| 1 | Walling of random rubble, uncoursed, Bangalore type masonry (except stone) well bonded bedded solidly hearted built in CM 1:6, extra over stone walling for hammer dressing to face stones and dressing of face beds and joints as specified, key pointing to random or polygonal rubble, uncoarsed or brought upto courses in CM 1:4 and including removal and refixing, built in cement mortar of any description as specified and directed. (Old stones shall be re-used) |
| 2 | M & L in repairs walling of random rubble, uncoursed, Bangalore type masonrywell bonded bedded solidly hearted built in CM 1:6, extra over stone walling for hammer dressing to face stones and dressing of face beds and joints as specified, key pointing to random or polygonal rubble, uncoarsed or brought upto courses in CM 1:4 and including demolition of old brick work / stone masonry/PCC block built in cement mortar of any description as specified and directed. |
| 3 | Racking out joints / points in cement mortar to squared rubber masonry coursed or uncoursed and including M & L keyed pointed in CM 1:4 for squared rubble masonryall as specified and directed. |
| 4 | M & L broken glass coping on top of walls in cement mortar 1:3 incl taking down old glass and removing the rubbish to a distance not less than 100 m and deposited where directed |
| 5 | Note for item No-04: The unit quoted rate deemed to be included for following :- |
| 6 | (a) 25mm thick layer of cement mortar glass (of bottle or thick glass) broken to approximately 63mm gauge, shall be firmly embedded at the rate of 10 Kg of glass per square metre of rendered surface, jogged edges of the glass being left projecting. |
| 7 | (b) Taking down existing glass from coping and removing as directed. |
| 8 | (c) Scaffolding for execution of work and protective measures shall be taken by the contractor without any extra cost to Govt. |
| 9 | S&F in repair galvanised two strand steel barbed wire 2.24mm dia barbed wire with 2 mm barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanised MS wire staples or steelpins etc as directed(each line wire to be measured) |
| 10 | Restraining and resecuring barbed wire including making good staples etc (each line wire to be measured) |
| 11 | S & F in repair concertina coilof 610mm dia (in stretched position) hot deep galvanised steel wire coated with CLR ante corrosive coating making diamond shape with the help of devotail clips (18 SWG) fixed over barbed with the angle iron the concertina coil is to be fixed with barbed wire at points where coil touched the bottom barbed wire with the help of hog rings (14 SWG) complete, incl removal of old unserviceable coil all as specified and directed. |
| 12 | M&Lpre-cast PCC 1:3:6 type C1 (20 mm graded agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:6 including demolition of old brick work / stone masonry/PCC block built in cement mortar of any description as specified and directed. |
| 13 | M&L for rendering 15mm thick in cement mortar (1:6) on brick or concrete surfaces of wall and finished the surface even and smooth without using extra cement complete all as specified and directed. |
| 14 | M&L for machine pressed pre polished precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade except Interlocking tiles. over sand cushion with grey cement and no pigment and including side kerbconcrete, incl removal of old and necessary demolition and all as specified and directed. |
| 15 | M & L for Sand filling under floors or in foundations including watering and consolidation and all as specified and directed. |
| 16 | M&L PCC (1:4:8) type D2 using 40mm graded aggregate 75mm thick as in sub base of floor finished even and rough to receive top layer and all as specified and directed and demolition of old Concrete (un reinforced) of any description and in anypositionnot otherwise specifically provided. |
| 17 | Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m deep along the existing sewage line carefully for placing taking out and getting out in any type of soil complete all as specified and directed. |
| 18 | Excavation in trenchesexceeding 1.50 m deep and not exceeding 3.00 m deep along the existing sewage line carefully for placing taking out and getting out in any type of soil complete all as specified and directed. |
| 19 | Returning and filling soil in layers not exceeding 25cm thick each layer including spreading, leveling, watering and well ramming all as speicified and directed. |
| 20 | Removal of surplus material to a distance not exc 50m and deposited where directred at a level not exc 1.50 m above starting point all as specified and directed. |
| 21 | M & L salt glazed stone ware drain pipes of internal dia 150 mm bore grade \"A\" laid in trenches and jointed in cement mortar incl demolition and breaking up old drain pipe (salt glazed stoneware drain pipe) set in cement concrete, complete all as specified and as directed. |
| 22 | M & L salt glazed stone ware drain pipes of internal dia 200 mm bore grade \"A\" laid in trenches and jointed in cement mortar incl demolition and breaking up old drain pipe (salt glazed stoneware drain pipe) set in cement concrete, complete all as specified and as directed. |
| 23 | M&L reinforced cement concrete pipes 200mm bore, class NP2, laid and jointed in position with collarscomplete all as specified and as directed. |
| 24 | M&L for concrete bed to drain pipe including packing under and haunching against the sides of drain pipe after they are laid and tested in PCC 1:3:6 type C-2 for 150mm dia pipe complete all as specified and directed |
| 25 | M&L for concrete bed to drain pipe including packing under and haunching against the sides of drain pipe after they are laid and tested in PCC 1:3:6 type C-2 for 200mm dia pipe complete all as specified and directed |
| 26 | M&L PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in foundation of manholes, drains, walls and similar works etc, ncluding demolition of existing cement concrete, including disposal of demolished material upto 500mtr MD land complete all as specified and directed. |
| 27 | M & L for precast cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) setting in CM 1:6 work for landings, cover slabs, manholes, chajjas, water troughs, manger shleves and similar articles with plain facesand demolition of old reinforced cement concrete of any description and in any position complete all as specified and directed. |
| 28 | M & L mild steel TMT bar 10mm dia and over cut to length bent shape as required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S complete all as specified and as directed. |
| 29 | M&L for Plain cement concrete 1:2:4 type B1 (20mm graded stone aggregate) as in coping and similar works etc, including removal of old and necessary demolition, complete all as specified and directed. |
| 30 | M&L for Providing 40mm thick Plain cement concrete 1:2:4 type B1 (20mm graded stone aggregate) as in flooring and similar works etc surface finished even and fair without using extra cement, including removal of old and necessary demolition, complete all as specified and directed. |
| 31 | M&L for kerb stone precast with PCC (1:2:4) type B1 using 20mm graded aggregate finished even and fair without using extra cement and all as specified and directed and demolition ofold kerb stone (un reinforced) of any description and in anypositionnot otherwise specifically provided. |
| 32 | M&L for cement concrete 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in surface channel of drain, benching in manhole and wall / drain and similar works etc finished even and smooth with using extra cement ncluding demolition of existing cement concrete, including disposal of demolished material upto 500mtr from MD land complete all as specified and directed. |
| 33 | Cleaning of manholes any size and not exc 1.5m depth including lifting, removing sludge, water with using mechanical instrument and cleaning with water including cutting grass, vegetation and bushes to a width of 60cm all around manholes complete all as specified and directed. |
| 34 | M&L Cleaning/ clearing of sewage line (including manholes) 150 mm to 300 mm dia main line from 1stmanhole onwards bore of any description, underground at any depth, removing any type of blockage including desludging, descaling & decoking of drain as well as manholes with combined high pressure water jetting cum suction (vacuum) type machine mountedon LCV/HCV /LMV/HMV and having facilities of high pressure vacuum and provn of hydraulic through high pressure thermo plastic fiber based water jetting hose and conical round shape nozzle pipe and flushing after cleaning including removing the same out side MD land and deposit where the place marked by the local municipality, complete all as directed. |
| 35 | Attending day to day complaints of different type of sewage work such as removing blockage of WCs, floor traps, Nahani traps, Gully traps, CI/PVC pipes all types any size, any height top to bottom including junction etc complete all as specified and directed. |
| 36 | Cleaning of blockage from nahani traps of bathroom/kitchen/Urinal/toilet in ground floor and upper floors all types any size, any heightby taking out mud/sand incl taking out lid and re-fixing the same complete all as specified and as directed. |
| 37 | Cleaning of blockage from Gully trap to 1st manholes in ground floors, all types any size, any locationby taking out mud/sand incl taking out lid and re-fixing the same complete all as specified and as directed. |
| 38 | Note for item No 35 to 37 :-The unit quoted rate is deemed to be included for the following :- |
| 39 | (a)Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level.Cutting the grass/felling of trees shall include digging out roots up to 60 cm below the ground level or 14 cm below the formation level, whichever is lower. All holes and hollows formed in the ground digging out of roots shall be made good carefully by filled up with moorum/red bajri well rammed and levelled. |
| 40 | (b)Safaiwala shall report to concerned JE /AGE in service centre B&Rdaily including Sunday and holiday and get the job card for carrying out the work. The Job card shall be returnedto concerned JE/AGE duly signed by the users as a token of completion of job. |
| 41 | (c)Cleaning, removal of silts/wastage of organic or inorganic materialsof Sewage line of100mm to 450mm bore up to 1st manhole, in between manholes, GT Chamber, etc to maintain sewage system functional all days including Sundays and holidays along with necessary T&P i.e flexible rods, cleaning pumps and safety kits etc. |
| 42 | (d)The complaints to be rectified within SIX hours on same day. In case of delay in rectification of complaint for more than Six hours, the penalty will be levied @ Rs.100.00 Per complaint/ day. |
| 43 | (e)In case the nature of job is such that the work cannot be completed within a period of 6 hrs then the same shall be brought to the notice of the GE/Engr-in-Charge and the period for the completion of the complaint shall be decided by the GE/Engr-in-Charge. |
| 44 | M&L Cleaning and Removing silt, grit , mud and other materials from covered drain in foul condition including removing materials from the site to outside MD land including necessary removing cover slabs and replacing after cleaning complete area including making good any damages complete all as specified and as directed. Note:- The unit rate is deemed to be included for Removing of accumulated earth at sides of drain of any width and depth up to 30 cm. cleaning/cutting the grass around 1 m from drain (both sides) and removing the grass waste to outside MD land. Cutting and filling shall be cleared of shrubs, vegetation, grass bushes, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level . Cutting the grass/felling of trees shall include digging out roots up to 60 cm below the ground level or 14 cm below the formation level, whichever is lower. All holes and hollows formed in the ground after digging out of roots shall be carefully filled up with moorum/red bajri well rammed and levelled. |
| 45 | Taking out/pumping contaminated sewage water/ sludge from septic tank/soakage well/ incl inlet/outlet chamber after plugin incoming sewage line suction (vaccum) type machine mounted on LMV/HMV and facility of high pressure vaccum and removing and dumping off the same in tank to a place out side contonment at the place marked for the purpose by local municipality or the authority controling the area as directed.Note :- Contractor is advised to ascertain the suitable place earmarked for disposal of sludge/sewage water from local municipality or area controling authority before quoting their rates. Disposal of waste at suitable place shall be sole responsibility of contractor and no representation or objection in this regard shall be entertained at any later stage. |
| 46 | Cleaning of manholes any size and exc 1.5m depth including lifting, removing sludge, water and cleaning with waterusing mechanical instrument including cutting grass, vegetation and bushes to a width of 60cm all alround manholes complete all as specified and directed.Note :the sludge obtained while cleaning shall be removed from the site to outside of MOD land.The rates quoted for items shall include the above provns also. |
| 47 | M&L in repairs 300mmx300mmx25mm thick prepolished cement concrete chequered tiles jointed in neat cement slurry and pointed in white or coloured cement to match the floor and including 20mm thick screed bed in CM 1.4, including removal of old and necessary demolition, all as specified and directed. |
| 48 | M&L for broken stone boulders hard core of guage n.exc 63mm deposited spread and level laid in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 49 | Dismantling posts or struts (wood, steel, or RCC) any section, any length n exc 5m including taking out embedded portion in concrete, brick work, masonry etc and all as specified and directed. and incl neccessary excavation for new post holesall as specified and directed. |
| 50 | M&L for Cement concrete 1:3:6 type C2 (using 40 mm graded stone agg) as in foundation, filling and for mass concrete all as specified and directed. |
| 51 | S & FMS angle iron Hand rails, fencing posts, flat iron including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 52 | Supply only of chain link fencing MS galvanised square wire mesh of size 50mm X 50mm, dia of wire 4mm including line wires, to any type of standard rails, straining bolts, etc all as specified and directed. |
| 53 | Fixing only in repairs chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc inlcuding provision of binding wire and dismantling of old unserviceable fencing wire mesh of any typeetc all as specified and directed. |
| 54 | S&F in repairs MS round bars 10 mm dia and overFe 290 (Gde - E-165) cut to length bent to shape required including cranking, bending spirally, hooping for columns, hooking ends and all as specified and directed. |
| 55 | S &F in repairs Mild steel screw bolts (machine made) dia of neck 16 to 20mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long all as specified and directed. |
| 56 | Running welding in repairs exc 6 mm but n exc 9mm, complete all as specified and directed. |
| 57 | Taking down cement plaster on brick or stone walls, or concreteetc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises and leaving the work clear of any plastering and Material and labour for Rendering 15 mm thick in two layers onbrick or stone or concrete surfaces,first coat 10mm thick in cement mortar1:4 and 2nd coat 5mm thick in cement mortar1:4 finished even and smooth without using extra cement completeall as specified and directed.Note :-(a) The unit rate quotedis deemed to include for removal of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protectionto outside MD land. |
| 58 | Supply only liquid water proofing compound of approved make all as specified and directed. |
| 59 | M&L Preparation of newly plastered surfaces of walls and applying two coats of cement base paint on walls over a coat of alkali resistant primer of any description all as specified and directed. |
| 60 | M&L in repairs Providing precast cement concrete louvres and jallies, 35mm thick (measured solid) set in CM 1:4, type B0 1:2:4, faces are finished smooth including demolition of old mouldings complete all as specified and directed. |
| 61 | Site clearance by Scraping of grass/wild growth/trees cutting n.exc 0.30m girth etc in any type of soil by manually/mechanically including removing of rubbish from the site to a distance exc, 250m but n. exc 500m and deposited where directed at a level not exc. 1.5m above the starting point, complete all as specified and as directed |
| 62 | M & L for 75 mm thick PCC type C1, 1:3:6 (using 20 mm graded aggregate) in plinth protection,finishing the surface even and smooth with using extra cement laid to slope, including necessary demolition of old concrete all as speecified and as directed. |
| 63 | Dismantling structural steel work incl doors, gates but excluding framed trusses etc complete all as specified and directed. |
| 64 | S&Fin framed work as in doors or gates of angle,tubes or other section with gusset plates, rails, braces,guard bar etc., complete, to be prepared for hanging or sliding with and includinghinges or steel hanging door fittings (exclusive of steel sheeting or other covering) and hanging; also fastening and fixing Fe 410 -W (Gde- E- 250) quality-A complete all as specified. |
| 65 | S & F MS Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161-1979 grade St.-240 complete all as specified and directed. |
| 66 | M & L for 0.50mm thick Pre painted Galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of old corrugated AC/fibre/GI sheet of any pattern in roof including ridge complete all as specified and directed. |
| 67 | M & L Providing two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces over 10 cm width or girth including preparation of new steel surfaces all as specified and directed. |
| 68 | M&L for welding in repairs not exceeding 10 Cm length & thickness of metal to be welded not exceeding 6mm complete all as spcified and directed. |
| 69 | S&F Welded steel wire fabric cut to length, bent to shape required and tying with and including annealed mild steel not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel membersnot exceeding 4kg/sqm complete all as specified and directed. |
| 70 | Taking down and refixing precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade over sand cushion with grey cement and no pigment and including side kerb concrete and removal and refixing all as specified and directed. |
| 71 | M&L for preparation of new/old any type ofsurfaces ofany description, over 10 cm width or girth, not otherwise described and applying two coats of floor guard paint complete all as specified and directed. |
| 72 | Note :- An amount of Rs 42,635.00 on account of credit schedule for schedule \"A\" part II shall be deducted from the total amount of BOQ to arrive at the contract sum. |