Tender For Work Of Repairing Tar Fencing In The Large Variety Breeding Area Of Vikash Khand Naugarh, Bhaisdoda Naugarh, Of Naugarh Block Of Chandauli. - Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. DSR 15.56 2 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. DSR 13.91 3 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.DSR 2.8.1 4 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources DSR 4.1.8 5 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level in :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). As DSR Code No-5.2.2 6 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)Above Plinth Level. As per DSR Code No-5.2.2 7 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). Above Plinth Level. As per DSR code No-5.3 8 Centering and shuttering including stutting, propping etc. and removal of form forFoundations, footings, bases of columns etc. for mass concrete. As per DSR Code No- 5.9.1 9 Centering and shuttering including stutting, propping etc. and removal of form for Lentels, beams, plinth beams, girders, bressumers and cantilevers, As per DSR Code No- 5.9.5 10 Centering and shuttering including stutting, propping etc. and removal of form for Columns, pillars, piers, abutments, posts and struts. As per DSR Code No- 5.9.6 11 Centering and shuttering including stutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access plateform. As per DSR Code No- 5.9.3 12 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR 5.22.6 13 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) DSR 6.1.1 14 Brick work with common burnt clay F.P.S. (non modular) bricks of Class designation 7.5 in super structure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:6 ( 1 cement : 6 coarse sand ). As per DSR Code No 6.4.2 15 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of Class designation 7.5 in super structure above plinth level upto floor V level. cement mortar 1:3 (1 cement : 3 coarse sand ). As per DSR Code No 6.13.1 16 Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand):Flush / Ruled! Struck or weathered pointing DSR 13.31 17 12 mm thick cement plaster of mix 1:6 ( 1 cement : 6 fine sand ) As per Code No 13.1.2 18 Finishing walls with Acrylic smooth exterior paint of required shade: - New work (Two or more coat applied @ 1.43 Ltr./10 Sqm over and including priming coat of exterior primer applied @ 0.90 kg/10 sqm) DSR 13.47.1 19 Fencing With G.I. barbed wire with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :- Payment to be made per metre cost of total length of barbed wire used.. DSR 16.17.1 20 Supply and Fixing of murga jali jali.1/2 24 gauge 21 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.As per DSR Code 10.2 22 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle ironand 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, i/c applying a priming coat of approved steel primer. Using flats 36x6 mm for diagonal braces and central cross pieceAs per Code 10.5.2 23 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture DSR 13.48.3 24 Providing reinforced by organic fibers and/or inorganic synthetic fibers cement 6 mm thick corrugated sheet (as per IS:14871) roofing up to any pitch and fixing polymer coated Jor L hooks,bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete (excluding the cost of purlins,rafters and trusses) i/c cutting sheet to size and shape wherever required. As per DSR Code 12.8 25 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes.As per DSR code 10.16.3 26 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate DSR 11.3.1 27 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. (Under Floor) As per DSR Code No. 2.25 (a) 28 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with mdular type switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. DSR 1.10.1 29 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. DSR-22 E&M Code no. 1.14.1 30 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. DSR 1.14.2 31 Supplying and fixing brass batten/ angle holder including connection etc. as required. DSR-22 E&M Code no. 1.34 32 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 12 way, Double door. DSR-22 E&M Code no. 2.3.3 33 SupplyingandfixingsuitablesizeGIboxwithmodularplateandcoverinfronton surfaceorinrecess,includingprovidingandfixing6pin5/6&15/16Amodular socket outlet and 15/16 A modular switch, connections etc. as required. DSR-22 E&M Code no. 1.32 34 S/F of CPVC pipe 25 mm dia incl all fittings DSR 18.7.3 35 S/F of full way gatevalve 25 mm dia incl all DSR 18.17.1 36 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931(a) 15mm nominal bore As per Code No.18.49.1 37 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Angle back wash basin size 600 x480 mm with single 15mm C.P. brass pillar tapAs per DSR Code 17.7.5 38 Supply,installation,testing &commissioning of 18 Watt solar Street Light on 6 m G.I. Pole with 75 wp solar module & 12.8 V 45 AH Lithium ferro phosphate battry with 5 year compressive warranty 39 Supply and fixing of informatory Sign board.