Design, Engineering, Manufacture, Survey, Supply, Transportation, Erection, Testing & Commissioning Of 1X6.3 Mva, 33/11Kv Receiving Station Including 33 Kv Line At Gmc Associate Hospital Rajouri On Turnkey Basis.” Under The Jurisdiction Of Executive Engin, rajouri-Jammu And Kashmir

Tender Notice

51751861
Design, Engineering, Manufacture, Survey, Supply, Transportation, Erection, Testing & Commissioning Of 1X6.3 Mva, 33/11Kv Receiving Station Including 33 Kv Line At Gmc Associate Hospital Rajouri On Turnkey Basis.” Under The Jurisdiction Of Executive Engin
Tender
Indian
Jammu And Kashmir
Rajouri
28-10-2025

Tender Details

Design, Engineering, Manufacture, Survey, Supply, Transportation, Erection, Testing & Commissioning of 1x6.3 MVA, 33/11KV Receiving Station including 33 KV Line at GMC Associate Hospital Rajouri on Turnkey Basis.” under the jurisdiction of Executive Engineer, Sub Transmission Division KALAKOTE, JPDCL Jammu- 1 33 KV LINE BAY OF SINGLE BUS SCHEME (2 Nos); (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 2 SITC OF SUB‐STATION MAIN EQUIPMENT 3 33 KV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type)with allied accessories and heavy duty pad clamps. 4 33kV C&R Panel along withO/C, E/F relays, mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Smart meter -5 Amps with RS-485 port, DLMS Compliant with RS-485 port 5 33 kV Isolator With Earthing Blade with allied accessories and pad clamps(36kV,1250A, Outdoor,3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 6 33 kV Isolator Without Earthing Blade with allied accessories and pad clamps(36kV,1250A, Outdoor,3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 7 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) 8 33 kV Voltage Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor), (1No. per Φ) 9 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less 10 33 kV Polymer Post Insulator36kV,170kV Impulse, creepage distance 1224m 11 SITC OF GI STEEL STRUCTURES 12 Nominal Bore 200, 5.9 mm Thick 13 Galvanised Steel Structures 14 Galvanised Nuts & Bolts 15 SITC OF CONTROL CABLES 16 Supply, Laying, Testing & Commissioning of 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI,FRLS as per relevant Standards 17 Supply, Laying, Testing & Commissioning of 04Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI,FRLS as per relevant Standards 18 Supply, Laying, Testing & Commissioning of 02 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI,FRLS as per relevant Standards 19 Lugs, Ferrules etc. 20 SITC OF CONDUCTOR & HARDWARE 21 Providing & Fixing 200 mm² ACSR Conductor Panther 22 Providing & Fixing of 630A T-clamps suitable for 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per relevant Standards 23 Providing & Fixing of Aluminium Tention Fittings of 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per Relevant Standards 24 Providing & Fixing Polymeric composite Disc Insulator 36KV, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm,min failing load 70kN 25 GI Earth wire 7/4.00 mm sq. 26 Providing & Fixing of GI flat for earthing 50x6mm with epoxy insulator along with clampsas per relevant Standards 27 COST FOR 33 kV TRANSFORMER BAY OF SINGLE BUS SCHEME (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 28 SITC OF SUB‐STATION MAIN EQUIPMENT 29 33 KV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) with allied accessories and heavy duty pad clamps. 30 33 kV Isolator with Without Earthing Blade with allied accessories and pad clamps(36kV,1250A, Outdoor,3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 31 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) 32 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less 33 33 kV C&R Panelalong with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Smart meter -5 Amps, DLMS Compliant with RS-485 port 34 33 kV Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224m 35 SITC OF GI STEEL STRUCTURES 36 Nominal Bore 200, 5.9 mm Thick 37 Galvanised Steel Structures 38 Galvanised Nuts & Bolts 39 SITC OF CONTROL CABLES 40 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 41 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 42 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 43 Lugs, Ferrules etc. 44 SITC OF CONDUCTOR & HARDWARE 45 Providing & Fixing 200 mm² ACSR Conductor Panther 46 Providing & Fixing of 630A T-clamps suitable for 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per relevant Standards 47 Providing & Fixing of Aluminium Tention Fittings of 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per Relevant Standards 48 Providing & Fixing Polymeric composite Disc Insulator 36KV, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm,min failing load 70kN 49 Providing & Fixing of GI Earth wire 7/4.00 mm sq, with 4Nos. 13mtr long ST Poles for Shielding of 33KV Yard along with Power Transformer with proper earthingby GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm 50 Providing & Fixing of GI flat for earthing 50x6mm with epoxy insulator along with clampsas per relevant Standards 51 SITC of 6.3 MVA 33/11KV Power Transformer; (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 52 6.3MVA 33/11kV, ONAN, Copper wound, Out-door Type, conventional Power Transformer, Oil Filled with OLTC and all accessories including HT and LT Terminal connections and Tertiary Winding. 53 Providing & Fixing of Al Bus bars for transformer terminals of suitable size with color coding, heat shrinkable sleeves covered including drilling, welding etc as per requirement to be fixed on LV side of transformer as per relevant Standards 54 Providing & Fixing of GI Earth wire 7/4.00 mm sq, with 4Nos. 13mtr long ST Poles for Shielding of 33KV Yard along with Power Transformer with proper earthingby GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm 55 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 56 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 57 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 58 COST FOR 11 kV INDOOR SWITCHGEAR OF 6.3MVA, 33/11 KV SUBSTATION; (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 59 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, Outdoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port (1+4)SET 60 11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type (4/5/6 Sets) 61 11 kV3- Core XLPE 400 mm² armoured, FRLS 62 11 kV3-Core XLPE 120 mm² armoured, FRLS 63 11 kV Indoor Heat Shrinkable Cable Termination Kits 64 11 kV Outdoor Heat Shrinkable Cable Termination Kits 65 11 kV Indoor Heat Shrinkable Cable Termination Kits 66 11 kV Outdoor Heat Shrinkable Cable Termination Kits 67 11 kV Isolator, double break,3-pole, 600Amp, horizental mounting Type, with Earth Switch. 68 11 Mtr. Long Pole (ST-410 SP56) 69 9 Mtr. Long Pole(ST-410 SP33) 70 33kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp 71 33kV HGF Set 3-Phase, 3-Pole, 200 Amp 72 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp 73 Galvanisedironof sorts including CH Angle brases Clamps etc. 74 100 KVA, 33/0.04 KV, 3-Phase Distribution Transformer with Bimetallic Terminal connectors Energy Level -2 (Copper wound) (1No. Spare) 75 120 mm²PVCLT Cable 4 Core, armoured, FRLS 76 Cement bottoming 1:2:4 mix as per REC standards 0.5cum per pole 77 Earthing of 100 KVA Substation-Excavation of earht pit of dia 650 mm & depth 3000 mm installation of earthing pipe of 40 mm Nominal bore & 4 mm wall thickness & length 2.5 mtr long as per IS 1239 GI Strip[ for neutral earthing of size 75 mm x 10 mm & 50 mm x6 mm for connection of transformer body, G.O set & lightening arrestor as per IS 2629/85, GI Nuts & Bolts, refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover. 78 Supply ,Installation Testing and Commissioning of Earthing Complete by GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm. 79 11kV Bus Bar Fuse Set Out Door type for Auxilary Transformer 80 COMMON MISCELLENOUS WORKS IN 33/11kV SUBSTATIONS; (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 81 Compound wall of Receiving Station By way of mass concreting in foundations and 228mm brick wall of 2 m height including main gate and allied works 82 G.I Chainlink Fencing of 33kv yard by way of mass concreting in foundations and chainlink fencing of 6 ft height using G.I Angle of size 65x65x6mm and G.I Flat iron 50x6mm 83 RCC Cable Duct for laying of 11 KV XLPE Cable from Power transformer to Control Room and Control Room to O/G Structures as per REC Approved Standard Drawing. 84 33/11 kV RCC Power Transformer Foundation (1:2:4) as per REC Approved Standarddrawing foundation complete job for 3.15 MVA Power Transformer 85 33 kV RCC Equipment foundation and Gantry foundationas per REC Approved Standarddrawing (VCB, Isolators, CTs, PIs, LAs etc) complete job 86 Earthing Mat using ( GI Flat 75 x 8mm) and (GI earth rod spikes 2.5 m long 20 mm dia), yard area, as per REC Standerd 87 Earthing Electrode ( 3m long 40mm dia GI pipe) through GI strip (50x6)mm for equipments 88 33 kV Yard concreting and metalling, yard area by providing, supply & laying 100mm thick PCC 1:4:8 using 20mm normal course aggregating and spreading 100mm three layer of 20mm single sized crushed/broken stone, as per REC Standerd 89 Borewell 125mm dia and 100mtr in depth with 2HP Submersible Pump including distribution complete job. 90 BUILDING: A. Control Room Building on ground floorcomplete with Column and Beam structures with 1 no J.E. Room , 1 Store room, 1 Battery Room and a main hall including a luminium windows, cable ducts for power and control cable, Toilet (completewith WC, Washbasin and fittings), electric fittings(fans, LEDtubelights, leds powerpoints and o ther fixtures) 2 coat of putty with Priming coat and Reputed Colour of 2 coats to the entire building as per the direction of concerned engineer , painting of doors and windows etc. Overhead water Storage tanks . Water Supply . Septic Tank complete with Sanitary Fittings including kota stone floor. including RCC slab in furnished conditioncomplete in all respects.(Note: The Contractor shall submit the building drawing in all respects i.e. structural / architectural prepared by authorized Architect for approval from the dept for execution of works.) 91 BUILDING:B. Staff Quarters on 1st floor with Column and Beam structures includingToilets (completewith WC, Washbasin and fittings), electric fittings(fans, LEDtubelights, leds powerpoints and other fixtures of reputed make) Putty of 2 coats , Priming 2 coatsand reputed colour as directed by concerned Engineer to the entire buildingComplete in all respect painting of doors and windows etc. Overhead water Storage tanks . Pantry Room with all the Fittings. Water Supply . including Tile and marble flooring with periphet and Stairs Complete, two room complete with beding chair etc. as per the direction of engineer incharge.(Note: The Contractor shall submit the building drawing in all respects i.e. structral / architechuralprepared by authorised Architect for approval from the dept for execution of works.) 92 Development of land by removing weeds, wild grass and endulation if any, ornamental land scaping and growing of ornamental trees in unbuilt areas/road sides and Construction of approach path by Way of Cement concreteing/ Interlocking tiles/blacktopping including drains complete. 93 SITC of 120 Watts LED Street lights of following watts IP-66/67 protected with lens type LED, Pressure Di-cast aluminium body , 100+ LM/watt, Input voltage AC 85-265 Volts, efficacy 92%, life time more than 45000 Hrs. ( Crompton, Phillips, Jaguar, GE). To be mounted on 13mtr ST Poles including necessaryboxes/fabrication/modification as per requirement. ( the LED lights brand must have conducted the indian photometic test certificate of LM-79 and 80.) 94 COMMON MISCELLANEOUS EQUIPMENTS 33/11kV SUBSTATIONS; (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 95 a). Battery Bank 30 V,100 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelenecopolymer container,flame retardant. b). 30V,100 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply . 96 Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Doublebusbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories 97 Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCBs (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories 98 Providing of Bolt cutter of Taparia make BC-42 with allied accessories. 99 Providing of Rubber Mat 1mx2m 19mm thick 100 Providing of Fire ExtingiusherCo₂/ABCType of 4.5 kg capacity for controlroom 101 Providing of 3Sand Bucket Fire Extingiusherwith metallic stand andidentification plates 102 Providing of Industrial safety Helmet 103 Providing of Rubber Gloves for 33 kV level 104 Providing of Rubber Gloves for 11kV level 105 Providing of Industrial Safety Belt with comfort foam reinforment 106 Providing of Safety volcanized rubber Shoes 107 Providing of Telescopic Cabron fibre Earthing rod (set of 3 rods) 108 Providing of HV Detectors all voltages with fibre rod 109 Providing of Chrome vanadium forged Spanners of 10mm to 32mm sizering/u shaped. (set of 10 No.s) 110 Providing of Forged Adjustable wrench of 22mm and 32mm size 111 Providing of Screw drivers setflat cum star bit type dual end (set of 8 no.sof different sizes) 112 Providing of Nose Plier 113 Providing of Normal Plier 114 Providing of Sledge hammer of 2Kg with handle 115 Providing of forged Chisel long shank type 116 Providing of HSS Cabron steel Hack saw with frame and set of 6 blade withtwo sided teeths 117 Providing of Measuring tape of 12 feet spring loaded 118 Providing of Precise 1 feet long bubble based water level 119 Providing of 600 watt hand drill with drill bits of HSS Hammer type 120 Providing of Tool Kit case plastic of Harry-kerry make of 2.5x1x1.5 feetdimensions with different chambers 121 Providing of Clamp meter with multi measuring parametersMarkoni/motwane/fluke make 122 Providing of Screw driver tester neon lamp based 123 Providing and fixing of industrial heavy duty chain block of 1 Ton capacitywith allied accessories complete 124 Providing of Chrome make socket set with ratchet and extension bars of10mm-32mm size sockets with allied accessories 125 Providing of Aluminum industrial ladder split 40 feet extension type withallied accessories 126 Providing of foldable multi-purpose aluminium ladder 127 Office Steel Chairs wih Armrest 128 Office Table of Standard Size with Sufficient Drawers 129 Office Almirah With Locker of reputed make 130 Cost of Installation of Capacitor Bank (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 131 11 KV Capacitor bank 2.4MVAR with VCB Panel with complete arrangement for connection with 11 KV incomer panel, Series Reactor, Isolator, RVT, Surge Arrestor, HT Cable with termination Kits, Control Cables, CRCA Cubicle Panel etc with Structure, foundation and accessories. 132 SITC OF 33 KV LINE 133 11 Mtr. Long Pole (ST-410- SP56) 134 GI V cross-arm with top Bracket including clamps 135 GI Channel X-Arm including clamps and braces 136 GI Wire SSS 137 100 mm² AL59 Aluminium Claded Steel Conductor 138 PG Clamps for 100mm² ACSR Conductor 139 Tension Clamps with bail & IPC (Insulation Piercing Conductors) 140 Alignment Ties 141 IPC (Insulation Piercing Conductors) from bare to CC (Covered Conductor) 142 IPC from CC to CC Connection 143 IPC with Aluminium bail for Earthing 144 Mid Span Joint 145 33 kV Isolator without Earthing Blade (36kV, 2500A, Outdoor, 3 poles, 25 kA) 146 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 147 33kV Polymeric composite Disc Insulator 36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting 148 Galvanized Nuts and Bolts. 149 Danger Plates with Clamps 150 Anti-Climbing Device with Clamps 151 Earthing Complete by GI Pipe 40 mm or GI Rod20mm, 3 mtr long through GI Strip. 152 Red Oxide 153 Aluminium Paint 154 Cement bottoming for 11 Mtr Long ST Pole, 0.78 Cum/Pole 155 Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete 156 SITC OF 11 kV LINE 157 8 Mtr. Long Pole( ST-410 SP15) 158 GI V cross-arm with top Bracket including clamp 159 GI Channel X-arm including clamps and braces 160 50 mm² ACSR Conductor 161 PG Clamps for 50 mm² ACSR Conductor 162 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 163 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 164 Galvinized Nuts and Bolts 165 Danger Plates with Clamps 166 Anti-Climbing Device with Clamps 167 Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. 168 Red Oxide 169 Aluminium Paint 170 Cement bottoming 1:2:4 mix as per REC standards .45cum /pole 171 Aluminium Jointing Sleeves 172 Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

Key Value

Document Fees
INR 4000 /-
EMD
INR 782000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy