Tender For Comprehensive Maintenance Of Internal Electrification E M Works Including Fan Geyser Welcome Maintenance And Misc Works At Md Accommodation At Si Lines Under Ge Bhopal.; 2 Dismantling of ceiling fans, single phase, 230 volts AC of 1200 mm/ 1400 mm sweep of any make / model except of old vintage fans, dismantling its stator, rotor, cutting out burnt copper winding and providing new winding with super enamelled copper winding wire of existing gauge including cleaning of slots and providing oil impregnated insulation paper or minimax, fibre, insulation in slots and well wraping with cotton tape, binding with cotton thread and varnishing over all with winding varnish, cleaning of bearing, housing and shaft, replacing minor spare parts such as split pins, blade screws etc as required and re-assembling and depositing the repaired fan to MES store yard after testing complete all as specified and directed. 3 All as per item No. 1.00 here in before but exhaust fan, 400/ 450 mm sweep, single phase, 230/240 volts AC. 4 All as per item No. 1.00 here in before but exhaust fan, 300/ 380 mm sweep, single phase, 230/240 volts AC. 5 All as per item No. 1.00 here in before but exhaust fan, 230/ 250 mm sweep, single phase, 230/240 volts AC. 6 All as per item No. 1.00here in before but wall / pedestal fan, of any sweep and capacity, single phase, 230/240 volts AC.Notes for item no 1 to 5:- (i) The quoted rate deems to include for all minor repairs required for making the complaint functional.(ii) Repairing/ rewinding of ceilling fan/ exhaust fan shall be carried out in the SI Line E/M yard in present of concern JE E/M and winding wire sample produced for sample before winding work start.(iii) Contractor staff will collect defective fans from concern JE E/M for checking the fans and after opening it, defects will be intimated to JE E/M before repairing.(iv) Bearing of fan shall be measured and paid seperately. 7 Dismantling of BLDC ceiling fans (with/ without remote control) of sizes 1200mm/ 1400mm sweep of any make / model except old vintage fans, dismantling its stator, rotor, taking out burnt PCB and providing new PCB, 35-40 W, AC single phase, 230 volts of existing size including cleaning of slots, cleaning of bearing, housing, shaft and replacing spares such as split pins, blade screws etc as required and reassembling and depositing the repaired fan to MES store yard after testing complete all as specified and directed. 8 S&F in replacement of LED slim square/ circular panel light fitting for surface ceiling light, 12 watts, colour warm white including making connection with 3 core, 23/0.0076 copper insulated cable from celing rose to fittting connector complete all as specified and directed. 9 S&F in replacement condenser carrier clip (PVC) in build connector two way fixed with screwon down rod or housing complete all as specified and directed. 10 S&F in replacement upper set of clips for down rod with rubber bush (Garari) including set of nut, bolt, washer and split pin complete all as specified and directed. 11 S&F in replacement rubber bush (Garari) for mounting at upper side of down rod complete all as specified and directed 12 S&F in replacement gun metal bush, self lubricated, any size, suitable for ceiling and wall fans complete all as specified and directed 13 S&F in replacement flexible copper conductor stranded1100 VoltPVC insulated cable, three core, 23/0.0076 size complete all as specified and directed. 14 S&F in replacement fan condenser 2.5 mfd, 230 volts complete all as specified and directed. 15 S&F in replacement fan condenser 3.15 mfd, 230 volts complete all as specified and directed. 16 S&F in replacement fan condenser 4.0 mfd, 230 volts complete all as specified and directed. 17 S&F of bearing No. 6201 ZZ of fan complete all as specified and directed. 18 S&F of bearing No. 6202 ZZ of fan complete all as specified and directed. 19 S&F of bearing No. 6203 ZZ of fan complete all as specified and directed. 20 S&F of bearing No. 6204 ZZ of fan complete all as specified and directed. 21 Taking down ceiling / wall fan from fan hook after disconnecting from ceiling rose including dismantling of fan parts i.e. down rod and connector/ condenser, nut, bolts, split pins, rubber bush (garari), condenser carrier clip (PVC), in build connector two way, etc. complete with and incluidng servicing the same by cleaning, greasing/oiling in side surface of rotar by CTC with sand paper and repair and re-fitting / reassembling and making the fan fuctional and fixing the fan in position after testing complete all as specified and directed. Note:- Defective rubber packing (garari), condenser, condenser carrier clip (PVC), in build connector two way shall be measured and paid separately. 22 Taking down exhaust fan after disconnecting from ceiling rose including dismantling of fan parts i e. connector/ condenser, nuts, bolts, condenser carrier clip (PVC), in build connector two way, etc. complete with and incluidng servicing by cleaning, greasing/oiling in side surface of rotar by CTC with sand paper and repair and re-fitting / reassembling and making the fan fuctional and fixing the fan in position after testing complete all as specified and directed. Note:- defective rubber packing (garari), condenser, condenser carrier clip (PVC), in build connector two way shall be measured and paid separately. 23 S&F in replacement down rod for ceiling fans duly painted with synthetic enamelled paint, 300 mm long & 19 mm outer dia with holes on both ends of the rod for connection wire complete all as specified and directed. 24 S&F in replacement down rod for ceiling fans duly painted with synthetic enamelled paint, 600 mm long & 19 mm outer dia with holes on both ends of the rod for connection wire complete all as specified and directed. 25 S&F in replacement exhaust fan metal blade duly powder coated suitable for 450 mm/380 mm sweep as per existing complete all as directed. 26 S&F in replacement exhaust fan metal blade duly powder coated suitable for 300 mm/230mm sweep as per existing complete all as directed. 27 S&F in replacement blade assembly of celling fan of 1200 mm sweep (set of three) of approved make, colour and pattern as per existing complete all as specified and directed. 28 S&F in replacement blade assembly of celling fan of 1400 mm sweep (set of three) of approved make, colour and pattern as per existing complete all as specified and directed. 29 S&F in repairs outer frame complete with clamps, rubber packing, nuts, bolts etc and all other connected accessories duly painted suitable for 450 mm/ 380 mm sweep exhaust fans complete all as specified and directed. 30 S&F in repairs top and bottom canopy of ceiling fan (any sweep) of approved make, colour and pattern as per existing model complete all as specified and directed 31 S&F in repairs outer frame complete with clamps, rubber packing, nut bolts etc and all other connected accessories duly painted suitable for 230 mm / 300 mm sweep exhaust fans complete all as specified and directed. 32 M&L for cleaning, washing and preparation of old painted surfaces of ceiling fan upto 1200/1400 mm sweep and applying painting with two coats of DUCO paint, white, using spray painting machine including writing MES Nos on ceiling and exhaust fans complete all as specified and directed.Note:- Taking down and fixing of fan will be measured seperately. 33 M&L for cleaning, washing and preparation of old painted surfaces of exhaust fan of 280/ 300/ 380/ 450 mm sweep and applying painting with two coats of DUCO paint, smoke grey, using spray painting machine including writing MES Nos on ceiling and exhaust fans complete all as specified and directed.Note:- Taking down and fixing of fan will be measured seperately. 34 S&F of ceiling fan regulator, electronic step type, 240 Volts, AC 50 Hz, single phase, 100 watts, flush type complete all as specified and directed. 35 Dismantling of cabin fan of any sweep and overhauling by means of cleaning of stator, oiling & greasing including replacement of nuts, bolt, etc and reassembling, re-fixing and testing the fan complete all as specified and directed. 36 Removing unserviceable fan bearing shaft (of any type & any sweep fans) and welding broken area of shaft including threading in lathe machine of appropriate size and refixing in ceiling fan, any type complete all as specified and directed. 37 Taking down unservicable sub main wiring including service connections, of any size and any description including conduit pipe and making good disturbed surface of walls/ ceiling to match with existing surface complete all as specified and directed . 38 M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with three, single core, PVC insulated FRLS cable 1100 V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section areaincluding PVC insulated stranded copper conductor of 6.0 sqmm nominal cross section area as earth wire including and drawing into 20 mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 complete all as specified and directed. Note:- Three runs of 6.0 sqmm cable & PVC conduit pipe shall be measured as one unit length. 39 M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with three, single core, PVC insulated FRLS cable 1100 V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section areaincluding PVC insulated stranded copper conductor of 4.0 sqmm nominal cross section area as earth wire including and drawing into 20 mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 complete all as specified and directed. Note:- Three runs of 6.0 sqmm cable & PVC conduit pipe shall be measured as one unit length. 40 Taking down carefully existing point wiring (any type and size) with wooden batten/ surface PVC conduit (with its fittings)/ PVC casing-capping or any other type of light, fan, power point (including switch, socket, ceiling rose, etc.) and making good disturbed surface of wall/ceiling to match with existing surface complete all as specified and directed. 41 M&L for concealed point wiring for one light or one fan or one exhaust fan controlled by one, one way switch complete with and including single core PVC insulated unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694:2010, ISI marked, annealed multistranded copper conductor drawn through and including medium grade PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site but not less than 20 mm noninal size including modular / non modular type all accessories/ fitting, metal flush box, junction boxes, inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multi stranded copper conductor FR-LSH cable as continious earth wire connected to metalic body at one end and common earth dolly to other end including cost ofcutting chases and making good to distrubed surfaces of wall in cement mortor 1: 3 including white wash / distemper/ other painting complete all as specified and directed. Note:- Cost of cutting chases andmaking good shall be included in the quoted rates. 42 All as per srl item No 40.00 here-in-before but for one switch socket combination, 5/6 Amp on independent board complete. 43 All as per srl item No 40.00 here-in-before but for one three pin socket outlet, 5 Amp on same board with other switches complete. 44 All as per srl item No 40.00 here-in-before but for one switch socket combination, 6 pin, 5/ 15 Amps on independent board with wire of size 2.5 Sqmm and 2.5 Sqmm as earth wire complete. 45 All as per srl item No 40.00 here-in-before but for one switch socket combination, 6 pin, 5/ 15 Amps on independent board with wire of size 4.0 Sqmm and 4.0 Sqmm as earth wire complete. 46 M&L for casing caping/ surface conduit point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated unsheathed flexible conductor FR-LS H cables 1.5 sqmm as per IS 694:2010, ISI marked, annealed multistranded copper conductor drawn through and including medium machenical strees PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm noninal size including modular / non modular type all accessories/ fitting, metal flush box, junction boxes, inspection cover etc ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multi stranded copper conductor FR-LSH cable as continious earth wire connected to metalic body at one end and common earth dolly to other end including cost ofcutting chases and making good to distrubed surfaces of wall in cement mortor 1: 3 including white wash / distemper/ other painting complete all as specified and directed. Note:- Cost of cutting chases andmaking good shall be included in the quoted rates. 47 All as per srl item No 45.00 here-in-before but for one switch socket combination, 5/6 Amp on independent board complete. 48 All as per srl item No 45.00 here-in-before but for one three pin socket outlet, 5 Amp on same board with other switches complete. 49 All as per srl item No 45.00 here-in-before but for one switch socket combination, 6 pin, 5/ 15 Amps on independent board with wire of size 2.5 Sqmm and 2.5 Sqmm as earth wire complete. 50 All as per srl item No 45.00 here-in-before but for one switch socket combination, 6 pin 5/ 15 Amps on independent board with wire of size 4.0 Sqmm and 4.0 Sqmm as earth wire complete. 51 S&F in replacement building security light fitting complete with 36 watt LED type, pressure die-cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution. fixed on bracket made out of GI pipe 32 mm dia (lightgrade) 1.2 metre long and MS clamps, nuts, bolts, washers and connected with twin core cable 1.5 sqmm from ceiling rose to fitting complete all as specified and directed. 52 S&F of switch piano, flush type, single pole, one way, 5/6 Amps, 230 volt AC complete all as specified and directed. 53 S&F of socket outlet multipurpose 2-in-1 having provision for 3 pin, 6 Amp, flush type,230 volt AC complete all as specified and directed. 54 S&F of switch socket combination, multipurpose, 3 pin, 5-15 Amp, flush type including PVC gang box,ISI marked complete all as specified and as directed. 55 Dismantling geyser of 25 ltrs capacity and of any description including M&L for cleaning and de-scaling the inner tank and other parts / accessories such as inlet, outlet, overflow, geyser element, thermostat, U assembly etc. with brush & cleaning rods and using & circulating concentrated de-scaling solution mixed with water in suitable proportion till the complete deposits/ scale is removed and brazing for stopping the leakage of copper inner tank by gas welding for stopping the leakage of inner steel tanks, fixing the serviceable parts in position, setting insulation properly as required, reassembling the complete geyser after cleaning, repairing, fixing and installating the geyser in position after testing complete all as specified and directed. Notes:- (i)De-scaling chemical shall be concentrated HCL of approved make.(ii)Painting of Geysers shall be measured and paid for separately under appropriate item of sch.(iii)Old disturbed insulation shall be made good by the contractor with using old retrieved glass wool and additional quantity of glass wool forinsulation, if any required, is deemed to be included in the quoted unit rate.(iv) Spares parts required shall be measured and paid seperately. 56 All as per item srl No. 54.00 here-in-before but geyser of capacity 50 Ltrs complete. 57 S&F of 1.5 KW capacity heating element (ISI marked) round type/ thread/ triangle/ push/ screw base type with ‘O’ ring including making electrical connections complete all as specified and directed. 58 S&F of 2.0 KW capacity heating element (ISI marked) round type/ thread/ triangle/ push/ screw base type with ‘O’ ring including making electrical connections complete all as specified and directed. 59 S&F of 1.5/ 2.0 KV electronic heating element (ISI marked) fitted with auto cut thermostat suitable for 25/ 50 ltrs geyser including making electrical connections complete all as specified and directed. 60 S&F in replacement SS geyser assembly suitable for 25 ltrs capacity, ISI marked complete all as specified and directed. 61 S&F in replacement SS geyser assembly suitable for 50 ltr capacity, ISI marked complete all as specified and directed. 62 S&F in replacement thermostat suitable for 25/ 50 Ltrs geysers (ISI marked) with setting range 30 to 80 degree centigrade, 230 volts AC electric supply complete all as specified and directed. 63 S&F in replacement inner tank made of stainless steel suitable for 25 Ltr geysers complete all as specified and directed. 64 S&F in replacement inner tank made of stainless steel suitable for 50 Ltr geysers complete all as specified and directed. 65 S&F in replacement outer tank made of steel sheet duly powder coated suitable for 25 Ltr geysers complete all as specified and directed. 66 S&F in replacement outer tank made of steel sheet duly powder coated suitable for 50 Ltr geysers complete all as specified and directed. 67 S&F in replacement mild steel bottom cover suitable for 25 Ltr geysers complete all as specified and directed. 68 S&F in replacement mild steel bottom cover suitable for 50 Ltr geysers complete all as specified and directed. 69 S&F in replacement indicating lamp (set of two), 230 volts, 50 HZ AC suitable for geyser any type (round, square or rectangular type) for any capacity geysers complete all as specified and directed. 70 M&L for cleaning, washing and preparation of old painted surfaces of 25 ltrs capacity geysers and applying painting with two coats of DUCO paint, white, using spray painting machine including writing MES Nos on ceiling and exhaust fans complete all as specified and directed. 71 M&L for cleaning, washing and preparation of old painted surfaces of 50 ltrs capacity geysers and applying painting with two coats of DUCO paint, white, using spray painting machine including writing MES Nos on ceiling and exhaust fans complete all as specified and directed. 72 S&F in replacement of single pole and neutral sheet metal enclosure with two pin and earth, plugand socket, single phase, 240 V with and including one No single pole MCB of capacity 20 Amps having `C` charactristic, breaking capacity 10 KA including industial plug top complete all as specified and directed. 73 S&F in replacementPVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed. 74 S&F in replacemntPVC connections 15 mm size with brass nuts, nylon braided, heavy duty, 600 mm long including rubber washers (suitable for hot water) complete all as specified and directed. 75 S&F in replacement of pressure release valve suitable for 25/ 50 Ltr capacity geysers complete all as specified and directed. 76 S&F in replacement PVC insulatedmultistranded copper conductor, 3 core of size 2.5 Sqmm, 1100 volts grade complete all as specified and directed. 77 S&F in replacement LED decorative aluminium casted edge ceiling light, recess mounting LED 2 x 2 luminaire, 36 watt with all accessories internally pre-wired and connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm, two core complete all as specified and directed. 78 S&F in replacement of warm white LED decorative aluminium casted edge ceiling light, recess mounting LED 2 x 2 luminaire 36 watt with all accessories internally pre-wired and connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core complete all as specified and directed. 79 S&F in replacement coral post top lantern fitting, 25 Watt, energy saving, environment friendly, long life aesthetically designed with symmetrical light distribution with accessories complete all as specified and directed. 80 S&F in replacement of LED tube light fitting, surface mounted luminanaires, 40 watt, 240 V, decorative ultra slim round/ square profile, LED lighting fixture with extruded polycarbonate body, environmental friendly, energy efficient with bipin holders, LED lamps, connector block, etc with all accessories, internally prewired and making connection with flexible copper conductor cable of suitable size complete all as specified and directed. 81 S&F in replacement of white LED tube light fitting, two feet, 10 watt, slim design, 230 volts including making connection with 3 core 23/0.0076 insulated copper wire from celing rose to fitting connector complete all as specified and directed. 82 S&F in replacement of warm LED tube light fitting, two feet, 10 watt, slim design, 230 volts including making connection with 3 core 23/0.0076 insulated copper wire from celing rose to fitting connector complete all as specified and directed. 83 S&F of PVC insulated unsheathed, FRLS copper cable, 1.5 Sqmm, 230 Volts AC complete all as specified and directed. 84 S&F of PVC insulated unsheathed, FRLS copper cable, 2.5 Sqmm, 230 Volts AC complete all as specified and directed. 85 S&F of modular switch, one way, 6 Amp, one module, 240 volts complete all as specified and directed. 86 S&F of modular switch, one way, 16 Amp, one module, 240 volts complete all as specified and directed. 87 S&F of modular bell push switch, one way, 6 Amp, one module, 240 volts complete all as specified and directed. 88 S&F of modular socket outlet, 2-in-1, 5 pin, 6 Amps, two module, 240 volts, controlled by one switch complete all as specified and directed. 89 S&F of modular socket outlet, 2-in-1, 2/3 pin, 6/16 Amps, two module, 240 volts, complete all as specified and directed. 90 S&F of modular switch socket combination, multipurpose, 6 pin, 16 Amp, 3 module, 240 Volts complete all as specified and directed. 91 S&F of modular fan regulator, electronic type, 5 step, high speed, 240 Volts complete all as specified and directed. 92 S&F of modular metal flush box of 12 module complete all as specified and directed. 93 S&F of modular metal flush box of 6 module complete all as specified and directed. 94 S&F of modular metal flush box of 4 module complete all as specified and directed. 95 S&F of modular white cover plate with frame of 12 module complete all as specified and directed. 96 S&F of modular white cover plate with frame of 6 module complete all as specified and directed. 97 S&F of modular white cover plate with frame of 4 module complete all as specified and directed. 98 Taking down old unserviceable MCCB/ MCB DB of any size and capacity including MCCB/ MCB with wooden boards complete all as specified and directed. 99 S&F of factory made sheet epoxy powder coated sheet metal enclosure for MCB, DB, TPN, 415 Volts, 200 Amps rated bus bar, 4 way, double door enclosure made up of CRCA sheet steel, RAL 9003, IP 54 protection over and including wooden rectangle board of first class hardwood of suitable size for mounting of DB box complete all as specified and as directed. Note:- MCB shall be measured and paid seperatly. 100 S&F of factory made epoxy powder coated distribution board TP & N, 4 way (VTPN MCCB DB) and space forMCCB as incomer with metal door (IP-54 protection) fabricated from CRCA sheet and fixed semi flush to wall with and including isolated neutral bar, insulated bus bar assembly, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts complete all as specified and directed.Note:- MCCB shall be measured and paid seperatly. 101 S&F of factory made sheet epoxy powder coated sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 Amps rated bus bar, 8 way, double door enclosure made up of CRCA sheet steel, RAL 9003, IP 54 protection concealed in wail suitable for incorporation MCBs and isolators etc complete all as specified and directed. Note:- MCB shall be measured and paid seperatly. 102 S&F of factory made sheet epoxy powder coated sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 Amps rated bus bar, 12 way, double door enclosure made up of CRCA sheet steel, RAL 9003, IP 54 protection concealed in wail suitable for incorporation MCBs and isolators etc complete all as specified and directed. Note:- MCB shall be measured and paid seperatly. 103 S&F of MCCB, 160 Amps, 3 Pole of breaking capacity 36 KA and making electricalconnections by appropriate size of copper lugs complete all as specified and directed. 104 S&F of MCB, SP, 6 to 32 Amps, 240 Volts, 10 KA breaking capacity, B curve and making connection with suitable size copper lugs complete all as specified and directed. 105 S&F of MCB, SP, 40 Amps, 240 Volts, 10 KA breaking capacity, B curve and making connection with suitable size copper lugs complete all as specified and directed. 106 S&F of MCB, SPN, 6 to 32 Amps, 240 Volts, B curve with over load and short circuit protection and rupturing capacity not less than 10 KA and making connection with suitable size copper lugs complete all as specified and directed. 107 S&F of MCB, SPN, 40 to 63 Amps, 240 Volts, B curve with over load and short circuit protection and rupturing capacity not less than 10 KA and making connection with suitable size copper lugs complete all as specified and directed. 108 S&F of MCB, TPN, 63 Amps, 240 Volts, B curve with over load and short circuit protection and rupturing capacity not less than 10 KA and making connection with suitable size copper lugs complete all as specified and directed. 109 S&F of MCB, TPN, 100 Amps, 240 Volts, B curve with over load and short circuit protection and rupturing capacity not less than 10 KA and making connection with suitable size copper lugs complete all as specified and directed. 110 S&F in replacement 3 pin plug top, AC-230 V, 15 Amps complete all as specified and directed. 111 S&F in replacement recess mounting spot LED light round downlighter designed with excellent thermally managed luminaire, 12 watt, 220 Volts AC, recessed type with high efficiency PMMA diffuser, soft glare free light complete with driver, holder and LED lamp suitable for roof ceiling including connecting up with driver with three core flexible coppder conductor cable of suitable size complete all as specified and directed.Make: Havells Cat Part No -SPARKLEPROADJDLR12W830MOD40DWHTNEEM or equivalent Bajaj/ C&G/ Philips as approved by GE. 112 S&F of flexible LED strip uses high brightness SMD LED as the light source for indoor application, luminaire 24 watt, 220 Volts AC with high efficiency light complete with driver, holder and LED lampsuitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.Make: Havells Cat part No - LHEHDLPFUN1W024 (Flexion Neo Led Strip 24 W of any colour) or equivqlent Bajaj/ C&G/ Philips as approved by GE. 113 Supply, installation, commissioning & testing of IP-65 protection flexion tri coloured LED strip rope light of 120 LED/ mtr of 18 mtrs length with allaccessories of rated input power: 8 W Per meter, LED driver, AC adapter, input voltage rated voltage: 220 - 240 V AC, working voltage range: 100 - 300 V AC, supply frequency: 50/60Hz, power factor >0.9, protections open circuit, LED reverse polarity, surge with standing 2.0 KV, CCT 3000K/ 4000K/ 6500K, temperature: 0 to 50°C high quality of lighting color consistency but also protect products outdoor against from harsh environments outdoors, used for decoration lighting and guidance lighting outdoors, delivers good performance of lightig in tri color complete all as specified and directed.Make: Havells Cat part No - LHEHBPP1TN6F375 or equivqlent Bajaj/ C&S/ Philips as approved by GE. 114 S&F in replacement LED decorative wall light, gold finish fixture with white glass diffuser suitable for 9 W LED bulb E-27 base complete all as specified and directed.Make: Havells Cat part No. Floretine WL 1LS E27 CGN or equivqlent Bajaj/ C&S/ Philips as approved by GE. 115 S&F in replacement LED garden light (BAMBOO LED BOLLARD), new generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape, IP 65 luminaire for diffused lighting with high power LED as light source complete all as specified and directed.Make: Havells Cat part No - BAMBOOBLS8WLED830PSYMTOPC or equivalent Bajaj/ C&G/ Philips as approved by GE. 116 S&F in replacement curved 6 watt LED warm white adjustable multiple angle mirror light including inbuilt LED driver, new generation, energy saving, environmental friendly, long life aesthetically designedfor diffused lighting with high power LED as light source complete all as specified and directed.Make: Havells/ Bajaj / C&G complete all as specified and directed by GE 117 S&F in replacement 3 watt LED warm white rotate in 360 degree angle bed side light including inbuilt LED driver, energy saving, environmental friendly, long life aesthetically designed aluminium landscape for diffused lighting with high power LED as light source complete all as specified and directed.Make: Philips Cart Part No - 48042 or equivalentBajaj/ C&G/ Havells as approved by GE. 118 S&F of non metallic rigid PVC casing and caping, ISI marked of 20 mm size complete all as specified and directed. 119 S&F of non metalic PVC conduit, medium grade, ISI marked of 20 mm dia complete all as specified and directed. 120 M&L for earthing complete with galvanised steel plate earth electrode 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (nominal mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing including dismantling of old earthing complete all as specified and directed. 121 S&F in replacement 500 ltrs capacity rotational moulded 3 layers HDPE water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia tank nipple complete all as specified and directed 122 S&F in replacement 1000 ltrs capacity rotational moulded 3 layers HDPE water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia tank nipple complete all as specified and directed 123 S&F in repairs 25 mm PVC float valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball and fixed with fittings such as (socket, nipple, union) etc. complete all as specified and directed. 124 S&F in repairs 20 mm PVC float valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball and fixed with fittings such as (socket, nipple, union) etc. complete all as specified and directed. 125 M&L for cleaning and degermination inside of RCC/ PVC water storage tanks of capacity not exceeding 500 Ltrs of any description and in any position comprising seven stage cleaning and sterilization of water tanks through bacteriological treatment complete all as specified and directed comprising of following stages:-(a) First stage is to drain out the water by using exit valve or high capacity dewatering systems or any other suitable method.(b) Second stage is to clean all algae formation inside the tank by using Terbac G5/ Inchlor-5/ NB-10 and scrubbing the walls of the tanks.(c) Third stage is for cleaning with fresh water by high speed jet pump with pressure 5 PSL.(d) Fourth stage first bacteria screening and sterilization by using Terbac G5/ Inchor-5/ NB-10.(e) Fifth stage is for cleaning the floors of the water tank by heavy duty industrial vaccum cleaner.(f) Sixth stage is for second bacteria screening and sterilizing method by using ultra violet ray ejector covering 360 degree with in the tank and kills all suspended bacteria.(g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agend Terbac G65/ Inoxi-60/ NB-69.Notes:- (i) Test certificate of chemicals from Government Laboratory mentioning suitability for sterilization should be submitted to the office before using for Sterilization.(ii) Outlet pipe of OHT should be plugged before cleaning the OHT to avoid entering scale and the same shall be reconnected after cleaning the OHT and the quoted rate is deemed to include for this provision.(iii) Contractor will be responsible for rectification of defects occurred during cleaning of tank i.e. No water in tank/ Over flow due to broken of float valve/ blockage of outlet lines due to silt and rectification cost will be deemed to be included in quoted rate. 126 All as per item No. 124.00 here-in-before but of capacity exceeding 500 ltrs and not exceeding 1000 ltrs complete. 127 Deduct Schedule of credit (calculation will be done off line)Rs. 49422.00