| 1 | Taking down of cement or cement lime plaster of any description on brick work or stone walls etc including racking out joints, hacking for key scrubbing down with water etc complete & removing debris out side MOD land ,complete all as specified and directed. |
| 2 | Demolition of brick work or stone/boulder masonary built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles and rubbish off the premises ,complete all as specified and directed. |
| 3 | M&L Brick work using fly ash bricks straightor curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 4 | M&L for Rendering 15mm thick in CM 1:6 on brick or concrete surface, finishing even and smooth without using extra cement ,complete all as specified and directed. |
| 5 | M&L for rendering 5 mm thick in CM 1:3 on RCC ceiling surface and finished even and smooth with out using extra cement complete all as specified and directed . |
| 6 | M&L Rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces,second layer (finishing coat)mixed with liquid water proofing compound @ 200 ml / 50 Kg bag of cement as per manufacturer\"s instructions and finish the surfaces even and smooth without using extra cement including WPC complete all as specified and directed. |
| 7 | M&L for applying 2mm thick cementPutty in two layers on newly plastered wall and ceiling surfaces absolutely even and smooth, rubbing with sand paper complete all as specified and directed. |
| 8 | M&L for applying 2mm thick cement Putty in two layers on old wall surfaces including complete removal of existing wall finish of any type with wire brush, brooming, dusting and finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, rubbing with sand paper complete all as specified and directed. |
| 9 | M&L for applying 2mm thick cement Putty in two layers on old ceiling surfaces including complete removal of existing wall finish of any type with wire brush, brooming, dusting and finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, rubbing with sand paper complete all as specified and directed. |
| 10 | M&L for preparation of newly plastered surfaces ofceiling andapplying two coats ofdistemper-oil-emulsion over a coat of primercomplete all as specified and as directed. |
| 11 | M&L for applying two coats of oil bound distemper on ceiling over a coat of primer on prepared surfaces including, rubbing with sand paper complete all as specified and directed. |
| 12 | M&L for applying one coats of oil bound distemper on ceiling over a coat of primer on prepared surfaces including, rubbing with sand paper complete all as specified and directed. |
| 13 | M&L for applying one coats of oil bound distemper on wall or concrete over a coat of primer on prepared surfaces including, rubbing with sand paper complete all as specified and directed. |
| 14 | M&L for applying two coats of oil bound distemper on wall or concrete over a coat of primer on prepared surfaces including, rubbing with sand paper complete all as specified and directed. |
| 15 | M&L for applying one coats of weather proof anti fungal exterior emulsion paint in matt finish of make,\" Weather coatover & including one coat of water based exterior primer on prepared surface of brick (plastered or un-plastered) or concrete surface complete all as specified and directed by Engr-in-Charge. Note:-1. Work will be carried out upto 12 mtr height hence all rates are included for scafolding/ shuttering and safety precautions etc. 2.The work shall be carried out by authorised applicator/approved agency as per manufacturer instructions & contractor shall submit guarantee for 03 years for which 3% of the cost shall be retained for guarantee period.3. The work shall be carried out by using Roller. |
| 16 | M&L for applying two coats of weather proof anti fungal exterior emulsion paint in matt finish of make,\" Weather coatover & including one coat of water based exterior primer on prepared surface of brick (plastered or un-plastered) or concrete surface complete all as specified and directed by Engr-in-Charge. Note:-1. Work will be carried out upto 12 mtr height hence all rates are included for scafolding/ shuttering and safety precautions etc. 2.The work shall be carried out by authorised applicator/approved agency as per manufacturer instructions & contractor shall submit guarantee for 03 years for which 3% of the cost shall be retained for guarantee period.3. The work shall be carried out by using Roller. |
| 17 | M&L preparing of newly/old plastered or un plastered surface of walls or kerb stones and applying two coats of acrylic exterior weather proof emulsion paint over a coat of exterior primer on newly/oldkerb stone surfaces, includes complete removal dusting & finally washing with water to clean the surface absolutely free from any kind of foreign materials and etc complete all as specified and directed. |
| 18 | M&L for preparation of old painted surfaces and applying one coat of synthetic enamel paint in old fencing of ms angel posts, ms flats etc or concrete surface complete all as specified and directed. |
| 19 | M&L preparation of steel surfaces of any description n exc 10cm in width or girthand applying one coat of synthetic enamel paint for old fencing of mild steel round bars 10mm dia, ms flats etc complete all as specified and as directed by Engineer-in-Charge |
| 20 | M&L for writing letters or figures (Block, Roman, Italic or Indian) n.exc 30 cm high etc complete all as specified and as directed by Engineer-in-Charge.(Note : Rates to be deemed fit for all security measures while working in heights more than 6m from GL). |
| 21 | Cleaning and removing shrubs plants from roof, chajja, facia or brick wall complete with roots and providing ante vegitation growth chemical spray at any height and making good in CM 1:3. Complete all as specified & directed by Engr-in -Charge. |
| 22 | Cleaning and removing any type of shrubs plants grown on wall, shaft etc. complete with roots and providing ante vegitation growth chemical spray at any height and making good in CM 1:3. ,complete all as specified & directed . |
| 23 | Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr depth and getting out in looses/soft soil complete all as specified |
| 24 | Returing filling in incl spreading leveling, watering and well ramming in layer not less than 25 cum each layer all as specified. |
| 25 | Removing excavated material to a distance not exc 50M anddepositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified |
| 26 | Supply and laying double wall corrugated HDPE pipe 50mm outer dia for protection of UG cable complete all as specified |
| 27 | Taking out old UNSV and Supply, laying, jointing and testing ofXLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts gradewith aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for 10 Sqmm 2 Core., including taking down old, complete, all as specified and directed . |
| 28 | All as per item no. 27 but for 10 Sqmm 4 Core. |
| 29 | All as per item no. 27 but for16 Sqmm 4 Core. |
| 30 | All as per item no. 27 but for25 Sqmm 3.5 Core. |
| 31 | All as per item no. 27 but for35 Sqmm 3.5 Core |
| 32 | All as per item no. 27 but for50 Sqmm 3.5 Core |
| 33 | All as per item no. 27 but for70 Sqmm 3.5 Core |
| 34 | All as per item no. 27 but for95 Sqmm 3.5 Core |
| 35 | All as per item no. 27 but for120 Sqmm 3.5 Core |
| 36 | All as per item no. 27 but for150 Sqmm 3.5 Core |
| 37 | All as per item no. 27 but for 185 Sqmm 3.5 Core |
| 38 | All as per item no. 27 but for 240 Sqmm 3.5 Core |
| 39 | M/L for replacement of Earthing complete with GI earthplate 60x60cmx6mm thick electrode and using galvanised iron strip 32 x 6 mm as earthing lead burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point all as specified and as directed by Engr-in-charge. |
| 40 | Supply and fixing of moulded case circuit breaker Four pole 100/63Amps 15 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 41 | Supply and fixing of moulded case circuit breaker Four pole 160 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 42 | Supply and fixing of moulded case circuit breaker Four pole 200 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge |
| 43 | Supply and fixing of moulded case circuit breaker Four pole 250 Amps 36 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 44 | Supply and fixing of moulded case circuit breaker Four pole 320 Amps 50 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 45 | Supply and fixing of moulded case circuit breaker Four pole 400 Amps 50 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 46 | Supply and fixing of moulded case circuit breaker Four pole 630 Amps 50 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 47 | Supply and fixing of digital voltmeter 0 to 500 volts 96 x96mm flush type in LT Panels incl taking out the old unserviceable complete allasspecifiedanddirected. |
| 48 | Supply and fixing of digital ammeter range as per existing 96 x96mm flush type in LT panels incl taking out the old unserviceable complete allasspecifiedanddirected. |
| 49 | Supply and fixing of LT current transformer ratio from 200/5 Ampsor 100/5 or 400/5 in LT panels incl taking out the old unserviceable complete allasspecifiedanddirected. Make : L&T. |
| 50 | Supply and fixingselector switch of voltmeter/ammeter in LT panel boards incl taking out the old unserviceable complete allasspecifiedanddirected. |
| 51 | Supply and fixing indicator assembly (RYB) LED type in LT panel boards incl taking out the old unserviceable ,complete allasspecifiedanddirected. |
| 52 | M&L for painting to LT panels of any size with two coats of sky blue paint over a coat of red oxide primer outerside and two coats of off white paint over a coat of red oxide primer internally complete all as specified and directed by Engr- in-Charge. Note: 1. Before painting the contractor will ask for a shut down of the recpective feeder from the JE.2. While painting of the panels protection of MCCB\"s and MCB\"s to be taken care of by the contractor.Any damage occured during the painting will be bear by the contractor. |
| 53 | S&F of Cable jointing kit for 1.1 KV (Earthed)grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 2 core XLPE armoured aluminium conductor cable of size 6-16 sqmm ,complete allasspecifiedanddirected. |
| 54 | S&F of Cable jointing kit for 1.1 KV (Earthed)grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 16-50 sqmm ,complete allasspecifiedanddirected. |
| 55 | S&F of Cable jointing kit for 1.1 KV (Earthed)grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm ,complete allasspecifiedanddirected. |
| 56 | S&F of Cable jointing kit for 1.1 KV (Earthed)grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 150 to 185 sqmm ,complete allasspecifiedanddirected. |
| 57 | Supply and fixing Aluminium tube terminal/ lugs of undermentioned 10 to 25 Sqmm ,complete allasspecifiedanddirected. |
| 58 | All as per item no. 57 but for 35 to 50 Sqmm |
| 59 | All as per item no. 57 but for70 to 120 Sqmm |
| 60 | All as per item no. 57 but for 150 to 185 Sqmm |
| 61 | Supply, installation, testing and commissioning of CPRI approved LT panel board, outdoor type, with front and back door openable type fitted with nuts, bolt and washers fitted with knob and hinges, floor mounted fabricated out of 3.00 mm thick MS sheet to be placed over pedestals in PCC 1:3:6 type C-1 cement concrete extending 300mm above ground level with one meter wide plaform in all round panel LT panel shall be totally enclosed weather proof and verming proof with front and rear opening with IP-54 protection as per IS-8623 duly powder coated for connection, RYB, insulator complete pre-wired and cable connection with copper conductor wire upto aluminium bus bar including all incoming and outgoing cable connection with suitable size of aluminium lugs/gland complete all as specified and directed by Engr-in Charge and also comprising of the following of suitable size. (i) MCCB 400 A FP, 50 KA Adjustable thermal & Fixed magnetic setting. 1 Nos. (Incoming)(ii) MCCB 200A FP, 36 KA, Adjustable thermal & Fixed magnetic setting. 2 Nos. (Outgoing) (iii) MCCB 160A FP, 36 KA, Adjustable thermal & Fixed magnetic setting. 3 Nos. (Outgoing) (iv) MCCB 100A FP, 36 KA, Adjustable thermal & Fixed magnetic setting. 2 Nos. (Outgoing) (v) MCCB 63A FP, 16 KA, Adjustable thermal & Fixed magnetic setting. 2 Nos. (Outgoing) (vi) MCB TPN 63 Amp- 03 Nos (vii) MCB SPN 40 Amp- 03 Nos (viii) Alumimiumbus bars sleeve insulated 40X10 mmTPN mounted on epoxy insulators-01 Set (ix)Digital voltmeter 0 - 500 V range with selector switch - 01 No (x) Digital ammeter 0 - 200 A range with selector switch and CTs - 01 No (xi)Indicators RYB - 01 Set(xii)Internal wiring of the panel board with single core copper cable PVC insulated of suitable size and control fuses.(xiii) Cable entry glands and two nos earthing terminals (xiv) Fabrication of LT panel board with all accessories except above and complete painting. Angle iron support made out of 50 x 50 x 6MM thick (xv) Cost of PCC, eraction incl commission etc ,complete allasspecifiedanddirected. |
| 62 | Supply, installation, testing and commissioning of CPRI approved LT panel board, outdoor type, with front and back door openable type fitted with nuts, bolt and washers fitted with knob and hinges, floor mounted fabricated out of 3.00 mm thick MS sheet to be placed over pedestals in PCC 1:3:6 type C-1 cement concrete extending 300mm above ground level. LT panel shall be totally enclosed weather proof and verming proof with front and rear opening with IP-54 protection as per IS-8623 duly powder coated for connection, RYB, insulator complete pre-wired and cable connection with copper conductor wire upto aluminium bus bar including all incoming and outgoing cable connection with suitable size of aluminium lugs/gland complete all as specified and directed by Engr-in Charge and also comprising of the following of suitable size for konark Circle S/S (i) MCCB 400 A FP, 50 KA Adjustable thermal & Fixed magnetic setting. 1 Nos. (Incoming)(ii) MCCB 200A FP, 25 KA, Adjustable thermal & Fixed magnetic setting. 4 Nos. (Outgoing)(iii) MCCB 100A FP, 16 KA, Adjustable thermal & Fixed magnetic setting. 1 Nos. (Outgoing)(iv)MCB TPN 40 A, 10 KA for street light panel control:- 01 Nos(v) Alumimiumbus bars sleeve insulated 500 amps capacity TPN mounted on epoxy insulators-01 Set(vi)Digital voltmeter 0 - 500 V range with selector switch - 01 No(vii) Digital ammeter 0 - 200 A range with selector switch and CTs - 01 No (viii)Indicators RYB - 01 Set (ix)Internal wiring of the panel board with single core copper cable PVC insulated of suitable size and control fuses. (x) Cable entry glands and two nos earthing terminals (xi) Fabrication of LT panel board with all accessories except above and complete painting. Angle iron support made out of 50 x 50 x 6MM thick (xii) Cost of PCC, eraction incl commission etc ,complete allasspecifiedanddirected. |
| 63 | Supply, installation, testing and commissioning of CPRI approved LT panel board, outdoor type, with front and back door openable type fitted with nuts, bolt and washers fitted with knob and hinges, floor mounted fabricated out of 3.00 mm thick MS sheet to be placed over pedestals in PCC 1:3:6 type C-1 cement concrete extending 300mm above ground level. LT panel shall be totally enclosed weather proof and verming proof with front and rear opening with IP-54 protection as per IS-8623 duly powder coated for connection, RYB, insulator complete pre-wired and cable connection with copper conductor wire upto aluminium bus bar including all incoming and outgoing cable connection with suitable size of aluminium lugs/gland complete all as specified and directed by Engr-in Charge and also comprising of the following of suitable size.(i) MCCB 200 A FP, 36 KA Adjustable thermal & Fixed magnetic setting. 1 Nos. (Incoming)(ii)MCCB 100A FP, 36 KA, Adjustable thermal & Fixed magnetic setting. 2 Nos. (Outgoing) (iii) MCCB 160 A FP, 16 KA, Adjustable thermal & Fixed magnetic setting. 1 Nos. (Outgoing)(iv)MCB TPN 40 A, 10 KA :- 04 Nos(v) MCB SPN 32 A, 10 KA -06 Nos (vi) Alumimiumbus bars sleeve insulated 25x10 mm TPN mounted on epoxy insulators-01 Set (vii)Digital voltmeter 0 - 500 V range with selector switch - 01 No (viii) Digital ammeter 0 - 200 A range with selector switch and CTs - 01 No (ix)Indicators RYB - 01 Set (x)Internal wiring of the panel board with single core copper cable PVC insulated of suitable size and control fuses. (xi) Cable entry glands and two nos earthing terminals (xii) Fabrication of LT panel board with all accessories except above and complete painting. Angle iron support made out of 50 x 50 x 6MM thick (xiii) Cost of PCC, eraction incl commission etc complete(xiv) Cable entry glands and two nos earthing terminals (xv) Fabrication of LT panel board with all accessories except above and complete painting. Angle iron support made out of 50 x 50 x 6MM thick (xvi) Cost of PCC, eraction incl commission etc ,complete allasspecifiedanddirected. |
| 64 | Supply, installation, testing and commissioning of CPRI approved LT panel board, outdoor type, with front and back door openable type fitted with nuts, bolt and washers fitted with knob and hinges, floor mounted fabricated out of 3.00 mm thick MS sheet to be placed over pedestals in PCC 1:3:6 type C-1 cement concrete extending 300mm above ground level. LT panel shall be totally enclosed weather proof and verming proof with front and rear opening with IP-54 protection as per IS-8623 duly powder coated for connection, RYB, insulator complete pre-wired and cable connection with copper conductor wire upto aluminium bus bar including all incoming and outgoing cable connection with suitable size of aluminium lugs/gland complete all as specified and directed by Engr-in Charge and also comprising of the following of suitable size.(i) MCCB 100 A FP, 16 KA Adjustable thermal & Fixed magnetic setting. 1 Nos. (Incoming) (ii)MCCB 63A FP, 16 KA, Adjustable thermal & Fixed magnetic setting. 1 Nos. (Outgoing) (iii)MCB TPN 40 A, 10 KA, 440 volts:- 03 Nos (iv) MCB SPN 32 A, 10 KA -03 Nos (v) Alumimiumbus bars sleeve insulated 160 amps capacity TPN mounted on epoxy insulators1 Set (vi)Digital voltmeter 0 - 500 V range with selector switch - 01 No (vii) Digital ammeter 0 - 200 A range with selector switch and CTs - 01 No(viii)Indicators RYB - 01 Set (ix)Internal wiring of the panel board with single core copper cable PVC insulated of suitable size and control fuses. (x) Cable entry glands and two nos earthing terminals (xii) Fabrication of LT panel board with all accessories except above and complete painting. Angle iron support made out of 50 x 50 x 6MM thick. (xiii) Cost of PCC, eraction incl commission etc ,complete allasspecifiedanddirected. |
| 65 | Supply, fabricate, erect, test and commission in replacement outdoor LT Feeder pillar box totally enclosed weather and vermin proof, suitable verntilated, 440 Volts, 50 HZ, AC Supply, factory made standard design as per electrical requirements to suit power distr sys , enclosure fabricated out of 3.00 mm thick MS sheet with front and back done openable, excavation and earth work, PCC foundation etc,with hinged doors and lcoking arrangemetn , air vents, tappered roof, incoming and outgoing cable connections from bottom with compressed cable gland etcas required with and including the following, supplied fitted and connected internally complete04 Nos aluminiumbus bar of unequal size of aluminium conductor with PVC coloured heat srinkable type sleeves continous phase rating 400 Amps and neutral rating 200 Amps mounted on non cracting resin type insulators, moulded case circuit breaker Four pole 400 Amps 50 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In complete all as specified |
| 66 | Supply and fix in replacement of Timer panel, made of MS Enclosure factory made consisting Astronomical timer with max load of 12 KW with 65 A TP contactor with MCB 63 Amp TPN three phase 415 volts conforming to IS/IEC 60947-4-1, provided with protection degree IP 54 with internal wiring FRLS copper cable, in built shor-circuit-protection, class H insulation complete as as specifed and directed. with suitable size of angle iron frame and necessary PCC Wk all as specified and as directed by Engr-n-charge |
| 67 | M&L for attending day to day breakdown complaints of any nature in low tension line after receiving the complaint from complaint cell/ JE concerned and rectifying the same as soon as possible complete all as specified and directed. Note : If any major materials are used will be measured and paid separately in appropriate items above. |