}

Tender For Provision Of Certain Revenue Works (04 Nos) And Minor Work (01 No) At Eme School Vadodara., baroda-Gujarat

Tender Notice

51836014
Tender For Provision Of Certain Revenue Works (04 Nos) And Minor Work (01 No) At Eme School Vadodara.
Tender
Indian
Gujarat
Baroda
05-11-2025

Tender Details

Tender For Provision Of Certain Revenue Works (04 Nos) And Minor Work (01 No) At Eme School Vadodara.; 1 Earth work in excavation by mechanical means (hydraulic excavator) means over areas (exceeding 30 cm in depth upto 1.5 M, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, ( all kinds of soil) complete all as specified and directed by the Engr-in-Charge. 2 Earth work in excavation by mechanical means (hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, (all kinds of soil) complete all as specified and directed by the Engr-in-charge. 3 Site clearence and getting out in soft/loose soil & removal from site all as directed by the Engr-in-Charge. 4 Surface dressing n exc 15 cm deep in soft loose soil including removing the debris as directed by Engr- in- Charge. 5 Surface excavation n. exc 30cm deep & avergeing 15cm deep and getting out in soft/loose soil 6 M&L for anti-termite treatment by treating the backfill in contact with foundation at the rate of 7.5 liters of emulsion per square meter of vertical surface complete all as specified and directed by the Engr-in-Charge. 7 M&L for anti-termite treatment by treating the top surface of filled earth at the rate of 5 litres of emulsion per square meter of surface complete all as specified and directed by the engr-in-charge. 8 M&L for anti-termite treatment by treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed by the Engr-in-Charge. 9 M&L for anti-termite treatment by treating the soil under plinth protection at the rate of 5 liters of emulsion per square metre of surface area complete all as specified and directed by the Engr-in-Charge. 10 M&L PCC (1:4:8) type D2 using 40mm graded stone aggregate in foundation complete all as specified and directed. 11 M&L PCC (1:3:6) type C0 using 12.5mm graded aggregate in door frame filling complete all as specified and directed. 12 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft or loose soil complete all as specified and directed. 13 Removing excavated soil not exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point 14 Use and waste of formwork to sides of concrete foundations, footings, bases of columns, plinth beam and similar work fair finished surface complete all as directed. 15 Use and waste of formwork to sides of pillars, posts, columns etc in square, rectangular and similar work fair finished surface complete all as directed. 16 Use and Waste offormwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished surface complete all as specified and directed by Eng-in-Charge. 17 Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for fair finished surface complete all as specified and directed by Eng-In-Charge 18 M & L RCC (design mix) M-25 ( 20mm graded stone agg) as in foundation, including rafts, plinth beams, footings all as specified and directed by Eng-In-Charge 19 M&L for RCC (design Mix) M-25 (20mm graded stone aggregate) as in Lintels, chajjas & roof beam all as specified and directed by Eng-In-Charge 20 M & L RCC (design mix) M-25 ( 20mm graded stone agg) as columns, pillars, piers, posts and strutsall as specified and directed by Eng-In-Charge 21 M&L for RCC (design Mix) M-25 (20mm graded stone aggregate) as in slabsall as specified and directed by Eng-In-Charge 22 Supply and fix TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all asspecified and directed by Engineer-in-Charge. 23 Supply and fix TMT bars 6 to 8 mm dia, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all asspecified and directed by Engineer-in-Charge. 24 All as per item No 23 herein before but 5mm diaand over upto and including 8mm dia & over as in stirrups, spacers and binders 25 M&L for mild steel bars 20mm dia round bars for rungs in Manhole. 26 M&L Brick work withsub class B Bricks burnt bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge . 27 M & L Brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 28 M& L for Brickwork with fly ash bricks with old size bricks in one brick thick honey-comb walling, built in CM 1:4 complete 29 M & L for rendering in two layer onfair faces of brick work or concrete surfaces of wall 5 mm thick in CM 1:4 mixed with WPCas per manufacturers instructions of cement for finished even and smooth without using extra cement over 10 mm thick rendering incement mortar 1:6 complete all as specified and directed. Note - WPC shall be measured and paid separately as supply only. 30 M&L for 5mm thick rendering in CM 1:3 on brick work or concrete surfaces finished even and smooth w/o using extra cement in Ceiling etc complete all as specified and directed. 31 M & L for rendering 10mm thick on brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified complete all as specified and directed by Eng-In-Charge 32 Supply Only Integral water proofing compound. 33 M&L for preparation of new plastered surfaces of walls andapplying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfacescomplete all as specified and directed by Engineer - in – Charge 34 M&L three coats of white wash all as specified on wall, etc complete all as specified and directed by engr-in-charge. 35 M&L three coats of white wash all as specified on ceilings, etc complete all as specified and directed by engr-in-charge. 36 M&L for two coats Of Oil Bound Distemper over one coat of wall primer over avg 2mm thick wall care putty all as specified with approved color pattern on walls, beams, soffits, columns, etc. complete all as specified complete all as specified and directed by Eng-In-Charge 37 S&F Pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete 38 S&F for 35mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type 1.0mm thick (veneered on both side) with decorative choice laminated type 1 (factory laminated), or surface finish, 6mm thick or external teak wood lipping fixed with nails, color and pattern as approved by EIC/GE. 39 S & F solidPVC door frame of size 50mmx47mm made out of 5mm pre-lam PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing and matching with door shutter shade.The door frame shall be tied to the wall using 75/100mm long MS screw as directed. 40 M &L Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain coloue PVC C channel having a PVC sheets strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail &bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing 41 S & F aluminium alloy, anodized sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolt and sliding bolt of extruded section length of bolt of 250mm 42 S & F aluminium anodized barrel tower bolt of extruded section and fixed of size 150mm complete all as specified and directed by Eng-In-Charge/JE. 43 S & F aluminium anodized barrel tower bolt of extruded section and fixed of size 200mm complete all as specified and directed by Eng-In-Charge/JE. 44 S&F extruded aluminium alloys handles fabricated type anodized of size 150mm long complete all as specified and directed by Eng-In-Charge/JE. 45 S&F extruded aluminium alloys handles cast type anodized of size 125mm long complete all as specified and directed by Eng-In-Charge/JE. 46 S &FMild steel Butt Hinges of 100 mm long medium weight cold rolled & fixed with screws complete all as specifeid and directed by Engr-in-charge 47 M&L for 100 mm butt hinges stainless steel grade 202, 14 gauge thickness medium weight fixed with pressed steel door frame / pvc door frame with screws 48 S&F curtain rails 25mm dia ofmild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed. 49 S&F powder coated aluminium (minimum thickness of powder coating not less than 50 micron) work for frame and shutters of doors, windows, ventilators and partitions (fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per drawings and as approved and directed by Engineer-in-charge. 50 S&F 4.00mm thick sheet glass, selected quality and glazing with rubber beading or with glazing clips, all as specified and directed. 51 Supply and Fixing 4.00mm thick figuredglass, pin head typeand glazing with rubber beading or with glazing clips n exc 0.5, all as specified and directed. 52 S&F mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.gde-E-165 complete all as specified and directed. 53 S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples 54 M & L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including screed bed or bedding layer of mortar 15 mm thick withCM 1:6 complete all as specified and directed. 55 M & L for machine cut Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade including 10mm thick rendering for screed bed on vertical surface of wall or concrete surfaces in CM 1:4 to receive wall tiles. 56 M & L for 16 to 18 mm thick machine cut green marble stone as in floor, steps (in single piece), cooking platform, cills of window etc laid over 15 mm thick cement screed and jointed withbase laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including15mm thick plaster incement mortar 1 : 4 complete all as specified and as directed. 57 M&L Granitework (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specifeid and directed by Engr-in-charge .Note : Shade of granite will be finalised by Engr-in-charge 58 M&L fornon skid coloured ceramictile 7 to 8 mm thick, area of each tileexceeding0.06 sqm but not exceeding 0.11sqm , as in floors etc set over and including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes withCM 1:4. 59 M&L for PCC 75mm thick 1:2:4 Type B2 (40 mm graded stone aggregate) as in sub base complete all as specified and directed. 60 M&L for PCC 75mm thick 1:4:8 Type D2 (40mm graded stone aggregate) as in sub base complete all as specified and directed. 61 M & L for Glazed ceramic coloured walls tilesin vertical surfaces 300x450x 6mm to 7 mm thick set over and including high performence adhisive, tile adhisive or equivalentmixed in cement as per manufacturer instructionand jointed with polymer modified cementetious groutof pigment matching to tile color including 10mm thick rendering for screed bed on vertical surface of wall or concrete surfacesin CM 1:3 to receive wall tiles (Tile pattern and decoration may be as suggested by Engineer-in-charge). 62 M & L PCC 75mm thick as in Plinth protection (1:3:6) using 20mm graded stone aggregate surfaced even and smooth without using extra cement . 63 M&L for hardcore of gauge n exc. 63 mm, of broken stone deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface 64 M&L for hardcore of gauge exc. 63 mm but not exc. 100mm of broken stone deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface 65 M&L for Forming Contraction (Dummy)joints 65mm deep x 10mm wide, filled with sealing compound Grade B 66 M&L for filleting in any position and to any shapeexc. 25 sq.cm but n exc. 50 Sqcm in cement mortar 1:4 including all mitres, stops, etc. 67 M&L for roof treatment comprising of the following:-(a)10 mm thick cement mortar (1:3) with water proofing compound and surfaces finished even and smooth without using extra cement all as specified and Applying evenly a coat of bituminous primer conforming to IS-3384 @ 0.40 ltr per sqm. (b)Second coat of blown type bitumen confirming to IS 702-1988 grade S-35 (30/40) applied @ 1.2 Kg/Sqm. (c) Third layer of 3 mm thick APP modified polymericmembrane with 75 mm sides overlap & end overlap 100 mm. (d) Final coat of binding material using blown type bitumen confirming to IS 702 of grade 85/25 for finishing the overlap joints etc.@ 1.2 Kg/Sqm and the top most layer shall be 40mm thick PCC 1:2:4 type B0 using 10mm graded stone aggregate mixed with WPC, well compacted and making V shaped groove 10mm wide X35 mm deep at a distance of 600 mm both side and filled with mastic bitumen in ratio 1:1(sand : bitumen) complete all as specified. 68 S&F Vitreous China wash down water closet pan (Europion pattern), white (excluding fixing bolts, flushing cistern and flush pipe) squatting pan including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor. complete all as specified and as directed (excluding flushing cistern & flush pipe) complete in all respect all as specified 69 S&F Vitreous China wash down water closet (Squat pattern ) white complete as fixed in repair excluding flushing cisternand flush type Orrisa pattern size 580x440 with integral footrest inject connection to trap antisyphonage etc complete including joint between flushing pipe and socket of WC. 70 S&F PVC flush pipe of 32 mm dia, upto 750mm long complete all as specified and directed. 71 S&F plastic water closer seat White Colour for toilet EWC, closed pattern with flat bottom and cover and mild steel chromium plated oraluminum hanging device complete all as specified and directed. 72 S&F Toilet Paper Holder, mild steel chromium plated as per standard size complete all as specified and directed. 73 S&F Vitreous China Urinal Bowl Type 465x355x265mm white with suitable size of CP grating fixed with wallcomplete all as specified and directed. 74 S&FCP urinal spreaderfixed to urinal with brass chromium plated screws complete all as specified and directed. 75 S&F C I Nahani Traps 75mm Bore complete all as specified and directed. 76 S&F C I Floor Traps 75mm Bore complete all as specified and directed. 77 S & Fvitreous china under counter Wash hand basin, white, size 536x435 mm except taps, CP waste coupling all as specified. 78 S&F CP bottle trap 32mm in repairs brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed,complete all as specified and as directed 79 S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers 80 S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and as directed 81 S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and as directed 82 S&F PVC Bend Suitable For 110 mm bore pipe complete all as specified and directed. 83 S&F PVC Bend Suitable For 75 mm bore pipe complete all as specified and directed. 84 S & F rotational moulded PVC water storage tank 1000ltrs capacity conforming to IS-12701(1989) cylindrical vertical type three-layered white coloured with closed top including inlet,outlet and wash out holes of approved make hoisted and fixed in position all as specified in SSR Part I including S&F 20mm ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 455 gms) including 20mm dia GI pipe for over flow complete all as specified and directed. 85 S & F rotational moulded PVC water storage tank 500ltrs capacity conforming to IS-12701(1989) cylindrical vertical type three-layered white coloured with closed top including inlet,outlet and wash out holes of approved make hoisted and fixed in position all as specified in SSR Part I including S&F 20mm ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 455 gms) including 20mm dia GI pipe for over flow complete all as specified and directed. 86 S & F 15mm dia concealed type stop valves/angle valve, cast copper alloy, ISI marked, screwed down high pressure with crutch of butter fly handle, fancy type , chromium plated, with long shank and cup, screwed both ends for iron pipes or for union,completeall as specified and directed by Eng-In-Charge 87 S & FPillar taps , cast copper alloy, swan neck chromium plated, screwed down high pressure, screwed for pipe of 15mmand fixed completeall as specified and directed by Eng-In-Charge 88 Supply and Fixing PVC connections 15mm size with PTMT nuts of length 450mm etc all as directed and specified. 89 S&F PVC valveless symphonic action type flushing cistern, low level white with inlet ball valve float and handle including brackets, flush pipe. 10 ltr capacity complete all as specified and as directed by engineer in charge. 90 S&F 15 mm Bib taps, cast copper alloy chromium plated with crutch handle, screwed down, screwed for iron pipe complete all as specified and as directed. 91 S&F health faucet mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.(Make: Prayag Model Cat No CPHF-1 or equivallent in Hindware/Jaquar 92 S&F Tube medium grade galvanized, with all fitting and fixed complete to walls and ceiling etc 25mm bore complete all as specified and as directed by engineer in charge.. 93 S&F Tube medium grade galavanised, with all fitting and fixed complete to walls and ceiling etc 20mm bore complete all as specified and as directed by engineer in charge.. 94 S&F 32 mm bore low density polyethylene pipe (LDPE) of pressure rating 6 Kgf/cm2 as in waste pipe 95 S&F 40mm bore UPVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe 96 S&F gun metal gate valve 25mm globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. 97 M& L for Cutting existing steeltubing for alterations oradditions (Each cut measured) and inserting new Tee, bend, elbow etc upto 50mm dia complete & as directed. 98 S & F 110mm PVC (SWR) WC connector with lip ring all as specified and as directed. 99 S & F 110mm PVC (SWR) junction single, (Single T) equal or unequal all as specified and as directed. 100 S & F 75mm PVC (SWR) junction single, (SingletT) equal or unequal all as specified and as directed. 101 S & F75mm PVC (SWR) floor trap, plain with CP grating including jointing with solvent all as specified and as directed. 102 S & F110mm PVC (SWR) gully trap, plain with CP grating including jointing with solvent all as specified and as directed. 103 S & F110mm bore PVC (SWR) branch piece, single (single Y) equal or unequal or with parallel branches with access door all as specified and as directed 104 S & F 75mm bore PVC (SWR) branch piece, single (single Y) equal or unequal or with parallel branches with access door all as specified and as directed 105 S & F stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays incliding bolts and nuts and securing ends of stays to walls and roofs for 110mm bore pipe all as specified and as directed 106 S & F stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays incliding bolts and nuts and securing ends of stays to walls and roofs for 75mm bore pipe all as specified and as directed 107 S & F 110mm PVC (SWR) vent cowl all as specified and as directed 108 S & F 75mm PVC (SWR) vent cowl all as specified and as directed 109 Removing excavated material exc. 250m but n exc 500m and depositing where directed at a level n.exc. 1.5 m above the starting point. 110 Removing excavated material exc. 500m but n exc 1.5KM and depositing where directed at a level n.exc. 1.5 m above the starting point. 111 M&L PCC 1:3:6 type C2 using 40mm graded stone aggregate as75mm thick finished fair all as speificed and directed 112 Supplyand laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;specified and directed.(Note:-Manufacture test certificate of paver block shall be submitted to depat M-35 grade by the contractor) 113 M&L for factory made precast machine pressed kerb stones of PCC grade M-15 design mix and of shape and size rected, set jointed and pointed cement and sand mortar 1:4 fixed in repairs with and including necessary excavation and earthwork and making good the disturbed surfacesto match with the existing surfaces including removal of dispodal of rubbish complete all as specified and directed. Sizes shall be as under :- Length (L) not less than 300mm, Height (H) 300mm to 350mm, Thickness (T) 100mm and radius (R) 75mm including painting on kerb stone of synthetic enamel paint yellow or white colour complete all as specified and directed. 114 Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10sq.m on plan and not exceeding 1.5m in depth and getting outin soft/loose soil. 115 Excavating in trenches, exceeding 1.5m wide and not exceeding 3.m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10sq.m on plan and not exceeding 1.5m in depth and getting outin soft/loose soil. 116 M & L Plain cement concrete (1:3:6), type C-2, using 40 mm graded stone aggregates as in concrete bed to drain pipes laid to falls in trenches in any depth including packing under and haunching against the sides of pipes with concreteafter the pipes are laid and tested complete, all as specified 160 mm bore pipes 117 M&L concrete bed of 1:4:8 type D-2 (usinng 40mm graded stone aggregate) for 150mm bore pipe, including packing under and haunching against the sides of pipes after they are laid and tested. 118 M&L for UPVC (SWR) 160mm dia pipes for sewage line layingcomplete all as specified and directed. 119 M & L 200 mm Bore of pipe Reinforced con-crete pipes, class NP 2 with one collar per length of pipe laid in trenches at any depth including jointing and testing complete, all as specified. 120 M&L PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping etc., including weathering, slightly rounded or chamfered and throating with necessary form works complete all as specified and directed 121 M&L PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in surface channel, drains, benching and finishing the surface even and smooth using extra cement including necessry use and waste of formwork complete all as specified and directed 122 M & L Providing precast cement cocrete cover slabs for manholes etc. and similar articles with plain faces type B1 1:2:4 (20 mm graded stone aggregate). (Note:- Reinforcement shall be measured and paid separately.) 123 M&L for Providing precastcement concretelouvres and jallies,40mm thick(measuredsolid),Type BO 1:2:4 using 12.5mm graded stone aggregate (measured solid) set in CM 1:4 including allmould- ings Complete fixed in position. 124 M&L Rendering 10 mm thick on fair faces of brick work or concrete surfaceswith Cement plaster(1:4) and mixed with WPC etc complete all as specified and directed. (WPC shall be measured and paid separately) 125 Cutting into existing manhole for connecting new drain of 150 mm bore pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished, reforming benching as required, complete all as specified. 126 Rendering 15 mm thick onfair faces of brick work or concrete surfaces of wall in cement mortar 1:4 for finished even and smooth (without using extra cement) 127 M& L for Loose filling with broken bricks aggregates of gauge 80 to 150 mm in soakage pits, soakage wells Complete. 128 M & Lfor preparingnew plastered surfaces of wall and applying twocoats cement base paint over a coat of alkali resistant primer on external wall. 129 M&L for concealed point wiring with 1.5 Sqmm PVC-FRLS insulated, sheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit,includingmodular metal flush boxes with modular white cover plate and frame as per site requirement all fittings such as tees, bends, elbows,etc. of External diameter 20mmall as per site requirements PVC insulated & sheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete incl cutting and chasing in stone/brick masonry and making good disturbed surface all as specified and directed by Engr-in-charge for the following:- 130 For one light, fanpoint controlled by one switch 131 For one5 Amp independent socket point controlled by one switch 132 For one 3 pin ,5 Amp socket point with other switch on the same board 133 All as per item No 130 here in before but for power point wiring usingwith 2.5sqmm PVC-FR LS insulated ,sheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,sheathed, copper conductor stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed by engir in charge. 134 S&F Modular switch, one way, 6 Amp 230, 1 module 135 S&F socket Modular 6 Amp-2/3 pin combined 2 module 136 S&F switch Modular, single pole, one way,16 Amp ,1 module 230 Volt 137 S&F socket modular 6/16 Amp, 2/3 pin combined ,2 module 230 Volt . 138 S&F ceiling rose, surface backlit,three terminal. 139 S&F modular lamp holder, PVC/ Polycarbonate type with back plate for batten angle fitting including 9 watt LED lamp retrofit complete all as specified and directed 140 S&F modular fan step regulator 120W, 2 module. 141 Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 142 Supply and fixing LED lights fitting 1x 10W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 143 Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete 144 S&F LED light fitting 1x9W/1X10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. 145 S&Ftesting and commissioning of MCB SP 6 Amp to 32 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs. 146 S&F testing and commissioning of MCB SPN 240 volt 40 Amp10 KA capacity having C-curve characteristics connected with suitable lugs including taking down. 147 S&F sheet metal enclosure for DB double door, IP-43 when MCBs to be used SPN, 8 way, 240 V with 200 Amps rated bus bar 148 S&F sheet metal enclosure for DB double door, IP-43 when MCBs to be used SPN, 6 way, 240 V with 200 Amps rated bus bar 149 S & F of ceiling fan whitecomplete with blades, down rod from existing roof / trus to fall ceiling, and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor including ceiling fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rosecomplete all as specified and directed. 150 Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. 151 Supply & fix exhaust fans AC single phase 230/ 240 V of size 300 mm sweep mettalic body with all accessories including making hole in stone /brick wall grouting & making good in all aspects including electric connectionall as specified and directed. 152 Supply & fix of exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50Hz, RPM 1200, copper winding of sweep 300mm including exhaust fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose 153 M&L for concealed Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 6.0 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 6.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor.NOTE : Two runs of single core 6.0 sqmm and one run of 6.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length. 154 M&L for provn of Earthing complete with galvanised steel earth plateelectrode, 600x600x6mm buried directly in ground (Earth pit not less than 2.25M deep below the GL) with top edge not less than 1.5 metres below ground level connected with galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steelall as shown in electric plate no 3 connected to earthing test point all as specified or indicated including testing on completion.Note :- (i) The rate quoted shall also deemed to include the cost of GI wire and protection pipe upto 7.5 Mtr beyond the earth plates electrode and also the costof the Test point. (ii) Joining of GI earth wire with pipe of the test point shall be done by using suitable cable lugs. (Rate shall be deemed to include GI water pipe & protection pipe both of suitable lenght) 155 Supply and lay pipe galvanised Medium grade including fittings, 25 mm bore (1) dia laid in trenches. 156 Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100Volts grade with stranded aluminium conductor of 10 Sqmm 2 core size 157 Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100Volts grade with stranded aluminium conductor of 6 Sqmm 2 core size 158 Supply and laying dry sand cushioning to UG cable 8 cm thick before laying and 15cm thick after laying complete all as specified and directed.Note:-1.Dry fine sand of best available quality shall be used.2. Punned thickness shall be made and paid. 159 M & L well burnt bricks sub class B as in protection of cable laid dry, flat abutting each other width wise all as directed 160 M & L for galvanized steel tubing light Grade of 25 mm dia protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.

Key Value

Document Fees
INR 500 /-
Tender Value
INR 39.09 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail