| Sl. No. | Item Description |
| 1 | Description |
| 2 | boq of outer boundary Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 3 | Providingandlayinginpositioncement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 4 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 6 | 15 mm cement plaster on rough side of single or half brick wall ofmix:1:6 (1 cement: 6 coarse sand) |
| 7 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 1.43 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) |
| 8 | Steel work in built up tubular (round, square or rectangular hollow tubesetc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding andbolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 9 | boq of gateways Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: |
| 10 | Providingandlayinginpositioncement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 11 | Providing and laying in position specified grade of reinforced cement concrete,excludingthecostofcentering,shuttering,finishingand reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 12 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 13 | Steel reinforcement for R.C.C. work including straightening,cutting,bending,placingin position and binding all complete upto plinth level.Thermo-MechanicallyTreatedbarsof grade Fe-500D or more. |
| 14 | Centering and shuttering including strutting, proppingetc.andremovalofformforall heights:Foundations,footings,basesof columns, etc. for mass concrete |
| 15 | Suspended floors, roofs, landings, balconies and accessplatform |
| 16 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 17 | New work (Two or more coats applied @ 1.43 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) |
| 18 | boq of 25 year signage Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil |
| 19 | Providingandlayinginpositioncement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 20 | Providingandlayinginpositionmachine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the costofcentering,shuttering,finishingand reinforcement,includingadmixturesin recommended proportions as per as per clause 1500 & 1700 of MoRT&H specification including all material, labour, machinery .“(Note :- Cement content considered in thisitemis@330kg/cum.“Excess/less cementusedasperdesignmixis payable/recoverableseparately).Allworksabove plinth level upto floor V level |
| 21 | Steel reinforcement for R.C.C. work including straightening,cutting,bending,placingin position and binding all complete upto plinth level.Thermo-MechanicallyTreatedbarsof grade Fe-500D or more. |
| 22 | Centering and shuttering including strutting, proppingetc.andremovalofformforall heights:Foundations,footings,basesof columns, etc. for mass concrete |
| 23 | Suspended floors, roofs, landings, balconies and accessplatform |
| 24 | Coursed rubble masonry (second sort) with hard stone in foundation & plinth with : |
| 25 | Coursedrubblemasonrywithhardstone(firstorsecondsort)in superstructure above plinth level and upto floor five level.7.8.1 Masonry work (first sort), in cement mortar 1:6 (1 cement : 6 coarse sand) |
| 26 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 27 | 15 mm cement plaster on rough side of single or half brick wall ofmix:1:6 (1 cement: 6 coarse sand) |
| 28 | 12.52 Providing and fixing tiled false ceiling of specified materials of size595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for allheightsasperspecifications,drawingsandasdirectedbyEngineer-in-charge.12.52.3 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVCfilmonthefacesideand12micronmetalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile acompletely sealed unit. |
| 29 | installation of pvc ward latter with led light |
| 30 | Providingandfixing18mmthickgangsawcut,mirrorpolished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade |
| 31 | boq of naula water point Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: |
| 32 | Providingandlayinginpositioncement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 33 | Coursed rubble masonry (second sort) with hard stone in foundation & plinth with :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 34 | Coursed rubble masonry (second sort) with hard stone in foundation & plinth with :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 35 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 36 | Steel reinforcement for R.C.C. work including straightening,cutting,bending,placingin position and binding all complete upto plinth level.Thermo-MechanicallyTreatedbarsof grade Fe-500D or more. |
| 37 | Suspended floors, roofs, landings, balconies and accessplatform |
| 38 | Providingandfixing18mmthickgangsawcut,mirrorpolished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade |
| 39 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1stquality conforming to IS : 15622, of approved make, in colours White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matchingpigments etc., complete. |
| 40 | Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) :Anodised aluminium (anodised transparentor dyed to required shade according to IS:1868, Minimum anodic coating of grade AC15) |
| 41 | For shutters of doors, windows & ventilators includingproviding and fixing hinges/ pivots and making provisionfor fixing of fittings wherever required including the costof EPDM rubber / neoprene gasket required (Fittingsshall be paid for separately).21.1.2.1:-Anodised aluminium (anodised transparentor dyed to required shade according to IS:1868, Minimum anodic coating of grade AC15) |
| 42 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 43 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps,i/c making good the walls etc. concealed pipe, including paintingwith anti corrosive bitumastic paint, cutting chases and making goodthe wall :15 mm dia nominal bore |
| 44 | 20 mm dia nominal bore |
| 45 | Providing and fixing C.P. brass bib cock of approved quality conformingto IS:8931 :15 mm nominal bore |
| 46 | Providing and fixing C.P. brass stop cock of approved quality conformingto IS:8931 :15 mm nominal bore |
| 47 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work.65 mm nominal inner dia Pipes |
| 48 | Providing and fixing rectangular high density polyethylene waterstorage loft tank with cover, conforming to ISI : 12701, colour ofopaque white or as approved by Engineer-in-charge. The rate includesmaking necessary holes for inlet, outlet & over flow pipes. The basesupport i/c fittings & fixtures for tank shall be paid separately. |
| 49 | Supply and installation of RO Purifire with genset along . |
| 50 | Supply and Installation of 15LPH Water Cooler |
| 51 | boq of bench Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: |
| 52 | Providingandlayinginpositioncement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 53 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 54 | 15 mm cement plaster on rough side of single or half brick wall ofmix: |
| 55 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1stquality conforming to IS : 15622, of approved make, in colours White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matchingpigments etc., complete. |
| 56 | boq of children parkConcrete with cement, coarse sand and 40 mm gauge stone ballast in proportion 1:4:8 in foundations and floors including supply of all material, labour and T&P etc. requiredforpropercompletionofthework.asperdrawingsandtechnical specifications Clause 802, 803, 1202 & 1203 |
| 57 | formwork (Steel channel, laying and fixing of wedges, steel plates including levelling the formwork and laying and fixing of 125 micron thick polythene film, as per drawing), spreading the concrete with shovels, rakes, compacted using needle, and plate vibrators, finished in continuous operation and curing of concrete slabs for 14 days, using curing compound where specified and water finishing to lines and grade as per drawings and technical specifications. |
| 58 | Providing and laying of factory made colured Rubber molded anti- skid short blast concrete block of M-10 Grade having thickness 80mm over 30mm thick sand bed in footpath ,park,lawns, drive ways parking etc. of required strength, thickness & size/ shape , as per drawing & approved by Engineer incharge complete in all respect. |
| 59 | Supply and Installtion of Spiral Surface Slider ( KIDSPLAY Outdoor Slide with Curved (Spiral) design surface made of FRP Material) |
| 60 | Supply and Installation of Straight Surface Slider(Wonderplay outdoor slidewith straight design surface made of HDPE Material) |
| 61 | Supply and Installation of swing- 2 seater(play global garden swing with seat without roof-2 seater) |
| 62 | supply and Installation of Spring rider duck(leo Spring Rider for Children aged 3 yr to 6 yrs) |
| 63 | Supply and Installation of Merry Go Round(ParthFiber Seated Merry Go Round Without Plateform With Total Children Capacity -4) |
| 64 | boq of walkways Concrete with cement, coarse sand and 40 mm gauge stone ballast in proportion 1:4:8 in foundations and floors including supply of all material, labour and T&P etc. requiredforpropercompletionofthework.asperdrawingsandtechnical specifications Clause 802, 803, 1202 & 1203 |
| 65 | Cement Concrete (PCC M-30) Pavement:Construction of Un-reinforced, Cement concrete pavement, thickness as per design, over a prepeared sub base with 43 grade cement or any other type PCC Grade M-30, coarse and fine aggregates conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less then 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (Steel channel, laying and fixing of wedges, steel plates including levelling the formwork and laying and fixing of 125 micron thick polythene film, as per drawing), spreading the concrete with shovels, rakes, compacted using needle, and plate vibrators, finished in continuous operation and curing of concrete slabs for 14 days, using curing compound where specified and water finishing to lines and grade as per drawings and technical specifications. |
| 66 | Providing and laying of factory made colured Rubber molded anti- skid short blast concrete block of M-10 Grade having thickness 80mm over 30mm thick sand bed in footpath ,park,lawns, drive ways parking etc. of required strength, thickness & size/ shape , as per drawing & approved by Engineer incharge complete in all respect. |
| 67 | boq of horticulture Grassing with \" Doobs\" Grass (Grassing with \"Doobs\" grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed).In rows 7.5 cm apart in either direction |
| 68 | a) Planting Permanent Hedges including Digging of Trenches (Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum per 100 metres and supplying and planting hedge plants at 30 cm apart) |
| 69 | Planting Flowering Plants and Shrubs in Central Verge |
| 70 | Planting of Trees and their Maintenance for one Year(Planting of trees by the road side (Avenue trees) in 0.60 m dia holes,1 m deep dug in the ground,mixing the soil with decayed farm yard/sludge mannure,planting the saplings,backfilling the trench,watering,fixing the tree guard and maintaining the plants for one year) |
| 71 | Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separatel |
| 72 | Mali ( maintenance of topiary statue and park)- 1year(365 day) |
| 73 | boq of vending cart Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 74 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 75 | unbranded Cast Iron Wheel, |
| 76 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 77 | Providing and fixing chromium plated brass handles with necessary screws etc. complete: |
| 78 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : |
| 79 | boq of electrical Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess. including providing and fixing 6 pin 5/6 A & 15/16 A modularsocket outlet and 15/16 A modular switch ,connection etc. as required |
| 80 | Supplying and fixing 5A to 32Arating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete withconnections, testing and connmissioning etc. as required. Single pole |
| 81 | Supplying and fixing following modular switch/ socket on the existing modularplate & switch box including connections but excluding modular plates etc. as required.5/6 A switch |
| 82 | 6 pin 15/16 A socket outlet |
| 83 | ollvin PVC Insulated copper cable single and multi- cicular sheathed cable with flexible conducture as per is:694(version -2) 4 sqmm,1Core ollvin(4sqmm single copper cable) |
| 84 | surya warm white pvc circular led surface ceilling light (led surface ceiling light 24 watt) |
| 85 | boq of washroom Earth work in excavation by mechanical means (Hydraulic excavator)/manualmeans over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) including getting out and disposal of excavated earth leadupto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. |
| 86 | Fillingavailableexcavatedearth(excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and liftupto 1.5 m. |
| 87 | Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete. |
| 88 | Surface dressing of the ground including removing vegetation and inequalitiesnot exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift up to 1.5 m. |
| 89 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinth.1:4:8 (1 Cement : 3 coarse sand (zone-III): 6 graded stoneaggregate 40 mm nominal size) |
| 90 | 4.1.2 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stoneaggregate 20 mm nominal size) |
| 91 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stoneaggregate 12.5mm nominal size) |
| 92 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishingandreinforcement,includingadmixturesin recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. |
| 93 | All works above plinth level upto floor V level |
| 94 | Centering and shuttering including strutting, propping etc. and removalof form for :Foundations, footings, bases of columns, etc. for mass concrete |
| 95 | Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 96 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 97 | Suspended floors, roofs, landings, balconies and accessplatform |
| 98 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. |
| 99 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 100 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) |
| 101 | 15 mm cement plaster on rough side of single or half brick wall ofmix:1:6 (1 cement: 6 fine sand) |
| 102 | Providingandfixing18mmthickgangsawcut,mirrorpolished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Raj Nagar Plain white marble/ Udaipur green marble/ Zebra |
| 103 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1stquality conforming to IS : 15622, of approved make, in colours White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matchingpigments etc., complete. |
| 104 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., |
| 105 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 106 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 1.43 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) |
| 107 | Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) : |
| 108 | For shutters of doors, windows & ventilators includingproviding and fixing hinges/ pivots and making provisionfor fixing of fittings wherever required including the costof EPDM rubber / neoprene gasket required (Fittingsshall be paid for separately).Anodised aluminium (anodised transparentor dyed to required shade according to IS:1868, Minimum anodic coating of grade AC15) |
| 109 | Providing and fixing glazing in aluminium door, window, ventilator shuttersand partitions etc. with EPDM rubber / neoprene gasket etc. complete asper the architectural drawings and the directions of engineer-in-charge .(Cost of aluminium snap beading shall be paid in basic item): |
| 110 | sanitary work Providing and fixing white vitreous china pedestal type water closet(European type) with seat and lid, 10 litre low level white vitreouschina flushing cistern & C.P. flush bend with fittings & C.I. brackets,40 mm flush bend, overflow arrangement with specials of standardmake and mosquito proof coupling of approved municipal designcomplete, including painting of fittings and brackets, cutting andmaking good the walls and floors wherever required.W.C. pan with ISI marked white solid plastic seat and lid |
| 111 | Providing and fixing white vitreous china flat back half stall urinal ofsize 580x380x350 mm with white PVC automatic flushing cistern,with fittings, standard size C.P. brass flush pipe, spreaders withunions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brass,including painting of fittings and cutting and making good the wallsand floors wherever required : |
| 112 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the wallswherever require: |
| 113 | Sand cast iron S&S as per IS - 1729 |
| 114 | Providing and fixing trap of self cleansing design with screwed downor hinged grating with or without vent arm complete, including cost ofcutting and making good the walls and floors :Sand cast iron S&S as per IS: 3989 |
| 115 | Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 38 mm single piece moulded with height of270 mm, effective length of tail pipe 260 mm from thecentre of the waste coupling, 77 mm breadth with 25 mmminimum water seal, weighing not less than 263 gms |
| 116 | Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape withbracket of the same materials with snap fittings of approved qualityand colour, weighing not less than 105 gms. |
| 117 | Providing and fixing soil, waste and vent pipes :Sand cast iron S&S pipe as per IS: 1729 |
| 118 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. |
| 119 | Constructing masonry Chamber 60x60x75 cm inside, in brick workin cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve,with C.I. surface box 100mm top diameter, 160 mm bottom diameterand 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mmnominal size ) , i/c necessary excavation, foundation concrete 1:5:10(1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominalsize) and inside plastering with cement mortar 1:3 (1 cement : 3coarse sand) 12 mm thick, finished with a floating coat of neat cement.With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 |
| 120 | Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms. |
| 121 | roviding and laying cement concrete 1:5:10 (1 cement : 5 coarsesand : 10 graded stone aggregate 40 mm nominal size) all-roundS.W. pipes including bed concrete as per standard design :Chlorinated Polyvinyl - chloride (CPVC) pipe 100 mm inner dia |
| 122 | S.C.I. gully or nahani grating 100 mm dia |
| 123 | plumbing work & water supply Providing and fixing G.I. Pipes complete with G.I. fittings and clamps,i/c making good the walls etc. concealed pipe, including paintingwith anti corrosive bitumastic paint, cutting chases and making goodthe wall :15 mm dia nominal bore |
| 124 | 20 mm dia nominal bore |
| 125 | Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc. |
| 126 | Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) :25 mm nominal bore |
| 127 | roviding and fixing brass ferrule with C.I. mouth cover includingboring and tapping the main :15 mm nominal bore |
| 128 | Providing and fixing rectangular high density polyethylene waterstorage loft tank with cover, conforming to ISI : 12701, colour ofopaque white or as approved by Engineer-in-charge. The rate includesmaking necessary holes for inlet, outlet & over flow pipes. The basesupport i/c fittings & fixtures for tank shall be paid separately. |
| 129 | Providing and fixing C.P. brass bib cock of approved quality conformingto IS:8931 :15 mm nominal bore |
| 130 | Providing and fixing C.P. brass stop cock (concealed) of standarddesign and of approved make conforming to IS:8931. |
| 131 | Providing and fixing square-mouth S.W. gully trap class SP-1 completewith C.I. grating brick masonry chamber with water tight C.I. coverwith frame of 300 x300 mm size (inside) the weight of cover to be notless than 4.50 kg and frame to be not less than 2.70 kg as perstandard design:With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 132 | boq of septic tank Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. |
| 133 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 134 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 135 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 136 | Foundations, footings, bases of columns, etc. for mass concrete |
| 137 | Suspended floors, roofs, landings, balconies and access platform |
| 138 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 139 | 12 mm cement plaster finished with a floating coat of neat cement ofmix :13.7.1 1:3 (1 cement: 3 fine sand) |
| 140 | boq of electricalwork of toilet Wiring for circuit/ submain wiring alongwith/ earth wire with the following sizes or FRLS PVC insulated copper conductor, single core cable in surface/ recessed nocdiunn class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 141 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 142 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 143 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess. including providing and fixing 6 pin 5/6 A & 15/16 A modularsocket outlet and 15/16 A modular switch ,connection etc. as required |
| 144 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box includingconnections but excluding modular plates etc. as required 5/6 A switch |
| 145 | 6 pin 15/16 A socket outlet |
| 146 | Supplying and fixing 5A to 32Arating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete withconnections, testing and connmissioning etc. as required. |
| 147 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCC13), having a sensitivity current 30 nnA in the existing MCB DB connplelewith connection testing and conunissioning etc. as required. |
| 148 | Earthing with GI earth plate 600mmX 600mmX 6mm thich including accessories and providing masonry enclosure with cover plate having locking arrallgcnnent and watering pipe of 2.7 noeter long etc. with charcoal/ coke and salt as required. |
| 149 | Providing and laying ear(h connection from earth electrode with 6 SWG dia G.l. Wire in 15 mm dia G.l. pipe from earth electrode including connectionwith G.l. thimble excavation and re- filling as required |
| 150 | twilight (autoon, auto off, auto mode) with manual override facility withsuitable battery and indication for relay status i/c progrannnoing at site conoplete as required.2 output per phase and suitable for single phase supply |
| 151 | ollvin PVC Insulated copper cable single and multi- cicular sheathed cable with flexible conducture as per is:694(version -2) 4 sqmm,1Core ollvin(4sqmm single copper cable) |
| 152 | surya warm white pvc circular led surface ceilling light (led surface ceiling light 24 watt) |
| 153 | Boq of other item GAZEBO (WOOD BARN--WOOD BARN INDIA PRIVATE LIMITED 12 Pole Gazebo With Pole Height, 9 foot UR WOOD BARN Unregistered Brand Manufactured by: WOOD BARN INDIA PRIVATE LIMITED (DININGHALLGAZEBO)) |
| 154 | DUSTBIN (Genx outdoor twin waste bins capacity-200 LTR) |
| 155 | WATER FOUNTIAIN (Unbranded Outdoor / Indoor Fountain, Maintainence period 1 year) |
| 156 | SAMBER DEER-6\" HIGHT |
| 157 | DECORATIVE SHEEP-(2\"-6\"\"X4\"-0\"\") |
| 158 | LAMB-(3\"-0\"\"X3\"-0\"\") |
| 159 | DEER SET-6\" |
| 160 | SELFIE KIOSK-(5\"-0\"\"X8\"-0\"\") |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy