|
| 1 | Dismantling of AC/GI plain/Corrugated / semi corrugated roof sheets any type and any size complete all as specified and directed. |
| 2 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and directed. |
| 3 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed by Engineer-in-Charge. |
| 4 | S&F Mild steel workin tubular poles & trusses (framed) including purlins,rafters and special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS-1161-1979 grade St-240 complete all as specified and as directed by Engineer-in-Charge. |
| 5 | S & F steel Fe-410-W (Gde 250 Quality-A) work in tubular stanchion/postincluding special shaped washer etc. complete using one of more tubes or induction butt welded tubes conforming to IS-1161- 1979 grade St.-240 ,complete all as specified and directed. |
| 6 | S&F mild steel work Fe-410-W (Gde 250 Quality-A) in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment,complete all as specified and directed. |
| 7 | M&L for MS Framed work of Fe 410 W (Gde-E-250) Quality A, as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing ,complete all as specified and directed. |
| 8 | M&L for preparationof new/old or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 9 | Excavation in post holes (or similar holes) each n exc. 0.5cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layer n.exc. 25cm complete all as specified |
| 10 | Demolition of reinforced cement concrete of any description and in any position such as in RCC post or in RCC walls below or above ground floor complete all as specified and directed. |
| 11 | Providing reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area n exc 100 sq. cm, with or without chamfered angles and flat, splayed, rounded or mitred tops ,complete all as specified and directed. |
| 12 | M&L for Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:4 complete all as specified and directed. |
| 13 | M&L Hard core of gauge n.exc 63 mm, deposited, spread, levelled in layers not exc 15 cm thick, watered and well rammed to a true surface ,complete all as specified and directed. |
| 14 | Moorum / Red bajri filling in floors or pavings, laid in layers n.exc15 cm thick spread levelled and rammed incl watering etcall as specified & directed. |
| 15 | Demolition of cement concrete unreinforced in ground floor and paving not exc 15cm thick (below or above ground level) complete all as specified and directed. |
| 16 | M & L P:C:C 1:4:8 Type D2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 17 | M&L for 100 mm thick Cement concrete 1:4:8type D-2using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 18 | M&L for 100 mm thick Cement concrete 1:2:4type B-1using 20 mm graded stone aggregate as in flooring incl finished cement concrete surface even and smooth with extra cement complete all as specified and directed. |
| 19 | M&L for 50 mm thick Cement concrete 1:2:4type B-1using 20 mm graded stone aggregate as in flooring incl finished cement concrete surface even and smooth complete all as specified and directed. |
| 20 | M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in surface channels and drains complete all as specified and directed. |
| 21 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed. |
| 22 | M&L forPrepolished Chequered cement concrete tiles of size 200 mm x 200 mm x 25 mm thick set jointed and pointed in neat cement slurry in floor and cut and polished with grey cement and pigment, including 20 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 23 | Providing and laying 60mm thick factory made chamfered edge Pre polished cement concrete interlocking paver block of M-35 grade with approved colour,design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified. |
| 24 | M&L for Vitrified Parking tiles of size 300 mm x 300 mm x 10 mmthick set jointed and pointed in neat cement slurry in floor and cut and polished with grey cement and pigment, incl 20 mm thick screed bed in CM 1:4 complete all as specified and directed |
| 25 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 26 | M&L for walling of squared rubble, regular coursed, well bonded, bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed. |
| 27 | M&L old size Brick work using fly ash bricks straightor curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 28 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick workor concrete surfaceof walland to be finished even and smooth with out using extra cement complete all as specified and directed |
| 29 | M&L for rendering 15mm thick in CM 1:6 on other than fair faces of brick workor concrete surfaceof walland to be finished even and smooth with out using extra cement complete all as specified and directed |
| 30 | M&L TMT bar 10 mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 31 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 10cm and n exc 15cm long and dia of neck 11 mm to 15 mm |
| 32 | S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) |
| 33 | Dismantling fencing wire mesh any size or type,and removing the site complete all speciified and directed |
| 34 | S&F PVC insulated chain link fencing including line wire of size 3.15 mm dia and 100x100 mm mesh made up in mattresses or cases, lapped wire and laid in position to RCC fenccing and straining and fixing to any type of posts, straining bolts, standard bolt, incl securing or tying at crossing with and including provision of galvanized mild steel wire sraples or steel pins etc complete all as specified and directed (each line of wire to be measured for the purpose of payment) |
| 35 | S&F Flat Iron strip 40 mm x 6 mm for securing chain link fencing with RCC posts incl drilling holes, notching for wire etc.for inserting bolts incl all necessary drilling, bolting or riveting etc. ,complete all as specified and directed. |
| 36 | M&L fortwo coats of white wash on previously untreated (new)/old surface of RCC posts or bk wall incl preparation of surface complete |
| 37 | M&L for Preparation of old surfaces of Wall and applying One coat of white wash over old decorated surface of wallsall as specified and directed by Engineer-in-Charge. |
| 38 | M&L for preparation of old distempered surfaces of walls and applying one coat of oil bound distemper on walls all as specified and directed. |
| 39 | M&L for Preparation of old surfaces of Wall and applying one coat of Cement Base Paint on wallsall as specified and directed by Engineer-in-Charge. |
| 40 | M&L for preparing old plastered surfaces of walls, Facias, cornices etc and apply one coat of weather proof exterior emultion (Make as approved by GE) Complete all as specified and directed. |
| 41 | M&L for preparation of old plastered surfaces of ceilings and apply one coat of white wash complete all as specified and directed. |
| 42 | M&L for preparation of old painted surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply one coat of synthetic enamel paint complete all as specified and directed. |
| 43 | M&L for Preparation of Newly Plastered surfaces of Wall and applying Two coats of Oil Bound Distemper over a coat of primer all as specified and directed. |
| 44 | M&L for Preparation of Newly Plastered surfaces of Wall and applying Two coats of White Wash all as specified and directed. |
| 45 | Taking down rolling shutters of any size complete all as specified & directed |
| 46 | S&F in repair MS pipe 50 to 125 mm dia as shaft including two coats of synthetic enamel paint paint over a coat of red oxide primer complete all as specifed& directed. |
| 47 | S&F in repair part of steel rolling shutters MS gear box set general complete incl handle and anchoring rod as of approved quality ,complete all as specified and directed. |
| 48 | S&F in repairBall bearing suitable for rolling shutter complete all as specified and directed. |
| 49 | S&F in repair Guide channel 3\" (3.50 mm thick) mild steel deep channel section etc.complete all as specified and directed. |
| 50 | S&F in repair Hood Cover made of 1 mm thick GI Sheet pattern ,complete all as specified and directed. |
| 51 | S&F in repairBottom plate 5\" (2.25mm) complete all as specified and directed. |
| 52 | S&F in repairAnchoring rod of 25 mm dia of MS pipe complete all as specified and directed. |
| 53 | S&F in repair Safety lever locks MS with 4 levers complete all as specified and directed. |
| 54 | S & F in repair 1.00 mm thick mild steel rolling shutter strips duly pressed on both ends of vertical sides for interlocking locks for the required length of existing shutter ,complete all as specified and directed. |
| 55 | Taking down and refixing in the same opening steel rolling shutter including oiling and greasing to required necessary fittings to functional shutters as required bush, Spring, MS pipe, rod lock,ball bearing, top cover, anchoring rod, hasp and staple and push pull or gear operating system, bevel gear box and crank handle etc complete all as specified and directed. (Note : Necessary constituent items required during repair of rolling shutter shall be paid seprately as given above.) |
| 56 | Taking down existing water proofing treatment/membrane of any type and Cleaning the surface of roof, to remove all loose dirt etc and preparing the surface ,complete all as specified and directed. |
| 57 | M&L for rendering 15 mm thick surface as in roof with integral water proofing compound @ 3% by the weight of cement in CM 1:4 complete all as specified & directed. (Integral WPC will be measured and paid separately). |
| 58 | M&L for water proofing treatment to roof surface complete all as specified & directed by Engr-in-Charge laid with following course of descrition below :- :-(a)Apply evenly bituminous based primer confirming to IS: 3384-1965 @ 0.30 kg/sqm. (b)APP modified bituminous membrane 3mm thick with non woven polyester core of weight not less than 3.2 to 3.5 Kg/sqm laid and bonded to the sub strata by heat process, over laps of 100mm both in longitudinal and lateral direction shall be sealed/fused by flame torch application as per manufacturer instructions. (c)Applying bituminous based aluminiumpaint @ 0.20 Kgs/Sqm in two coats over APP membrane |
| 59 | Supply only water proofing compound , ISI marked ,complete all as specified and directed. |
| 60 | Dismantling post or struts embedded in concrete, brick work, masonry etc (wood, steel or R.C.C) any section, including taking out embeded portion and making good disturbed ground,complete all as specified and directed. |
| 61 | M & L for carrying out in repairs primary & secondary injection test of 33 KV or 11 KV indoor /outdoor type current transformer (Set of three) of VCB\"s by using standard injection test method and checking the electrical circuits for fault condition, all relay testing andproper functioning incl submittingthe test report all as directed |
| 62 | M & L for carrying out in repairs secondary injection test of 11 KV indoor /outdoor type RMU\"s by using standard injection test method and checking the electrical circuits for fault condition, all relay testing andproper functioningsubmitting test report ,complete all as specified and directed. |
| 63 | M & L for servicing in repairs 11KV VCB / bus couplerby dismantling cleaninggreasing the complete VCB with attached relays bus bar etc insulation testing, setting the contact gap by measuring as required reassembling the VCBand reinstalling back to its original positionchecking and repairing the currentcircuit panel wiring, replacement of new spares as required completeincluding operational testing and commissioning all as directed. (Note : New spares will be measured and paid separately under relavent item of this schedule) |
| 64 | M & L for servicing in repairs 11KV RMU cleaningthe complete RMU with attached relays bus bar, bush insulators with CRC spray complete etc insulation testing, required completeincluding operational testing and commissioning all as directed. (Note : New spares will be measured and paid separately under relavent item of this schedule) |
| 65 | Supply and fixing in repalcement of Earth Fault and over current relay of suitable model and make as per existing complete all as specified and directed. |
| 66 | Supply and fixing in replacement of Digital type Voltmeter / Ammeter as per suitable make and size to accommodate the existing complete all as specified and directed |
| 67 | Supply and fixing in replacement of LED type indicator lamp assembly complete all as specified and directed |
| 68 | Supply and fixing in replacement of Epoxy insulators bushings for incoming / out going cables / bus bar suppors as per existng size of VCBs complete all as speicified and directed |
| 69 | Supply and fixing in replacement of Spring charging motor for VCBs complete all as specified and directed. |
| 70 | Supply and fixing in replacment of Metering and protection current transformer epoxy/resin filled of 11 KV grade of ratio 100-50/5 class = 5P, 10/1 25 VA draw out type with necessary mounting and connected items. |
| 71 | S&F in repairs contact pressing spring for VCBs complete all as specified and directed |
| 72 | S&F in repairs Aux switch for VCBs complete all as specified and directed |
| 73 | S&F in repairs closing lever for VCBs complete all as specified and directed |
| 74 | S&F in repairs Aux circuit plug for VCBs complete all as specified and directed |
| 75 | S&F in repairs closing spring charge indicator for VCBs complete all as specified and directed |
| 76 | S & F in repairscable jointing kit for 11KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm ,complete all as specified and directed. |
| 77 | S & F in repairs cable jointing kit for 11KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm ,complete all as specified and directed. |
| 78 | S & F in repairscable jointing kit for 11KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm ,complete all as specified and directed. |
| 79 | Supply & Lay , testing and commissioning XLPE cable , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), 3 core 95 sqmm laid in trenches / floor / duct / fixed on poles / through GI tubing in different locations / areas,complete all as specified and directed. |
| 80 | Excavating in trenches not exceeding 1.5 meter wide and not exceeding1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in hard / dense soil all as specified and directed. |
| 81 | Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata,complete all as specified and directed. |
| 82 | Removing excavated soil to a distance n.exc 50m, depositing where directedat a level n.exc 1.5M above the starting point ,complete all as specified and directed. |
| 83 | Supply/ Lay dry river sand /m -sand in trenches for cable protection ,complete all as specified and directed.Note : Punned thickness only will be measured & Paid |
| 84 | Supplying & laying ofprecast concrete cable cover, class HV, type 1 peak type size 300mmx180mmx40mm complete all as specified and directed.. |
| 85 | S & F intrench/on wall in repairs GItubing light grade for road crossing and cable protection of the 100 mm diasizes as in repairs ,complete all as specified and directed. |
| 86 | Boring of holes horizontally for laying of 100mmdia pipe (minimum depth 0.60 Mtr from top level) under road, Pavement, hard standing complete all as specified and directed. |
| 87 | Supply and fixing 3 core termination bushing boots of size 70 to 120 Sqmm suitable to provide phase to phase and phase to ground insulation 11 KV volt grade complete all as specified and directed. |
| 88 | Supply, installation, testing and commissioning of power pack with battery backup for VCB panels with input voltage 110 VAC or 230 VAC +20%, -30%, input burden less than50 VA, output voltage 24DC/30VDC/110VDC/220VDC, output load 100 Watts, impulse load 450 watts for 240 mSec, battery type 12 VDC, 7AH with over voltage protection, short circuit protection complete all as specified and directed . Note:- Any specification not included in this schedule but required as per OEM standard to be provided by contractor in this quoted rate. |
| 89 | M&L in repairs battery for RMUs for indication lights showing supply of the circuitas per the existing complete all as specified and directed |
| 90 | Taking out old UNSV and Supply, laying, jointing and testing ofXLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts gradewith aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for 10 Sqmm 2 Core, including taking down old, complete, all as specified and directed |
| 91 | Supply and laying double wall corrugated (DWC) HDPE pipe 63 mm outer dia for protection of UG cable as per IS: 16205 (part 24) of 2017 complete all as specified. |