| 1 | SITC of exterior rated architectural, lP66, RGBW(W=4000°K) LED Flood Light with maximum System wattage of 150watt, min system lumen output of 6900lm e 10%, 15-degree beam angle 10%, antiglare snoot, complete with integrated power supply, suitable lP66 connectors, luminairecontrolsviaDMX512withautoaddressingfor easyconfiguration.The connectivity should be of a daisy chain topology, allowing easy installation to form long run lengths. Lighting automation control equipment should be of the same company as of light fixtures.Fixture shall include Installation clamps, 5core/cat-6 or suitable control cables UV and weatherproof, other required accessories & hardware. The luminaire housing shall be die-cast Aluminium with Electrostatically applied polyester powder coating, silicon gasket and clear tempered glass, minimum dimension of 0285mm X 225mm with bracket and minimum weight of 7kg. The Luminaire shall have tilting adjustability e 90° for whole Luminaire. The LED luminaire shall have SDCM<4 for white, the life of Luminaire shall be 50000hrs L70B50 at 35deg C. The luminaire should be lP66 & lK-06, the luminaire should have successfully passed at 3G, ANSI C136.31 vibration test (The test should be conducted and passed at3.). The operating temperature of Luminaire shall be -40°C to 50°C and storage shall be -40°C to 70°C.The LED should be discreet and not four in one & DMX Decoder should be interigated. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500hrs of salt spray test. . Manufacturers self-declaration shall be uploaded along with the technical bid confirming to compliance of CE Declaration of Conformity, CQC declaration of conformity, RoHS compliance. Test reports for the aforesaid standards for the offered product or product from the same family with power rating in the range of (+10%) shall be uploaded along with technical bid. The bidder should also submit the BIS for proposed family of product Inculding Caseing made of SS,with05 year O&M Complete in all respect. as per D/Ich. |
| 2 | SITC of exterior rated architectural, lP66, RGBW(W=4000°K) LED Flood Light with maximum System wattage of 80watt, min system lumen output of 4000lm e 10 4, 3.5-degree beam angle e 10%, antiglare snoot, complete with integrated power supply, suitable lP66 connectors, luminairecontrolsviaDMX512withautoaddressingforeasyconfiguration.The connectivity should be of a daisy chain topology, allowing easy installation to form long run lengths. Lighting automation control equipment should be of the same company as of light fixtures.Fixture shall include Installation clamps, 5core/cat-6 or suitable control cables UV and weatherproof, other required accessories & hardware. The luminaire housing shall be die-cast Aluminium with Electrostatically applied polyester powder coating, silicon gasket and clear tempered glass, minimum dimension of 0285mm X 225mm with bracket and minimum weight of 7kg. The Luminaire shall have tilting adjustability + 90° for whole Luminaire. The LED luminaire shall have SDCM<4 for white, the life of Luminaire shall be 50000hrs L70B50 at 35deg C. The luminaire should be lP66 & lK-06, the luminaire should have successfully passed at 3G, ANSI C136.31 vibration test (The test should be conducted and passed at3.). The operating temperature of Luminaire shall be -40°C to 50°C and storage shall be -40°C to 70°C.The LED should be discreet and not four in one & DMX Decoder should be interigated. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500hrs of salt spray test. . Manufacturers self-declaration shall be uploaded along with the technical bid confirming to compliance of CE Declaration of Conformity, CQC declaration of conformity, RoHS compliance. Test reports for the aforesaid standards for the offered product or product from the same family with power rating in the range of (z10%) shall be uploaded along with technical bid. The bidder should also submit the BIS for proposed family of product Inculding Caseing made of SS,with05 year O&M Complete in all respect. as per D/Ich. |
| 3 | SITC of exterior rated architectural, lP66, RGBW(W=4000°K) LED Flood Light with maximum System wattage of 80watt, min system lumen output of 4000lm • 10%, 10-degree beam angle • 10%, antiglare snoot, complete with integrated power supply, suitable lP66 connectors, luminairecontrolsviaDMX512withautoaddressingfor easyconfiguration.The connectivity should be of a daisy chain topology, allowing easy installation to form long run lengths. Lighting automation control equipment should be of the same company as of light fixtures. Fixture shall include Installation clamps, 5core/cat-6 or suitable control cables UV and weatherproof, other required accessories & hardware. The luminaire housing shall be die-cast Aluminium with Electrostatically applied polyester powder coating, silicon gasket and clear tempered glass, minimum dimension of 0225mm X 205mm with bracket and minimum weight of 7kg. The Luminaire shall have tilting adjustability + 90° for whole Luminaire. The LED luminaire shall have SDCM<4 for white, the life of Luminaire shall be 50000hrs L70B50 at 35deg C. The luminaire should be lP66 & lK-06, the luminaire should have successfully passed at 3G, ANSI C136.31 vibration test (The test should be conducted and passed at3.). The operating temperature of Luminaire shall be -40°C to 50°C and storage shall be -40°C to 70°C.The LED should be discreet and not four in one & DMX Decoder should be interigated. The LED should be discreet and not four in one & DMX Decoder should be interigated. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500hrs of salt spray test. . Manufacturers self- declaration shall be uploaded along with the technical bid confirming to compliance of CE Declaration of Conformity, CQC declaration of conformity, RoHS compliance. Test reports for the aforesaid standards for the offered product or product from the same family with power rating in the range of (z10%) shall be uploaded along with technical bid. The bidder should also submit the BIS for proposed family of product Inculding Caseing made of SS, (Grade 304)with05 year O&M Complete in all respect. as per D/Ich. |
| 4 | SITC of 1000mm long RGBW(W=4000°K) LED Rigid Linear Uplighter with System wattage of maximum 15-watt, min lumen output of 700lm, 20x30 degree beam angle, complete with integrated power supply, suitable lP66 connectors, luminaire controls via DMX512 with Auto addressing for easy configuration. The connectivity should be of a daisy chain topology, allowing easy installation to form long run lengths. The same shall include Installation clamps, 5core/cat-6 or suitable control cables UV and weatherproof, other required accessories & hardware. The luminaire shall be extruded Aluminium with Electrostatically applied polyester powder coating, silicon gasket and clear tempered glass, minimum dimension of 1000X25X35mm with bracket and minimum weight of 0.85kg. The Luminaire shall have tilting adjustability +15° to - 90°. The LED luminaire shall have SDCM<4 for white, the life of Luminaire shall be 50000hrsL70B50 at 35deg C. The luminaire should be lP66 & lK-06. The operating temperature of Luminaire shall be -40°C to 50°C and storage shall be -40°C to 70°C. The product shall comply to and shall have test repots for IEC 60598-2- 5:2015, IEC 60598-1:2014 + A1, IEC TR 62778:2014 (for LED chips), EN IEC 55015:2019+A11, EN 61547:2009, EN61000-3-2:2019, EN 61000-3-3:2013, IS 10322 (Part 5/Sec5):2013, LM80. Manufacturers self-declaration shall be uploaded along with the technical bid confirming to compliance of CE Declaration of Conformity, CQC declaration of conformity, RoHS compliance &ASTM B117 for 500 hours. The bidder should also submit the BIS for proposed family of product Inculding Caseing made of SS,with05 year O&M Complete in all respect. as per D/Ich. |
| 5 | SITC of 1000mm long RGBW(W=4000°K) LED Rigid Linear Uplighter with System wattage of maximum 50-watt, min lumen output of 1700lm, 25x40degree beam angle, complete with integrated power supply, suitable lP66 connectors, luminaire controls via DMX512 with Auto addressing for easy configuration. The connectivity should be of a daisy chain topology, allowing easy installation to form long run lengths. The same shall include Installation clamps, 5core/cat-6 or suitable control cables UV and weatherproof, other required accessories & hardware. The luminaire shall be extruded Aluminium with Electrostatically applied polyester powder coating, silicon gasket and clear tempered glass, minimum dimension of 1000X55X45mm with bracket and minimum weight of 4kg. The Luminaire shall have tilting adjustability +15° to - 90°. The LED luminaire shall have SDCM<4 for white, the life of Luminaire shall be 50000hrs L70B50 at 35 deg C The luminaire should be lP66 & lK-06. The operating temperature of Luminaire shall be -40°C to 50°C and storage shall be -40°C to 70°C. The LED should be discreet and not four in one & DMX Decoder should be interigated. The product shall comply to and shall have test repots for IEC 60598-2-5:2015, IEC 60598-1:2014 + A1, IEC TR 62778:2014 (for LED chips), EN IEC 55015:2019+A11, EN 61547:2009, EN 61000-3-2:2019, EN 61000-3-3:2013, IS 10322 (Part5/Sec5):2013, LM80. Manufacturers self-declaration shall be uploaded along with the technical bid confirming to compliance of CE Declaration of Conformity, CQC declaration of conformity, RoHS compliance & ASTM B117 for 500 hours. The bidder should also submit the BIS for proposed family of product Inculding Caseing made of SS,with05 year O&M Complete in all respect. as per D/Ich. |
| 6 | SITCof controller to author, configure, and control dynamic LED light shows for DMX lighting networks. The controller with two universe of DMX ports control up to 340 light addresses, Works as a stand-alone or computer- driven controller, Secure Digital (SD) card drive for flexible show storage , USB 2.0 interface for downloading shows and configuring from attached PC or Mac, Simple installation and wiring is required, Flexible, adaptable mountingoptions are expected, Should be provided with light show authoring software, Direct line voltage power supports 100—240 VAC , Six configurable effects — Using light show authoring sofMare to select from six effects, adjust effect settings, such as color, speed, and brightness etc as reqd. The DMX controller and software should be from the same manufacturer as the proposed luminaire Inculding Caseing made of SS,with05 year O&M Complete in all respect. as per D/Ich. |
| 7 | • Addressing Kit shall automatically write address to a whole group of interconnectingluminaires within minutes. It shall be Miniature industrial design, compact size and touch screen. It can be powered by a power bank with a Micro-B type USB port for on-site programming and testing after installation. The housing shall be extruded Aluminum with black finish weighing approx. 0.2Kgwith temperature range-10°C to 40°C, input voltage of 6-24V DC and humidity range of 1Oto 90% (no condensation). The product shall be compact in size, compatible with multiple types DMX512 chips, with Built-in test animation effects, SD card slot to store animation and scenes. The addressing kit shall support standard RDM protocol, searching for RDM luminaires and static detection, Color-pickfunctions, and can be powered by Micro-B type USB power supplyInculding Caseing made of SS,Inculding Caseing made of SS,with05 year O&M Complete in all respect. as per D/Ich. |
| 8 | SITC of compact DMX signal splitter cum amplifier that takes the incoming DMX51 2/RDM signal and amplify the signal and supporting bi-directionalcommunications for discovery, addressing and DMX control of Iightfixtures.This unit takes the incoming DMX/RDM signal and splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6 X 32. The output terminals are electronically isolated from the input & RDM-through port and share a common ground reference. All six output ports have an independent output driver to boost the DMX/RDM signal. Operating temperature shall be -10° to 35°C. The maximum power consumption shall be less than 4.5W and input voltage shall be 12-24V DC. Inculding Caseing made of SS,with05 year O&M Complete in all respect. as per D/Ich. |
| 9 | Programming, testing and commissioning of RGB lights with schene creation (5-7Nos)Testing, commission, and program lighting fixtures according to the consultant/architect\"s requirements and standards, follow these steps:1. Review Requirements: - Obtain detailed requirements and standards.,- Understand the desired lighting scenes and themes for each area. 2. Planning: - Develop a plan outlining the sequence of testing and commissioning, - Identify all DMX-controlled lighting fixtures and their locations, - Plan the different lighting scenes and themes that need to be designed. 3. Installation Verification:- Ensure all lighting fixtures are installed correctly and securely, - Check the wiring and connections for DMX controllers and fixtures. 4. Programming DMX Controllers:- Set up DMX controllers and configure them according to the lighting design plan. - Program the controllers to create multiple lighting scenes and themes,- Ensure each fixture responds correctly to DMX signals.5. Testing and Commissioning: - Test each lighting fixture individually to ensure proper operation, - Verify that the programmed scenes and themes are executed correctly, - Adjust programming as needed to meet the design specifications. 6. Approval Process: - Present the programmed lighting scenes and themes to the consultant/architect for approval, - Make any required adjustments based on feedback, 7. Documentation and Training: - Document the programming and commissioning process,- Provide training to relevant personnel on how to operate and maintain the lighting system.8. Final Verification: - Conduct a final walkthrough with the consultant/architect to ensure all requirements are met.- Obtain final approval and sign-off. Inculding Caseing made of SS,with05 year O&M Complete in all respect. as per D/Ich. |
| 10 | Design, manufacture, testing at works, supply & commissioning of following floor / wall mounting cubicle type feeder pillar(IP65) with following details UV/fire/acid-chemical resistant/anti )corrosive/dust/water /shock proof(IP67)with ice 61439-1 clause 102.4 incoming cable entry from bottom /left/right sidewith all accessories copper bus bar, din rail earth links, neutrallink, gland, lock, connectors, thimble etc. complete with all respects. Incomer 100A 3 pole MCCB, VOLTAGE CUT OFF relay, neutral failure protection relay, astronomical timer with 100?contactor, bypass switch, RYB LED indication, volts, amp, digital ammeter 1 set & outgoing 3 pole 20A 14 nos SITC of copper wounded natural oil cooled servo voltage, rolling contact, oilcooled, outdoor canopy with following rating 3 phase 50hz. Efficiency unbalanced input voltage & unbalanced load, volt/ampere meter CT\"s bypass. Make- Genco |
| 11 | SITC , Installation and testing of 3 Phase Servo Stablizer with minimum capicity of 30KVA, Oil cooled with 180 -260.VAC Totally insulated & enclosed floor/wall maunting cubicle type feedr piller (ip 65) with follwing properites :-uv/fire/acid-chemical resistant/anti corrosive/dust/water/weather/shock proof (ip65/66) in accordance with iec 61439-1 clause 10.2.4 incoming cable entry from bottom/left/right side of panel as per details design and cable entry and outgoing are only with suitable sizes of screw less glands including with all accessories copper bus bar, din rails earth links, neutral links, glands , locks , connectors, thimbles, connecters etc. complete with all respects. Incomer 100a 3 pole mccb, high/low voltage cut off relay, neutral failure protection relay, astronomical timer with 100a contactor, 100 a bypass switch, ryb led indicators, volts/amp digtal meters-1-set & outgoing 3 pole 20a - 14 nossupply, installation, testing and commissionig of copper wounded natural oil cooled servo voltage stabilzer, type linear rolling contact, oil colled, outdoor canopy with following ratings 3-phase 50hz. efficiency 95% unbalanced input voltage and unbalanced load, volt/ampere meter ct\" s, bypasswith05 year O&M Complete in all respect. as per D/Ich. |
| 12 | SITC and laying of 2.5 Sq mm 3 core PVC insulated unarmoured multistrand copper cable as per site requirement Inculdingwith05 year O&M Complete in all respect. as per D/Ich. |
| 13 | SITC and laying of 6 Sq mm 5 core PVC insulated unarmoured copper cable as per site requirement Inculdingwith05 year O&M Complete in all respect. as per D/Ich. |
| 14 | SITC and laying of Armoured CAT 6 cable as per site requirement Inculdingwith05 year O&M Complete in all respect. as per D/Ich. |
| 15 | SITC and Laying of PVC/HDPE pipe 32 MM as per site requirement Inculdingwith05 year O&M Complete in all respect. as per D/Ich. |
| 16 | SITC and fixing lP 67 boxes with all accessories as per site requirement Inculdingwith05 year O&M Complete in all respect. as per D/Ich. h. |
| 17 | Supply and burying of 600mm x 600mm x 3mm copperplate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipeand funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15mm dia G.I. pipe up to switchboard (from appron to switch board the cost ofG.I. pipeand copper wire will be extra) 30cm square C.I. framewith hinged cover masonry housing alternate layers ofcharcoal/coke and salt at least 150mm thick alround etc. complete in all respect. ( Pwd Schedule 2018 item no 705 ) |
| 18 | Supplyandlayingof AluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. SI 501/2018Deduct in all item Deduct in all items (items No. 507 Rs 170.0010 Sqmm 4 Core |
| 19 | 35 Sqmm 3-1/2 |