| 1 | Site cleaning inside the campus |
| 2 | Dismantling brick or stone masonary in lime or cement mortar above 3m. Height including stacking the useful materials for reuse and removing the debris within 50m. Lead. |
| 3 | Providing fitting and fixing of false ceiling with Aluminium anodised T Section No.3215 with 2\"-0\" center to center, L section No. 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and P.V.C plug and the Aluminium grid 2\"-0\"x2\"-0\"suspended from ceiling etc complete. |
| 4 | Providing and erection of MS Square bar fabricated trusses and purlineas per thedesign approved by dept with hoisting joists and trusses and placing in position. |
| 5 | Iron work wrought and put up in trusses and record racks (Labour only) |
| 6 | Fixing prepainted GCI sheet in roof, fixing in ridges, wind, ties etc, drilling holes in wind ties, cost of L/j hook,nut, bolt,washers and cost of roofing sheet. |
| 7 | Painting two coats with enamel paint on new iron works |
| 8 | Brick work with 1st class FLY-ASH Brick in C.M (1:6) in superstructure of size 10\"x5\"x3\" having cruching strength not less than 75 kg/sqcm inculding cost,conveyance and royalty of materials with labour charge etc complete in all respect in all floors. |
| 9 | C.C.(1:2:4) with 12 mm. size h.g. chips with watering and curing completely |
| 10 | 12mm (1/2\") thick cement plastering in C.M (1:6)finishing smooth to out side smooth surfacefor brick work wall after racking out the joint inculding watering and curing withcost, conveyance & royality and taxes of allmaterials and cost of all labour charge requried for the work etc complete. |
| 11 | Finishing walls with water proofing Cement paint of approved shade on new work two coats to give an even shade including watering and curing complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the worketc. complete as per the direction of the EIC. |
| 12 | Finishing exterior walls with weather coat of approved shade two coats on new work to give an even shade including cost of paints in ground floor.(data for 10sqm) |
| 13 | Air pressure (hydraulic)Door closer withstopper |
| 14 | Supply,fitting and fixing of 1000 litre PVC sintex tank with nipples,short piece, staging all complete with cost, conveyance. |
| 15 | Providing, Supplying and fixing of metal box of 150 mm x 75 mm x 60 mm (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc as required. (For light plugs to be used in non residential buildings) complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, etc. complete as per the direction for the EIC. |
| 16 | Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp, 250 V piano type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex / L&T / Anchor / Havels / V Guard ) complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work,etc. complete as per the direction for the EIC. [Group-C] |
| 17 | Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick alongwith 1 x1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex/ L&T/Anchor /Havels /V Guard) complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work,etc. complete as per the direction for the EIC. |
| 18 | Supply and fixing of single pole MCB with sheet steel enclosure, distribution board, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, phosphate and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ ISOLATOR) complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work,etc. complete as per the direction for the EIC. |
| 19 | Supply and fixing of 5 amp to 32 amp rating 240 V \"B\" series miniature circuit breaker suitable for lighting and other loads of the following poles in the existing MCB DB ISI marked complete with connections testing and commissioning etc. as required complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, etc. complete as per the direction for the EIC. |
| 20 | Supplying, fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @0.90mtr. C/C and stainless square pipe barracking of size 32mm x 32mm x 2m min 3 rows in stair case as per approved design and specification,buffing,polishingetc.withcost,conveyance, excludingGSTofallmaterials,labour,T&Petc.requiredfor the complete in all respect. |
| 21 | Repairing of three nos of existing air conditioners in FIAC,Rairakhol for office use only. LS |
| 22 | Repairing ,washing and development of existing bore well (as per local rate) beside FIAC ,Rairakhol with other PH accessories. LS |