housing, Oring. Make : SKF/UBC/TATA/FAG/ NBC 17 CI impellaras per existing model complete 18 SS Sleeve (Gland Sleeve) 19 Pump SS shaft with studs and nuts for pump body. 20 Shaft seal of existing size 21 Supply and fix in repair following parts for existing centrifugal pump set electric driven 3 phase 415 volt 60 HP complete all as specified and directed :- 22 Motor bearing. Make : SKF/NBC/TATA/FAG/ UBC. 23 Motor cooling fan 24 Rubber bushes for coupling as per existing model and size 25 Pump motor Pin bush coupling of size RB 198/10 with nut bolts, washer 26 Cover bolts & washers 27 Pump bearing with housing, Oring. Make : SKF/UBC/TATA/FAG/ NBC 28 CI impellaras per existing model complete 29 Gland packing 30 SS Sleeve (Gland Sleeve) 31 SS Pump shaft with studs and nuts for pump body. 32 Shaft seal of existing size 33 Supply and fix in repair following parts for existing centrifugal pump set electric driven 3 phase 415 volt 15 to 20 HP complete all as specified and directed:- 34 Motor bearing. Make : SKF/NBC/TATA/FAG/ UBC. 35 Motor cooling fan 36 Cover bolts & washers 37 CI impellaras per existing model complete 38 SS Pump shaft with studs and nuts for pump body. 39 Shaft seal of existing size 40 Material and labour for repair & overhauling of 2 to 7.5 HP, 3 Phase monoblock pump set, taking out impeller, cleaning, descaling & greasing to bearings incl replacement of unserviceable parts such as bearings, gland flange,etc.Cleaning and varnishing the starter and rotar, winding, heating and drying replacement of burnt terminals of motor assembling in the pump with new packing materials nuts, bolts, washers checking alignmentconnecting all electrical/water connections,checking the vibrations & alignment, RPM,DOR,testing the pump sets of on full load, complete all as specified and directed.Note:-(i) Cost of smallU/S parts such as new packing materials, nuts, bolts & washers, gland bolt & packing, coupling bushes , coupling bolts shall deemed to be inclusive inquoted rate. (ii) Major unserviceable spares as listedbelow shall be measured and paid separately. 41 All as per serial item numer 13.00 here-in-before but of capcity 0.5 to 3 HP, 1 Phase 42 Supply only greasing for bearing of centrifugal Pumps all as specified and as directed. 43 Material and labour in repairs for rewinding of 2 to 7.5 HP , 3 Phase capacity monoblock pump set by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new copper wire of existing gauge and size / turns, varnishing with class B insulation, balancing of shaft, incl replacement of UNSV connection plate / terminal point as per site requirement, assembling the motor including transporation, testing as per the specified RPM at workshop complete all as specified and directed. 44 All as per serial item numer 16.00 here-in-before but of capcity 0.5 to 3 HP, 1 Phase 45 Supply and fix in repair following parts for existing monoblock pump set electric driven 3 phase 415 volt 2 to 7.5 HP complete all as specified and directed. 46 Motor bearing with housing . Make : SKF/NBC/TATA/FAG/ UBC. 47 Motor cooling fan 48 Cover bolts & washers 49 CI impellaras per existing model complete 50 SS Sleeve (Gland Sleeve) 51 SS Pump shaft with studs and nuts for pump body. 52 Shaft seal of existing size 53 Supply and fix in repair following parts for existing monoblock pump set electric driven 1 phase 230 volt 0.5 HP to 3 HP complete all as specified and directed:- 54 Motor bearing with housing . Make : SKF/NBC/TATA/FAG/ UBC. 55 Motor cooling fan 56 Cover bolts & washers 57 CI impellaras per existing model complete 58 SS Sleeve (Gland Sleeve) 59 Pump shaft with studs and nuts for pump body. 60 Shaft seal/water seal of existing size 61 Capacitor of capacity 40 to 100 MFD 62 Capacitor of capacity 120 to 250 MFD 63 Material and labour for lifting of submersible pump set of 30HP to 40 HP capacity for repair and overhauling, carefully from bore well alongwith existing submersible cable, MS/GI/HDPE Column pipe of 80mm to 140mm dia, flanged type, 3 meters each length (depth of submersible pump is from 80 to 120 m) and shifting of column pipe, pumpset and disconnecting of submersible cable aside for reuse and lowering into bore well after carying out necessary repair work including jointing of submersible cable with water proof jointing kit, testing, binding of submersible cable with column pipe by using aluminium wire, jointing of nylon rope et complete and testing complete all as specified and as directed.Note :- (i) The quoted rate deemed to be included the cost of replacement of rubber gaskets, nuts, bolts, washers aluminium wire etc.(ii) Any damage to pump set column pipe submersible cable etc while lifting and lowering of pump set shall be repaired / replaced by contractor on his own cost and GEs decision shall be final and binding in this regard. 64 All as per serial item numer 20.00 here-in-before but of capacity 7.5 HP to 15 HP, 3 Phase 65 Material and labour for complete opening of submersible bore well pump motor set of 30 HP to 40 HP capacity for repair / replacement of unserviceable worn out bearing / worn out unserviceable shaft / burned out copper winding as per existing gauge, No of turns, varnishing with specified RPM / worn out strainer / bush / sleeve / thrust pad / thrust bearing / thrust bearing lock nut etc, including re-assembling and testing as per specified RPM at workshop etc complete all as specified and as directed.Note :- (i) The quoted shall be inclusive of transportation of pump set from pump house site to workshop and back to pump house site after necessary repairs.(ii) The quoted shall be inclusive of balancing of shaft through lathe work incl welding wk if any required as per site requirement, balancing of starter, repairing starter stamping, water cap, SS nut, bolts, washers etc complete.(iii) The quoted shall be inclusive of shaft rubber seal etc complete(iv) Winding shall be measured and paid separately.(v) Spares replaced shall be measured and paid separetely under relevant item. 66 All as per serial item numer 22.00 here-in-before but of capcity 7.5 to 15 HP, 3 Phase 67 Material and labour for rewinding the submersible motor of30HP to 40 HP capacity by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new PVC insulated copper wire of existing gauge and size / turns, balancing of shaft, testing as per the specified RPM at workshop complete all as specified and as directed. 68 All as per serial item numer 24.00 here-in-before but of capcity 7.5 to 15 HP, 3 Phase 69 Supply and fix in repair following parts for existing submersible pump set electric driven 3 phase 415 volt 30 to 40 HP complete all as specified and directed:- 70 Thrust bearing incl bush 71 Revolving Disc 72 SS Connection piece 73 CI upper housing 74 CI Lower housing 75 CI Motor Base 76 Thrust plate 77 CI Suction chamber 78 CI stage bowl 79 GM bush for pump 80 SS Impeller 81 CI DOL Piece 82 Bearing housing 83 Sand guard/cover 84 Pump shaft sleeve of SS 85 PVC Neck Ring of existing model 86 T Bolts of existing size and model 87 Pump shaft lathe work including turning, straightening etc complete 88 Supply and fix in repair following parts for existing submersible pump set electric driven 3 phase 415 volt, 7.5 HP to 15 HP complete all as specified and directed :- 89 Thrust bearing incl bush 90 Revolving Disc 91 SS Connection piece 92 CI upper housing 93 CI Lower housing 94 CI Motor Base 95 Thrust plate 96 CI Suction chamber 97 CI stage bowl 98 GM bush 99 GM Impeller 100 CI DOL Piece 101 Bearing housing 102 Sand guard/cover 103 Pump shaft sleeve of SS 104 PVC Neck Ring of existing model 105 T Bolts of existing size and model 106 Material and labour for Lifting of submersible pump set of 40HP to 50 HP capacity, 3 Phase carefully from open well/UG Sump/SWT alongwith existing submersible cable, MS/GI/HDPE Column pipe of any dia and shifting of column pipe, pumpset and disconnecting of submersible cable aside for reuse and lowering into well/sump/SWT after carying out necessary repair work including jointing of submersible cable with water proof jointing kit, testing, binding of submersible cable with column pipe by using aluminium wire complete and testing complete all as specified anddirected.Note :- (i) The quoted rate deemed to be included the cost of replacement of rubber gaskets, nuts, bolts, washers aluminium wire etc.(ii) Any damage to pump set pipe submersible cable etc while taking out and lowering of pump set will be repaired/replaced by contractor on his own cost and GEs decision shall be final and binding in this regard. 107 All as per serial item number 28.00 here-in-before but of capcity 20 to 30 HP, 3 Phase 108 All as per serial item number 28.00 here-in-before but of capcity 10 to 15 HP, 3 Phase 109 All as per serial item number 28.00 here-in-before but of capcity 3 to 7.5 HP, 3 Phase 110 All as per serial item number 28.00 here-in-before but of capcity 0.5 to 2 HP, 1 Phase 111 Material and labour for complete opening of horizontal submersible motor 40 HP to 50 HP for repair /replacement of unserviceable worn out bearing/worn out unserviceable shaft/burned out copper winding /worn out strainer/bush/sleeve/thrust pad/thrust bearing/thrust bearing lock nut etc including transportation complete all as specified and directed.Note :- (i) The quoted shall be inclusive of transportation of pump set from pump house site to workshop and back to pump house site after necessary repairs.(ii) The quoted shall be inclusive of balancing of shaft through lathe work incl welding wk if any required as per requirement, replacement of pump seal, replacement of wornout nut, bolts, washers etc complete.(iii) Winding shall be measured and paid separately. 112 All as per serial item number 33.00 here-in-before but of capcity 20 to 30 HP, 3 Phase 113 All as per serial item number 33.00 here-in-before but of capcity 10 to 15 HP, 3 Phase 114 All as per serial item number 33.00 here-in-before but of capcity 3 to 7.5 HP, 3 Phase 115 All as per serial item number 33.00 here-in-before but of capcity 0.5 HP to 2 HP, 1 Phase 116 Material and labour for rewinding the submersible motor of40HP to 50 HP capacity by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new PVC insulated copper wire of existing gauge and size / turns, balancing of shaft, testing as per the specified RPM at workshop complete all as specified and directed. 117 All as per serial item number 38.00 here-in-before but of capcity 20 to 30 HP, 3 Phase 118 All as per serial item number 38.00 here-in-before but of capcity 10 to 15 HP, 3 Phase 119 All as per serial item number 38.00 here-in-before but of capcity 3 to 7.5 HP, 3 Phase 120 All as per serial item number 38.00 here-in-before but of capcity 0.5 to 2HP, 1 Phase 121 Supply and fix in repair following parts for existing submersible pump set electric driven 3 phase 415 volt 40 HP to 50 HP complete all as specified and directed :- 122 Pump Thurst bearing Make : SKF/NBC/TATA/FAG/ UBC. 123 Pump bush 124 SS sleeve 125 CI impellaras per existing model 126 Pump shaft 127 Shaft seal of existing size 128 Thrust plate 129 Supply and fix in repair following parts for existing submersible pump set electric driven 3 phase 415 volt 20 HP to 30 HP complete all as specified and directed:- 130 Pump Thrust bearing Make : SKF/NBC/TATA/FAG/ UBC. 131 Pump bush 132 SS sleeve 133 CI impellaras per existing model 134 Pump shaft 135 Shaft seal of existing size 136 Thrust plate 137 Supply and fix in repair following parts for existing submersible pump set electric driven 3 phase 415 volt 10HP to 15 HP complete all as specified and directed :- 138 Pump Thrust bearing Make : SKF/NBC/TATA/FAG/ UBC. 139 Pump bush 140 SS sleeve 141 CI impellaras per existing model 142 Pump shaft 143 Shaft seal of existing size 144 Thrust plate 145 Supply and fix in repair following parts for existing submersible pump set electric driven 3 phase 415 volt 5 HP to 7.5 HP complete all as specified and directed:- 146 Pump bearing Make : SKF/NBC/TATA/FAG/ UBC. 147 Pump bush 148 SS sleeve 149 CI impellaras per existing model 150 Pump shaft 151 Shaft seal of existing size 152 Thrust plate 153 Supply and fix in repair following parts for existing submersible pump set electric driven 1 phase 230 volt 0.5 HP to 2 HP complete all as specified and directed:- 154 Pump bearing Make : SKF/NBC/TATA/FAG/ UBC. 155 Pump bush 156 SS sleeve 157 CI impellaras per existing model 158 Pump shaft 159 Shaft seal of existing size 160 Material and labour for Lifting of non-clog pump set of 10 HP to 15 HP capacity carefully from sewage well alongwith existing submersible cable, MS/GI/HDPE Column pipe of any dia and shifting of column pipe, pumpset and disconnecting of cable aside for reuse and lowering into well after carying out necessary repair work including jointing of submersible cable with water proof jointing kit, testing, binding of submersible cable with column pipe by using aluminium wire complete and testing complete all as specified and as directed.Note :- (i) The quoted rate deemed to be included the cost of replacement of rubber gaskets, nuts, bolts, washers aluminium wire etc.(ii) Any damage to pump set pipe submersible cable etc while taking out and lowering of pump set will be repaired/replaced by contractor on his own cost and GEs decision shall be final and binding in this regard. 161 All as per serial item number 48.00 here-in-before but of capcity 3 to 5 HP 162 Material and labour for complete opening of non-clog pump motor 10 HP to 15 HP for repair /replacement of unserviceable worn out bearing/worn out unserviceable shaft/burned out copper winding /worn out strainer/bush/sleeve/thrust pad/thrust bearing/thrust bearing lock nut etc including transportation complete all as specified and as directed.Note :- (i) The quoted shall be inclusive of transportation of pump set from pump house site to workshop and back to pump house site after necessary repairs.(ii) The quoted shall be inclusive of balancing of shaft through lathe work incl welding wk if any required as per requirement, replacement of wornout nut, bolts, washers etc complete.(iii) Winding shall be measured and paid separately. 163 All as per serial item number 50.00 here-in-before but of capcity 3 to 5 HP 164 Material and labour for rewinding the non-clog motor of10HP to 15 HP capacity by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new PVC insulated copper wire of existing gauge and size / turns, balancing of shaft, testing as per the specified RPM at workshop complete including replacement winding oil and oil seal complete all as specified and as directed. 165 All as per serial item number 52.00 here-in-before but of capcity 3 to 5 HP 166 Supply and fix in repair following parts for existing nonclog pump set electric driven 3 phase 415 volt 10 HP to 15 HP complete all as specified and directed. 167 Pump bearing Make : SKF/NBC/TATA/FAG/ UBC. 168 Pump bush 169 SS sleeve 170 CI impellaras per existing model 171 Pump shaft 172 Shaft seal of existing size 173 Supply and fix in repair following parts for existing submersible pump set electric driven 3 phase 415 volt 3 HP to 5 HP complete all as specified and directed:- 174 Pump bearing Make : SKF/NBC/TATA/FAG/ UBC. 175 Pump bush 176 SS sleeve 177 CI impellaras per existing model 178 Pump shaft 179 Shaft seal of existing size 180 Supply and fix in repairs PVC insulated 3 core 4 Sqmm copper multistranded PVC sheathed flexible cable suitable for Non clog motor ISI marked and conforming to IS : 694 and connecting to submersible pump with water proof jointing kit and to LT panel with lugs after taking out old unserviceable cable complete all as specified and as directed. 181 Supply and fix in repairs PVC insulated 3 core 10 Sqmm copper multistranded PVC sheathed submersible flexible cable ISI marked and conforming to IS : 694 and connecting to submersible pump with water proof jointing kit and to LT panel with lugs after taking out old unserviceable cable complete all as specified and as directed. 182 All as per serial item number 57.00 here-in-before but 3 core 16 Sqmm 183 Material and labourfor taking out NRV of 100mm/150mm dia from open well including taking column pipe of any size and length, disconnecting of NRV from column pipe, reconnecting of NRV after servicing/repairing, lowering of NRV duly connecting the column pipe, replacement of worn out nut, bolts, washers etc complete all as specified and directed.Note :- The quoted rate shall be inclusive of necessary T&P required for lifting and lowering of NRV from open well/neccessary drain out of water as required as per site requirement. 184 Supply, fixing, jointing and testing of100mm Cast iron Non Return valve without by pass arrangement , Swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete including taking out unserviceable NRVcomplete all as specified and as directed for following sizes of pipe:-Note:-(i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.(ii) The quoted rate shall be inclusive of taking out GI/MS/HDPE pipe from open well, disconnecting of unserviceable NRV, replacement of unserviceable nut, bolts, washers etc, lowering of pipe duly assembleed the new NRV etc complete.(iii) The quoted rate shall be inclusive of T&P required for taking out column pipe of any capacity and size of any length from open well. 185 All as per serial item number 60.00 here-in-before but150 mm bore 186 Supply and fix in repair MCCB 3 pole , 415 volts , fixed thermal and fixed magnetic setting 63 Amps to 100 Amps with braking capacity 16 KA, Ics=100% Icu, complete including replacement of u/s lugs, spreader connector complete all as specified and directed. 187 All as per serial item number 62.00 here-in-before but 125 Amps , with breaking capacity 16 KA. 188 Supply and fix in repair MCCB 4 pole , 415 volts , fixed thermal and fixed magnetic setting upto 160 Amps with braking capacity 16 KA Ics=100% Icu, complete including replacement of u/s lugs, spreader connector complete all as specified and as directed. 189 All as per serial item number 64.00 here-in-before but 200 Amps , with braking capacity 35 KA. 190 All as per serial item number 64.00 here-in-before but 250 Amps , with braking capacity 35 KA. 191 All as per serial item number 64.00 here-in-before but 400 Amps , with braking capacity 35 KA. 192 Supply and fix in replacement of start push button of Green colour as per site requirement all etc complete all as specified and directed. 193 Supply and fix in replacement of stop push button of Red colour as per site requirement all etc complete all as specified and directed. 194 Supply and fix in replacement of motor ON indiating light of green colour as per site requirement all etc complete all as specified and directed. 195 Supply and fix in replacement of motor Trip indiating light of yellow colour as per site requirement all etc complete all as specified and directed. 196 Supply and fix in replacement of neon LED light of Red/Yellow/Blue colour as per site requirement all etc complete all as specified and directed. 197 Supply and fix in replacement of rotary type selector switchall etc complete all as specified and directed. 198 Supply and fix in repairs Power contactorFP AC-1 duty with 240 VAC Coil of capacity 400 Amps (MCX 43) with add-on aux contacts 2 NO+2 NC -01 Nosincl with all necessary internal electrical connections and taking out unserviceable all etc complete all as specified and directed. 199 Supply and fix in repairs Power contactorFP AC-1 duty with 240 VAC Coil of capacity 325 Amps (MCX 41) with add-on Aux contact 2 NO+2 NC -01 Nosincl with all necessary internal electrical connections and taking out unserviceable all etc complete as specified and directed. 200 Supply and fix in repairs Power contactorFP AC-1 duty with 240 VAC Coil of capacity 16 Amps (MCX 01) incl with all necessary internal electrical connections and taking out unserviceable all etc complete as specified and directed. 201 Supply and fix in repairs Power contactorTP AC-3 duty with 240 VAC Coil of capacity 160 Amps (MNX 140) with add-on blocks 1 NO+1 NC -02 Nosincl with all necessary internal electrical connections and taking out unserviceable all etc complete as specified and directed. 202 Supply and fix in repairs Power contactor TP AC-3 duty with 240 VAC Coil of capacity 100 Amps(MNX 70)incl with all necessary internal electrical connections and taking out unserviceable all etc complete as specified and directed. 203 Supply and fix in repairs Power contactor TP AC-3 duty with 240 VAC Coil of capacity 22 Amps (MNX 22) with add-on blocks 1NO/1 NC -01 Nosincl with all necessary internal electrical connections and taking out unserviceable all etc complete as specified and directed. 204 Supply and fix in repairs Power contactor TP AC-3 duty with 240 VAC Coil of capacity 12 Amps (MNX 12) with add-on blocks 1NO/1 NC -01 Nosincl with all necessary internal electrical connections and taking out unserviceable all etc complete as specified and directed. 205 Supply and fix in repairs auxiliary contact block MNX A2,1 No 1 NC incl with all necessary internal electrical connections and taking out unserviceable all etc complete as specified and directed. 206 Supply and fix in repairs add-on auxiliary contact block 1 NO + 1 NC suitable for MNX / MCX type contactors including necssary internal electrical connections all etc complete as specified and directed. 207 Supply and fix in repairsthermal overload relay of capacity 135-225Amps (MN-12)with all necessary internal electrical connection and taking out unserviceable all etc complete as specified and directed. 208 Supply and fix in repairsthermal overload relay of capacity 60-100 (MN-12) Amps with all necessary internal electrical connection and taking out unserviceable all etc complete as specified and directed. 209 Supply and fix in repairsthermal overload relay of capacity 45-75 (MN-5) Amps with all necessary internal electrical connection and taking out unserviceable all etc complete as specified and directed. 210 Supply and fix in repairsthermal overload relay of capacity 4.5-7.5 (MN-2) Amps with all necessary internal electrical connection and taking out unserviceable all etc complete as specified and directed. 211 Supply and fix in repairs repairs Single Phasing Preventer Relay type VSP-II, 415V including necessary internal electric connection with size copper wire complete all as specified and directed. 212 Supply and fix in repairs electronic timer for star-delta time delay 30 to 120/3 to 30 seconds all as per existing sample complete including internal electric connection with suitable size copper wire all as specified and as directed. 213 Supply and fix in repair ammeter 415 volt, 3 phase digital typeincluding necessary internal electric connection with suitable size copper wire & modification required for fitment as per site requirement complete all as specified and as directed. 214 Supply and fix in repair voltmeter 415 volt,3 phase 0 to 500 volts rating, analog type including necessary internal electric connection with suitable size copper wire & modification required for fitment as per site requirement complete all as specified and as directed. 215 Supply and fixing in repairs 240V, 10KA C curve miniature circuit breaker (MCB) ofsingle pole and 6 Amps to 32 Ampscurrent carrying capacity in the MCB DB/LT starter panelcomplete with connection testing and commissioning. 216 Supply and fixing in repairs 415V 10KA C curve miniature circuit breaker (MCB) of TPN and16 Ampsto 32 Amps current carrying capacity in the DB/LT starter panelcomplete with connection testing and commissioningcomplete all as specified and directed. 217 Supply and fixin repairs DOL starter in sheet metal enclosure max motor output at 415 Volt, 3 phase, 7.5KW,relay range 9-15 Amps complete all as specified and as directed. 218 Supply and fixing in replacement of terminal strip6 way all etc complete including electrical connection all as specified complete all as specified and as directed. 219 Supply and fixing in replacement of terminal strip 3way all etc complete including electrical connection all as specified complete all as specified and as directed. 220 Material and labour for preparation of old painted surfaces of centrifugal pump set of 70/75 HP capacity and applying two coats ofsynthetic enamel paint over a coat of red oxide primer complete all as specified and as directed 221 All as per serial item number 96.00 here-in-before but of capacity 60 HP 222 All as per serial item number 96.00 here-in-before but of capacity 20/15 HP 223 All as per serial item number 96.00 here-in-before but of capacity 5/3/2 HP 224 Labour only for attending of Electric compliantsof existing water supply Pump house panels /Borewells LT Panels/CF Motors/Subemrsible moters/Non-clog motors/Horizontal submesible , including connecting electrical accessories / spares of water supply installation, electrical fitting & short circuits in Pump house panel/CF Motors/Submersible motors/ Panelscomplete all as specified and directed. (Any material required for attending complaints shall bemeasured & paid separately under respectvie item of this schedule)Note :-(i)The complaints shall be attended and the defects shall be rectified by a team of expert and experiencedelectrician as applicable assisted with adequate No of helpers as directed by Enginner-in-charge.(ii)The complaints shall be attended and defect shall be rectified within 08 hrscommencing from date and time of notifying the complaint failing which a penalty @ Rs 250/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractors dues.Contractor rep shall be available wef 0800 hrs to 2000 Hrs to receive and notify the complaint (iii)In case, after checking and attending the defect, it is not possible to rectify the defects within 08 hrs the facts shall be brought to the notice of Engineer-in -charge by the contractor /his rep . If Engineer -in-charge is satisfied with contractors view, no recovery will be made.(iv)Any types of machinery/, T & Prequired for attending the complaints shall be provided by the contracor. The quoted rate shall be inclusive of replacement of burnt out lugs, refreshing of burnt out cable, reconnecting, meggering, fault locating etc complete.(v)The elecrician shall always be in possession of all Electrician tools, LT Megger, Earth tester , Multimeter , Crimping tool, insulation tape, Hand gloves etc required at site. 225 Material and labour in repairs for construction of valve pit chamber in PCC (1: 5 : 10) masonry built in CM (1 :4) with 3.00 thick and locking arrangement including excavation and earth works , PCC (1:4:8) type D2 for foundation PCC bed , coping in cement concrete (1:2:4)type B1, plastering 15 mm thick in CM (1:4) , MS doorwith painting with one coat of bituminous black paint on all steel surface for size of chamber 1000 mm x 1000mm x 1200 mm including demolition of unserviceable damaged existing pit complete all as specified and as directed. 226 Supply and fix in replacement of nylon rope of anysize as per site requirement including taking out old unserviceable all etc complete as specified and directed. 227 Material and labour in repairs for Earthing complete with copper earth plate electrode 60×60cm ×3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected to copper earth strip of 20x3.15mm (upto 7.5m in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 including charcoal, rock salt, necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40mm thick cover with MS bar 8mm dia 150mm c/c reinforcement, watering funnel, 32mm dia light grade for protection of earth electrode, 20mm dia for watering complete all as specified and directed and tested on completion. 228 Material and labour in repairs for Earthing complete with galvanised earth plate electrode 60×60cm ×6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected to GI earth strip of 32x6mm (upto 7.5m in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 including charcoal, rock salt, necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40mm thick cover with MS bar 8mm dia 150mm c/c reinforcement, watering funnel, 40mm dia light grade for protection of earth electrode, 20mm dia for watering complete all as specified and directed and tested on completion. 229 Material and labour for repairs of Mild Steel Structure with framed work such grills, gratings etc with ends of bars shouldered and/or rivetted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work, portions framed and hung gates, including pintle hinges, stops, hand made sliding bolts etc as conforming to Fe290, Gde E-165 including two coats of paints of approved colour and including one coat of red oxide primer complete all as specified and directed. 230 Material and labour for in repairs of Precast cement concrete block (1:3:6), type B1 (uising 20mm graded aggregate) exceeding 10 cm in width and setting in mortar 1:6 complete all as specified and directed. 231 Material and labour for 15mm thick rendering in CM 1:4 on block masonry surface even and smooth without using extra cement mortar all as specified and directed. 232 Material and labour for Precast cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) including necessary form work finishing even and smooth without using extra cement complete all as specified and directed. 233 Material and labour for removing existing PCC foundation after taking out pump motor of capacity 60 HP /70 HP from base frame, disconnecting suction, delivery lines and providing new PCC foundation and MS base plate of existing type, size and thickness including foundation bolts all etc complete all as specified and directed: 234 All as per serial item number 109.00 here-in-before but of capacity 15 HP monoblock pumpset 235 Material and labour for installation of pumpset of capacity 60/70 HP on New PCC foundation and fixing with new bolts and nuts for base plate, fabricating to suction, delivery and priming line and connecting with existing lines, connecting power supply and testing, commissioning of pump set complete all as specified and directed 236 All as per serial item number 111.00 here-in-before but of capacity 15 HP monoblock pumpset. 237 Supply and fixin repairs of delivery HDPE hose pipe of size 65/50mm dia and length 30 mtrs with new SS connectors nut bolts, nylon rope of length 5 mtrs by lifting of submersible mud pump of capacity 5 / 7.5 HP from SWT/open well by disconnecting electrical connection and lowering of pump set duly connecting the new hose HDPE pipe and electrical connections, testing on completion all etc complete as specified and directed.

Key Value

Document Fees
INR 500 /-
Tender Value
INR 25 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail