| Sl. No. | Item Description |
| 1 | GENERAL SUMMARY ( PHASE-I)NOTE: Schedule ‘A’ Part - I to XI are prepriced by MES under Ser No. 2.00to 12.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-7 only. |
| 2 | Lumpsum price worked out by the contractor for “BUILDINGS / STRUCTURES ” as listed in Schedule ‘A’ Part - I , |
| 3 | Lumpsum price worked out by the tenderer for \"SITE CLEARANCE / SITE DEVELOPMENT/ EARTH WORK/ EXCAVATION\" as listed in Schedule ‘A’ Part-II |
| 4 | Lumpsum price worked out by the tenderer for \"DEMOLITION OF BUILDING\" as listed in Schedule ‘A’ Part-III |
| 5 | Lumpsum price worked out by the tenderer for \"INTERNAL ELECTRIFICATION\" as listed in Schedule ‘A’ Part-IV |
| 6 | Lumpsum price worked out by the tenderer for \"INTERNAL WATER SUPPLY \" as listed in Schedule ‘A’ Part-V |
| 7 | Lumpsum price worked out by the tenderer for \"ROAD/PATH/HARD STANDING/CULVERT \" as listed in Schedule ‘A’ Part-VI |
| 8 | Lumpsum price worked out by the tenderer for \"SEWAGE DISPOSAL \" as listed in Schedule ‘A’ Part-VII |
| 9 | Lumpsum price worked out by the tenderer for \"EXTERNAL WATER SUPPLY\" as listed in Schedule ‘A’ Part-VIII |
| 10 | Lumpsum price worked out by the tenderer for \" EXTERNAL ELECTRIFICATION\" as listed in Schedule ‘A’ Part-IX |
| 11 | Lumpsum price worked out by the tenderer for \" FIRE FIGHTING \" as listed in Schedule ‘A’ Part-X |
| 12 | Lumpsum price worked out by the tenderer for \" LIGHTENING PROTECTION\" as listed in Schedule ‘A’ Part-XI |
| 13 | SCHEDULE \"A\" PART - XIIMISCELLANEOUS ITEMSNOTE:Schedule ‘A’ Part - XII is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-7. |
| 14 | Taking down oldsub main wiring any type as specified and directed. |
| 15 | Taking down lightfittings of any type as specified and directed. |
| 16 | Taking down old UG Cable from trenchesof any size as specified and directed. |
| 17 | Taking down old DI Pipe line of size150/100 mm diafrom trenchesas specified and directed. |
| 18 | Point wiring with 1.5 sqmm FRLS PVC insulated and unsheathed copper conductor multistranded 1100 volts grade, ISI marking drawn thorugh and inculding non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marking, concaled including provn of pre fabricated galvanised module box of 2 mm thick of suitable size as required at site for fixing switches, sockets, inculding one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity, connected to earth duly complete all as specified and directed for the following: |
| 19 | (a) One lightpoint controlled by one switch |
| 20 | (b) One bell point controlled by one switch |
| 21 | (c) One fan (Ceiling/Wall/Exhaust fan) point controlled by one switch |
| 22 | (d) One 3 pin socket outlet 5 Amps socket on Independent board |
| 23 | (e) One3 pin socket outlet 15 amps socket on independent board with 2.5 sqmm FRLS PVC wire and one run of 2.5 sqmm copper cable for earth continuty. |
| 24 | (f) One 3 Pin socket outlet 5 amps socket on same board |
| 25 | (g) All as per Item No. 18.01 here-in-before but controlled by two two way switches complete all as specified and directed |
| 26 | S&F LED Security light fitting with tube minimum 30 W New generation Energy saving & environmental friendly long life versatile pressure die cast aluminium luminiare with mid power LEDs as source and HF electronic driver pre wired with 1.5 Sqmm copper conductor cable upto connector including 2 Mtr long GI Tubing Med grade 32 mm dia bend to shape fixing on wall with suitable MS brackets complete all as specified and directed. |
| 27 | M&L Submain wiring for Single phase supply with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire incl PVC rigid conduit of suitable size with acessories complete for 2 runs 6.0 Sqmm and 1 runs 6.0 Sqmm complete and making good the disturbed area all as specified and directed.Note: 3 run of 6 sqmm & one run of PVC conduit shall be measuredas single unit |
| 28 | Valve chamber of internal size 600x600x 600mm comprising of 50mm thick PCC 1:4:8type D2 (using 40mm graded stone aggregate) foundation 230mm thk brick walls in CM 1:4, 15mm thk plastering in CM 1:4 internally and externally upto 150mm below GL, 100mm thick PCC 1:2:4 type B1 (Using 20mm gradedstone aggregate) coping, 3mm thick MS sheet cover with suitable hinges and locking arrangement, painting steel surfaces with two coat of synthetic enamel paint over a coat of zinc chrome primer including necessary excavation and earthwork in any type of soil complete all as specified and directed. |
| 29 | Valve chamber of internal size 750x750x 750mm(internal dimension) as under provided with 10cm thick PCC 1:4:8 type D2 as in foundation over 15cm thick hard core, 23 cm brick wall built in CM 1:4, 15mm thick internal plaster including top of floor, externally upto 150mm below GL in CM 1:3 finish even and smooth without using extra cement, 4mm thick MS Sheet cover with 40 x 40x 6mm MS angle frame fixed in PCC 1:2:4 type B1 coping with 25 x 6mm flat iron hold fasts, hinges, handles , locking arrangement and applying 2 coat of synthetic enamel paint over a coat of red oxide primer to all steel surface andincluding necessary excavation and earthwork in any type of soil complete all as specified and dir3 coats of white wash to internal surfaceof chamber including excavation and earth work in any type of soil to a distance not execeeding 50m complete all as specified and directed. |
| 30 | Supply and lay pipe ductile Iron , S/S including specials, Class “K-7” ,150 mm (6”) dia complete all as specified and directed. |
| 31 | Supply and lay pipe ductile Iron , S/S including specials, Class “K-7” ,100 mm (4”) dia complete all as specified and directed. |
| 32 | Cutting existing pipe line,ductile Iron of size 100/150 mm dia for alterations or additions completeall as specified and as directed |
| 33 | Cutting existing steel tubing 80 mm dia for alterations or additions completeall as specified and as directed . |
| 34 | Screwing existingsteel tubing 80 mm dia for alterations or additions (or lengthening screw on pipe to form connector completeall as specified and as directed . |
| 35 | Supply, Install, Test and Commissioning ofLT Panel board made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 400 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(Bldg Panel) |
| 36 | Incoming:(a) MCCB, 200 Amps, 415V, 3 phase, 4 wire 50 cycles, 25kA, Adjustable type complete with overload protection, no-volt thermal based release - 01 NoOutgoing:(a) MCCB, 160 Amps, 415V, 3 phase, 4 wire 50 cycles, 16 kA, Adjustable type complete with overload protection, no-volt thermal based release - 01 No (DG AMF)(b)MCCB, 63 Amps, 415V,3 phase, 4pole, 16kA, Adjustable type complete with overload protection, no-volt thermal based release - 01 No (APFC panel)(c)MCCB, 32 Amps, 415V, 3 phase, 4 pole, 16kA- 5 Nos ( Ground to 4 th floor)(d)MCB,SPN,20Amps, 230V- 1No (Common area lighting)(e) Muilty function meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs (f)LED Indicating Lamps for ech phase with colour code Red Yellow Blue for R, Y and B Phases |
| 37 | Supply, Install, Test and Commissioning ofLT Panel board made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 300 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(DG Panel) |
| 38 | Incoming:(a) MCCB, 160 Amps, 415V, 3 phase, 4 wire 50 cycles, 25kA, Adjustable type complete with overload protection, no-volt thermal based release - 01 NoOutgoing:(a) MCCB, 100 Amps, 415V, 3 phase, 4 wire 50 cycles, 16 kA, Adjustable type complete with overload protection,thermal based release - 01 No (Fire fighting pumps)(b)MCCB, 63 Amps, 415V,3 phase, 4pole, 16kA, Adjustable type complete with overload protection, thermal based release - 03 Nos (Lifts panel , Cool& cold room and spare)(c)MCCB, 32 Amps, 415V, 3 phase, 4 pole, 16kA- 5 Nos ( Ground to 4 th floor)(d)MCB,SPN,20Amps, 230V- 1No (Common area lighting)(e) Muilty function meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs (f)LED Indicating Lamps for ech phase with colour code Red Yellow Blue for R, Y and B Phases |
| 39 | Supply, Install, Test and Commissioning ofLT Panel board made out of CRCA sheet 2 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 200 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(Lifts Panel) |
| 40 | Incoming:(a) MCCB, 63 Amps, 415V, 3 phase, 4 wire 50 cycles, 25 kA, Adjustable type complete with overload protection, no-volt thermal based release - 01 NoOutgoing:(a) MCCB, 32 Amps, 415V, 3 phase, 4 wire 50 cycles, 16kA, Adjustable type complete with overload protection, no-volt thermal based release - 04 Nos (for 3 Lifts and spare)(b)MCB,SPN,20Amps, 230V- 1No (Machine room lighting)(c) Muilty function meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs (d)LED Indicating Lamps for ech phase with colour code Red Yellow Blue for R, Y and B Phases |
| 41 | Supply, install, testing and commissioning of factory made APFC panel CPRI approved OEM, free standing floor mounted, dust and vermin proof Automatic Power Factor Correction [APFC] Panel of capacity of 30 KVAR with 4 steps (1 x 15 + 3 x5) Compartmentalised, indoor type, fabricated as per IEC 61921 with 2 mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces with minimum IP 43 Ingress Protection suitable for 3 Phase, 415 V & 50 Hz System with MD-XL Capacitor including suitable rated TPN, MCCB, 415 V, 25 KA rupturing capacity as incomer duly controlled by Auto and Manual option including instrumentation such asPower Factor Meter – 1 No, Digital type Ammeter of Range 0 to 200 Amps with CTs & Selector Switch – 1 No, Digital type Volt Meter of Range 0 - 500 V – 1 No, Relay, Auxiliary Contacts, CTS, Phase Indicating LED Lamps [RYB], Selector switches etc., suitable internal wiring with copper cable of suitable size, double stud hinged door, front openable with locking arrangement including interlocking with switch gears complete andpanel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level including connecting up with existing incoming and outgoing cables etc. complete all as specified and as directed. |
| 42 | Supply, fix and testingXLPE LT cable jointing kit straight througharmoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor for25 sqmm3.5 core all as specified and as directed |
| 43 | Supply, fix and testingXLPE LT cable jointing kitstraight through armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor for70 sqmm3.5 core all as specified and as directed |
| 44 | Dismantling of existing L T panel board completeand refixing in the sameincluding with PCC work all as specified and directed |
| 45 | Supply and laying (DWC)double wall corrugated pipe of pressure rating 6kg/sqcmof size 75 mm laid in trenches complete all as specified and directed |
| 46 | Cutting the road / hard standing for laying of pipes / cable in trenches and making good with PCC 1 :2 :4 Type B1complete all as specified and directed |
| 47 | M&L LT Cable route marker of size 45 Cm above the ground level and 30 cm below groundwith suitable size of PCCand distance as per side requirementall as specified and directed |
| 48 | M & L for earthing complete with galvanised steel earth plate electrode60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 32x6mm GI strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 connected to earthing test point,including 20 mm GI pipe (Medium grade) for watering and 40 mm GI pipe (Medium grade) for protection of earth strip andetc..including testing on completion ,PCC chambers in PCC1:3:6 type C1, RCC M25 type cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wiremesh ,funnel,lugs and charcoal,salt etc all as applicablecomplete all as specified and as directed by the Engineer-in-Charge |
| 49 | Supply and installation LT Electric control panel, cubical type, for out door use floor mounted made out of CRCA outer sheet of 3 mm thick and inner sheet of 2 mm thick and angle iron legs of size 50mmx50mmx5mm having front and rear open hinged doors with front openable shutters for each MCCB with spreader with fully enclosed bus bar chamber, having insulated bas bar made but of aluminium strips of rating 300 amps for 3 phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter , Ammeter,CTs and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over as coat of red oxide primer complete and nut,bolt,washers for connection of cable, including necessary PCC work of height 45 cm from ground level and white washing to the platform all as specified and equipped with the following items :-(DG panel) |
| 50 | INCOMER:I.MCCB, 4pole,200 Amps , rupturing capacity 25 KAmagnetic thermal release - 01 Nos. II. Digital Ammeter 0-300 Amps CT Operated- 01 No (L&T)III. Digital Volt Meter 0-500 Volts - 01 No (L&T)IV. LED Indicator lamp in three colour RYB - 03 Nos (L&T)OUTGOING:I. MCCB, 4pole,100 Amps , rupturing capacity 16 KAmagnetic thermal release - 02 Nos. II.MCCB, 4pole,63 Amps , rupturing capacity 16 KA magnetic thermal release- 02 Nos. |
| 51 | Supply and fixing Air release valve single air outlets conforming to IS 14845 of size 25 mm dia bore fixed on the top of wet riser complete all as specified |
| 52 | Supply and fixing Star delta fully automatic starter for 15 HP pumps complete all as specified and directed by Engr in Charge |
| 53 | Supply and fixng perforated GIcable tray of size100 X 50 X 1.6mm thickness including mounting accessories and paint two coat of primer over one coat of red oxide as required at site and all as directed |
| 54 | Material and labour for civil works PCC plastering all as required at site and all as directed |
| 55 | Material and labour for MS Channel structural steel supports made from the walls and from the floorshall be hitek supports fabricated out of MS channel sections of 75mm X 50mm for fixing of ms pipe in wall /roof floor etc all as specified and directed. |
| 56 | Supply and fixing addressable Manual call pointall as per IS standard complete all as specified and directed. |
| 57 | Supply and fixing24 v electronic hooter all as per relevant ISstandard complete all as specified and directed. |
| 58 | Material and labour for2 runx 1.5 sqmm unarmoured FRLS cable through steel conduit heavy duty including mounting all as directed |
| 59 | S&F 6kg fire extinguisher dry chemical powder (ABC) Type complete all as specified and directed. |
| 60 | S&F 4.5kg fire extinguisher Co2 type complete all as specified and directed. |
| 61 | S&F 9kg/litre fire extinguisher water stored pressure type complete all as specified and directed. |
| 62 | S&F fire buckets 3 Nos with stand complete all as specified and directed. |
| 63 | S&F Mechanical foam fire extinguisher 9 litre capacity complete all as specified and directed. |
| 64 | M & L for Cutting existing MS tubing for alterations or additions of any size and welding with given MS tubing alla s specified and directed. |
| 65 | Supplied & fixed rigid non-metallic PVC conduitheavy gradeISI marked exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., External dia in 25 mm, including One run of2mm dia GI wire along with one run of PVC conduitcomplete all as specified and as directed.Note : One run of GI wire and one run of PVC conduit shall be measured as one unit. |
| 66 | M&L for junction boxes (1 to 4 way) external dia 25mm complete ll as specified and as directed. |
| 67 | Supply and fix TV sockets outletcomplete all as specified and as directed |
| 68 | Supply and fix Tele Jack single with shutterRJ 11with complete all as specified and as directed |
| 69 | Supply, install, test and commissioning of accoustic proof AMF type diesel engine driven generating set fully wired, 415V, +5%, AC 3 phase, 4 wire, 50 Hz having capacity 100 KVA continous rating power factor 0.8 (lagging), connecting as per IE rules and mouted on a common base plate with anti vibration padrecommended by the manufacturer all as specified and directed., The DG set shall comprise of following :- .The diesel engine will comprise of following:- (A) Diesel Engine - The engine should be six cylinder,liquid cooled, turbocharged with after cooler, developing 127 BHP @ 1500 RPM. 6SL1500TA G3 is inline, electric start, compression ignition, 4 stroke, designed to run continuously at 1500 RPM confirming to IS 8528 ISO-8528. BS 5514 strandard. Diesel Engine will comply with present CPCB -IV norms. Make - CUMMINS / KIRLOSKAR/ CROMPTON GREAVES |
| 70 | ITEM NO. 58 Con…1.Dry type air cleaner2.Exhaust silencer suitable for canopy3.Expansion bellow4.lube oil coller5.Lube oil filter6.Fuel filter7.Radiator with pusher type fan and mounting8.In-line mono block fuel injection pump9.Electronic governor and fuel feed pump10.Flywheel with starter ring and bell housing suitable for close coupling11.Electric starter motor 12Volt12.Battery charging alternator 13.Microprocessor based KG745 controller fixed in power panel14.Protection system for Low lube oil pressure, high water temperature(B) Alternator, The alternator shall be designed for an output of 100 KVA suitable for continuous operation rated at 1500 rpm 415 V, 0.8 PF, 50Hz, 3Ph in SPDP enclosure, self exicted & self- regulated, Brush less, floor mounted with Ball or Bearing on end shields. The alternator conforms to IS : 4722, BS EN 60034-1 & will be suitable for tropical condition. Make;- KIRLOSKAR/ ALSTOM/STAMFORD/JYOTI/ CROMPTON GREAVES. |
| 71 | ITEM NO. 58 Con… (C) Electric system : The electric system of the startermotor and charging alternator shall have the following components:- (i) Charging alternator 12V, DC(ii) Voltage regulator built in type IC regulated (iii) Starter motor 12 volts DC (iv)Battery 12 volts DC and capacity 120 AH 02 nos with one set of connecting leads of 70 Sqmm size copper cable. (D) Fuel tank (Service tank) : The fuel tank shall be mild steel suitable to hold 290 ltrs capacity and shall be inlducing fuel level indicator duly marked to read 25%, 50%, 75%,100% per division fuel line from tank to engine arrangement for fuel filling fueland digital display and drain out facility etc. compelte all as specified.(E)AMF Control Panel : Automatic mains failure (AMF) control panel shall be able to start up the DG set and transfer the load on to the DG set on main failure without requiring any human intervention .Similarly on restoration of Main supplyit shall be able to transfer the DG set automatically alognwith provision of by pass arrangements of main supply.The AMF panel shall be with in enclosure having IP-53 degree of protection conforming to IS:13947 (Part-I) 1993 fabricated from minimum 1.6mm thick CRCA sheet steel duly pre treated aesthetically finished and shall be dust and vermin proof.The AMF panelshall have the following accesseories:- (a)Micro precessor based relay wiht composite meter for digital display of (i) Generator voltage/AC main voltage (ii) Generator current (iii)Power factor (iv) frequency(v) Energy (KWH) (vi)Three attempt engine start/ Engine Cranking relay (vii) On delay time for load change over(viii) On delay time for engine shut off (ix) Fuel level reading in ltr (b) Mode selector for setting the panel on any one position such as \"Off\" or \"Auto\" or \"Manual\" or \"Test\" (c)Engine ON-OFF switch (push button type) (d) MCCB of capacityof 160 Amp FP suitable to alternator 415 volts 25 KA-1 No |
| 72 | ITEM NO. 58 Con…(e) Aluminium Bus bar (one number for each phase and neutral and earthing terminal) or adequate rating duly colour with heat shrinkable PVC sleeves . (f) Two contractors of suitable rating (one for DG set & one for AC mains) with over load relay. (g) Under voltage relay for mains(h) Battery charger complete with voltage regulator, float or boost selector switch On-OFF switch, voltmeter and ammeter for charging the battery frommains.This will be in addtion to the battery charging alternator fitted on the engine. (j) Instrument and control panel.(k)Five numbers indicating lamps to indicate \"Mains ON\", \"Load on mains\", DG set running \"Load on DG set\" and \"Battery ON\" (l) Audio Visual alarm for \"Low lubricating oil pressure\", \"High water temperature\", \"Start failure\" and DG set over load\".(m) Any other switch, instrument, relay or contactor etc. essential for smooth and trouble free functioning of DG set with AMF panel. |
| 73 | Supply and installation LT Electric control panel, cubical type, for out door use floor mounted made out of CRCA outer sheet of 3 mm thick and inner sheet of 2 mm thick and angle iron legs of size 50mmx50mmx5mm having front and rear open hinged doors with front openable shutters for each MCCB with spreader with fully enclosed bus bar chamber, having insulated bas bar made but of aluminium strips of rating 300 amps for 3 phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter , Ammeter,CTs and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over as coat of red oxide primer complete and nut,bolt,washers for connection of cable, including necessary PCC work of height 45 cm from ground level and white washing to the platform all as specified and equipped with the following items :- |
| 74 | INCOMER:I.MCCB, 4pole,200 Amps , rupturing capacity 25 KAmagnetic thermal release - 01 Nos. II. Digital Ammeter 0-300 Amps CT Operated- 01 No (L&T)III. Digital Volt Meter 0-500 Volts - 01 No (L&T)IV. LED Indicator lamp in three colour RYB - 03 Nos (L&T)OUTGOING:I. MCCB, 4pole,100 Amps , rupturing capacity 16 KAmagnetic thermal release - 02 Nos. II.MCCB, 4pole,63 Amps , rupturing capacity 16 KA magnetic thermal release- 02 Nos. |
| 75 | Design, Supply, Install, Testing and Commisioning of Passenger Lift, As per state lift rules with capacity of 13 Nos. passangers, Speed 1.5 metre/sec, Lift with single speed motor 415 Volts, 3 Phase, AC 50Hz supply conforming to IS-14665, suitable to serve G + 3 upper floors with AC Variable Voltage and Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (Electric motor driven mechanism), sliding stainless steel doors, Automatic Rescue Device(ARD) System (with+/-5mm with suitable dry maintenance free battery, automatic power operated Centre Opening & Sliding stainless door of 16 gauge with 3D infrared sensor in full height of door and built-in announcing system without hand set (03 Nos, One each in car, machine room and Near Ground floor landing door) complete all as specifiedinclnecessary joists for mouting machine in machine room and all civil works required with erecion of lift incl auto fan, LED lights, emergency lights all as specified .The lift shall be provided with and including the following:- (a)alarm speaker for alarm system to be fixed),stop button in car with rechargeable arrangement for battery, (b) four sleek circular LED lights fitting in false ceiling, (c) overload warning indicator both audio and visual type with tripping system having relay etc. (d) set of three nos limit switches at the bottom and top most position of lift.(e) display indicating panel, power control cables (f) testing of govt approved lift inspector (h) Marking on lift\"s pit and lift room (i) Mirror of 6mm thickness of suitable size on one wall inside the car |
| 76 | (k)Battery operated emergency light (LED ceiling fitting), alarm (speaker for emergency alarm system to be fixed on all the floors) and stop button in car with rechargeable arrangement for battery(l) Aluminium chequered plate (3mm thick) as flooring (m) Car size shall be conformily with IS-3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail (n)Front door, operations with a minimum time of 10 seconds and upto a maximum timeof 30 seconds. (o) Hand rail (o) Specification plate (p) Wire rope/belt as per specificationof adequate size as per relevant IS and as per manufacturer specification(q) Suitable earthing pit earthing of lift as per IS and as required technically (r) One sleek circular PVC heavy duty fan in false ceiling.(s)Fire man switch(t)Automatic rescue device during power failure with capacity of battery designed for 45 minutes including manual operation provision (u) Other standard fixtures and fittings like guide rails, sheaves, counter weight with guard, buffers, gears, brakes, control panel, motor, locks, governor,car operational panel, power control and trailing cables complete. Make OTIS/JONHSON/PREMIERNote :-The rate quoted shall beIncluding the rate for comperhensive maintenanceperiod for two year after completion of the work. |
| 77 | Note(i) Comprehensive maintenance consists of preventive and breakdown services including replacment of minor consumables like topping of gear oils/grease/door rollers/relays/door belts/gate lock contacts and any hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes the above(ii)Preventive maintaince consists of carrying out routine check by skilled personnel as specified in Particular specifications and as recommended by Engineer-in-Charge and lubricating to all moving parts,topping up of oils as per Lubrication chart. (iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical and control circuits and mechanical components of the lift that may occur during the operation. (iv) Fortnightly,quarterly maintaince registeres shall be maintained and signed by site engineer and contractor.(v) Load testing shall be arranged by the contractor to the Lift for whose repairs were carried out as and when directed by Engr-in-charge. |
| 78 | (vi) All maintenance work shall be carried out by well qualified tradesman and supervisor of OEM.(vii)The quoted rate shall be deemed to be included the above aspects and for consumables such as timely toping up oils, acrylic covers, fuses, grease, waste cotton, stationary and other miscellaneous items and all other major and minor spare parts.(viii)One qualified diploma Engineer shall be employed whenever required along with one helper having sound knowledge and well experience in maintenance of lift. All the staff employed for maintenance will be reported to AGE E/M office daily will give day to day progress duly entered in the registers. (ix)The tenderer shall submit MoU from the original manufacturer of the lift for comprehensive maintenance to undertake comprehensive maintenance during and after defects liabilities period directly or through their nearest authorised/accredited agencies service personnel.The MoU shall be submitted at least 06 months prior to issue of completion certificate of main contract as per Work order No.1(x) The quoted rate deemed to included yearly testing of lifts from authorised lift inspector. |
| 79 | M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6 mm dia galvanised iron or steel strip, complete all as specified and as directed by the Engineer-in-Charge |
| 80 | Design, Supply, Install, Testing and Commisioning of Passenger Lift, with capacity of 8 Nos. passangers, Speed 1.5 metre/sec, Lift with single speed motor 415 Volts, 3 Phase, AC 50Hz supply conforming to IS-14665, suitable to serve G + 3 upper floors with AC Variable Voltage and Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (Electric motor driven mechanism), sliding stainless steel doors, Automatic Rescue Device(ARD) System (with+/-5mm with suitable dry maintenance free battery, automatic power operated Centre Opening & Sliding stainless door of 16 gauge with 3D infrared sensor in full height of door and built-in announcing system without hand set (03 Nos, One each in car, machine room and Near Ground floor landing door) complete all as specifiedinclnecessary joists for mouting machine in machine room and all civil works required with erecion of lift incl auto fan, LED lights, emergency lights all as specified .The lift shall be provided with and including the following:- (a)alarm speaker for alarm system to be fixed),stop button in car with rechargeable arrangement for battery, (b) four sleek circular LED lights fitting in false ceiling, (c) overload warning indicator both audio and visual type with tripping system having relay etc. (d) set of three nos limit switches at the bottom and top most position of lift.(e) display indicating panel, power control cables (f) testing of govt approved lift inspector (h) Marking on lift\"s pit and lift room (i) Mirror of 6mm thickness of suitable size on one wall inside the car |
| 81 | (k)Battery operated emergency light (LED ceiling fitting), alarm (speaker for emergency alarm system to be fixed on all the floors) and stop button in car with rechargeable arrangement for battery(l) Aluminium chequered plate (3mm thick) as flooring (m) Car size shall be conformily with IS-3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail (n)Front door, operations with a minimum time of 10 seconds and upto a maximum timeof 30 seconds. (o) Hand rail (o) Specification plate (p) Wire rope of adequate size as per relevant IS and as per manufacturer specification(q) Suitable earthing pit earthing of lift as per IS and as required technically (r) One sleek circular PVC heavy duty fan in false ceiling.(s)Fire man switch(t)Automatic rescue device during power failure with capacity of battery designed for 45 minutes including manual operation provision (u) Other standard fixtures and fittings like guide rails, sheaves, counter weight with guard, buffers, gears, brakes, control panel, motor, locks, governor,car operational panel, power control and trailing cables complete. Note :-The rate quoted shall beIncluding the rate for comperhensive maintenanceperiod for one year after completion of the work. |
| 82 | Note(i) Comprehensive maintenance consists of preventive and breakdown services including replacment of minor consumables like topping of gear oils/grease/door rollers/relays/door belts/gate lock contacts and any hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes the above(ii)Preventive maintaince consists of carrying out routine check by skilled personnel as specified in Particular specifications and as recommended by Engineer-in-Charge and lubricating to all moving parts,topping up of oils as per Lubrication chart. (iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical and control circuits and mechanical components of the lift that may occur during the operation. (iv) Fortnightly,quarterly maintaince registeres shall be maintained and signed by site engineer and contractor.(v) Load testing shall be arranged by the contractor to the Lift for whose repairs were carried out as and when directed by Engr-in-charge. |
| 83 | (vi) (vi) All maintenance work shall be carried out by well qualified tradesman and supervisor of OEM.(vii)The quoted rate shall be deemed to be included the above aspects and for consumables such as timely toping up oils, acrylic covers, fuses, grease, waste cotton, stationary and other miscellaneous items and all other major and minor spare parts.(viii)One qualified diploma Engineer shall be employed whenever required along with one helper having sound knowledge and well experience in maintenance of lift. All the staff employed for maintenance will be reported to AGE E/M office daily will give day to day progress duly entered in the registers. (ix)The tenderer shall submit MoU from the original manufacturer of the lift for comprehensive maintenance to undertake comprehensive maintenance during and after defects liabilities period directly or through their nearest authorised/accredited agencies service personnel.The MoU shall be submitted at least 06 months prior to issue of completion certificate of main contract as per Work order No.1(x) The quoted rate deemed to included yearly testing of lifts from authorised lift inspector. |
| 84 | Supply ,install and testingsplit Air conditioner inverter type 1.5 TR ,5 Star rating with EER 3.2 capacity with indoor and outdoor units (copper condenser coil, copper cooling coil and evaporator including required length of copper tubing and cables for connecting indoor and outdoor units ) complete with cordless remote control unit , with inverter rotary compressor with inbuilt air ioniser and plazma filter for better indoor air quality complete ,completeall as specified and as directed. Make :VOLTAS/ BLUESTAR/CARRIER/ O GENERAL/HITACHI.Note :Rate quoted is inclusive of the following:-(i) Drilling hole on the brick wallto facilitate routing of Copper pipe, drain pipe and cable from indoor unit to outdoor unit.(ii) Sealing the hole from outside ,after installation, with white cement.(iii) Pressure testing , cooling performance check and product demonstation. (iv) cable for connecting indoor and outdoor unit upto 3.00 Mtr each.(v) Material and labour for fixing Remote stand in wall and outdoor unit stand.(vi) Copper pipe,upto 3.00 Mtr each. |
| 85 | Supply and fixvoltage stablizerfor automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 230V with accuracy of ± 2.5% and of capacity 4.0 KVA complete all as specified and directed. |
| 86 | Supply and install complete COLD room for ambient tempreture renge of room 04-40 degree of size 7.6x5.2x2.69 mtrs 415 V 3 Phase 50 Hz , pre fabricated modular PUF panels with cyclopentane blowing agent Eco friendly panels incl internalelecrtification with suitable floor insulation 60 mm thickwith lamination of panels wall and ceilingSS/SS.and floor finish shall be 60 mm with marine plywood and aluminium chequer sheet and door flush type with 34\"x78\"clear opening with anti condensation door heater ,pad lock system posi seal closure ,humen safety release knob .The capacity of refrigerent 40000 BTUH/Hrs x 2 nos(1W+1S)AND RECIP Harmetic type compressor and digital tempreture indicator cum controller shall be provided all as specified and directed by Engr in charge including necessary civil works, ducting work and extra piping required.Make: BLUE STAR/HITACHI /VOLTAS |
| 87 | Supply and install complete COOL/Freezer room for ambient tempreture renge of room -15 TO +40degree of size 4.4x4.4x2.69 mtrs 415 V 3 Phase 50 Hz , pre fabricated modular PUF panels with cyclopentane blowing agent Eco friendly panels incl internalelecrtification with suitable floor insulation 60 mm thickwith lamination of panels wall and ceilingSS/SS. The floor panel with shall be 100 mm marine plywood and aluminium checker sheetand door flush type with 34\"x78\"clear opening with anti condensation door heater ,pad lock system posi seal closure ,humen safety release knobThe capacity of refrigerent 18000 BTUH/Hrs x 02 nos (1w+1s)AND Scroll type compressor and digital tempreture indicator cum controller shall be provided and all as specified and directed by Engr in charge including necessary civil works ducting work and extra piping required.Make: BLUE STAR/HITACHI /VOLTAS |
| 88 | Supply and fixAviation obstruction light LED type filament-less bulb with 10 Watt bulb complete including standard fixing arrangements all as specified and as directed |
| 89 | M&L.Cable PVC insulated PVC sheathed LT 1100 V grade with copper conductor of size 3 core 2.5 sqmm multi stranded conductor laid in ground fixed to wall roof etc with suitable calmps spacers bolts nuts etc all as spcified and as directed |
| 90 | M&L ForLoop in loop out box of FRP made with IP 65 protection of thermoplasic circuit junction boxes of size 205 x 255 x 112 mmfor cable entry and exit, Combi climate Cable Glands of IP 66/ IP 67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB SP 6 Amps, 10 kA, C Curve Overload and Short Circuit protection, terminals as PVC connector heavy duty 32Amps,4 wayfor cable with necessary fixing arrangemets and with cable glands, etc all as specified and directed. |
| 91 | Supply and fix time switches 250 V singlePhase of 20 Amp rating with contactorFitted inside steel enclosureall as specified and directed. |
| 92 | Sch A Part-XIII PHASE-II (M&O OF 13 & 8 PASSENGERS LIFT AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 60 & 62FIRST YEAR DURING DEFECT LIABILTY PERIOD.) |
| 93 | Mainning & Operation of electrically operated lifts by providing services of one lift operator (semi skilled) Metric / SSC qualified with 2 to 3 years of relevant experience for main building comprising of one 8 & Two 13 passenger lifts for main buildings in two shift for 12 month including sundays and holidays in two shifts a day including taking care of form any pilferage, theft of damage etc to ensure smooth and trouble free operation of lifts to the entire satisfaction of user during first year of Defect liability period complete all as specified and as directed. |
| 94 | Sch A Part-XIV PHASE-III (M&O OF 13 & 8 PASSENGERS LIFT AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 60 & 62SECOND YEAR DURING DEFECT LIABILTY PERIOD.) |
| 95 | Mainning & Operation of electrically operated lifts by providing services of one lift operator (semi skilled) Metric / SSC qualified with 2 to 3 years of relevant experience for main building comprising of one 8 & Two 13 passenger lifts for main buildings in two shift for 12 month including sundays and holidays in two shifts a day including taking care of form any pilferage, theft of damage etc to ensure smooth and trouble free operation of lifts to the entire satisfaction of user during second year of Defect liability period complete all as specified and as directed. |
| 96 | Note For SL No: 71 to 72.01 (i) The lift shall be operated daily in two shifts as afirected by the Engineer-in-Charge.(ii)The timings for two shifts of 8 hours each daily i.e. First shift be from 0630 hours to 1430 hours and second shift shall be from 1430 hours to 2230 hrs.(iii)In case of non function of passenger lift, the goods lift installed in the same building shall be operated as directed.(iv)The work shall be suprevised by adequately qualified supervisor with relevant experience of minimum 2 to 3 years items under BOQ shall be deemed to be including the same.(v)The unit rate is deemed to include for maintaining log books, record of repair / replacement of perished / underviceable, minor adjustment, minor repairs of all accessories, cleaning / up keeping of lift and surrounding area as directed by the Engineer-in-Charge.(vi) One emergency light and necessary tool shall be available in a tool box with the operator in the shifts for smooth functioning of lifts.(vii)Conveyance and communication system like mobile phone etc. shall be provided by the bidders / Service providers to all lift attendants / Supervisors.(viii)The Bidders shall ensure housekeeping, environmental cleanliness of area all round the lift and the area shall be kept absolutely neat and clean. The lift attendant shall clean the lift car cabin, all landing floors and tiles all round lift doors with necessary cleaning material such as cotton cloth and cleaning solution etc. |
| 97 | NOTE for SL No: 71 to 72.01 Conte...(ix) The Bidders shall abide by the latest labour rules and minimum wages Act. Wages paid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. The Biddrs shall also insure the workmen employed on the job. (x) The Biddrs is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess etc, as applicable and shall be deemed to be included for the same.(xi)Dress Code :The bidders shall provide the workmen with dark blue colour uniform (formal pant & shirt) with labels showing / printed i.e. \" Name of the firm and designation\" on front and on the back of the T-shirt along protective clothing /gear. The bidders shall also provide shoes to the workers and he persons shall not be allowed to enter the work site without wearing shoes.(xii)Insurance : The Bidders shall be responsible for all Accidents / Injuries hapenning to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward on account of any mishanding / worng operation / lack of knowledge of safety precautions or on account of any circumstances beyound his / their control, the bidders shall be solely responsible for setting all claims of copensation to the deceased falling which department will have a right to recover any sum indicated / claimed by labour commissioner / court authorities. No claim whats over will be entertained in this regard. No compensation is enable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. |
| 98 | Sch A Part-XV PHASE-IV (FIRST YEAR COMPREHENSIVE MAINTENANCE & M&OOF 13 & 8 PASSENGERS LIFT AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 60 & 62AFTER EXPIRY OF DEFECT LIABILTY PERIOD.) |
| 99 | Comprehensive maintenance of Electrically Operated 13 passenger lifts (02 No)to serve G+3 upper floors all as mentioned vide SI No. 60 of BOQ during 1st year after expiry of defects liability period complete all as specified and directed |
| 100 | Comprehensive maintenance of Electrically Operated 8 passenger lifts (01 No)to serve G+3 upper floors all as mentioned vide SI No. 62 of BOQ during 1st year after expiry of defects liability period complete all as specified and directed |
| 101 | Mainning & Operation of electrically operated lifts by providing services of one lift operator (semi skilled) Metric / SSC qualified with 2 to 3 years of relevant experience for main building comprising of one 8 & Two 13 passenger lifts for main buildings in two shift for 12 month including sundays and holidays in two shifts a day including taking care of form any pilferage, theft of damage etc to ensure smooth and trouble free operation of lifts to the entire satisfaction of user first year after expiry of Defect liability period complete all as specified and as directed. |
| 102 | Sch A Part-XVI PHASE-V (SECOND YEAR COMPREHENSIVE MAINTENANCE & M&O OF 13 & 8 PASSENGERS LIFT AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 60 & 62 AFTER EXPIRY OF DEFECT LIABILTY PERIOD.) |
| 103 | Comprehensive maintenance of Electrically Operated 13 passenger lifts (02 No) to serve G+3 upper floors all as mentioned vide SI No. 60 of BOQ during 2nd year after expiry of defects liability periodand After completion of first year Comprehensive Maintenance.complete all as specified and directed |
| 104 | Comprehensive maintenance of Electrically Operated8 passenger lifts (01 No) to serve G+3 upper floors all as mentioned vide SI No. 62 of BOQ during 2nd year after expiry of defects liability periodand After completion of first year Comprehensive Maintenance.complete all as specified and directed |
| 105 | Mainning & Operation of electrically operated lifts by providing services of one lift operator (semi skilled) Metric / SSC qualified with 2 to 3 years of relevant experience for main building comprising of one 8 & Two 13 passenger lifts for main buildings in two shift for 12 month including sundays and holidays in two shifts a day including taking care of form any pilferage, theft of damage etc to ensure smooth and trouble free operation of lifts to the entire satisfaction of user second year after expiry of Defect liability period complete all as specified and as directed. |
| 106 | Sch A Part-XVII PHASE-VI (THIRD YEAR COMPREHENSIVE MAINTENANCE & M&O OF 13 & 8 PASSENGERS LIFT AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 60 & 62AFTER EXPIRY OF DEFECT LIABILTY PERIOD.) |
| 107 | Comprehensive maintenance of Electrically Operated 13 passenger lifts (02 No) to serve G+3 upper floors all as mentioned vide SI No. 60 of BOQ during 3rd year after expiry of defects liability periodand After completion of second year Comprehensive Maintenance all as specified and directed |
| 108 | Comprehensive maintenance of Electrically Operated 8 passenger lifts (01 No)to serve G+3 upper floors all as mentioned vide SI No. 62 of BOQ during 3rd year after expiry of defects liability periodand After completion of second year Comprehensive Maintenance all as specified and directed |
| 109 | Mainning & Operation of electrically operated lifts by providing services of one lift operator (semi skilled) Metric / SSC qualified with 2 to 3 years of relevant experience for main building comprising of one 8 & Two 13 passenger lifts for main buildings in two shift for 12 month including sundays and holidays in two shifts a day including taking care of form any pilferage, theft of damage etc to ensure smooth and trouble free operation of lifts to the entire satisfaction of user third year after expiry of Defect liability period complete all as specified and as directed. |
| 110 | Note for SL No: 73.01,73.02,74.01,74.02,75.01 & 75.02:-(i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of Oils/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes for the above Lifts.(ii) Preventive maintenance consists of carrying out routine check by skilled personnel as specified in Particular specifications and as directed by Engineer-in-Charge and lubricating to all moving parts, topping parts, topping up of oils as per Lubrication Chart including Material and labour for all consumable and major/minor spare parts.(iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labour for all minor & major spare parts and consumables of the lift that may occur during the operation.(iv) Fortnightly, quarterly maintenance registers shall be maintained and signed by the site engineer and contractor.(v) Load testing shall be arranged by the contractor to the Lift for which repairs were carried out as and when directed by Engr -in-Charge. |
| 111 | NOTE for SL No: 73.01,73.02,74.01,74.02,75.01 & 75.02 Conte...(vi) All maintenance works shall be carried out by well qualified tradesmen and supervisor of OEM.(vii) The quoted rate shall be deemed to be included the above aspect and for consumables such as timely toping up oils, acrylic covers, fuses, grease, waste cotton, stationery and other miscellaneous items and all minor & major spare parts. (viii) One qualified diploma Engineer shall be employed whenever required along with one helper having sound knowledge and well experience in maintenance of lift. All the staff employed for maintenance will be reported to AGE E/Moffice and will give progress duly entered in the registers.(ix) The tenderer shall submit MoU from the original manufacturer of the lift for comprehensive maintenance to undertake comprehensive maintenance during and after Defects Liability Period directly or through their nearest authorized/accredited agencies service personel. The MoU shall besubmitted at least 06 monthsprior to issue of completion certificate of main contract as per Work Order No 1. (x) The quoted rate deemed to included yearly testing of lifts from authorised lift inspector |
| 112 | Note for SL No: 73.03,74.03 & 75.03:-(i) The lift shall be operated daily in two shifts as afirected by the Engineer-in-Charge.(ii)The timings for two shifts of 8 hours each daily i.e. First shift be from 0630 hours to 1430 hours and second shift shall be from 1430 hours to 2230 hrs.(iii)In case of non function of passenger lift, the goods lift installed in the same building shall be operated as directed.(iv)The work shall be suprevised by adequately qualified supervisor with relevant experience of minimum 2 to 3 years items under BOQ shall be deemed to be including the same.(v)The unit rate is deemed to include for maintaining log books, record of repair / replacement of perished / underviceable, minor adjustment, minor repairs of all accessories, cleaning / up keeping of lift and surrounding area as directed by the Engineer-in-Charge.(vi) One emergency light and necessary tool shall be available in a tool box with the operator in the shifts for smooth functioning of lifts.(vii)Conveyance and communication system like mobile phone etc. shall be provided by the bidders / Service providers to all lift attendants / Supervisors.(viii)The Bidders shall ensure housekeeping, environmental cleanliness of area all round the lift and the area shall be kept absolutely neat and clean. The lift attendant shall clean the lift car cabin, all landing floors and tiles all round lift doors with necessary cleaning material such as cotton cloth and cleaning solution etc. |
| 113 | Note for SL No: 73.03,74.03 & 75.03 Conte...:-(ix) The Bidders shall abide by the latest labour rules and minimum wages Act. Wages paid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. The Biddrs shall also insure the workmen employed on the job. (x) The Biddrs is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess etc, as applicable and shall be deemed to be included for the same.(xi)Dress Code :The bidders shall provide the workmen with dark blue colour uniform (formal pant & shirt) with labels showing / printed i.e. \" Name of the firm and designation\" on front and on the back of the T-shirt along protective clothing /gear. The bidders shall also provide shoes to the workers and he persons shall not be allowed to enter the work site without wearing shoes.(xii)Insurance : The Bidders shall be responsible for all Accidents / Injuries hapenning to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward on account of any mishanding / worng operation / lack of knowledge of safety precautions or on account of any circumstances beyound his / their control, the bidders shall be solely responsible for setting all claims of copensation to the deceased falling which department will have a right to recover any sum indicated / claimed by labour commissioner / court authorities. No claim whats over will be entertained in this regard. No compensation is enable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. |
| 114 | Schedule of credit amount brought back from Ser Page No. 86- Rs. 52,862.00 will be deducted from the above quoted amount to derive the contract sum.SIGNATURE OF CONTRACTOR |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail