Tender For Comprehensive Maintenance Of Dg Sets Under Age E/M-Ii Of Ge (U) Chandimandir.; 1 Servicing/ overhauling of self starter of DG set 12 Volt of cap 10 KVA to 75 KVA i.e. opening, checkingand cleaning of self including replacement of carbon bushes if required and making it free from dust and reassembling after replacement of UNSV worn out parts if required for smooth operation and reinstallation to DG set of any make/model complete as per satisfaction of Engineer-in-Charge.Note: Cost of replacement of carbon bushes is included in the rates quoted against this item however other spares required for making self serviceable will be paid separetely in relevant items of schedule hereinafter. 2 Supplying and fixing as in replacement of burn out solenoid switch as per site requirement and as directed by Engineer-in-Charge. 3 M & L for rewinding of burn out armature of self starter as per site requirement and as directed by Engineer-in-Charge. 4 Servicing/ overhauling of self starter of DG set 12/24 Volt of cap 125 KVA to 250 KVA i.e. opening, checkingand cleaning of self including replacement of carbon bushes if required and making it free from dust and reassembling after replacement of UNSV worn out parts if required for smooth operation and reinstallation to DG set of any make/model complete as per satisfaction of Engineer-in-Charge.Note: Cost of replacement of carbon bushes is included in the rates quoted against this item however other spares required for making self serviceable will be paid separetely in relevant items of schedule hereinafter. 5 Supplying and fixing as in replacement of burn out solenoid switch as per site requirement and as directed by Engineer-in-Charge. 6 M & L for Rewinding of burn out armature of self starter as per site requirement and as directed by Engineer-in-Charge. 7 Servicing/ overhauling of self starter of DG set 24 Volt of cap 320 KVA to 500 KVA i.e. opening, checkingand cleaning of self including replacement of carbon bushes if required and making it free from dust and reassembling after replacement of UNSV worn out parts if required for smooth operation and reinstallation to DG set of any make/model complete as per satisfaction of Engineer-in-Charge.Note: Cost of replacement of carbon bushes is included in the rates quoted against this item however other spares required for making self serviceable will be paid separetely in relevant items of schedule hereinafter. 8 Supplying and fixing as in replacement of burn out solenoid switch as per site requirement and as directed by Engineer-in-Charge. 9 M & L for rewinding of burn out armature of self starter as per site requirement and as directed by Engineer-in-Charge. 10 M & L for Repair/ replacement of (AVR) automatic voltage regulator Diode forward and reverse rotating rectifier assembly, half wave phase controlled thyristor type,complete all as per existing type & size for DG set of capacity 10 KVA to 75 kVA, complete all as specified and directed by Engineer-in-Charge. 11 All as per item No 4 above but for DG set of capacity 125 to 250 KVA . 12 All as per item No 4 above but for DG set of capacity 500/400/320 KVA . 13 Taking out of radiator/ aftercooler if required from DG set 10 KVA to 75 KVA of any make/model and cleaning of radiator by removing of dust/oil particles and cleaning of copper tubesby using suitable cleaning agent for any obstacles inside the tube and refixing it complete all as directed by Engr-in-Charge. 14 All as per item No 7 above but for DG set 125 to 160 KVA . 15 All as per item No 7 bove but for DG set 200 to 250 KVA . 16 All as per item No 7 above but for DG set 320 to 500 KVA . 17 M & L for disconnecting and taking down the leaking radiator from DG set engine and transporation to civil workshopfor repairs, cleaning the complete radiator for detecting the leakage and repairing the leaking portion (Tubes/fins/tank etc)by soldering/brazing, cleaning of all water tubes with suitable cleansing agent &water pressure & removing the complete sludge and dust from inside the tank, replacing worn out hose pipes & clamps etc, shifting & refixing at original site and testing for proper working, for the DG set of capacity 10 KVA to 160 KVA, complete all as specified and directed by Engineer-in-Charge. 18 M & L for disconnecting and taking down the leaking radiator from DG set engine and transporation to civil workshopfor repairs, cleaning the complete radiator for detecting the leakage and repairing the leaking portion (Tubes/fins/tank etc)by soldering/brazing, cleaning of all water tubes with suitable cleansing agent &water pressure & removing the complete sludge and dust from inside the tank, replacing worn out hose pipes & clamps etc, shifting & refixing at original site and testing for proper working, for the DG set of capacity 200 KVA to 500 KVA, complete all as specified and directed by Engineer-in-Charge. 19 M & L for disconnecting and taking down the defective Charging Alternator from the DG set engine, shifting to civil workshop for repairs, strip opening to remove unserviceable parts, repairing by replacing of armature coil, carbon bush, field coil, clutch patti bearing, refixing magnetic steel laminates, replacing pole head and pole shoe, bearings of shaft ball/roller/sleeve type, and other related items of the assembly as required to make it serviceable, re-assembling and refxing the same on original positionand testing complete for the DG set of capacity 10 KVA to 75 KVA, complete all as specified and directed by Engineer-in-Charge. 20 All as per item No 13 above but for the DG set of capacity 125 KVA to 250 KVA . 21 All as per item No 13 above but for the DG set of capacity 320 KVA to 500 KVA 22 Material and labour as in replacement controller display as per model at site for DG Set 62.5 KVA to 125 KVA capacity of any make for proper functioning of DG set through controller and connected wiring etc complete all as specified and directed. 23 Material and labour as in replacement controller display as per model at site for DG Set 200 KVA to 320 KVA capacity of any make for proper functioning of DG set through controller and connected wiring etc complete all as specified and directed. 24 Material andlabour foroverhauling of all injecter nozzles includingall as per site requirment, washers etc and pressure setting as required andreplacement of timing shaft with coupling for DG sets of 320 KVA to 500 KVA capacity, complete all as specified and directed.. 25 All as per item no 18 above but for DG sets 125 KVA to 250 KVA . 26 All as per item no 18 above but for DG sets 62.5 KVA to 75 KVA . 27 All as per item no 18 above butfor DG sets 40 KVA to 10 KVA . 28 Disconnecting and taking down the fuel pump (FIP) from the DG engine, transporting to civil workshop and repair & calibration of FIP of DG Set including replacement of plungers, washer manifold, injection nozzles etc all as required and testing after refixing on engine and setting the rated RPM, for DG set of capacity 320 KVA to 500 KVA, complete all as specified and directed. 29 All as per item No 22 above but for DG sets 125 KVA to 250 KVA . 30 All as per item No 22 above but for DG sets 62.5 KVA to 75 KVA . 31 All as per item no 22 above butfor DG sets 40 KVA to 10 KVA . 32 Supply and filling engine oil grade 15W40 premium grade, complete all as specified and directed. 33 Supply and filling distilled water in batteries for toppping up, complete all as specified and directed. 34 M&L for draining out old coolant from the engine radiators of DG Sets of any capacity and make, flushing the radiator tubes with water and refixing the drain plug properly after filling the complete radiator with new pre mixed coolant, complete all as specified and directed. Make:- Servo/Castrol/HP/Bharat Petroleum 35 Supply and fix as in replacement battery leads set for battery of any capacity installed at various power Housesappx 1.5 Mtr long, PVC insulated multistranded copper conductor ofstandard size as per site, duly fixed brass clamps, copper lugs for connections from DG battery to self starter on DG Sets of any capacity all as specified and directed. 36 Supply and fixing as in replacement heavy duty brass terminals(as per approved sample) suitable for battery terminals complete all as specified and as directed. 37 M & L for cleaning the in-builtdiesel tanks of 320 KVA to 500 KVA capacity DG set by emptying the tank using suction pump of suitable capacity, washing the internal walls & bottom with diesel to remove any dust / deposits etc complete all as specified and as directed. 38 All as per item no 31 above but for DG set capacity 160/200/250 KVA 39 All as per item no 31 above but for DG set capacity 10/40 KVA 40 All as per item no 31 above but for DG set capacity 125/ 62.5/75 KVA 41 M&L for repairing the doors of sound proof enclosure of 250 KVA 500 KVA DG Set for proper closing and locking using new SS hinges/door handles / in built locks as required complete all as per existing all as specified and directed. 42 All as per item No 35 above but for DG set 10 KVA to 40 KVA DG set 43 All as per item No 35 above but for DG set 62.5 KVA to 200 KVA DG set 44 Supply and fixing as in replacement the broken/ damaged fuel tank lock with key for DG set of cap 160 KVA to 500 KVA all as per existing all as specified and directed. 45 Supply and fixing as in replacement the broken/ damaged fuel tank lock with key for DG set of cap 10 KVA to 125 KVA all as per existing all as specified and directed. 46 S & F as in replacement maintenance free lead acid sealed lead accumilater (SMF) 12 volts 150/180 Ah battery for DG set complete all as specified and as directed. 47 S & F in replacement maintenance free lead acid sealed lead accumilater (SMF) 12 volts 80/100 Ah battery for DG set complete all as specified and as directed. 48 Attending defective/ non functional DG Setcomplaints of capacty 10 KVA to 500 KVA(all type of errorr/fault alarms displayed on screen of the control panel) by service engineers/technically qualified teamsto rectify the defects by made adjustments/settingsin control panel or to inform the major/minor repair that include cost more than Rs 500 to make DG Serviceable of any type as per existing, checking of connections, testing and DG Set shouldworking in good conditions etc complete all as specified and as directed. Notes :-(a) On receiving of complaint, it should be attended by service Engineer /rep of OEM within 24 Hrs, if not attendedpenalty @ Rs 500 per hour will be recovered from contractor. Failure on the part of contractor to make the DG Set functional after receipt of complaint, penalty @ Rs 1000 per day will be recovered from contractor unless major repair required out of the scope of this item. (b) All type of T & P, minor nuts/bolts/washers etc required for maintaining the services shall be provided by the contractor without any extra cost to department.(c) Repair item costing less than Rs 500 to make DG Serviceable is deemed to be included in the quoted rate of item. 49 M & L as in repair of the diesel tanks of 125 KVA to 500 KVAcapacity DG set by emptying the tank using suction pump of suitable capacity, washing the internal walls, welding/ soldering leakageof diesel tank of bottom and washed with diesel to remove any dust / deposits etc, complete all as specified and as directed. 50 M&L as in replacement of magnetic sensor for 250 KVA to 500 KVA capacity DG set of makeKirloskar/CG /Cummins etc all as per existing, including replacing the worn out gaskets/nuts/bolts/washers etc as required complete all as specified and as directed. 51 M&L as inreplacement of water pumpfor200 KVA to 400 KVA capacity DG set of makeKirloskar/CG /Cummins etc all as per existing, including replacing the worn out gaskets/nuts/bolts/washers etc as required complete all as specified and as directed. 52 Supply and fix of onload changeover switch with sheet metal enclosure of cap 63 amps as in replacement of UNSV/burnout Changeover switch any type complete all as specified and as ditected by Engineer-in -Charge. 53 Supply and fix of onload changeover switch with sheet metal enclosure of cap 125 amps as in replacement of UNSV/burnout Changeover switch complete all as specified and as ditected by Engineer-in -Charge. 54 Supply and fix of onload changeover switch with sheet metal enclosure of cap 200 amps as in replacement of UNSV/burnout Changeover switch complete all as specified and as ditected by Engineer-in -Charge. 55 Supply and fixing of asbestos rope to exhaust pipe of DG set of any Cap as per existing size and colour as directed by Engineer in Charge 56 Supplying, fixing and connectingpanel mounting type battery Charger with transformer diode operated (not PCB) 12/ 24 Volts, 30 Amps with copper winding including removing the unserviceable from the existing position complete all as directed. 57 M & L for taking down defective turbo charger after dismantling from DG set of cap 125 KVA to 250 KVA of any make and taking it to workshop for checking and if found repairable, get it repaired and achieve factory parameters during repair, using replacement of original spare parts as required after overhauling and refixing at site for smooth operation of DG set complete all as directed by Engineer-in-Charge. 58 M & L for taking down defective turbo charger after dismantling from DG set of cap 320 KVA to 500 KVA of any make and taking it to workshop for checking and if found repairable, get it repaired and achieve factory parameters during repair, using replacement of original spare parts as required after overhauling and refixing at site for smooth operation of DG set complete all as directed by Engineer-in-Charge. 59 M & L for taking down defective turbo charger after dismantling from DG set of cap 10 KVA to 75 KVA of any make and taking it to workshop for checking and if found repairable, get it repaired and achieve factory parameters during repair, using replacement of original spare parts as required after overhauling and refixing at site for smooth operation of DG set complete all as directed by Engineer-in-Charge. 60 M&L for preparation of old painted surfaces of the DG Set including radiator, fuel tank etc complete degreasing and spray painting the same with two coats of approved paint including writing SM/MES nos on DG set of capacity 10 KVA to 75 KVA all as directed by Engineer-in-charge. 61 M&L for preparation of old painted surfaces of the DG Set including radiator, fuel tank etc complete degreasing and spray painting the same with two coats of approved paint including writing SM/MES nos on DG set of capacity 250 to 500 KVA all as directed by Engineer-in-charge. 62 S&F as in replacement, digital type 3 phase ammeter/voltmeter of size96x96mm as per site complete all as specified and as directed. 63 M&L Cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate for foundations, mass and for repairing to paths/ road & hardstanding etc. including necessary cutting of roads/ paths for passing of pipes and making good the disturbed portion complete all as specified and directed by Engineer – in - Charge. 64 Supply and laying as in replacement 160mm outer dia, double walled, corrugated HDPE duct pipe conforming to IS-16205 with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed. 65 Supply and laying as in replacement 110mm outer dia, double walled, corrugated HDPE duct pipe conforming to IS-16205 with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed. 66 Supply and laying as in replacement 90mm outer dia, double walled, corrugated HDPE duct pipe conforming to IS-16205 with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed. 67 Supply and laying as in replacement 63mm outer dia, double walled, corrugated HDPE duct pipe conforming to IS-16205 with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed. 68 M&L for Shifting of 10 KVA to 160 KVA Canopy type DG Set complete with all its attachments (by dismantling and refixing of its sensitive parts as required) using suitable mechanical pulling / lifting devices / cranes etc from its original location and relocating to a new position within 1 KM by disconnection of its power supply cables from its existing location and reconnection at new location by providing all requisite connection materials and all as directed by Engr-in-charge. 69 M&L for Shifting of 200 KVA to 500 KVA Canopy type DG Set complete with all its attachments (by dismantling and refixing of its sensitive parts as required) using suitable mechanical pulling / lifting devices / cranes etc from its original location and relocating to a new position within 1 KM by disconnection of its power supply cables from its existing location and reconnection at new location by providing all requisite connection materials and all as directed by Engr-in-charge. 70 Supply and laying as in replacement 80 mm bore tube light grade galvanised iron pipe laid in trenches or fixed along poles with mild steel clamps or protection to GI earth strip/cable, complete all as specified and directed by Engr-in- Charge. 71 Supply and laying as in replacement 50 mm bore tube light grade galvanised iron pipe laid in trenches or fixed along poles with mild steel clamps or protection to GI earth strip/cable, complete all as specified and directed by Engr-in- Charge. 72 Supply and fixHeat Shrinkjointing kit for 1100 volts grade cable for Indoor/Outdoor end jointcomplete with jointing material and accessories suitable for 3.5 core XLPE cable of size 70 to 120 Sqmm complete all as specified. 73 Supply and fixHeat Shrinkjointing kit for 1100 volts grade cable for Indoor/Outdoor end jointcomplete with jointing material and accessories suitable for 3.5 core XLPE cable of size 150 to 185 Sqmm complete all as specified. 74 Supply and fixHeat Shrinkjointing kit for 1100 volts grade cable for Indoor/Outdoor end jointcomplete with jointing material and accessories suitable for 3.5 core XLPE cable of size 240 to 300 Sqmm complete all as specified. 75 M&L earthing complete with galvanized steel plate electrode 60 cmx 60 cm x 6 mm surrounded by charcoal & salt buried directly in a pit of depth not less than 2.25 m below ground level with top edge of the earth plate at a depth of not less than 1.50m below ground level, connected to and including GI srtip 25 x 4 mm. upto 7.5m length by means of bolts, nuts, check nuts & washers of galvanized iron, earth wire protected by galvanized steel pipe 40 mm bore (medium grade) & connected to main control board including necessary excavation & earth work, disposal of surplus soil not exceeding 50m, in any type of soil. (The rate also includes for cost of charcoal & salt in alternate layers of 15 cm thickness, 20 mm bore GI pipe (medium grade) for watering, funnel, wiremesh, PCC chamber in cement concrete (1:2:4) type B-1, CI cover& frame etc) complete all as indicated in electric plate No 3 of SSR 2009 Part I including testing complete all as specified and as directed.Note- (i) Earthing result/data sheet will be prepared by the Contractor and submitted to Engineer-in-charge. Earth resistance shall be to the entire satisfaction of engineer-in-charge and contractor will make all arrangements & provisions to get the desired reduction of resistance by artificial treatment/replacement of soil etc at no extra cost to department. 76 Supply and fix ofGI strip 25 x 4 mm for earthing complete all as specified and directed by Engr-in-Charge. 77 M&L as in replacement of Power Cables, Aluminium Stranded Conductor 300 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge. 78 All as per item No 71above but185 sqmm 3.5 core. 79 All as per item No 71 above but95 sqmm 3.5 core. 80 All as per item No 71 above but70 sqmm 3.5 core. 81 All as per item No 71 above but35 sqmm 3.5 core. 82 All as per item No 71 above but25 sqmm 4.0 core. 83 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and as directed.Note: Nothing extra will be paid or measured to the contractor if hard or rocky soil is encountered during execution . 84 Returning, filling in soils, in trenches, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed 85 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.Note: Nothing extra will be paid or measured to the contractor if hard or rocky soil is encountered during execution . 86 Servicing of DG Set 500/400/320 KVA capacity of Make :-Kirloskar/Cummins/Crompton Greaves,taking down worn out replaceable parts such as lube oil flexible pipe, hose pipes, clamps etc and replacing as required the same with same size, make and capacity of parts, and including testing complete all as specified and directed. Note:-(i) Spare parts such as fuel filter cartridge/lube oil filters/Fuel Filter/ air filter primary/ air filter safety shall be measured and paid for saperately under respective items here in after as supply only. 87 Supply only Fuel filter cartridge 88 Supply only Lube oil filter assembly with O rings 89 Supply only spinon preline filter cartridge 90 Supply only Air filter primary element 91 Supply only Air cleaner safety element 92 Supply only V beltBX58 PITCH 1520 Long 93 Supply only V Wrapped Belt : SPB AR 1230 - 3 Set 94 Servicing of DG Set 250/200 KVA capacity of Make :-Kirloskar/Cummins/Crompton Greaves,taking down worn out replaceable parts such as lube oil flexible pipe, hose pipes, clamps etc and replacing as required the same with same size, make and capacity of parts, and including testing complete all as specified and directed as supply only. Note:-(i) Spare parts such as fuel filter cartridge/lube oil filters/Fuel Filter/ air filter primary/ air filter safety shall be measured and paid for saperately under respective items here in after. 95 Supply only Fuel filter kit 1.1 ltr 96 Supply only spinon Lube oil filter assembly with O rings 97 Supply only spinion fuel filter assembly with O rings 98 Supply only Air filter safety element 99 Supply only Air filter safety element 100 Supply only poly V belt 8PK : 1065 101 Supply only poly V belt 4PK : 1515 102 Servicing of DG Set 125 KVA to 160KVA capacity of Make :-Kirloskar/Cummins/Crompton Greaves,taking down worn out replaceable parts such as lube oil flexible pipe, hose pipes, clamps etc and replacing as required the same with same size, make and capacity of parts, and including testing complete all as specified and directed. Note:-(i) Spare parts such as fuel filter /lube oil filters/Fuel pre filter/ air filter primary/ air filter safety shall be measured and paid for saperately under respective items here in after as supply only. 103 Supply only Fuel filter cartridge 104 Supply only spinon Lube oil filter 105 Supply only bypass filter 106 Supply only fuel filter element type 107 Supply only primary Air filter element 108 Supply only V belt6R1080T/TA 7PK 109 Supply only poly V belt 110 Servicing of DG Set 62.5 to 75 KVA capacity of Make :-Kirloskar/ Cummins/ Crompton Greaves/ Mahindra,taking down worn out replaceable parts such as lube oil flexible pipe, hose pipes, clamps etc and replacing as required the same with same size, make and capacity of parts, and including testing complete all as specified and directed. Note:-(i) Spare parts such as fuel filter mircro/lube oil filters/Fuel pre filter/ air filter element shall be measured and paid for saperately under respective items here in after as supply only. 111 Supply only Fuel filter element primary 112 Supply only Fuel filter element secondary 113 Supply only spinon Lube oil filter 114 Supply only primary Air filter element 115 Supply only 4PK EPDM Poly V belt 116 Servicing of DG Set 40 KVA capacity of Make :-Kirloskar/Cummins/Mahindra/Ceompton Greaves,taking down worn out replaceable parts such as lube oil flexible pipe, hose pipes, clamps etc and replacing as required the same with same size, make and capacity of parts, and including testing complete all as specified and directed. Note:-(i) Spare parts such as fuel filter mircro/lube oil filters/Fuel pre filter/ air filter element shall be measured and paid for saperately under respective items here in after as supply only. 117 Supply only Fuel filter element primary 118 Supply only Fuel filter element secondray 119 Supply only spinon Lube oil filter 120 Supply only primary Air cleaner element 121 Supply only poly V belt 122 Servicing of DG Set 10 KVA capacity of Make :-Kirloskar/Cummins/Mahindra/Ceompton Greaves,taking down worn out replaceable parts such as lube oil flexible pipe, hose pipes, clamps etc and replacing as required the same with same size, make and capacity of parts, and including testing complete all as specified and directed. Note:-(i) Spare parts such as fuel filter mircro/lube oil filters/Fuel pre filter/ air filter element shall be measured and paid for saperately under respective items here in after as supply only. 123 Supply only one time filter kit 0.5 Ltr 124 Supply only Air cleaner element 125 Servicing of AMF panel of DG set 10-62.50 KVAofcapacity cleaning the complete panel with suitable cleaning agent and checking the controller relays, timer, contactors forproper functioning, replacing defective spare parts, replacement of defective small wires, MCBs of existing size, tightening of all connections and applying jelly on contactors, panel locks and handle complete all as specified and directed by Engineer-in-Charge.Note : (i) Spare parts required will be measured and paid separately as Supply Only but cost of small wires, MCBs, door locks, handle shall be included in the quoted rate. 126 Servicing of AMF panel of DG set 75-125 KVAofcapacity cleaning the complete panel with suitable cleaning agent and checking the controller relays, timer, contactors forproper functioning, replacing defective spare parts, replacement of defective small wires, MCBs of existing size, tightening of all connections and applying jelly on contactors, panel locks and handle complete all as specified and directed by Engineer-in-Charge.Note : (i) Spare parts required will be measured and paid separately as Supply Only but cost of small wires, MCBs, door locks, handle shall be included in the quoted rate. 127 Servicing of AMF panel of DG set 160-250 KVAofcapacity cleaning the complete panel with suitable cleaning agent and checking the controller relays, timer, contactors forproper functioning, replacing defective spare parts, replacement of defective small wires, MCBs of existing size, tightening of all connections and applying jelly on contactors, panel locks and handle complete all as specified and directed by Engineer-in-Charge.Note : (i) Spare parts required will be measured and paid separately as Supply Only but cost of small wires, MCBs, door locks, handle shall be included in the quoted rate. 128 Servicing of AMF panel of DG set 320-500 KVAofcapacity cleaning the complete panel with suitable cleaning agent and checking the controller relays, timer, contactors forproper functioning, replacing defective spare parts, replacement of defective small wires, MCBs of existing size, tightening of all connections and applying jelly on contactors, panel locks and handle complete all as specified and directed by Engineer-in-Charge.Note : (i) Spare parts required will be measured and paid separately as Supply Only but cost of small wires, MCBs, door locks, handle shall be included in the quoted rate. 129 Supply onlyAuto / Manual switch complete assembly suitable for existing (make & model) DG set AMF Panels, 3 Phase, 415 Volts, 50 Hz. 130 Supply only Start/stop push button complete assembly suitable for existing (make & model) DG set AMF Panels, 3 Phase, 415 Volts, 50 Hz. 131 Supply only LED indicator lamp assemblyred, yellow, blue complete all as specified and as directed. 132 Supply only4 pole contactor 110 Amps, suitable for existing (make & model) DG set AMF Panels, 3 Phase, 415 Volts, 50 Hz.