}

Tender For Estimate For Bifercation Of 11 Kv Kushumkho Pump Feeder Under Bamori Dc Of O&M Div. Guna. - Provision :- Schedule A- 11 Kv Extension For Add. Bay With Vcb - 01 No.Schedule B-11 Kv Line - 9.2 Km.Schedule C- 11 Kv Dp Structure - 13 No. 2 11 Kv , Guna-Madhya Pradesh

Tender Notice

51789612
Tender For Estimate For Bifercation Of 11 Kv Kushumkho Pump Feeder Under Bamori Dc Of O&M Div. Guna. - Provision :- Schedule A- 11 Kv Extension For Add. Bay With Vcb - 01 No.Schedule B-11 Kv Line - 9.2 Km.Schedule C- 11 Kv Dp Structure - 13 No. 2 11 Kv
Tender
Indian
Madhya Pradesh
Guna
22-10-2025

Tender Details

Tender For Estimate for Bifercation of 11 KV Kushumkho Pump feeder under Bamori Dc of O&M Div. Guna. - Provision :- Schedule A- 11 KV Extension for Add. Bay with VCB - 01 No.Schedule B-11 KV Line - 9.2 Km.Schedule C- 11 KV DP Structure - 13 No. 2 11 KV VCB, Outdoor Porcelain clad type with complete structure and accessories excluding CT & pannel 3 Handaling & Installation Charges for fixing of 11 KV VCB, Outdoor Porcelain clad type with complete structure and accessories excluding CT & pannel 4 11 KV.c.Tc. ( Outdoor dry type) 300-150/5-5 Amps 5 Handaling & Installation Charges for fixing of 11 KV.c.Tc. ( Outdoor dry type) 300-150/5-5 Amps 6 11 KV control & relay panel with numerical static ralay for double feeder frotection 7 Handaling & Installation Charges for fixing of 11 KV control & relay panel with numerical static ralay for double feeder frotection 8 Marshelling box with 10 no. connectors 9 Labour Charges for Marshelling box with 10 no. connectors 10 9 KV Gapless type (5 KA) Polymer Lightening Arrestor for 33/11 kv S/s type 11 Erection Charges for fixinf of 9 KV Gapless type (5 KA) Polymer Lightening Arrestor for 33/11 kv S/s type 12 3 phase 4 wire 3*63.5 volts ib=5 amps lmax=10 amp, HT trivector meter class of accuracy 0.5s, DLMS Compliant category A Meters along with GSM (GPRS compatible modems (For substation metering) 13 Handaling & Installation Charges for fixing of 3 phase 4 wire 3*63.5 volts ib=5 amps lmax=10 amp, HT trivector meter class of accuracy 0.5s, DLMS Compliant category A Meters along with GSM (GPRS compatible modems (For substation metering) 14 SHEET METAL METER BOX SUITABLE FOR H.T. STATIC TRAVECTOR METERS WITH TTB 15 T CLAMP FOR 33KV & 11 KV BUS, SUBSTATION upto DOG 16 labour charges for T CLAMP FOR 33KV & 11 KV BUS, SUBSTATION upto DOG 17 Clamp 65x8 mm Flat of MS Flat for H-Beam (Each weight 3.2 kg) 18 MS strain palte 65*8mm 250mm long 19 11 KV Bus-upper and lower bus including, drop jumpering and jointing with clamps, through outgoing VCB/ME/DP, upto station transformer 20 Stringing of Each 11 KV Bus-upper and lower bus including, drop jumpering and jointing with clamps, through outgoing VCB/ME/DP, upto station transformer 21 11 KV Pin Insulator Polymer Composit (5 KN) 22 Erection Charges for fixing of 11 KV Pin Insulator Polymer Composit (5 KN) 23 33 KV(45KN) Composite Polymer Disc Insulators with Hardware erection charges 24 Erection Charges for fixing of 33 KV(45KN) Composite Polymer Disc Insulators with Hardware erection charges 25 33 KV Strain Hardware (T&C type) Fittings suitable for Panther 26 Concreting of structures & foundation (1:3:6) 27 Labour Charges for Concreting of structures & foundation (1:3:6) 28 Concreting of foundation of VCB (1:3:6)@ 3.5 cmt per VCBplinth 29 Labour Charges for Concreting of foundation of VCB (1:3:6)@ 3.5 cmt per VCBplinth 30 Plinth per VCB-33KV or 11KV 31 Erection of Plinth per VCB-33KV or 11KV 32 M.S. Nut and bolts 33 Red oxide paint 34 Labour Charges for Red oxide paint 35 Aluminium Paint 36 Labour Charges for Aluminium Paint 37 Danger Boards Enamelled 33 KV 38 Erection Charges for fixing of Danger Boards Enamelled 33 KV 39 G.I. STRIP 25X3 MM1 40 G.I. Strip 25x3 mm. for laying complete earthing including welding and back filling 41 G.I.Pipe 40 mm Dia C grade type 42 G.I. Pipe 40 mm dia errection with pit digging & back filling 43 Bentonite compound powder 44 Galvanized nut & bolt with washer 45 11 KV PT Single Phase 46 Handaling & Installatin Charges for fixing of 11 KV PT Single Phase 47 DC Cross-arms 8 Channel (100x50x6MM) along withstrain plates, clamps 48 Erection Charges for Fixing of DC Cross-arms 8 Channel (100x50x6MM) along withstrain plates, clamps 49 11 KV Composite Polymer AB Swith Horizontal Movement type 50 Handling & Installation Charges for fixing of 11 KV Composite Polymer AB Swith Horizontal Movement type 51 ACSR Panther conductor 0.20 sq. inch (200 sq.mm Al.Eq.) 52 Stringing of ACSR Panther conductor 0.20 sq. inch (200 sq.mm Al.Eq.) 53 Copper Control Cable 2 Core. 2.5 Sq.mm. (Unarmoured) 54 Stringing of Copper Control Cable 2 Core. 2.5 Sq.mm. (Unarmoured) 55 Copper Control Cable 4 Core. 2.5 Sq.mm. (Unarmoured) 56 Stringing of Copper Control Cable 4 Core. 2.5 Sq.mm. (Unarmoured) 57 Copper Control Cable 8 Core. 2.5 Sq.mm. (Unarmoured) 58 Stringing of Copper Control Cable 8 Core. 2.5 Sq.mm. (Unarmoured) 59 Copper Control Cable 12 Core. 2.5 Sq.mm. (Unarmoured) 60 Stringing of Copper Control Cable 12 Core. 2.5 Sq.mm. (Unarmoured) 61 H- BEAM 9 METER 152 X 152 MM 37.1 KG/METER = 333.9 kg.(IRON STEEL SCRAP ) 62 140 kg. 8.0 mtr. Long PCC Pole 63 140 kg. 8.0 mtr. Long PCC Pole erection-[Including Pit Digging- Base padding of pole by Stone Block/Pre cost Block, pole erection, back filling/boulder, earthing coil] (Including with Transportation from Area store Guna/Gwalior/ Bhopal to working Site) 64 Back Clamp for 140 Kg PCC Pole MS Flat 50x6 mm 65 Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire 66 Stay Set Complete Without Stay wire 16 MM (Painted) Complete 67 Stay Set Complete Without Stay wire 16 MM (Painted) Complete erection including pit digging binding of stay wireat eye bolt, stay insulator and anchor rod & tighting on pole 68 Stay Wire 7/3.15 MM. (7/10 SWG) 69 Clamp for 140 KG PCC Pole MS Flat 50x6 MM 70 Stay Insulators 90X65mm 71 Back Filling of Poles with boulders 72 G.I. Wires 4.0 MM (8 SWG) 73 Labour Charges for G.I. Wires 4.0 MM (8 SWG) 74 Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay 75 labour Charges for Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay 76 11 KV Danger Boards Enamelled 77 Erection Charges for fixing of 11 KV Danger Boards Enamelled 78 11 KV V Cross arms 79 Labour Charges for Fixing of 11 KV V Cross arms 80 11 KV Top Clamp 81 Labour Charges for Fixing of 11 KV Top Clamp 82 AAAC Raccoon conductor 0.075 sq. inch. (80 sq.mm. Al.Eq.) 83 Stringing of AAAC Raccoon conductor 0.075 sq. inch. (80 sq.mm. Al.Eq.)(Including with Transportation from Area store Guna/Gwalior/ Bhopal to working Site) 84 11 KV(45KN) Composite Polymer Disc Insulators with Strain Hardware Fittings 85 Labour Charges for fixing of 11 KV(45KN) Composite Polymer Disc Insulators with Strain Hardware Fittings 86 11 KV Strain Hardware Fittings 87 Earthing for PCC Pole 4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole 88 Horizonatal and Cross Bracing 8 Centre with supporting clamps on both the poles. 89 Erection Charges for fixing of 8 Centre Horizonatal and Cross Bracing with supporting clamps on both the poles. 90 GST @ 18%

Key Value

Document Fees
INR 2360 /-
Tender Value
INR 12.76 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail