|
| 1 | Taking down carefully (dismantling) ceiling fan of any sweep and size and dismantling blades, opening up for inspection, making joint list of defects and worn out parts to be replaced, jointly by Engineer-in-Charge and contractor, transporting to work shop if required for repairs, re-assembling after repairs including replacement of spare parts and transportation back to store yard for inspection including hanging, fixing and connecting up and testing etc, complete all as specified and directed. Note: 1. Spare parts shallbe measured and paid separately as \"Supply only\".2. Ceiling fans under repair shall be issued through gate pass.3. The contractor must be able to repair minimum 100 fans within a week and deposit the same duly painted complete satisfaction of Engr-In- Charge. Failure to this will impose a penalty of Rs/-100 per fan per day to the contractor.4. After intimation given to the contractor, if the contractor fails to collect the fan for repair within 48 hrs, a penalty of Rs/- 500 per day will be applicable to contractor . 5. The contrator must employ dedicatd manpower for repair ofceiling fan and attending complaints wrt same. 6.Minor spare parts such as PVC wire upto 1 m length, grease, tape etc. shall deemed to be included in quoted rate.7.The quoted rate are deemed to be included for all above provisions. |
| 2 | Supply only ball bearing of existing size suitable for ceiling fan 1200 / 1400 mm sweep of different makes including necessary greasing, complete all as specified and directed. |
| 3 | Supply only gun metal bush of existing size suitable for ceiling fan 1200mm/1400mm, complete all as specified and directed. |
| 4 | Supply only capacitor 2.5/2.75 MFD, complete all as specified and directed. |
| 5 | Supply only capacitorcapacity 3.15 MFD, complete all as specified and directed. |
| 6 | Supply only celing fan down rod 15 mm bore, 300 mm long, factory made, colour brown/ white, complete all as specified and directed. |
| 7 | Supply only celing fan down rod 15 mm bore, 400 mm long, factory made, colour brown/ white, complete all as specified and directed. |
| 8 | Supply only alluminium blade of 1200 mm sweep of ceiling fan (white), complete all as specified and directed. |
| 9 | Material and labour for Painting one coat of synthetic enamel paint (white/ brown/ Black) by spraying to steel surfaces of ceiling fan 1200mm /1400mmincluding blades complete after preparation of surfaces including filling cavities with filler, cleaning dust and dirt etc and writing the MES number/ SM Numberswith black paint on fans, complete all as specified and directed. |
| 10 | Supply only \"U\" clamp with rubber real insulator with nut bolts of size 10mm dia & 75mm long including necessary washers & split pin, complete all as specified and directed. |
| 11 | Supply only upper and lower canopy of plastic with steel screw suitable for fan 1200/1400mm sweep, complete all as specified and directed. |
| 12 | M&L in replacement of flexible cord copper conductor of size 0.75 Sqmm, twin core, flat cable for connection to fans from ceiling roses, complete all as specified and directed. |
| 13 | M&L for opening dismantling of ceiling fans any make/model of size 1200 mmsweep cutting and taking out old burnt / damaged winding / material by any means and re-winding the same with super enamelled copper wire of existing/same SWG including all insulating material all as required as per standard practice, varnishing the same and drying, cleaning fan recommended quality grease /oil, re-assembling and testing complete all as specified and as directed. |
| 14 | M&L for opening dismantling of ceilig fans any make/model of size 1400 mmsweep cutting and taking out old burnt/damaged winding /material by any means and re-winding the same with super enamelled copper wire of existing/same SWG including all insulating material all as required as per standard practice, varnishing the same and drying, cleaning fan recommended quality grease/oil, re-assembling and testing, complete all as specified and as directed. |
| 15 | M&L for opening dismantling of BLDC ceilig fans any make/model of size 1200 mm sweep and taking out old unserviceable electronic PCB refixing the same by taking requisite repairs and making serviceable, complete all as specified and as directed. |
| 16 | M&L for opening dismantling of BLDC ceilig fans any make/model of size 1400 mm sweep and taking out old unserviceable electronic PCB refixing the same by taking requisite repairs and making serviceable, complete all as specified and as directed. |
| 17 | S&F in replacement of electronic step type fan regulator, 250V flush type on the exiting phenolic laminated sheet, complete all as specified and as directed. |
| 18 | Taking down carefully (dismantling) exhaust fan of any sweep and size dismantling blades, opening up for inspection, making joint inventories of defects and worn out parts to be replaced, jointly by Engineer-in-Charge and contractor, transporting to work shop if required for repairs, reassembling after repairs and replacement of spares, ceiling cable ends and transportation back to store yard for inspection including, fixing and connecting up and testing etc complete all as directed.Note: 1. Spare parts shallbe measured and paid separately as \"Supply only\".2. Exhaust fans under repair shall be issued through gate pass.3. The contractor must be able to repair minimum 100 fans within a week and deposit the same duly painted with complete satisfaction of Engr-In- Charge. Failure to this will impose a penalty of Rs/-100 per fan per day to the contractor.4. After intimation given to the contractor, if the contractor fails to collect the fan for repair within 48 hrs, a penalty of Rs/- 500 per day will be applicable to contractor . 5. The contrator must employ dedicatd manpower for repair ofexhaust fan and attending complaints wrt same. 6.Minor spare parts such as PVC wire upto 1 m length, grease, tape etc. shall deemed to be included in quoted rate.7.The quoted rate are deemed to be included for all above provisions. |
| 19 | M&L for rewinding motor of exhaust fan 450 mm sweep with super enamelled copper wire of existing specification, gauge and weight including insulating material, complete all as specified and directed. |
| 20 | All as per Srl item No. 19.00 above but of exhaust fan 380 mm sweep. |
| 21 | All as per Srl item No. 19.00 above but of exhaust fan 300 mm sweep. |
| 22 | All as per Srl item No. 19.00 above but of exhaust fan 250 / 230 mm sweep. |
| 23 | Supply only capacitorcapacity 4.00 MFD, complete all as specified and directed. |
| 24 | Supply only ball bearing as per existing size suitable for exhaust fan 380/450mm sweep including necessary greasing, complete all as specified and directed. |
| 25 | Supply only ball bearing as per existing size suitable for exhaust fan 200 to 350mm sweep including necessary greasing, complete all as specified and directed. |
| 26 | Supply only exhaust fan blade of up to 450 mm sweep, complete all as specified and directed. |
| 27 | Supply and replacement of MS sheet 1.00 mm thick, louver shutter for exhaust fan suitable size for up to 450 mm sweep with all accessories, fixing on wall, complete all as specified and directed. |
| 28 | Supply only electrical motor suitable for exhaust fan up to 250 mm sweep, complete all as specified and directed. |
| 29 | Supply only electrical motor suitable for exhaust fan up to 300 mm sweep, complete all as specified and directed. |
| 30 | Supply only electrical motor suitable for exhaust fan up to 450 mm sweep, complete all as specified and directed. |
| 31 | Supply only MS mounting legs with rubber bush suitable for any type of exhaust fan up to 450 mm sweep, complete all as specified and directed. |
| 32 | Taking down carefully (dismantling) Air circulator / Pedestal fan of any sweep and size, dismantling blades, opening up for inspection, making joint inventories of defects and worn out parts to be replaced jointly by Engineer-in-Charge and contractor, transporting to work shop if required for repair, reassembling after repairs and replacement of spares sealing cable ends and transportation back to store yard for inspection including fixing and connecting up and testing etc, complete all as specified and directed.Note: 1. Spare parts shallbe measured and paid separately as \"Supply only\".2. Air Circulator / pedalstal fans under repair shall be issued through gate pass.3. The contractor must be able to repair minimum 100 fans within a week and deposit the same duly painted complete satisfaction of Engr-In- Charge. Failure to this will impose a penalty of Rs/-100 per fan per day to the contractor.4. After intimation given to the contractor, if the contractor fails to collect the fan for repair within 48 hrs, a penalty of Rs/- 500 per day will be applicable to contractor . 5. The contrator must employ dedicatd manpower for repair of geyser, ceiling fan, exhaust fan, air circulator fan, wall mounted fan and attending complaints wrt same. 6.Minor spare parts such as PVC wire upto 1 m length, grease, tape etc. shall deemed to be included in quoted rate.7.The quoted rate are deemed to be included for all above provisions. |
| 33 | M&L for rewinding motor of Air Circulator up to 450 mm sweep with super enameled copper wire of existing specification, gauge and weight including insulating material, complete all as specified and directed. |
| 34 | M&L for rewinding motor of Air Circulator 500 to 600 mm sweep with super enameled copper wire of existing specification, gauge and weight including insulating material, complete all as specified and directed. |
| 35 | Supply only ball bearing of existing size suitable for Air circulator fan up to 450 mm sweep including necessary greasing, complete all as specified and directed. |
| 36 | Supply only ball bearing of existing size suitable for Air circulator fan 500 to 600 mm sweep including necessary greasing, complete all as specified and directed. |
| 37 | Supply only gun metal bush of existing size suitable for Air circulator, complete all as specified and directed. |
| 38 | Supply only Plug top 6 Amps, 3 pin, complete all as specified and directed. |
| 39 | Disconnecting electric/water supply connections, dismantling (taking out/down) geyser (storage type water heaters) vertical or horizontal type, 25 to 35 Litres capacity, any make, any model opening up to detect faults, defective and unserviceable parts / spares / instruments / equipments etc, making joint inventories by both Engr-in-charge and Contractor and transporting to workshop if required for repairs, reassembling after repairs, replacement of spare parts and overhauling, descaling, transporting back to site for inspection and installing and fixing in its original position including painting with spray gun one coat of Duco paint, writing MES No./Machine No, filling glass wool, commissioning, testing and brazing to entire satisfaction of Engr-in-charge, complete all as specified and directed.Notes:(a) Spare parts shall be measured and paid separately as \"Supply only\".These shall be identical to those specified by original manufacturer.(b)Items indicated as \"Supply and fixing in replacement\" are out side the scope of this item. (c) Unit rates quoted by tenderers shall deemed to be included for nuts, bolts, washers, lugs, thimbles, wires and petty items/ works required for efficient and smooth functioning of the equipment without any extra cost.(d) The quoted rate are deemed to be included for all above provisions. |
| 40 | All as per srl item No. 35.00 above but 50 Litres capacity. |
| 41 | Supply only heating element including rubber washers for 1500 Watt capacity, 240V suitable type, complete all as specified and directed. |
| 42 | Supply only heating element including rubber washers for 2000 Watt capacity, 240V suitable type, complete all as specified and directed. |
| 43 | Supply only PVC connection 15mm dia with brass nut couplings at both ends, of length 450mm for hot water supply, complete all as specified and directed. |
| 44 | Supply only thermostat fitting/ fitment for geysers of capacity 25 to 50 Litres, complete all as specified and directed. |
| 45 | Supply only safety plug made out of brass for geyser of capacity 25 to 50 Litres, complete all as specified and directed. |
| 46 | Supply only indicator lamps (square/ round) both red and green suitable for geysers of any capacity, complete all as specified and directed. |
| 47 | Supply only Mild steel Bottom cover of geysers in two halves, complete all as specified and directed. |
| 48 | M&L in replacement of PVC flexible copper coductor cable of size 2.5 sqmm, 3 core as connections from MCB / socket to geysers, complete all as specified and directed. |
| 49 | Supply only Inner stainless steel tank of wall thickness 20 gauge and suitable for geyser of capacity 25 litres, complete all as specified and directed. |
| 50 | Supply only Inner stainless steel tank of wall thickness 20 gauge and suitable for geyser of capacity 50 litres, complete all as specified and directed. |
| 51 | Supply and fixing in replacement 15 mm bore dia non return valve of gun metal for geysers as in replacement complete all as specified. |
| 52 | Supply only 15mm dia GI nipple hexagonal 15mm long, complete all as specified and directed. |
| 53 | Supply only Geyser assembly made of copper suitable for geyser of 25/35 Litres capacity, complete all as specified and directed. |
| 54 | Supply only Geyser assembly made of copper suitable for geyser of 50 Litres capacity, complete all as specified and directed. |
| 55 | Supply only Glass wool for geysers of 25 to 50 Litres capacity, complete all as specified and directed. |
| 56 | Supply only Plug top 15 Amps, 3 pin, complete all as specified and directed. |
| 57 | Taking down carefully (dismantling) wall mountingfan of any sweep and size, dismantling blades, opening up for inspection, making joint inventories of defects and worn out parts to be replaced jointly by Engineer-in-Charge and contractor transporting to work shop if required for repair, reassembling after repairs and replacement of spares sealing cable ends and transportation back to store yard for inspection including fixing and connecting up and testing etc, complete all as specified and directed.Note: 1. Necessary repair shall be measured & paid separately. Spare parts shall also be measured and paid separately as \"Supply only\".2. Wall mounting fans are under repair shall be issued through gate pass.Note:1. The contractor must be able to repair minimum 100 fans within a week and deposit the same duly painted complete satisfy of Engr-In- Charge. Failure to this will impose a penalty of Rs/-100 per fan per day to the contractor.2. After intimation given to the contractor, if the contractor fails to collect the fan for repair within 48 hrs, a penalty of Rs/- 500 per day will be applicable to contractor . 3. The contrator must employ dedicated manpower for repair of wall mounted fan and attending complaints wrt same. The cost for the same will be deemed to included in quoted rate. |
| 58 | M&L for rewinding motor of wall mounting fanup to 300 mm sweep with super enameled copper wire of existing specification, gauge and weight including insulating material, complete all as specified and directed. |
| 59 | Supply only ball bearing of existing size suitable for wall mounting fan 300 mm sweep including necessary greasing, complete all as specified and directed. |
| 60 | Supply only electrical motor suitable for wall mounting fan of size 350 to 450 mm sweep, complete all as specified and directed. |
| 61 | Supply only gun metal bush of existing size suitable for wall mounting fan300 mm, complete all as specified and directed. |
| 62 | Supply and fixing ofelectronic PCBBLDC ceilig fans any make/model of size 1200/1400 mmsweep by takingout old one and refixingthe same complete all as specified and as directed. |