| 1 | CIVIL WORKSProviding of all materials, carting from site store to site of work, laying & jointing of G.I. screwed pipes (including supply of all jointing materials like specials, white lead, hemp and oil etc.) in trenches with its cutting, threading and testing of pipe line etc complete. |
| 2 | 100mm dia |
| 3 | Providing of all materials, Carting from site store to site of work,Lowering into trenches with true to alignment, Laying of APIPipes confirming to API 5L/ ISO: 3183 X-65 Grade , Jointingby electric welding process with proper grade ofeletrodes suitable for jointing of water supply pipe lines (Ador,L&T or equivalent quality of electrodes) by cutting of pipes and making required bends by welding, completion of work with testing of pipe line etc complete. |
| 4 | 65mm dia and 4.00mm thickness |
| 5 | Excavation of earth for pipe line in following strata lift upto 1.5 m. Lead upto 30 m. Including refilling, watering, ramming of excavated earth into the trenches and removal of surplus earth upto a distance of 60 m. From trenches including supply of labour, T&P. etc complete. Assuming that 90% pipe line is laid in trenches & 75% in soil mixed bolder and 25% in soft rock. |
| 6 | In soil mixed bolder |
| 7 | In soft rock |
| 8 | Construction of 2.00m wide briddle path for carting of API Pipe,DG set ,welding machine etc,for laying & jointing of Rissing Main . |
| 9 | Construction of 7.00m x 5.00m x 3.60m size Pump House including supply of all materials labour , cartage , T&P etc complete in all complete. |
| 10 | Construction of type-I staff quarter for operater cum chaukidar including supply of all material labour, cartage, T&P etc complete in all complete. |
| 11 | Supply, cartage, lowering them in to the trenches, laying true to alignment and gradient, jointing and fixing with pipe line including cutting and threading making up lengths as required for proper completion of work with the following fittings including cartage of materials, labours, T&P etc complete. |
| 12 | Sluice Valve ( PN -1.0) as per IS 778/2000 |
| 13 | 100mm dia |
| 14 | Non Return Valve (PN -1.6) (T.P.-10 kg/Sqcm) |
| 15 | 65 mm dia |
| 16 | Scour /Sluice valves (PN-1.6) as per I S 778/2000 |
| 17 | 65 mm dia |
| 18 | High head cast steel air valves |
| 19 | 15mm dia (T.P.- 16 kg/Sqcm) (PN 1.6) |
| 20 | Providing and fixing Multijet domestic mechanical Water Meter Class-B, dry dial, magnetically coupled, temper proof confirming to IS: 779-1994 or ISO: 4064 IP68 in position including all material, labour, T&P etc complete. |
| 21 | Supply of all materials, labours, T&P etc and construct Anchor / Thrust blocks having size of (0.90m x 0.90m x 0.88m )in Rissing Main as per type design complete |
| 22 | Supply of all materials, labours, T&P etc and construct Non Return/Sluice/ Reflux/Scour/Air Valve Chamber having Size (0.60m x 0.60m x 0.98m)in Gravity Main & Rissing Main as per type design complete. |
| 23 | Supply of all materials, labours, T&P etc and construct Gate Valve Chamber having size of (0.45m x 0.45m x 0.80m ) as per type design complete. |
| 24 | Providing and Fixing G.I Chain Link Fabric Fencing of required width in mesh size 50 x 50 mm including strengthening with 2mm dia. Wire or nuts , boltsand washer and Angle iron post 50x50x6mm & strut of required size with proper Excavation work & PCC 1:2:4. |
| 25 | Excavation of earth in foundation in soil mixed with shingle, bajri etc., including lift upto 1.5 m and lead upto 50 m. filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and disposal of surplus earth upto a distance of 50m. from the centre of the foundation trenches, incl. labour, T&P etc. all complete. |
| 26 | Same as above but in ordinary rock (25% of the total excavation) |
| 27 | P.C.C. in 1:4:8 with cement, local sand and 40mm gauge stone ballast including supply of material, labour, T&P etc. for proper completion of work. |
| 28 | R.C.C. in stabs, 1:1.5:3 with cement, coarse sand & 20 mm gauge stone ballast but excluding supply of reinforcement and its bending but including its fixing and binding the same with .5mm thick binding wire and including necessary centering and shuttering and including supply of all material, labour, T&P for proper completion of work. |
| 29 | Mild steel or iron work in plain work such as R.C.C. work wrought to required shape including supply of steel & its bending. |
| 30 | Centering and shuttering including strutting, propping etc. and removal of form work. |
| 31 | For lean concrete |
| 32 | For wall concrete |
| 33 | Construction of RCC Intake Chamber having Size (1.00m x 1.00m x 1.50m ) size at tapping point of source work including supply of all materials ,labour,T&P etc.complete, |
| 34 | Construction of 250 KLD R.C.C Slow Sand Filter including Provision for prepairing & vetting of structural and hydraulic design & drawing ,Bearing Capacity test of soil , supply of all materials ,labour T&P etc. complete in all respect including following works- |
| 35 | Excavation works for (Site Development & Foundation ) In Soil mixed with boulders & bajari @50% |
| 36 | In medium rock @ 50% |
| 37 | Providing and Laying PCC 1:4:8 work. |
| 38 | R.C.C. work with cement concrete with cement,sand & 20mm gauge gravel aggregate coarse in proportion 1:1.5:3 including binding wire and centering& shuttering supply of all materails ,labour T&P etc. required for proper completion of work. |
| 39 | Mild steel and Medium Tensile Steel Bars |
| 40 | Centering and shuttering including strutting, propping etc. and removal of form work. |
| 41 | For Base & Foundation |
| 42 | For wall |
| 43 | Finishing walls with water Proofing cement paint (Two or more coats applied @ 3.84kg/10 sqm) |
| 44 | Supply & fixing of 63 mm dia (OD) NB PVC ribbed stainer 3 mtr long with 1 mtr long PVC blind pipe 10 kg/cm2 including PVC rubber shocket 63X50 mm dia as per german specificationDIN 4925 part-I confirming to IS:-12818 using in palm pressure method & labour etc. |
| 45 | Supply & fixing of sluice valve (gate) for inlet suction pipesincluding supply of all materials, labour T&P etc requried for proper completion of work 100 mm dia . |
| 46 | Providing & laying of sand, gravel and boulder over stainer pipe for media including supply of all materials, labour T&P etc. complete in all respect . |
| 47 | Provision for preparing & vetting of structural and hydraulic design & drawing ,Bearing capacity test of soil etc. |
| 48 | Supply of all materials, labour, T&P etc and construction of R.C.C. Sump / CWR of following capacities (KL) with M.S. ladder outside & inside of the tank, M.S.M.H. cover with locking arrangement, supply and fixing of chlorinator, cowl,outlet, over flow and wash out pipes with necessary sluice valves, pipe pieces (including cost of materials) flooring 0.60 M wide apron, painting with approved water proofing (apex) / enamal paint, testing, filling water for testing purpose etc. including supply of verticalpipes and specials, assuming bearing capacity as 8MT/M2 . |
| 49 | 60.00 KL SUMP |
| 50 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level1:2:4(1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 51 | Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD specifications. |
| 52 | Random Rubble Stone Masonry laid Dry, in breast walls, retaining walls, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specification. |
| 53 | Cleaning of Grass Removal of the rubbish upto a distance of 50m .Outside the peryphery of the area cleared. |
| 54 | E&M Supply of electric driven horizontal centrifugal foot mounted pumpcapable of delivering 130 lpm discharge of Clear water against a total head of 150 mtr,speed 2900 RPM complete with coupling & coupling guards. (1 Nos. Running & 1 Nos. as Standby) |
| 55 | Supply ofTEFC Electric Motor 10HP suitable to operate on 415 ± 10% Volts, 3 Phase, 50 Hz AC Supply for above pump. |
| 56 | Supply of MS Fabricated heavy duty base plate for mounting above Pump & Motor. |
| 57 | Supply of power wiring material such as 10 sq.mm. 3½ Core armouned. Aluminium conductor XLPE insulated cable. |
| 58 | Supply of power wiring material such as 6 sq.mm. 3 Core copper conductorinsulated cable. |
| 59 | Jointing material for wiring connection including lugs, thimble, insulation tapes, nutt bolts etc. |
| 60 | Double loop earting of all electrical equipments with supply of material such as copper earth strip,copper earth plate, G.I. funnel, charcoal, Salt, watering pipe etc. including digging of pits and refilling complete. -1 Job |
| 61 | Main Piping and Valves as per site Requirements |
| 62 | Supply of Gauges as per site Requirements |
| 63 | Tools |
| 64 | Supply of lifting tackle 2 Ton capacity with 4.5 mtr lift |
| 65 | Supply of rubber resistance sheet of size 1m x 2m x 2.5 mm as per IS 15652:2006 |
| 66 | Spare VFD for 10 HP motor |
| 67 | Supply of Fire Extinguisher |
| 68 | Installation and setting to workof entire equipment including pumps, motors, control panel cum starter and power wiringetc. |
| 69 | Commissioning of pumping plant at site. |
| 70 | Testingat works. |
| 71 | Testingat Site. |
| 72 | Painting on pipes and speciales. |
| 73 | Internal Electrfication of pump house |
| 74 | 10 HP VFD(1W+1S) Panel with APR & GSM/GPRS based PLC with analog and digital parameters and features as specified to store and transmit data on GSM backbone. PLC designed with logic to transfer data at multiple stations and also compatible to satellite communication for 2 Pumps. (with 7” HMI) |
| 75 | GSM/GPRS SIOT (Smart Internet of Things) based wireless communication hardware for PLC capable to transfer data from remote site to LCS including all accessories. |
| 76 | Smart Energy meter suitable for automation |
| 77 | Isolation Transformer (440 V step down 220 V) for protection of PLC & instruments from high voltage and low voltage. |
| 78 | Pressure transmitter |
| 79 | Level sensor for Sump (capacitance type) |
| 80 | SITC of Control Cabling of all equipment for SCADA Automation. |
| 81 | Installation, testing & Commissioning. |
| 82 | Running Maintinance of automationsystem for 6 month |