|
| 1 | NOTE (Applicable for all items):- The bidders/contractorsare advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE \"A\" |
| 2 | Design, Supply, testing and commissioing ofinverter type 5 KW at P-48 BDE HQ Talbehat Mil station (545Watts) Solar PV Module Mono type, 5 KVA inverter type, mounting, structures alongwith connected accessories . The total solar PV array capacity should not be less than 5 KWp and should comprise of Monocrystalline minimum 200 Wp and above wattage, Module capacity minimium 200 watts. The module type must be qualified as per IEC 61215/IS 14286 latest edition for Crystalline silicon PV module. SPV module conversion efficiency should be equal to or greater than 13-14% under STC.Modules must qualify to IEC 61730 part I and II for safety qualification testing, certificate for module qualification from IEC or equivalent to be submitted as part of the bid offer,undertaking from manufacturer/supplier that the modules being supplied are as per above specification/details.The PV module shall perform satisfactorily in humidity upto 100% with temperature between -40 degree C to +85 degree C.The module would be used in a high voltage circuit, the high voltage insulation test shallbe carried out on each module anda test certificate to that effect provided. |
| 3 | Design, Supply, testing and commissioing ofinverter type 5 KW at P-01 Talbehat Mil station (545Watts)Solar PV Module Mono type, 5 KVA inverter type, mounting, structures alongwith connected accessories . The total solar PV array capacity should not be less than 5 KWp and should comprise of Monocrystalline minimum 200 Wp and above wattage, Module capacity minimium 200 watts. The module type must be qualified as per IEC 61215/IS 14286 latest edition for Crystalline silicon PV module. SPV module conversion efficiency should be equal to or greater than 13-14% under STC.Modules must qualify to IEC 61730 part I and II for safety qualification testing, certificate for module qualification from IEC or equivalent to be submitted as part of the bid offer,undertaking from manufacturer/supplier that the modules being supplied are as per above specification/details.The PV module shall perform satisfactorily in humidity upto 100% with temperature between -40 degree C to +85 degree C.The module would be used in a high voltage circuit, the high voltage insulation test shallbe carried out on each module anda test certificate to that effect provided. |
| 4 | Design, Supply, testing and commissioing ofinverter type 5 KW at Building No. P-23 COOK HOUSE Talbehat Mil station (545Watts) Solar PV Module Mono type, 5 KVA inverter type, mounting, structures alongwith connected accessories . The total solar PV array capacity should not be less than 5 KWp and should comprise of Monocrystalline minimum 200 Wp and above wattage, Module capacity minimium 200 watts. The module type must be qualified as per IEC 61215/IS 14286 latest edition for Crystalline silicon PV module. SPV module conversion efficiency should be equal to or greater than 13-14% under STC.Modules must qualify to IEC 61730 part I and II for safety qualification testing, certificate for module qualification from IEC or equivalent to be submitted as part of the bid offer,undertaking from manufacturer/supplier that the modules being supplied are as per above specification/details.The PV module shall perform satisfactorily in humidity upto 100% with temperature between -40 degree C to +85 degree C.The module would be used in a high voltage circuit, the high voltage insulation test shallbe carried out on each module anda test certificate to that effect provided. |
| 5 | Design, Supply, testing and commissioing of inverter type 5 KW at Building No. P-25 JCO MESS Talbehat Mil station (545Watts) UTL Solar PV Module Mono type, 5 KVA inverter type, mounting, structures alongwith connected accessories . The total solar PV array capacity should not be less than 5 KWp and should comprise of Monocrystalline minimum 200 Wp and above wattage, Module capacity minimium 200 watts. The module type must be qualified as per IEC 61215/IS 14286 latest edition for Crystalline silicon PV module. SPV module conversion efficiency should be equal to or greater than 13-14% under STC.Modules must qualify to IEC 61730 part I and II for safety qualification testing, certificate for module qualification from IEC or equivalent to be submitted as part of the bid offer,undertaking from manufacturer/supplier that the modules being supplied are as per above specification/details.The PV module shall perform satisfactorily in humidity upto 100% with temperature between -40 degree C to +85 degree C.The module would be used in a high voltage circuit, the high voltage insulation test shallbe carried out on each module anda test certificate to that effect provided. |
| 6 | Design, Supply, testing and commissioing ofinverter type 5 KW at Building No. P-6 OFFICER MESSTalbehat Mil station (545Watts) Solar PV Module Mono type, 5 KVA inverter type, mounting, structures alongwith connected accessories . The total solar PV array capacity should not be less than 5 KWp and should comprise of Monocrystalline minimum 200 Wp and above wattage, Module capacity minimium 200 watts. The module type must be qualified as per IEC 61215/IS 14286 latest edition for Crystalline silicon PV module. SPV module conversion efficiency should be equal to or greater than 13-14% under STC.Modules must qualify to IEC 61730 part I and II for safety qualification testing, certificate for module qualification from IEC or equivalent to be submitted as part of the bid offer,undertaking from manufacturer/supplier that the modules being supplied are as per above specification/details.The PV module shall perform satisfactorily in humidity upto 100% with temperature between -40 degree C to +85 degree C.The module would be used in a high voltage circuit, the high voltage insulation test shallbe carried out on each module anda test certificate to that effect provided. |
| 7 | Design, Supply, testing and commissioing of inverter type 5 KW at BUILDING NO. P-6 ADM BLOCK Talbehat Mil station (545Watts) Solar PV Module Mono type, 5 KVA inverter type, mounting, structures alongwith connected accessories . The total solar PV array capacity should not be less than 5 KWp and should comprise of Monocrystalline minimum 200 Wp and above wattage, Module capacity minimium 200 watts. The module type must be qualified as per IEC 61215/IS 14286 latest edition for Crystalline silicon PV module. SPV module conversion efficiency should be equal to or greater than 13-14% under STC.Modules must qualify to IEC 61730 part I and II for safety qualification testing, certificate for module qualification from IEC or equivalent to be submitted as part of the bid offer,undertaking from manufacturer/supplier that the modules being supplied are as per above specification/details.The PV module shall perform satisfactorily in humidity upto 100% with temperature between -40 degree C to +85 degree C.The module would be used in a high voltage circuit, the high voltage insulation test shallbe carried out on each module anda test certificate to that effect provided. |
| 8 | Design, Supply, testing and commissioing of nverter type 5 KW at BUILDING NO. P-35 OFFICER MESS Talbehat Mil station (545Watts) Solar PV Module Mono type, 5 KVA inverter type, mounting, structures alongwith connected accessories . The total solar PV array capacity should not be less than 5 KWp and should comprise of Monocrystalline minimum 200 Wp and above wattage, Module capacity minimium 200 watts. The module type must be qualified as per IEC 61215/IS 14286 latest edition for Crystalline silicon PV module. SPV module conversion efficiency should be equal to or greater than 13-14% under STC.Modules must qualify to IEC 61730 part I and II for safety qualification testing, certificate for module qualification from IEC or equivalent to be submitted as part of the bid offer,undertaking from manufacturer/supplier that the modules being supplied are as per above specification/details.The PV module shall perform satisfactorily in humidity upto 100% with temperature between -40 degree C to +85 degree C.The module would be used in a high voltage circuit, the high voltage insulation test shallbe carried out on each module anda test certificate to that effect provided. |
| 9 | Design, Supply, testing and commissioing ofinverter type 5 KW at BUILDING NO. P-10 OR LIVING LINETalbehat Mil station (545Watts) Solar PV Module Mono type, 5 KVA inverter type, mounting, structures alongwith connected accessories . The total solar PV array capacity should not be less than 5 KWp and should comprise of Monocrystalline minimum 200 Wp and above wattage, Module capacity minimium 200 watts. The module type must be qualified as per IEC 61215/IS 14286 latest edition for Crystalline silicon PV module. SPV module conversion efficiency should be equal to or greater than 13-14% under STC. Modules must qualify to IEC 61730 part I and II for safety qualification testing, certificate for module qualification from IEC or equivalent to be submitted as part of the bid offer,undertaking from manufacturer/supplier that the modules being supplied are as per above specification/details.The PV module shall perform satisfactorily in humidity upto 100% with temperature between -40 degree C to +85 degree C.The module would be used in a high voltage circuit, the high voltage insulation test shallbe carried out on each module anda test certificate to that effect provided. |
| 10 | Design, Supply, testing and commissioing ofinverter type 5 KW at BUILDING NO. P-19 ADM BLOCKTalbehat Mil station (545Watts) Solar PV Module Mono type, 5 KVA inverter type, mounting, structures alongwith connected accessories . The total solar PV array capacity should not be less than 5 KWp and should comprise of Monocrystalline minimum 200 Wp and above wattage, Module capacity minimium 200 watts. The module type must be qualified as per IEC 61215/IS 14286 latest edition for Crystalline silicon PV module. SPV module conversion efficiency should be equal to or greater than 13-14% under STC. Modules must qualify to IEC 61730 part I and II for safety qualification testing, certificate for module qualification from IEC or equivalent to be submitted as part of the bid offer,undertaking from manufacturer/supplier that the modules being supplied are as per above specification/details.The PV module shall perform satisfactorily in humidity upto 100% with temperature between -40 degree C to +85 degree C.The module would be used in a high voltage circuit, the high voltage insulation test shallbe carried out on each module anda test certificate to that effect provided. |
| 11 | Design, Supply, testing and commissioing ofinverter type 5 KW at BUILDING NO. P-30 COOK HOUSE Talbehat Mil station (545Watts) Solar PV Module Mono type, 5 KVA inverter type, mounting, structures alongwith connected accessories . The total solar PV array capacity should not be less than 5 KWp and should comprise of Monocrystalline minimum 200 Wp and above wattage, Module capacity minimium 200 watts. The module type must be qualified as per IEC 61215/IS 14286 latest edition for Crystalline silicon PV module. SPV module conversion efficiency should be equal to or greater than 13-14% under STC. Modules must qualify to IEC 61730 part I and II for safety qualification testing, certificate for module qualification from IEC or equivalent to be submitted as part of the bid offer,undertaking from manufacturer/supplier that the modules being supplied are as per above specification/details.The PV module shall perform satisfactorily in humidity upto 100% with temperature between -40 degree C to +85 degree C.The module would be used in a high voltage circuit, the high voltage insulation test shallbe carried out on each module anda test certificate to that effect provided. |
| 12 | Design, Supply, testing and commissioing of inverter type 5 KW BUILDING NO. P-8 COOK HOUSE Talbehat Mil station (545Watts) Solar PV Module Mono type, 5 KVA inverter type, mounting, structures alongwith connected accessories . The total solar PV array capacity should not be less than 5 KWp and should comprise of Monocrystalline minimum 200 Wp and above wattage, Module capacity minimium 200 watts. The module type must be qualified as per IEC 61215/IS 14286 latest edition for Crystalline silicon PV module. SPV module conversion efficiency should be equal to or greater than 13-14% under STC. Modules must qualify to IEC 61730 part I and II for safety qualification testing, certificate for module qualification from IEC or equivalent to be submitted as part of the bid offer,undertaking from manufacturer/supplier that the modules being supplied are as per above specification/details.The PV module shall perform satisfactorily in humidity upto 100% with temperature between -40 degree C to +85 degree C.The module would be used in a high voltage circuit, the high voltage insulation test shallbe carried out on each module anda test certificate to that effect provided. |
| 13 | Design, Supply, testing and commissioing ofinverter type 5 KW at BUILDING NO. P-5OFFICE COMPLEXTalbehat Mil station (545Watts) Solar PV Module Mono type, 5 KVA inverter type, mounting, structures alongwith connected accessories . The total solar PV array capacity should not be less than 5 KWp and should comprise of Monocrystalline minimum 200 Wp and above wattage, Module capacity minimium 200 watts. The module type must be qualified as per IEC 61215/IS 14286 latest edition for Crystalline silicon PV module. SPV module conversion efficiency should be equal to or greater than 13-14% under STC. Modules must qualify to IEC 61730 part I and II for safety qualification testing, certificate for module qualification from IEC or equivalent to be submitted as part of the bid offer,undertaking from manufacturer/supplier that the modules being supplied are as per above specification/details.The PV module shall perform satisfactorily in humidity upto 100% with temperature between -40 degree C to +85 degree C.The module would be used in a high voltage circuit, the high voltage insulation test shallbe carried out on each module anda test certificate to that effect provided. |
| 14 | Design, Supply, testing and commissioing ofinverter type 5 KW at BUILDING NO. P-54 OR LIVING LINE Talbehat Mil station (545Watts) Solar PV Module Mono type, 5 KVA inverter type, mounting, structures alongwith connected accessories . The total solar PV array capacity should not be less than 5 KWp and should comprise of Monocrystalline minimum 200 Wp and above wattage, Module capacity minimium 200 watts. The module type must be qualified as per IEC 61215/IS 14286 latest edition for Crystalline silicon PV module. SPV module conversion efficiency should be equal to or greater than 13-14% under STC. Modules must qualify to IEC 61730 part I and II for safety qualification testing, certificate for module qualification from IEC or equivalent to be submitted as part of the bid offer,undertaking from manufacturer/supplier that the modules being supplied are as per above specification/details.The PV module shall perform satisfactorily in humidity upto 100% with temperature between -40 degree C to +85 degree C.The module would be used in a high voltage circuit, the high voltage insulation test shallbe carried out on each module anda test certificate to that effect provided. |
| 15 | For Ser Item No 2.00 to 14.00Make of Solar Panel shall be as per MNRE specification/standard and registered in ALMM Make of Inverter : Fuji Solar/ Invertek Energy/ GKM Energy/ Microtek/ UTL Solar/ Luminious/ Fronius/ GoodweMake of Lithium Battery : Fujitec/ GKM Solar/ UTL/ Exide Industries/ Okaya Power/ Amara Raja/ HBL Power System/ Panasonic |
| 16 | For Ser Item No 2.00 to 14.00The Roof Top solar system 5 KW Capacity shall comprise of following :-(a)SPV modules for a total capacity of 5 KW as per specification- 1 set(b)SPV Module mounting structure suitable for5 KW capacity SPV modules as per specifications on roof of building - 1 set(c)PCUs as per specifications- 1set(d)Arrayand Main junction boxes- 1 set(e)Data logging system with remote monitoring as per specification- 1set(f)AC/DC distribution as per specification -1 set(g)Lighting arrester complete set as per specification - 1 set(h)Earthing complete set as per specification- 1 set(j)Fire extinguisher in accordance with BIS codes for electrical short circuit fires along with sand buckets - 1 set(k)Lithium Battery bank as per specification of 48 V 100 AH - 01 No(l) Fuses, transfer switches printed circuit boardsrequired for power point- 1 set(m) Operation of the SPV power plant for a period of 1 month from date of commissioing of the plant(n) Engineering, electrical drawings & installations and O&M manuals to be handed over to the department before completion of the work(o)Structural material shall be corrosion resistant and electrolytically compatible with material used in the module frame, its fasteners, nuts, bolts, Galvanizing should meet ASTM A -123 hot dipped galvanizing or equivalent which provides at least sparying thickness of 70 microns on steel as per IS 5905, if steel frame is used.Aluminium frame structures with adequate strength and in accordance with relevant BIS/international standards cal also be used.Contd..../- |
| 17 | (p)Structures shall be supplied complete with all members to be compatible for allowing easy installation at the rooftop site.(q)Each Structures/Panel frame structure is so fabricated as to be fixed on the from top, The structure should be capable of withstanding a wind load of 200 km/hr after grounting & installation. Structure shall a have a provision to adjust its angle of inclination to the horizontal as per the site conditions.The front end of the solar array must be one meter above the ground. Grounting material for SPV structure shall be as per M15 concrete specifications(r)Danger boards should be provided as and where necessary as per IE Act/IE rules as amended upto date. Three signages shall be provided one each at battery-cum-control room solar array area and maint entry from administrative block,Text of the signages may be finalized in consultation with NRHM (s)A suitable battery rack with interconnections & end connector shall be provided to suitably house the batteries in the bank.The features and dimensions of the battery rack shall be provided along with the bid documents(t) Complete wiring from Changeover to user\"s end (Equipment’s)building wise and testing complete |
| 18 | For Ser Item No 2.00 to 14.00Common Technical SpecificationControl type :Voltage source, microprocessor assisted , output regulationOutput Voltage :1 Phase ,m230V ac (+12.5%-20%V ac)Frequency :50 Hz (+3Hz,-3Hz)Continuous rating:5 KVA inverterNominal power:5 KVATotal Harmonic Distortion:less rthan 3%Operating termperature Range:0 to 55 deg CHousing Cabinet :PCU to be housed in suitable switch cabinet withIP-20 ratingof ingress perotectionPCU efficiency:94% and above at full loadPower control :MPPT |