Tender For Re-Electrification Of Rooms In Various Buildings At Fact Uc; 1 Re-electrification of rooms in various buildings at FACT UC 2 PVC conduit point wiring over/through beam/wall / column / ceiling /cable trayswith individual control for light / fan/ bell/ 6A modular plug sockets separatelymounted , using FRLS flexible copper wires of 1.5 sq.mm for phase, neutral and earth connection through PVC conduit of minimum size of 20mm with ISI marking, as per relevant drawings or instructions from FACT engineer. Scope of work include preparation and fixing of PVC conduits,modular switch boards, switches, cover plates,dummy plates etc, fixing ceiling roses on suitable junction boxes, modular step type regulators for fans(as required),drawingflexible copper wires of 1.5 sq.mm, connecting, testing and commissioning. The PVC conduit fixing shall either be open or concealed. The cutting of wall and replastering for concealed conduit fixing is mentioned as separate schedule of work. All the switch boards must be fixed concealed, unless asked to fix on surface. If required, holes through wall need to be made for conduit passing. For a point wiring,pipe length of 10 metres shall be considered as one point and pipe length above 10m and less than 20m shall be considered as one and half points and if additional power sockets are provided in same Switch Boards that shall be considered as half point. Sockets shall be shutter type. All the materials required for wiring such as copper flexible wires, PVC conduits, metallic modular switch boards, modular switches, cover plate, dummy plates, PVC box for fixing ceiling rose, PVC Junction boxes(2/3/4 way) etc. shall be inthe scope of contractor. Ivory color PVC conduit shall be used for open conduit wiring. If any wiring need to be concealed that portion may be executed with black/ivory color PVC conduits. Suitable lengths of PVC flexible hose shall be used for point wiring above false ceiling as per the requirement. 3 PVC conduit Point wiring over/through beam/wall / column / ceiling with individual control for 16 A modular plug sockets with SP switch. Individual plug socket with switch. Wiring shall be using 2.5 sq.mm FRLS multi strand flexible copper wire for phase, neutral and earth connections, through PVC conduits of minimum size 20 mm with ISI mark. The work shall include preparation and fixing of PVC conduits, wiring along wall and drawing wires as required,preparation and fixing of modular switch boards, switches, plug sockets, cover plates, dummyplates, suitable junction boxes etc., wire termination, testing and commissioning.Sockets shall be 6/16A type. The PVC conduit fixing shall either be open or concealed. The cutting of wall and replastering for concealing conduit fixing is mentioned as separate schedule of work. All the switch boards must be fixed concealed, unless asked to fix on surface. If required, holes through wall need to be made for conduit passing. Ivory color PVC conduit shall be used for open conduits. If any wiring need to be concealed that portion may be executed with black/ivory color PVC conduits. For a point wiring, 10 metres shall be considered as one point and Pipe length above 10m shall be considered as one and half points.. 4 PVC conduit point wiring from DB to switch board or between switchboard to switch board looping along/through beam/wall / column / ceiling/cable trays using 2.5 sq. mm FRLS flexible copper wires for phase, neutral and earth through PVC conduit of minimum size 20mm with ISI marking, as per relevant drawings or instruction from FACT engineer.Scope of work include preparation and fixing of suitable junction boxes if required, drawing flexible copper wires of 2.5 sq.mm, connecting, testing and commissioning are under the scope of contractor.The work shall include preparation and fixing of PVC conduits, drawing wires as required, fixing suitable junction boxes etc., wire termination, testing and commissioning. The PVC conduit fixing shall either be open or concealed. The cutting of wall and replastering for conduit concealing is mentioned as separate schedule of work.If required, holes through wall need to be made for conduit passing. Ivory color PVC conduit shall be used for open conduits. If any wiring need to be concealed that portion may be executed with black/ivory color PVC conduits. For a point wiring, 10 metres shall be considered as one point and pipe length greater than 10 metres shall be considered as one and a half point, upto 20m. All the materials required for wiring such as copper flexible wires, PVC junction boxes(2/3/4 way),etc. shall be in the scope of the contractor. 5 Cutting into walls for executing concealed PVC conduit wiring and replastering after the work. All the tools & materials for this work shall be under the scope of the contractor 6 Supply, fixing and servicing of 20W LED batten type tube light fittings surface mounted with required clamps/ fasteners. 7 Supply, fixing and servicing of industrial wall mounting fans of 450 mm sweep, 230V on walls/beams. All the required fasteners/ accessories are under the scope of contractor. 8 Supply of industrial wall mounting fans of 450 mm sweep, same item as mentioned in schedule 7 9 Supply of exhaust fan 450mm sweep with all the accessories and fasteners. 10 Supply, fixing and servicing of flood light 45± 5W, ≥100 lm/watt. All the required fasteners/ acessories are under the scope of contractor. 11 Supply, installation and servicing of 1200mmremote operated BLDC ceiling fan with suitable clamps/fasteners. Supply of all materials required for the work shall be under the scope of the contractor. The service value of wall fan shall be higher Than 5.5 CMM/Watts.(Refer BEE Guide lines for service value and Star Ratings) 12 Supply of 3 modular switch board box with frame and plate 13 Supply of 6 modular switch board box with frame and plate 14 Supply of 8 modular switch board box with frame and plate 15 Supply of 5/6 Amps modular switch 16 Supply of 16 Amps modular switch 17 Supply of 5 Amps modular socket 18 Supply of 6/16 Amps modular socket 19 Supply of 1 modular blanking plates/dummy 20 Supply of 2 modular electronic fan regulator 21 Open/Concealed fixing of 3 module switch board box to wall with frame, plate, switches/sockets and their connection to existing wiring. All the required fasteners/ accessories are under the scope of contractor. 22 Open/Concealed fixing of modular 6 mod/8 mod switch board box to wall with frame, plate, switches/sockets and their connection to existing wiring. All the required fasteners/ accessories are under the scope of contractor. 23 Supply, fixing and internal terminations of single/double door 8 way, TPN , 415 Volts MCB DB having the following specification:1)63A 4P isolator - 1 No. 2) 63A 4P RCCB with sensitivity of 30mA -1 No 3) 32A single pole B type MCB - 12 Nos4) 25A single pole C type MCB - 4 Nos4) 40A 4P ,C type MCB - 2 NosDB has to be surface mounted on to the wall. 24 Supply, fixing and internal terminations of single/double door 6 way, TPN , 415 Volts MCB DB having the following specification:1) 63A 4P isolator - 1 No. 2) 63A 4P RCCB with sensitivity of 30mA -1 No 3) 25A double pole C type MCB - 4 Nos4) 32A single pole B type MCB - 4 NosDB has to be surface mounted on to the wall.Remaining module spaces has to be covered by blanking plates. 25 Supply, fixing and internal terminations of single/double door 12 way, TPN , 415 Volts MCB DBhaving the following specification:1) 63A 4P isolator - 1 No. 2) 63A 4P RCCB with sensitivity of 30mA -1 No 3) 16A single pole B type MCB - 24 Nos4) 32A double pole C type MCB - 6 NosDB has to be surface mounted on to the wall. 26 Supply of decorative garden light for outdoor purpose preferrably of make Luker, model LOBOV60-12W 27 Supply ,fixing and servicing of 32 Amps TPN Distribution Board with Three Pin Metal Clad Industrial Plug and Socket (Fitted with 32A TPN MCB) 28 Supply of 32 Amps TPN Distribution Board with Three Pin Metal Clad Industrial Plug and Socket (Fitted with 32A TPN MCB) 29 Supply of 3CX2.5 sq.mm flexible copper cable. 30 Supply of 4CX10 sq.mm XLPE Aluminium armoured cable. 31 Supply of aluminium strip 20mm wide, min 1mm thickness for the purpose of clamping cables 32 Supply of aluminium strip 25mm wide, min 1mm thickness for the purpose of clamping cables 33 Supply of 11kV rated Heat Shrinking type Cable straight Joint kit suitable for 3x300 sq.mm XLPE,armoured,Aluminium underground cable . (Acceptable makes :Raychem/3M) 34 Supply of 11kV rated Heat Shrinking type Cable straight Joint kit suitable for 3x400 sq.mm XLPE,armoured,Aluminium underground cable (Acceptable makes :Raychem/3M) 35 Staright jointing/end termination work of HT cables of sizes3x300 sq.mm/ 3x400 sq.mm . The straight joint/end termination kit will be supplied by FACT. The contractor has to arrange the technician with valid cable jointing license for executing the work. 36 Skilled manpower for carrying out replacement of light fittings like street lights/flood lights, new load centre erection, cable connection & termination etc . 37 Unskilled assistance in replacement of light fittings like street lights/flood lights, new load centre erection , cablelaying/connection & termination etc.,