Tender For Special Repair To Electric Lt Panels, Cables, Pole Etc At Shahjahanpur Cantt Under Ge East Bareilly; 1 Excavation in trenches n. exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying under ground LT XLPEcable and getting soft/loose soil complete all as specified and directed. 2 M&L Returning , filling in including spreading, levelling, watering and well ramming in laying not exceeding 25 cm thick in soft/loose soil completeall as specified and directed. 3 M&L Removing excavated material (soils) to a distance not exceeding 50 m and depositing whare directed at a level not exceeding 1.5 mtr above the starting point completeall as specified and directed. 4 Material and labour for riverfine sand, washedand screened dry for caushioning to under ground cable in trenches below and around under ground cable includingspreading and levellingpunningcomplete all as specified and directed. 5 M&L for laying bricks, sub class B for protection of cable, in trenches, laid in dry flat across the cable with length of whole bricks complete all as specified and directed. 6 Taking down/out old defective cable from trench/floor/road/wall/pipe /pole service connection of any size testing and checking of cable of any material complete all as specified& directed. 7 Supply and laying XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminum conductor 1100 Volts grade of size 150 Sqmm 3.5 core complete all as specified& directed. 8 All as per item no.7 size here in before but 120 Sqmm 3.5 core complete all as specified and directed. 9 All as per item no.7 size here in before but 95 Sqmm 3.5 core complete all as specified and directed. 10 All as per item no.7 size here in before but 50 Sqmm 3.5 core complete all as specified and directed. 11 All as per item no .7 size here in before but 35 Sqmm 3.5 core complete all as specified and directed. 12 All as per item no.7 size here in before but 25 Sqmm 3.5 core complete all as specified and directed. 13 All as per item no.7 size here in before but 16 Sqmm 3.5 core complete all as specified and directed. 14 All as per item no.7 size here in before but 10 Sqmm 4 core complete all as specified and directed. 15 S & F steel tubing GILight grade 32 mm bore for fixing of tapping of incoming and outgoing point complete all as specified and directed. 16 S & F steel tubing GILight grade 40mm bore for fixing of tapping of incoming and outgoing point complete all as specified and directed. 17 S & F in replacement of GI tubing light grade 80mm nominal bore for cable protection fixed with clamps of M.S. Flat iron 25x3mm, GI nuts, bolts and washers to poles/under floor/under roads/alongwith walls including two coats of aluminium paint over a coat of red oxide primer on clamps complete including taking up of old UNSV GI tubing complete all as specified and directed by Engr-in-Charge. 18 M & L for Boring under Road / PCC by using manual tool for inserting, including GI pipe of 80mm size for protection of cable complete all as specified and as directed by the Engineer-In-Charge. 19 M & L for Cutting of existing RCC Floor/PCC/Tiles for electrical cable and supply and fix tube, light grade, galvanised 25mm dia, necessary connection to TPN DB from LT control panel and making good to the disturbed surfaces of floor from RCC includingto match the existing type etc all as directed 20 Supply and fix Junction box cover made of PVC super fine quality fixed to pole connector block din rail suitable size of aluminium bus bar locking arrangement complete all as specified and as directed. 21 M & L aluminum wire withTwo core 2.5 sqmm PVC insulated 1100 volts gradeconnected from Security light to DB/main boardwith PVC conduit complete all as specified and as directed. 22 Taking down/out old defective rusted iron pole from LT line connection of any size testing and checking of cable of any material complete all as specified& directed. 23 Supply and fix in replacement Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0metres long) complete all as specified and as directed 24 M&L Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate for coping around poles, including necessary form work finishing even and smooth complite all as specified and directed . 25 M&L for cement concrete type D2 1:4:8 (40mm graded aggregate) in pole/stay/ plinth etc infoundation filling completed all as directed by Engr-in-Charge. 26 M&Lfor earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick, buried directly in ground, vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI strip 32x6mm dia by means of bolts, nuts, check-nuts and washers of galvanized iron and thimbles and of earth wire protected by galvanizediron pipe light grade 15mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregatein lieu of CI cover and frame etc allas specified and shown in electrical plate No. 3 of SSR-2009 (Part-I). 27 Material & Labour for supply,installing,testing & commissioning of factory madeLT panel outdoor typefor LT distribution switch gear and control gear,floor mounted ,cubical type modular compartment, dust and vermin proof with neoprene gasket fabricated out of CRCA sheet of thick ness not less than 3.15 mm (CPRI Approved) complete with bus bar chamber & cupperBus bar of four wire system 415 volt with heat shrinkableinsulator sleeve suitable for 450 A for phases and for neutral having openable front and rear shutters with suitablelocking arrangement epoxy powder spray painted with one coat primercomplete including PCC 1:2:4 type B-1 using 20 mm graded stone agregate foundation raised base angle iron size 50mm x50mmx6mm thick 60cm up and 60cm ground level complete all as specified and directed by the Engr in Charge of the following components:- Contractor should arrange factory visit to Engr-in-charge at own arrangementfor LT Pannel manufacturing.(MG Road Qtr) 28 (a) INCOMING :- (i)Supply and fix 4 Pole MCCB ,400 Amp50 Hz 415 V, With Thermal based Release type Capacity 25 KA complete all as specified and directed =02 Nos (incoming) 29 (b) OUTGOING :- (i)Supply and fix 4 PoleMCCB , 100 Amp50 Hz 415 V, With Thermal based Release type Capacity 16 KA complete all as specified and directed =05 Nos 30 (c) Supply and fixR Y B Phase LED based indicator lamp sets comprising of three colours complete all as specified and directed =01 Set 31 (d) Supply and fix Nature switches 415 V three Phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and directed =01 Nos 32 (e).Ammeter 0 - 400 Amps, Digital display, flush mounted 3 phase 4 wire with slector switch including CTs of required capacity =01 Nos 33 (f)Voltmeter 0 - 600 Volts, Digital display, flush mounted3 phase 4 wire with slector switch - 01 Nos 34 Material & Labour for supply,installing,testing & commissioning of factory madeLT panel outdoor typefor LT distribution switch gear and control gear,floor mounted ,cubical type modular compartment, dust and vermin proof with neoprene gasket fabricated out of CRCA sheet of thick ness not less than 3.15 mm (CPRI Approved) complete with bus bar chamber & cupperBus bar of four wire system 415 volt with heat shrinkableinsulator sleeve suitable for 500 A for phases and for neutral having openable front and rear shutters with suitablelocking arrangement epoxy powder spray painted with one coat primercomplete including PCC 1:2:4 type B-1 using 20 mm graded stone agregate foundation raised base angle iron size 50mm x50mmx6mm thick 60cm up and 60cm ground level complete all as specified and directed by the Engr in Charge of the following components:- (Note:- Contractor should arrange factory visit to Engr-in-charge at own arrangementfor LT Pannel manufacturing.)(MG Road Pump House,Patel Road Qtrs) 35 (a) INCOMING :- (i) Supply and fix 4 PoleMCCB , 630 Amp50 Hz 415 V, With Thermal based Release type Capacity 25 KA complete all as specified and directed =02 Nos 36 (b) OUTGOING :- (i) Supply and fix 4 PoleMCCB ,100 Amp50 Hz 415 V, With Thermal based Release type Capacity 16 KA complete all as specified and directed =06 Nos 37 (c) Supply and fixR Y B Phase LED based indicator lamp sets comprising of three colours complete all as specified and directed =01 set 38 (d).Ammeter 0 - 400 Amps, Digital display, flush mounted 3 phase 4 wire with slector switch including CTs of required capacity =01 Set 39 (e)Voltmeter 0 - 600 Volts, Digital display, flush mounted3 phase 4 wire with slector switch - 01 set. 40 (g) Supply and fix time switches 415 V three Phase of 20 Amp rating with contactor fitted inside steel enclosure. 41 Material & Labour for supply,installing,testing & commissioning of factory madeLT panel outdoor typefor LT distribution switch gear and control gear,floor mounted ,cubical type modular compartment, dust and vermin proof with neoprene gasket fabricated out of CRCA sheet of thick ness not less than 3.15 mm (CPRI Approved) complete with bus bar chamber & aluminiumBus bar of four wire system 415 volt with heat shrinkableinsulator sleeve suitable for 315 A for phases and for neutral having openable front and rear shutters with suitablelocking arrangement epoxy powder spray painted with one coat primercomplete including PCC 1:2:4 type B-1 using 20 mm graded stone agregate foundation raised base angle iron size 50mm x50mmx6mm thick 60cm up and 60cm ground level complete all as specified and directed by the Engr in Charge of the following components:- Contractor should arrange factory visit to Engr-in-charge at own arrangementfor LT Pannel manufacturing.(MES Colony & MAP QTR ) 42 (a) INCOMING :- (i) Supply and fix 4 Pole MCCB ,200 Amp50 Hz 415 V, With Thermal based Release type Capacity 25 KA complete all as specified and directed =02 Nos 43 (b) OUTGOING :- (i) Supply and fix 4 PoleMCCB ,63 Amp50 Hz 415 V, With Thermal based Release type Capacity 25 KA complete all as specified and directed =04 Nos 44 (c) Supply and fixR Y B Phase LED based indicator lamp sets comprising of three colours complete all as specified and directed =01 set 45 (d).Ammeter 0 - 400 Amps, Digital display, flush mounted 3 phase 4 wire with slector switch including CTs of required capacity =01 Set 46 (e)Voltmeter 0 - 600 Volts, Digital display, flush mounted3 phase 4 wire with slector switch - 01 set. 47 (g) Supply and fix time switches 415 V three Phase of 20 Amp rating with contactor fitted inside steel enclosure. 48 Material & Labour for supply,installing,testing & commissioning of factory madeLT panel outdoor typefor LT distribution switch gear and control gear,floor mounted ,cubical type modular compartment, dust and vermin proof with neoprene gasket fabricated out of CRCA sheet of thick ness not less than 3.15 mm (CPRI Approved) complete with cupper bus bar chamber & AluminiumBus bar of four wire system 415 volt with heat shrinkableinsulator sleeve suitable for 315 A for phases and for neutral having openable front and rear shutters with suitablelocking arrangement epoxy powder spray painted with one coat primercomplete including PCC 1:2:4 type B-1 using 20 mm graded stone agregate foundation raised base angle iron size 50mm x50mmx6mm thick 60cm up and 60cm ground level complete all as specified and directed by the Engr in Charge of the following components:- Contractor should arrange factory visit to Engr-in-charge at own arrangementfor LT Pannel manufacturing.(patel Road) 49 (a) INCOMING :- (i)Supply and fix 4 Pole MCCB ,200 Amp50 Hz 415 V, With Thermal based Release type Capacity 35 KA complete all as specified and directed =02 Nos 50 (b) OUTGOING :- (i) Supply and fix 4 PoleMCCB ,63 Amp50 Hz 415 V, With Thermal based Release type Capacity 25 KA complete all as specified and directed =05 Nos 51 (c) Supply and fixR Y B Phase LED based indicator lamp sets comprising of three colours complete all as specified and directed =01set 52 (d).Ammeter 0 - 400 Amps, Digital display, flush mounted 3 phase 4 wire with slector switch including CTs of required capacity =01 Set 53 (e)Voltmeter 0 - 600 Volts, Digital display, flush mounted3 phase 4 wire with slector switch - 01 set. 54 (g) Supply and fix time switches 415 V three Phase of 20 Amp rating with contactor fitted inside steel enclosure. 55 Material & Labour for supply,installing,testing & commissioning of factory madeLT panel outdoor typefor LT distribution switch gear and control gear,floor mounted ,cubical type modular compartment, dust and vermin proof with neoprene gasket fabricated out of CRCA sheet of thick ness not less than 3.15 mm (CPRI Approved) complete with cupper bus bar chamber & cupperBus bar of four wire system 415 volt with heat shrinkableinsulator sleeve suitable for 630 A for phases and for neutral having openable front and rear shutters with suitablelocking arrangement epoxy powder spray painted with one coat primercomplete including PCC 1:2:4 type B-1 using 20 mm graded stone agregate foundation raised base angle iron size 50mm x50mmx6mm thick 60cm up and 60cm ground level complete all as specified and directed by the Engr in Charge of the following components:- Contractor should arrange factory visit to Engr-in-charge at own arrangementfor LT Pannel manufacturing.(213 fd wksp & MAP qtr 2) 56 (a) 4 pole change over with handle 250 Amp 50 hz 415 volts Capacity 35 KA 57 (b) INCOMING :- (i)Supply and fix 4 Pole MCCB ,630 Amp50 Hz 415 V, With 250 Amp change over with handle Thermal based Release type Capacity 35 KA complete all as specified and directed =01 Nos 58 (c) OUTGOING :- (i) Supply and fix 4 PoleMCCB ,200 Amp50 Hz 415 V, With Thermal based Release type Capacity 25 KA complete all as specified and directed =05 Nos 59 (d) Supply and fixR Y B Phase LED based indicator lamp sets comprising of three colours complete all as specified and directed =01set 60 (e).Ammeter 0 - 400 Amps, Digital display, flush mounted 3 phase 4 wire with slector switch including CTs of required capacity =01 Set 61 (f)Voltmeter 0 - 600 Volts, Digital display, flush mounted3 phase 4 wire with slector switch - 01 set. 62 (g) Supply and fix time switches 415 V three Phase of 20 Amp rating with contactor fitted inside steel enclosure. 63 Supply and fix testing and commissioning Out door type Bus bar made out of MS CRCA sheet 2mm thick of size 0.60 Mtrx0.60mtrx0.30 mtr consisting of cupper Bus Bar of rating 400 Amps working 4 wire system 415 volt mounted on various insulator with cable earth alleys including steel flexible pipe as per required length at site with new aluminium lugs of suitable size including making connection properly of existing cables of any size/type for existing new incoming and outgoing cables complete all as specified and as directed by Engr-In-Charge. Note :Bus Bar mounting stand made out of angle iron of size 50mm x50mm x 6mm, 600 mm high and size suitable to mount the panel includingfoundation of PCC (1:3:6) type C-1 using 20mm graded stone aggregate with and including excavation and earth work in any type of soil complete.Contractor should arrange factory visit to Engr-in-charge at own arrangementfor LT Pannel manufacturing.