Tender For Rate Contract For Repair And Maintenance Of Electrical Installation At Irel,Red

Issued by Boards / Undertakings / PSU · udyogamandal, Kerala
Tender Value
65.50 Lakhs
Estimated cost
Bid Submission
27 Oct 2025
0 days left
EMD
1.11 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
udyogamandal → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Rate Contract For Repair And Maintenance Of Electrical Installation At Irel,Red; 1 Replacing of inspection lamp bulb and holder. Details as per sl No 1.1 in BOQ 2 Replacement of tube light fittings.Details as per sl No 1.2 in BOQ 3 Replacement of switches/MCBs for light fittings. Details as per sl No 1.3 in BOQ 4 Installation and charging of new light points (include wiring (maximum of 10mtr.), providing switches, fixing light fittings supports and light fitting etc.). Details as per sl No 1.4 in BOQ 5 Replacement of Street light fittings.Details as per sl No 1.5 in BOQ 6 Installation and charging of new street light points (includes wiring (maximum of 10mtr.), providing switches, fixing light fittings supports and light fitting etc.).Details as per sl No 1.6 in BOQ 7 Repair of light fittings (Tube light, HPMV, HPSV, CFL, LED, MH etc.). Details as per sl No 1.7 in BOQ 8 Removal of Ceiling fan, wall mounting fans, pedestal fans etc..Details as per sl No 2.1 in BOQ 9 Repair of Ceiling fan, wall mounting fans, pedestal fans.Details as per sl No 2.2 in BOQ 10 Replacement of Ceiling fan, wall mounting fans, pedestal fans. Details as per sl No 2.3 in BOQ 11 Installation and charging of new Ceiling fan/wall mounting fans/ pedestal fans etc. Details as per sl No 2.4 in BOQ 12 Repair of exhaust fans of different capacity. Details as per sl No 2.5 in BOQ 13 Replacement of exhaust fans of different capacity.Details as per sl No 2.6 in BOQ 14 Installation and charging of new exhaust fans of different capacity (includes wiring (maximum of 10mtr.), providing switches etc. Details as per sl No 2.7 in BOQ 15 Repair of Tube axial fans/Air circulator/ Man cooler etc. Details as per sl No 2.8 in BOQ 16 Replacement of Air circulator Man cooler etc. Details as per sl No 2.9 in BOQ 17 Installation and charging of new Air circulator Man cooler (includes wiring (maximum of 10mtr.), providing switches etc. Details as per sl No 2.10 in BOQ 18 Air Blowing, cleaning and servicing of PCC/MCC panels.While cleaning any of the damaged component noticed, shall be replaced by contractor (All required spares shall be issued by IREL). Details as per sl No 3 in BOQ 19 Air Blowing, cleaning and servicing of Main Switches, Starters, DBs’ While cleaning any of the damaged component noticed, shall be replaced by contractor (All required spares shall be issued by IREL). Details as per sl No 4 in BOQ 20 Replacement of contactors.Details as per sl No 5.1 in BOQ 21 Replacement of over load relay. Details as per sl No 5.2 in BOQ 22 Replacement of DOL starter. Details as per sl No 5.3 in BOQ 23 Repair of DOL starter. Details as per sl No 5.4 in BOQ 24 Installation and charging of DOL starter.Details as per sl No 5.5 in BOQ 25 Replacement of contactors. Details as per sl No 6.1 in BOQ 26 Replacement of over load relay. Details as per sl No 6.2 in BOQ 27 Replacement of star delta timer. Details as per sl No 6.3 in BOQ 28 Replacement of Star Delta Starter. Details as per sl No 6.4 in BOQ 29 Repair of Star Delta starter. Details as per sl No 6.5 in BOQ 30 Installation and charging of Star Delta starter. Details as per sl No 6.6 in BOQ 31 Repair/replacement of remote switch station. Details as per sl No 7 in BOQ 32 Installation and charging of remote switch station.Details as per sl No 8 in BOQ 33 Repair/replacement of float switch control station. Details as per sl No 9 in BOQ 34 Replacement of float switch. Details as per sl No 10 in BOQ 35 Installation and charging of float switch control station & float switch (including its cabling). Details as per sl No 11 in BOQ 36 Repair/replacement of Drives and its programming. Details as per sl No 12 in BOQ 37 Repair/replacement of Lighting DBs. Details as per sl No 13 in BOQ 38 Installation and charging of New Lighting DB (Includes cabling, termination, earthing etc. Details as per sl No 14 in BOQ 39 Repair/replacement of Power DBs’. Details as per sl No 15 in BOQ 40 Installation and charging of New Power DB (Includes cabling, termination, earthing etc. Details as per sl No 16 in BOQ 41 32A to 160A. Details as per sl No 17.1 in BOQ 42 200A to 400A. Details as per sl No 17.2 in BOQ 43 Replacement of HRC Fuses. Details as per sl No 18 in BOQ 44 Removal fuse/ isolation of power from electro-mechanical machinery for maintenance work. Details as per sl No 19 in BOQ 45 Re-positioning fuse to circuit / charging the isolated power from the electro-mechanical machinery after maintenance work. Details as per sl No 20 in BOQ 46 Installation/Replacement/Repair of MCB/MPCB. Details as per sl No 21 in BOQ 47 32A to 160A. Details as per sl No 22.1 in BOQ 48 200A to 400A.Details as per sl No 22.2 in BOQ 49 630A and above. Details as per sl No 22.3 in BOQ 50 0.5 HP to 7.5HP.Details as per sl No 23.1 in BOQ 51 10HP to 30HP. Details as per sl No 23.2 in BOQ 52 40Hp to 50HP. Details as per sl No 23.3 in BOQ 53 0.5 HP to 7.5HP. Details as per sl No 24.1 in BOQ 54 10HP to 30HP. Details as per sl No 24.2 in BOQ 55 40Hp to 50HP. Details as per sl No 24.3 in BOQ 56 0.5 HP to 7.5HP. Details as per sl No 25.1 in BOQ 57 10HP to 30HP. Details as per sl No 25.2 in BOQ 58 40Hp to 50HP.Details as per sl No 25.3 in BOQ 59 0.5 HP to 7.5HP. Details as per Sl No 26.1 in BOQ 60 10HP to 30HP.Details as per Sl No 26.2 in BOQ 61 40Hp to 50HP.Details as per Sl No 26.3 in BOQ 62 0.5 HP to 7.5HP. Details as per Sl No 27.1 in BOQ 63 10HP to 30HP.Details as per Sl No 27.2 in BOQ 64 40Hp to 50HP.Details as per Sl No 27.3 in BOQ 65 Checking the conditions of heating coils & switch gears for the furnace/calciner. Details as per Sl No 28 in BOQ 66 Cleaning, lubricating, and checking of hooks, clamps, Nuts& bolts, wire rope, chain and replacement (if required) of electric hoist. Details as per Sl No 29 in BOQ 67 Repair the control circuit of the electric hoist. Details as per Sl No 30 in BOQ 68 Removing of the unused/damaged cable, rolling out the cables, transport to salvage/scrap yard, after weighing, (with in 200mtr inside the company premises). Details as per Sl No 31 in BOQ 69 Removing of the unused/damaged cable trays, light fixers, starter and frames, MS structural materials etc., Details as per Sl No 32 in BOQ 70 Disconnect incomer and outgoing power cable from the Old/damaged PCC/MCC/ MCB-DB panel, Removing the Old/damaged PCC/MCC/ MCB-Band Transport it to salvage/scrape yard after weighing (within 200mtr inside the company premises).Details as per Sl No 33 in BOQ 71 Installation and commissioning of PCC/MCC panes by connecting all the incoming, & outgoing cables including earthing of the panels. Details as per Sl No 34 in BOQ 72 Up to 6 ways. Details as per Sl No 35.1 in BOQ 73 Up to 12 ways. Details as per Sl No 35.2 in BOQ 74 Up to 24 ways. Details as per Sl No 35.3 in BOQ 75 Fabrication, Painting, Installation of cable tray, cable tray support, street light supports, fixing frames for MCB-DB/starters/remote push station etc.Details as per Sl No 36 in BOQ 76 Installation of FRP cable tray. (FRP cable tray for the works shall be provided IREL, RED). Details as per Sl No 37 in BOQ 77 Cable size (Cu) 1.5Sq.mm/2.5Sq.mm/4Sq.mm Details as per Sl No 38.1 in BOQ 78 Cable size (Cu) 6Sq.mm/ OR (Al)16Sq.mm. Details as per Sl No 38.2 in BOQ 79 Cable size (Al) 25Sq.mm/35Sq.mm. Details as per Sl No 38.3 in BOQ 80 Cable size (Al) 50Sq.mm/70Sq.mm. Details as per Sl No 38.4 in BOQ 81 Cable size (Al) 95Sq.mm/120Sq.mm. Details as per Sl No 38.5 in BOQ 82 Cable size (Al) 150Sq.mm/185Sq.mm. Details as per Sl No 38.6 in BOQ 83 Cable size (Al) 240Sq.mm/300Sq.mm. Details as per Sl No 38.7 in BOQ 84 Cable size (Al) 400Sq.mm. Details as per Sl No 38.8 in BOQ 85 Cable size (Cu) 1.5Sq.mm/2.5Sq.mm/4Sq.mm. Details as per Sl No 39.1 in BOQ 86 Cable size (Cu) 6Sq.mm/ OR (Al)16Sq.mm. Details as per Sl No 39.2 in BOQ 87 Cable size (Al) 25Sq.mm/35Sq.mm. Details as per Sl No 39.3 in BOQ 88 Cable size (Al) 50Sq.mm/70Sq.mm. Details as per Sl No 39.4 in BOQ 89 Cable size (Al) 95Sq.mm/120Sq.mm. Details as per Sl No 39.5 in BOQ 90 Cable size (Al) 150Sq.mm/185Sq.mm. Details as per Sl No 39.6 in BOQ 91 Cable size (Al) 240Sq.mm/300Sq.mm. Details as per Sl No 39.7 in BOQ 92 Cable size (Al) 400Sq.mm. Details as per Sl No 39.8 in BOQ 93 Laying, dressing and termination of earth strip/earth wire to the earth points on panels, equipment, earth pits etc. Details as per Sl No 40 in BOQ 94 Measuring, labelling and providing earth pit resistance report for all earth pits.Details as per Sl No 41 in BOQ 95 Transformer Oil filtration and its associated oil checks (as per IS 1180:2014, IS 1866:2000, IS 1448:1997 with its amendments) and providing report for 500KVA, 11/0.415KV transformers. Details as per Sl No 42 in BOQ 96 Supply, fabrication and installation of cable trays, cable tray supports, light fixing supports, DB fixing frames etc.Details as per Sl No 43 in BOQ 97 Painting ofcable trays, cable tray supports, light fixing supports, DB fixing frames, PCC/MCC panels, PDBs, LDBs starters etc. Details as per Sl No 44 in BOQ 98 Additional charges for attending back shift breakdown work attending on emergency call basis per team of Supervisor and Electrician. Details as per Sl No 45 in BOQ

BOQ

Name of Work:
Sl. No. Item Description
1Replacing of inspection lamp bulb and holder. Details as per sl No 1.1 in BOQ
2Replacement of tube light fittings.Details as per sl No 1.2 in BOQ
3Replacement of switches/MCBs for light fittings. Details as per sl No 1.3 in BOQ
4Installation and charging of new light points (include wiring (maximum of 10mtr.), providing switches, fixing light fittings supports and light fitting etc.). Details as per sl No 1.4 in BOQ
5Replacement of Street light fittings.Details as per sl No 1.5 in BOQ
6Installation and charging of new street light points (includes wiring (maximum of 10mtr.), providing switches, fixing light fittings supports and light fitting etc.).Details as per sl No 1.6 in BOQ
7Repair of light fittings (Tube light, HPMV, HPSV, CFL, LED, MH etc.). Details as per sl No 1.7 in BOQ
8Removal of Ceiling fan, wall mounting fans, pedestal fans etc..Details as per sl No 2.1 in BOQ
9Repair of Ceiling fan, wall mounting fans, pedestal fans.Details as per sl No 2.2 in BOQ
10Replacement of Ceiling fan, wall mounting fans, pedestal fans. Details as per sl No 2.3 in BOQ
11Installation and charging of new Ceiling fan/wall mounting fans/ pedestal fans etc. Details as per sl No 2.4 in BOQ
12Repair of exhaust fans of different capacity. Details as per sl No 2.5 in BOQ
13Replacement of exhaust fans of different capacity.Details as per sl No 2.6 in BOQ
14Installation and charging of new exhaust fans of different capacity (includes wiring (maximum of 10mtr.), providing switches etc. Details as per sl No 2.7 in BOQ
15Repair of Tube axial fans/Air circulator/ Man cooler etc. Details as per sl No 2.8 in BOQ
16Replacement of Air circulator Man cooler etc. Details as per sl No 2.9 in BOQ
17Installation and charging of new Air circulator Man cooler (includes wiring (maximum of 10mtr.), providing switches etc. Details as per sl No 2.10 in BOQ
18Air Blowing, cleaning and servicing of PCC/MCC panels.While cleaning any of the damaged component noticed, shall be replaced by contractor (All required spares shall be issued by IREL). Details as per sl No 3 in BOQ
19Air Blowing, cleaning and servicing of Main Switches, Starters, DBs’ While cleaning any of the damaged component noticed, shall be replaced by contractor (All required spares shall be issued by IREL). Details as per sl No 4 in BOQ
20Replacement of contactors.Details as per sl No 5.1 in BOQ
21Replacement of over load relay. Details as per sl No 5.2 in BOQ
22Replacement of DOL starter. Details as per sl No 5.3 in BOQ
23Repair of DOL starter. Details as per sl No 5.4 in BOQ
24Installation and charging of DOL starter.Details as per sl No 5.5 in BOQ
25Replacement of contactors. Details as per sl No 6.1 in BOQ
26Replacement of over load relay. Details as per sl No 6.2 in BOQ
27Replacement of star delta timer. Details as per sl No 6.3 in BOQ
28Replacement of Star Delta Starter. Details as per sl No 6.4 in BOQ
29Repair of Star Delta starter. Details as per sl No 6.5 in BOQ
30Installation and charging of Star Delta starter. Details as per sl No 6.6 in BOQ
31Repair/replacement of remote switch station. Details as per sl No 7 in BOQ
32Installation and charging of remote switch station.Details as per sl No 8 in BOQ
33Repair/replacement of float switch control station. Details as per sl No 9 in BOQ
34Replacement of float switch. Details as per sl No 10 in BOQ
35Installation and charging of float switch control station & float switch (including its cabling). Details as per sl No 11 in BOQ
36Repair/replacement of Drives and its programming. Details as per sl No 12 in BOQ
37Repair/replacement of Lighting DBs. Details as per sl No 13 in BOQ
38Installation and charging of New Lighting DB (Includes cabling, termination, earthing etc. Details as per sl No 14 in BOQ
39Repair/replacement of Power DBs’. Details as per sl No 15 in BOQ
40Installation and charging of New Power DB (Includes cabling, termination, earthing etc. Details as per sl No 16 in BOQ
4132A to 160A. Details as per sl No 17.1 in BOQ
42200A to 400A. Details as per sl No 17.2 in BOQ
43Replacement of HRC Fuses. Details as per sl No 18 in BOQ
44Removal fuse/ isolation of power from electro-mechanical machinery for maintenance work. Details as per sl No 19 in BOQ
45Re-positioning fuse to circuit / charging the isolated power from the electro-mechanical machinery after maintenance work. Details as per sl No 20 in BOQ
46Installation/Replacement/Repair of MCB/MPCB. Details as per sl No 21 in BOQ
4732A to 160A. Details as per sl No 22.1 in BOQ
48200A to 400A.Details as per sl No 22.2 in BOQ
49630A and above. Details as per sl No 22.3 in BOQ
500.5 HP to 7.5HP.Details as per sl No 23.1 in BOQ
5110HP to 30HP. Details as per sl No 23.2 in BOQ
5240Hp to 50HP. Details as per sl No 23.3 in BOQ
530.5 HP to 7.5HP. Details as per sl No 24.1 in BOQ
5410HP to 30HP. Details as per sl No 24.2 in BOQ
5540Hp to 50HP. Details as per sl No 24.3 in BOQ
560.5 HP to 7.5HP. Details as per sl No 25.1 in BOQ
5710HP to 30HP. Details as per sl No 25.2 in BOQ
5840Hp to 50HP.Details as per sl No 25.3 in BOQ
590.5 HP to 7.5HP. Details as per Sl No 26.1 in BOQ
6010HP to 30HP.Details as per Sl No 26.2 in BOQ
6140Hp to 50HP.Details as per Sl No 26.3 in BOQ
620.5 HP to 7.5HP. Details as per Sl No 27.1 in BOQ
6310HP to 30HP.Details as per Sl No 27.2 in BOQ
6440Hp to 50HP.Details as per Sl No 27.3 in BOQ
65Checking the conditions of heating coils & switch gears for the furnace/calciner. Details as per Sl No 28 in BOQ
66Cleaning, lubricating, and checking of hooks, clamps, Nuts& bolts, wire rope, chain and replacement (if required) of electric hoist. Details as per Sl No 29 in BOQ
67Repair the control circuit of the electric hoist. Details as per Sl No 30 in BOQ
68Removing of the unused/damaged cable, rolling out the cables, transport to salvage/scrap yard, after weighing, (with in 200mtr inside the company premises). Details as per Sl No 31 in BOQ
69Removing of the unused/damaged cable trays, light fixers, starter and frames, MS structural materials etc., Details as per Sl No 32 in BOQ
70Disconnect incomer and outgoing power cable from the Old/damaged PCC/MCC/ MCB-DB panel, Removing the Old/damaged PCC/MCC/ MCB-Band Transport it to salvage/scrape yard after weighing (within 200mtr inside the company premises).Details as per Sl No 33 in BOQ
71Installation and commissioning of PCC/MCC panes by connecting all the incoming, & outgoing cables including earthing of the panels. Details as per Sl No 34 in BOQ
72Up to 6 ways. Details as per Sl No 35.1 in BOQ
73Up to 12 ways. Details as per Sl No 35.2 in BOQ
74Up to 24 ways. Details as per Sl No 35.3 in BOQ
75Fabrication, Painting, Installation of cable tray, cable tray support, street light supports, fixing frames for MCB-DB/starters/remote push station etc.Details as per Sl No 36 in BOQ
76Installation of FRP cable tray. (FRP cable tray for the works shall be provided IREL, RED). Details as per Sl No 37 in BOQ
77Cable size (Cu) 1.5Sq.mm/2.5Sq.mm/4Sq.mm Details as per Sl No 38.1 in BOQ
78Cable size (Cu) 6Sq.mm/ OR (Al)16Sq.mm. Details as per Sl No 38.2 in BOQ
79Cable size (Al) 25Sq.mm/35Sq.mm. Details as per Sl No 38.3 in BOQ
80Cable size (Al) 50Sq.mm/70Sq.mm. Details as per Sl No 38.4 in BOQ
81Cable size (Al) 95Sq.mm/120Sq.mm. Details as per Sl No 38.5 in BOQ
82Cable size (Al) 150Sq.mm/185Sq.mm. Details as per Sl No 38.6 in BOQ
83Cable size (Al) 240Sq.mm/300Sq.mm. Details as per Sl No 38.7 in BOQ
84Cable size (Al) 400Sq.mm. Details as per Sl No 38.8 in BOQ
85Cable size (Cu) 1.5Sq.mm/2.5Sq.mm/4Sq.mm. Details as per Sl No 39.1 in BOQ
86Cable size (Cu) 6Sq.mm/ OR (Al)16Sq.mm. Details as per Sl No 39.2 in BOQ
87Cable size (Al) 25Sq.mm/35Sq.mm. Details as per Sl No 39.3 in BOQ
88Cable size (Al) 50Sq.mm/70Sq.mm. Details as per Sl No 39.4 in BOQ
89Cable size (Al) 95Sq.mm/120Sq.mm. Details as per Sl No 39.5 in BOQ
90Cable size (Al) 150Sq.mm/185Sq.mm. Details as per Sl No 39.6 in BOQ
91Cable size (Al) 240Sq.mm/300Sq.mm. Details as per Sl No 39.7 in BOQ
92Cable size (Al) 400Sq.mm. Details as per Sl No 39.8 in BOQ
93Laying, dressing and termination of earth strip/earth wire to the earth points on panels, equipment, earth pits etc. Details as per Sl No 40 in BOQ
94Measuring, labelling and providing earth pit resistance report for all earth pits.Details as per Sl No 41 in BOQ
95Transformer Oil filtration and its associated oil checks (as per IS 1180:2014, IS 1866:2000, IS 1448:1997 with its amendments) and providing report for 500KVA, 11/0.415KV transformers. Details as per Sl No 42 in BOQ
96Supply, fabrication and installation of cable trays, cable tray supports, light fixing supports, DB fixing frames etc.Details as per Sl No 43 in BOQ
97Painting ofcable trays, cable tray supports, light fixing supports, DB fixing frames, PCC/MCC panels, PDBs, LDBs starters etc. Details as per Sl No 44 in BOQ
98Additional charges for attending back shift breakdown work attending on emergency call basis per team of Supervisor and Electrician. Details as per Sl No 45 in BOQ

AI Tender Summary

OUR REF NO 51751659
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 65.50 Lakhs
LAST DATE 27-10-2025
Authority
Authority Name Indian Rare Earths Limited
Work Description Tender For Rate Contract For Repair And Maintenance Of Electrical Installation At Irel,Red; 1 Replacing of inspection lamp bulb and holder. Details as per sl No 1.1 in BOQ 2 Replacement of tube light fittings.Details as per sl No 1.2 in BOQ 3 Replacement of switches/MCBs for light fittings. Details as per sl No 1.3 in BOQ 4 Installation and charging of new light points (include wiring (maximum of 10mtr.), providing switches, fixing light fittings supports and light fitting etc.). Details as per sl No 1.4 in BOQ 5 Replacement of Street light fittings.Details as per sl No 1.5 in BOQ 6 Installation and charging of new street light points (includes wiring (maximum of 10mtr.), providing switches, fixing light fittings supports and light fitting etc.).Details as per sl No 1.6 in BOQ 7 Repair of light fittings (Tube light, HPMV, HPSV, CFL, LED, MH etc.). Details as per sl No 1.7 in BOQ 8 Removal of Ceiling fan, wall mounting fans, pedestal fans etc..Details as per sl No 2.1 in BOQ 9 Repair of Ceiling fan, wall mounting fans, pedestal fans.Details as per sl No 2.2 in BOQ 10 Replacement of Ceiling fan, wall mounting fans, pedestal fans. Details as per sl No 2.3 in BOQ 11 Installation and charging of new Ceiling fan/wall mounting fans/ pedestal fans etc. Details as per sl No 2.4 in BOQ 12 Repair of exhaust fans of different capacity. Details as per sl No 2.5 in BOQ 13 Replacement of exhaust fans of different capacity.Details as per sl No 2.6 in BOQ 14 Installation and charging of new exhaust fans of different capacity (includes wiring (maximum of 10mtr.), providing switches etc. Details as per sl No 2.7 in BOQ 15 Repair of Tube axial fans/Air circulator/ Man cooler etc. Details as per sl No 2.8 in BOQ 16 Replacement of Air circulator Man cooler etc. Details as per sl No 2.9 in BOQ 17 Installation and charging of new Air circulator Man cooler (includes wiring (maximum of 10mtr.), providing switches etc. Details as per sl No 2.10 in BOQ 18 Air Blowing, cleaning and servicing of PCC/MCC panels.While cleaning any of the damaged component noticed, shall be replaced by contractor (All required spares shall be issued by IREL). Details as per sl No 3 in BOQ 19 Air Blowing, cleaning and servicing of Main Switches, Starters, DBs’ While cleaning any of the damaged component noticed, shall be replaced by contractor (All required spares shall be issued by IREL). Details as per sl No 4 in BOQ 20 Replacement of contactors.Details as per sl No 5.1 in BOQ 21 Replacement of over load relay. Details as per sl No 5.2 in BOQ 22 Replacement of DOL starter. Details as per sl No 5.3 in BOQ 23 Repair of DOL starter. Details as per sl No 5.4 in BOQ 24 Installation and charging of DOL starter.Details as per sl No 5.5 in BOQ 25 Replacement of contactors. Details as per sl No 6.1 in BOQ 26 Replacement of over load relay. Details as per sl No 6.2 in BOQ 27 Replacement of star delta timer. Details as per sl No 6.3 in BOQ 28 Replacement of Star Delta Starter. Details as per sl No 6.4 in BOQ 29 Repair of Star Delta starter. Details as per sl No 6.5 in BOQ 30 Installation and charging of Star Delta starter. Details as per sl No 6.6 in BOQ 31 Repair/replacement of remote switch station. Details as per sl No 7 in BOQ 32 Installation and charging of remote switch station.Details as per sl No 8 in BOQ 33 Repair/replacement of float switch control station. Details as per sl No 9 in BOQ 34 Replacement of float switch. Details as per sl No 10 in BOQ 35 Installation and charging of float switch control station & float switch (including its cabling). Details as per sl No 11 in BOQ 36 Repair/replacement of Drives and its programming. Details as per sl No 12 in BOQ 37 Repair/replacement of Lighting DBs. Details as per sl No 13 in BOQ 38 Installation and charging of New Lighting DB (Includes cabling, termination, earthing etc. Details as per sl No 14 in BOQ 39 Repair/replacement of Power DBs’. Details as per sl No 15 in BOQ 40 Installation and charging of New Power DB (Includes cabling, termination, earthing etc. Details as per sl No 16 in BOQ 41 32A to 160A. Details as per sl No 17.1 in BOQ 42 200A to 400A. Details as per sl No 17.2 in BOQ 43 Replacement of HRC Fuses. Details as per sl No 18 in BOQ 44 Removal fuse/ isolation of power from electro-mechanical machinery for maintenance work. Details as per sl No 19 in BOQ 45 Re-positioning fuse to circuit / charging the isolated power from the electro-mechanical machinery after maintenance work. Details as per sl No 20 in BOQ 46 Installation/Replacement/Repair of MCB/MPCB. Details as per sl No 21 in BOQ 47 32A to 160A. Details as per sl No 22.1 in BOQ 48 200A to 400A.Details as per sl No 22.2 in BOQ 49 630A and above. Details as per sl No 22.3 in BOQ 50 0.5 HP to 7.5HP.Details as per sl No 23.1 in BOQ 51 10HP to 30HP. Details as per sl No 23.2 in BOQ 52 40Hp to 50HP. Details as per sl No 23.3 in BOQ 53 0.5 HP to 7.5HP. Details as per sl No 24.1 in BOQ 54 10HP to 30HP. Details as per sl No 24.2 in BOQ 55 40Hp to 50HP. Details as per sl No 24.3 in BOQ 56 0.5 HP to 7.5HP. Details as per sl No 25.1 in BOQ 57 10HP to 30HP. Details as per sl No 25.2 in BOQ 58 40Hp to 50HP.Details as per sl No 25.3 in BOQ 59 0.5 HP to 7.5HP. Details as per Sl No 26.1 in BOQ 60 10HP to 30HP.Details as per Sl No 26.2 in BOQ 61 40Hp to 50HP.Details as per Sl No 26.3 in BOQ 62 0.5 HP to 7.5HP. Details as per Sl No 27.1 in BOQ 63 10HP to 30HP.Details as per Sl No 27.2 in BOQ 64 40Hp to 50HP.Details as per Sl No 27.3 in BOQ 65 Checking the conditions of heating coils & switch gears for the furnace/calciner. Details as per Sl No 28 in BOQ 66 Cleaning, lubricating, and checking of hooks, clamps, Nuts& bolts, wire rope, chain and replacement (if required) of electric hoist. Details as per Sl No 29 in BOQ 67 Repair the control circuit of the electric hoist. Details as per Sl No 30 in BOQ 68 Removing of the unused/damaged cable, rolling out the cables, transport to salvage/scrap yard, after weighing, (with in 200mtr inside the company premises). Details as per Sl No 31 in BOQ 69 Removing of the unused/damaged cable trays, light fixers, starter and frames, MS structural materials etc., Details as per Sl No 32 in BOQ 70 Disconnect incomer and outgoing power cable from the Old/damaged PCC/MCC/ MCB-DB panel, Removing the Old/damaged PCC/MCC/ MCB-Band Transport it to salvage/scrape yard after weighing (within 200mtr inside the company premises).Details as per Sl No 33 in BOQ 71 Installation and commissioning of PCC/MCC panes by connecting all the incoming, & outgoing cables including earthing of the panels. Details as per Sl No 34 in BOQ 72 Up to 6 ways. Details as per Sl No 35.1 in BOQ 73 Up to 12 ways. Details as per Sl No 35.2 in BOQ 74 Up to 24 ways. Details as per Sl No 35.3 in BOQ 75 Fabrication, Painting, Installation of cable tray, cable tray support, street light supports, fixing frames for MCB-DB/starters/remote push station etc.Details as per Sl No 36 in BOQ 76 Installation of FRP cable tray. (FRP cable tray for the works shall be provided IREL, RED). Details as per Sl No 37 in BOQ 77 Cable size (Cu) 1.5Sq.mm/2.5Sq.mm/4Sq.mm Details as per Sl No 38.1 in BOQ 78 Cable size (Cu) 6Sq.mm/ OR (Al)16Sq.mm. Details as per Sl No 38.2 in BOQ 79 Cable size (Al) 25Sq.mm/35Sq.mm. Details as per Sl No 38.3 in BOQ 80 Cable size (Al) 50Sq.mm/70Sq.mm. Details as per Sl No 38.4 in BOQ 81 Cable size (Al) 95Sq.mm/120Sq.mm. Details as per Sl No 38.5 in BOQ 82 Cable size (Al) 150Sq.mm/185Sq.mm. Details as per Sl No 38.6 in BOQ 83 Cable size (Al) 240Sq.mm/300Sq.mm. Details as per Sl No 38.7 in BOQ 84 Cable size (Al) 400Sq.mm. Details as per Sl No 38.8 in BOQ 85 Cable size (Cu) 1.5Sq.mm/2.5Sq.mm/4Sq.mm. Details as per Sl No 39.1 in BOQ 86 Cable size (Cu) 6Sq.mm/ OR (Al)16Sq.mm. Details as per Sl No 39.2 in BOQ 87 Cable size (Al) 25Sq.mm/35Sq.mm. Details as per Sl No 39.3 in BOQ 88 Cable size (Al) 50Sq.mm/70Sq.mm. Details as per Sl No 39.4 in BOQ 89 Cable size (Al) 95Sq.mm/120Sq.mm. Details as per Sl No 39.5 in BOQ 90 Cable size (Al) 150Sq.mm/185Sq.mm. Details as per Sl No 39.6 in BOQ 91 Cable size (Al) 240Sq.mm/300Sq.mm. Details as per Sl No 39.7 in BOQ 92 Cable size (Al) 400Sq.mm. Details as per Sl No 39.8 in BOQ 93 Laying, dressing and termination of earth strip/earth wire to the earth points on panels, equipment, earth pits etc. Details as per Sl No 40 in BOQ 94 Measuring, labelling and providing earth pit resistance report for all earth pits.Details as per Sl No 41 in BOQ 95 Transformer Oil filtration and its associated oil checks (as per IS 1180:2014, IS 1866:2000, IS 1448:1997 with its amendments) and providing report for 500KVA, 11/0.415KV transformers. Details as per Sl No 42 in BOQ 96 Supply, fabrication and installation of cable trays, cable tray supports, light fixing supports, DB fixing frames etc.Details as per Sl No 43 in BOQ 97 Painting ofcable trays, cable tray supports, light fixing supports, DB fixing frames, PCC/MCC panels, PDBs, LDBs starters etc. Details as per Sl No 44 in BOQ 98 Additional charges for attending back shift breakdown work attending on emergency call basis per team of Supervisor and Electrician. Details as per Sl No 45 in BOQ
Basic Detail
Tender No IREL/Udyogamandal/25-26/ 36117
Bidding Type Tender
Location
City udyogamandal
State Kerala
Key Dates
Publish Date 13 Oct 2025
Submission Date 27 Oct 2025
Open Date 28 Oct 2025
Finance
Tender Value 65.50 Lakhs
Tender Fee Ref. Documents
EMD 1.11 Lakhs
Exemption Available
Document List
66006d6f-fb68-4173-a6c3-2cfcaecb55f5.html
BOQ_289518.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 13, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 27, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 28, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

66006d6f-fb68-4173-a6c3-2cfcaecb55f5.html

xls

BOQ_289518.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders