Tender For Construction Of The Astronomical Pavilion - HIGH MAST SHAFT Supply & fixing of 12.5 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 3 mm. Top dia minium 150 mm, Bottom dia 310 mm base plate 25 mm thick suitable for wind/SOR 2018 (E-M)- 6.651 3 Supply & erection of overhead line with G.I. wire no. 8 to 4 SWG on poles/serivce bracket including binding etc. complete in all respect./SOR 2018 (E-M)- 6.628 4 Wiring of Submains with Aluminium cable using existing steel conduit, S/W of submain with two Nos. of 2.5 Sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material Labour and T&P required for proper completion of the work as directed at site by Engineer In Charge./SOR 2018 (E-M)- 2.11.289 5 Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect., 40 A TPN/SOR 2018 (E-M)- 8.807.(f) (ii) 6 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 10 sq. mm 2 core/SOR 2018 (E-M)- 5.501.(b) 7 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 35 sq. mm 3-1/2 core/SOR 2018 (E-M)- 5.501.(k) 8 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 70 sq. mm 3-1/2 core/SOR 2018 (E-M)- 5.501.(m) 9 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 10 sq. mm/SOR 2018 (E-M) (Labour Rate)- 5.504.(c) 10 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 25 sq. mm/SOR 2018 (E-M) (Labour Rate)- 5.504.(e) 11 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 50 sq. mm/SOR 2018 (E-M) (Labour Rate)- 5.504.(g) 12 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 16 sq. mm/SOR 2018 (E-M) (Labour Rate)- 5.504.(d) 13 S/B of earth rod 20mm dia into 2.5mtr long including G.I. wire 7/16 SWG to connect earth rod to earth clamp on pole 3.00 mtr long steel conduit to carry earth wire along the pole. For singel support ANNEXURE 6 - SL NO. 17/- DSR 2022 (E/M)-251 14 S/F of 6 Amp to 32 Amp. SPMCB (10KA) C curve complete in all respect as per direction of Engineer-in-charge. SI No. 1002/18. CAT-A./- DSR 2018 (E/M)-1002 15 ( Incoming 200 Amp. TPN-1 No Outgoing 100 Amp. TNP-2 Nos. Cat. B. Cubicle Type PWD SI No : 802 (a) Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B and C only. ( Incoming 200 Amp. TPN-1 No Outgoing 100 Amp. TNP-2 Nos. Cat. B. Cubicle Type PWD SI No : 802 (a)/- PWD SI No : 802 (a) 16 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PWD SI No :725 (A)/- U.P. P.W.D., & C.P.R.I. Certified. PWD SI No :725 (A) 17 Supply and Laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) DWC HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. 33.01 (Jal Nigam Varanasi SOR) 63mm dia HDPE Pipe PN-6: ClassPE-100/- 33.01 (Jal Nigam Varanasi SOR). 18 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required., Group A/DSR 2022 E-M- 1.1.1 19 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required., 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire/DSR 2022 E-M- 1.7.1 20 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required., 2 X 2.5 sq. mm + 1X2.5 sq. mm earth wire/DSR 2022 E-M- 1.7.2 21 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required., 2 X 4 sq. mm + 1 X 4 sq. mm earth wire/DSR 2022 E-M- 1.7.3 22 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required., 2 X 16 sq. mm + 1 X 6 sq. mm earth wire/DSR 2022 E-M- 1.7.6 23 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required./DSR 2022 E-M- 1.19 24 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/PVC conduit as required., 1 Pair/DSR 2022 E-M- 1.18.1 25 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings)./DSR 2022 E-M- 1.56 26 Supplying & fixing suitable size Gl box with modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required./DSR 2022 E-M- 1.57 27 Supplying and fixing PVC batten/ angle holder including connections etc. as required./DSR 2022 E-M- 1.58 28 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., 5/6 A switch/DSR 2022 E-M- 1.24.1 29 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., 2 way 5/6 A switch/DSR 2022 E-M- 1.24.2 30 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., Telephone socket outlet/DSR 2022 E-M- 1.24.6 31 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., TV antenna socket outlet/DSR 2022 E-M- 1.24.7 32 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., Bell push/DSR 2022 E-M- 1.24.8 33 Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required., 1 or 2 Module (75mmX75mm)/DSR 2022 E-M- 1.27.1 34 Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required., 3 Module (100mmX75mm)/DSR 2022 E-M- 1.27.2 35 Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required., 4 Module (125mmX75mm)/DSR 2022 E-M- 1.27.3 36 Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required., 6 Module (200mmX75mm)/DSR 2022 E-M- 1.27.4 37 Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required., 8 Module (125mmX125mm)/DSR 2022 E-M- 1.27.5 38 Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required., 12 Module (200mmX150mm)/DSR 2022 E-M- 1.27.6 39 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required., 1 or 2 Module/DSR 2022 E-M- 1.28.1 40 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required., 3 Module/DSR 2022 E-M- 1.28.2 41 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required., 4 Module/DSR 2022 E-M- 1.28.3 42 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required., 6 Module/DSR 2022 E-M- 1.28.4 43 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required., 8 Module/DSR 2022 E-M- 1.28.5 44 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required., 12 Module/DSR 2022 E-M- 1.28.6 45 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required., 20 mm/DSR 2022 E-M- 1.21.1 46 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required., 32 mm/DSR 2022 E-M- 1.21.3 47 CEILING FANS Supply of Ceiling Fans with fan motor of A.C Permanent insulation, capacitor rating conforming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltage 220/240 volts, 50Hz, 1-ph AC. The fan assembly should consist of down rod blades, shackle canopies etc and with double ball bearing system., BEE 5 Star rated - 1200mm sweep/SOR 2018 (E-M)- 15.1501.(i) 48 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required./DSR 2022 E-M- 1.26 49 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required./DSR 2022 E-M- 1.33 50 Supplying and fixing call bell/ buzzer suitable for single phase, V, complete as required./DSR 2022 E-M- 1.38 51 Installation .Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing up to two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required./DSR 2022 E-M- 1.35 52 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator), 4 way (4 + 12), Double door/DSR 2022 E-M- 2.4.1 53 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator), 16 way, Double door/DSR 2022 E-M- 2.3.4 54 Supplying and fixing following rating, double pole, the existing MCB DB complete with connections, testing and commissioning etc. as required., 40 A/DSR 2022 E-M- 2.12.1 55 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required., 63 A/DSR 2022 E-M- 2.13.2 56 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required., Single pole/DSR 2022 E-M- 2.10.1 57 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required./DSR 2022 E-M- 2.11 58 Earthing with G.l. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required./DSR 2022 E-M- 5.2 59 Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt) as required./DSR 2022 E-M- 5.3 60 Supplying and laying 25 mm X 5 mm G.l. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.l. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.l. nut bolt & spring washer spaced at 50mm)/DSR 2022 E-M- 5.9 61 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing./DSR 2023- 10.18 62 Supply & erection of AC 230/250 volts 50 hz Exhaust fans including provding nut bolts mounting frame and other accessories including connection etc complete as required as per direction of E /I make:- Havells / Cromption / USHA.300 mm Sweep 900 RPM/- M.R.27 63 Supply & fixing of following white RJ 45 cat 6 data outlet / information outlet ETL verified to meet exceed TIA / ETA/- M.R.28 64 Supply & fixing of following Telephone outlet/- M.R.29 65 Supply of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete, including tube on surface complete in all respect.1 X 22 W/- M.R.31 66 Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment)./DSR - 2020 (Horticulture)- 2.2 67 Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-Charge./DSR 2023- 2.36 68 Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m.lead complete (Cattle manure measured in stacks will reduced by 8% for Payment)./DSR - 2020 (Horticulture)- 2.25 69 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge/DSR - 2020 (Horticulture)- 2.9 70 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately)./DSR - 2020 (Horticulture)- 2.8 71 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure)./DSR - 2020 (Horticulture)- 2.1 72 Rough dressing the trenched ground including breaking clods./DSR - 2020 (Horticulture)- 2.5 73 Fine dressing of the ground./DSR - 2020 (Horticulture)- 2.7 74 Providing & laying Selection no. 1 doob grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge/DSR - 2020 (Horticulture)- 2.34 75 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge., All kinds of soil/DSR 2023- 2.6.1 76 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :, 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)./DSR 2023- 4.1.8 77 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement, All works upto plinth level, Concrete of M25 grade with minimum cement content of 330 kg /cum/DSR 2023- 5.33.1.1 78 Centering and shuttering including strutting, propping etc. and removal of form for :, Foundations, footings, bases of columns, etc. for mass concrete/DSR 2023- 5.9.1 79 Applying stamping finish to the top surface of freshly laid plain / reinforced cement concrete of specified grade in portico, side walks, drive ways, pool decks and open yard as per direction of the Engineer-in-Charge. * The concrete shall be placed and screened to the finished grade and floated to the uniform surface by using standard finishing techniques. approved color hardener @ 2.7 kg/sqm shall be applied evenly to the surface of the fresh concrete by the dry shake method by sprinkling in twoor more shakes floated after each shake and trowel only after final floating. The approved released agent @ 0.113 Kg/Sqm shall be applied evenly to the trowelled surface before stamping or the said release agent can be applied to the flexible polyurethene stamp moulds of approved design and in required sizes to achieve final stamping pattern. These stampings shall be placed on the surface of concrete in three to four pieces at a time and tapped gently with rammers of sufficient size and weight to leave proper stamp marks and the process repeated for the remaining concrete surface till the whole surface to be stamped is completed within the time while the concrete is in plastic stage of setting. * After stamping, the curing shall be done as per manufacturers specifications. After initial curing the imprinted joints shall be grouted using cement slurry mixed with color hardener as per the requirement. The surface shall be sealed by applying acrylic based sealer not less than 0.167 litre/Sqm on finished surface. * The construction joints shall be provided by grove cutting of size 4 mm x 20 mm in panel size 3 m x 3 m or lesser as per the site conditions and filling the same with 10 mm baker rod and providing & laying (PU) Polyurethane based joint sealer of approved make as per manufacturer’s specifications and finished by applying polyurethene resin based topprotective clear coat of minimum 80 micron applied with rollers on properly cured and dry clean surface. (The cost of concrete for flooring is not included in the item, which shall be paid for seperately)./DSR 2023- 26.83 80 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :, Cement mortar 1:6 (1 cement : 6 coarse sand)/DSR 2023- 6.4.2 81 12 mm cement plaster of mix :, 1:4 (1 cement: 4 coarse sand)/DSR 2023- 13.4.1 82 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete./DSR 2023- 13.80 83 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour., Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger, J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface)/DSR 2023- 13.82.2 84 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete., Fixed to openings /wooden frames with rawl plugs screws etc./DSR 2023- 9.48.2 85 Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete., 1:1½:3 (1 Cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)./DSR 2023- 4.6.1 86 Mild steel or iron work in plain work such as in R.C.C. or R.B. (when not included in an over all rates ) including bending for proper completion of the work and including supply of steel and its wastage , bends, hooks and authorised overlaps shall be measured up to floor two level. (SI No. 504) (Sanction Rate)/- SI 504 87 Providing & fixing of Dustbin made in mild steel frame with painting & polish and frame wooden member fixed in m.s. frame including painting polishing as per drawing & design all complete in direction of engineer in charge. PSR/- PSR 4394.77 88 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :, 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)/DSR 2023- 5.1.2 89 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :, 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)/DSR 2023- 5.2.2 90 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources)./DSR 2023- 5.3 91 Centering and shuttering including strutting, propping etc. and removal of form for :, Lintels, beams, plinth beams, girders, bressumers and cantilevers/DSR 2023- 5.9.5 92 Centering and shuttering including strutting, propping etc. and removal of form for :, Columns, Pillars, Piers, Abutments, Posts and Struts/DSR 2023- 5.9.6 93 Centering and shuttering including strutting, propping etc. and removal of form for :, Stairs, (excluding landings) except spiral-staircases/DSR 2023- 5.9.7 94 Centering and shuttering including strutting, propping etc. and removal of form for :, Suspended floors, roofs, landings, balconies and access platform/DSR 2023- 5.9.3 95 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)./DSR 2023- 4.10 96 Providing and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil./DSR 2023- 4.13 97 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured./DSR 2023- 22.6 98 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with M.S hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/ window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variationin profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made., Frame size 65 x 100 mm/DSR 2023- 26.86.5 99 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately), 30 mm thick/DSR 2023- 26.87.1 100 Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod pf approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS:16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for: (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 (ii) Sites with structure height more than 20m for all wind speeds., Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body., Two track four panels sliding windows with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on three panels along with multi-point locking system, nylon rollers with SS 304 body., Two and half track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body., Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body., Three track three panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body., Two track two panels sliding door with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system, adjustable nylon rollers with SS 304 body., Two track four panels sliding door with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on three panels along with multi-point locking system, adjustable nylon rollers with SS 304 body., Three track three panels sliding door with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on two panels along with multi-point locking system, adjustable nylon rollers with SS 304 body., Using R3 series with frame (98mm & above) x (40mm & above) & both glazed and fly screen sash (30mm & above) x (74mm & above). (Height upto 2.5 meter)./DSR 2023- 9.147.B3.1 101 Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)/DSR 2023- 9.53 102 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete :, 125x64x1.90 mm/DSR 2023- 9.70.1 103 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :, 200x10 mm/DSR 2023- 9.97.3 104 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete./DSR 2023- 9.76 105 12 mm cement plaster of mix :, 1:6 (1 cement: 6 coarse sand)/DSR 2023- 13.4.2 106 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections/DSR 2023- 5.30 107 Extra for lining out plaster to imitate stone or concrete blocks walling./DSR 2023- 13.27 108 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling & dressing & finishing the top smooth./DSR 2023- 4.17 109 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily., Glazed Vitrified tiles Matt/Antiskid finish of size, Size of Tile 600 x 1200 mm/DSR 2023- 11.41A.3.2 110 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:, New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)/DSR 2023- 13.47.1 111 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour:, New work (two or more coats) over and including Water thinnable priming coat with cement primer having VOC content less than 50 gram/litre./DSR 2023- 13.41.1 112 Tensile with structure/- Tensile 113 Stone work (machine cut edges Veneer work) for wall lining upto 10 m height, backing filled with a grout of 12 mm thick cement mortar 1:3 (1 Cement : 3 coarse sand) and jointed with Cement mortar 1:2 (1 cement : 2 stone dust), including rubbing and polishing complete. (To be secured to the backing and the sides by means of cramps and pins which shallbe paid for separately)., Kota stone slabs exposed face dressed and rubbed., 25 mm thick/DSR 2023- 8.18.1.1 114 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)./DSR 2023- 10.28 115 Providing and fixing soil, waste and vent pipes :, 100 mm dia., Sand cast iron S&S pipe as per IS: 1729./DSR 2023- 17.35.1.1 116 Providing & fixing UPVC Floor trap of self cleansing design with CP Jali complete in all respects. (Make : Supreme / Finolex / Prince).P-Trap type Floor Trap 110 x 75 mm/- M.R 03 117 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps./- M.R 04 118 Providing & fixing 50 mm. dia. G.I elbow (drain point) in the toilet floor including 50 mm dia. C.P. waste jali complete as required./- MR 05 119 Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25 mm with two chromium plated brass brackets fixed withC.P. brass screws and PVC sleeves etc., wherever necessary complete :, 20 mm dia/DSR 2023- 9.46.2 120 Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti -microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threadedpolypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge.External work, PN - 10 Pipe, 160 mm OD (SDR-11)/DSR 2023- 18.6.10