| 1 | Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified. |
| 2 | M&L for Autoclaved aerated concrete (AAC blocks) for masonry fixed with Ready Mix Jointing Mortar complete all as specified and as directed Makes/brands of Ready Mix Jointing Mortar shall be “Speed Dry Mix”/ “DUBOND”/ “MAGIC BOND”/ BUILDWELL”. Makes/Manufacturers of AAC blocks :AEROCON/Ecolite/ ISI marked Grade I as approved by GE. |
| 3 | M&L for brick work with fly ash old size bricks, straight or curved on plan n.exc 6m mean radius, built in cm 1:6 complete all as specified and directed. |
| 4 | Taking down cement mortar/plastering on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, incl removing of surbs vegetation for up to working space etc. |
| 5 | M&L for rendering 15mm thick as in External plaster with ready mix plaster on brick or concrete or stone masonry or AAC block masonry surfaces,complete all as specified and as directed. |
| 6 | M&L for preparation of new plastered/concrete surfaces of wall and applying two coats of cement base paint over chalk whitening incl curing to surfaces complete all as specified and directed. |
| 7 | Dismantling of posts or struts (wood, steel or RCC) any section embadded in concrete, including taking out embedded portion and making good disturbed groundall as specified and as directed. |
| 8 | Dismantling of fencing wire mesh, barbed wire any type complete all asspecified and directed. |
| 9 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in any type of soilcomplete all as specified and directed incl clearing all grass,vegetation, shrubs etc. |
| 10 | Material and labour for PCC (1:4:8), type C-2 using 40 mm graded stone aggregate as in posts (including caps & bases), foundations filling and sub baseincluding formwork complete all as specified and as directed by Engineer-in-charge. |
| 11 | Material and labour for PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as in coping, bed block for fixing of angle iron fencing post on wall or similar works,plinth course,string courses,lacing courses,parapets and railing,apex stone,bed plates etc including formwork complete all as specified and as directed by Engineer-in-charge. |
| 12 | S & F in repairs galvanized 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing & straining & fixing to any type of standards rails straining bolts including securing or tying at crossing with & provn of galvanized mild steel wire complete all as specified anddirected. (Each line wire to be measured). |
| 13 | Supply only chain link MS galvanized fencing of any size or type complete all as specified and as directed. |
| 14 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wire complete all as spd and directed. |
| 15 | Supply and fixing 10mm dia, exceeding 5cm and not exceeding 10cm long machine made mild steel screw bolts with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with onewasher and one hexagonal or square nut, complete all as specified & directed by Engineer-in- charge. |
| 16 | Supply and fixing mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or rivetting etc. and similar works conforming to Fe-290 (Gde E-165)complete all as specified and directed by Engineer-in-Charge. Note:- 1. Flat iron for securing wire mesh to be provided is to measured in this item. 2. Machine made screw bolt 10mm dia exceeding 5cm and not exceeding 10cm long shall be measured and paid seperately. |
| 17 | S&F mild steel round plain bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clip all as specified & directed by Engineer-in-Charge. |
| 18 | Supplied and fixed for framed work as in doors or gates of angle/hollow section or other section with gusset Plate, rails,braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges and door fittings necessary rivetting/welding cutting up complete steel conf. to Fe-410-0 or Fe-310-0 inclding ornamental design all as specified and directed.Note : Disturbed surfaces of wall shall be made good to true surface. |
| 19 | Fixing only MS gate in any type or in any description including hold fast, locking arrangement incl wheel track and sliding door bolt as required and hanging; also fastening and fixing complete |
| 20 | Dismantling structural steel work including doors, gates, fencing post etc but excluding framed trusses complete all as specified and as directed. |
| 21 | Demolation of stone slab and tiles laid bedded and pointed in any mortar description or thickness in floors, apron etc Complete all as specified and directed. |
| 22 | M & L Granite (of any type) 16-20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting andpolishing typesover 10mm thick screed bed in CM 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 23 | M&L for non abrasive paving (Rectified Endura) cement conrete coloured tiles 300 x 300mm x 8-10mm thick machine pressed, set and jointed and pointed in neat cement slurry as in floor/skirting mixed with grey cementandpigment match the colour as in pavements, including 15mm thick scred in CM 1:6, set jointed & pointed in neat cement slurry in floors complete all as specified and as directed. |
| 24 | M&L for precast cement concrete interlocking tiles 60 mm thick Rouber moulded, prepolished with strength 35 N/sqmm as in floor/pavement laid on 30 mm thick stone dust cushioning laid dry to the profile complete all as specified and as directed. |
| 25 | M&L for precast cement concrete interlocking tiles 80 mm thick Rouber moulded prepolishedwith strength 40 N/sqmm as in floor/pavement laid on 30 mm thick stone dust cushioning laid dry to the profile complete all as specified and as directed. |
| 26 | M & L forprepolished chequered cement concrete tiles 30cm x 30cm x 20mm thick Rubber moulded with grey cementandpigment, including 15 mm thick screed bed in CM 1:6, set jointed & pointed in neat cement slurry in floors complete all as specified anddirected. |
| 27 | Demolition of PCC (unreinforced) in ground floors & pavings n exc 15 cm thickness (below or above ground level) including tiles and backing coat complete. |
| 28 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide all as specified and directed. |
| 29 | Material and labour for preparation ofnew steel and iron surfaces of any description not otherwise described not exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed by Engineer-in- charge. |
| 30 | Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cesspits, manholes, laying pipe line, laying of cables or fixing poles and stays and struts etc. not exceeding 10 Sqm on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge. |
| 31 | Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge. |
| 32 | Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge. |
| 33 | S&F for 40 to 50 mm thickprecast cement concrete compound wall, planks/panels lockingeach otherlouvres and jallies as per approved design/patterns(1:3:6) TYPE C0 Set in cement mortar 1:6,(measured solid ), includingall mouldings but excluding frame as directed by Engr in charge.(Note: The quoted rate shall be inclusive of cost of reinforcement , Form work)(Note:Columns/ poles will be measured seperately) |
| 34 | M & L for preparation of old decorated (plastered or unplastered) surfaces of walls applying one coats of cement base paint colour approved by GE complete all as specified and directed. |
| 35 | M&L for preparing old steel surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed. |
| 36 | Providing and laying factory made kerb stone of size 300 mm X100 mm X 300 mmat or near ground level factory made kerb stone of cement concrete (1;1.5:3)in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 37 | M & L for precast cement concrete 1:2:4 type B-1 (using 20mm graded stone aggreates) set in CM 1:4 as in cover slabs (for manhole etc) & simillar articles with plain faces complete (Reinforcement will be measured and paid separatly) complete all as specified and directed. |
| 38 | M & LMild steel TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as spd and directed. |
| 39 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for .Note- Rate includes for reinforcement cutting as required to facilitate demolition. |
| 40 | M & L cement concrete type C2 ( 1:3:6) ( 40 mm graded agg ) as in surface channel and drains complete all as spd and directed. |
| 41 | Extrafor forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement incl forms,moulds,mitred/stopped end etc. complete all as spd and directed. |
| 42 | Extrafor forming fair finished drain or channel 45 cm inner girth in cement concrete using extra cement incl forms,moulds,mitred/stopped end etc. complete all as spd and directed. |
| 43 | M&L for preparation of surface of wall and applying two coat of exterior weather proof 100% anti fungal acrylic smooth emulsion with silicon additives over a coat of primer, exteriour weather proof offer anti alge high performance exterior wall finish applied by using Airless spray technology with max working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacture with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper, should be able to spray in hard to reach areas and penetration of distemper on the surface to achieve excellent application using limited manpower complete all as specified and directed. Make: Asian (Apex Ultima), Berger (Weather Coat), Nerolac (Excel Total). |
| 44 | M & L for Providing high tensile pre-stress precast reinforced cement concrete Grade of ConcreteM-25as in columns, posts, boundary pillars, with smooth finish including chamfers, weatherings, throating etc. and setting in cementmortar 1:4 complete with joints to match as directed and approved by GE.(Note: The quoted rate shall be deemed to inclusive of cost ofhigh tensile carbonized steel wire dia 3 to 4mm , 07 Nos steel inclall form work)MAKE :Universal or any Equivalent |
| 45 | S&F50 mm thick high tensile pre-stress precast cement concrete M-25grade wall panel as incompound wall (both Side smooth Finish), planks/panels lockingeach otherlouvres and jallies as per approved design/patterns Set in cement mortar 1:4 ,(measured solid ), includingall mouldings but excluding frame as directed asApproved by GE.(Note: The quoted rate shall be deemed to inclusive of cost ofhigh tensile carbonized steel wire dia 3 to 4mm ,04 Nos steelincl all Form work)(Note:columns/ poles will be measured seperately)MAKE :Universal or any Equivalent |
| 46 | Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges etc complete all as specified and directed. |
| 47 | Dismantling unframed work of timber scantlings 40 sqcm and over in any section, in any position complete all as specified. |
| 48 | S & Ffor steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt weided tubes conforming to I.S 1161-1998 grade St 240 complete all as specified. |
| 49 | S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified incl filling of gaps between wall and sheet with PCC 1:2:4 ( 20 mm graded agg)/ brick work CM 1:4 and plastering the surfaces with CM 1:4 on both side where required cost of the same shall be deemed to be included in quoted rate completeall as specified and directed. |
| 50 | S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified. |
| 51 | M & L two coats of synthetic enamel paint over priming with red oxide over preparation of new iron surfaces of any description over 10 cm width or girth complete all as specified and as directed. |
| 52 | Note: Amount of sch of credit of Rs.23740/-will be deducted from total amount of BOQ. |