Tender For Construction Of Fol Storage Area At 151Sqn At Af Stn Carnicobar.; 1 Surface dressing not exceeding 15 cm deep in soft/loose soilall as specified and as directed. 2 Removing excavated material (soil) exc. 250 m but n exc. 500 m and depositing where as directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed. 3 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out getting out complete all as specified and as directed. 4 Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete including necessary form work complete all as specified and as directed. 5 Material and labour forreinforced cement concrete M-30 design mix using 20 mm graded stone aggregate as in foundations including raft, footings , plinth beam, bases for columns, basement slabsand mass concrete and similar workcomplete all as specified and as directed. 6 Material and labour for Reinforcedcement concrete M-30 design mixusing 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts etc all as specified and as directed. 7 Material and labour for reinforced cement concrete M-30 design mix using 20 mm graded stone aggregate as in as in beams, cantilever, bressummers, lintels over 1.5M span etc complete all as specified and as directed. 8 Material and labour for reinforced cement concrete design mix M-30 using 20 mm graded granite stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likecomplete all as specified and as directed. Note : Reinforcement and form workshall be measured and paid separately. 9 M&L for Pre-cast cement concrete block masonry withsolid blocks using type C1(1:3:6) (20mm graded aggregate) ,size exc 10cm in width and setting in cement mortar 1:6 complete all as specified and directed. 10 Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed. 11 Material and Labour for anti termite treatment with Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed. 12 Material and Labour for anti termite treatment with Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed. 13 Material and Labour for anti termite treatment with Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed. 14 Material and labour for sand filling using dry river sand, under floors, spread, levelled to a true surface including watering and consolidating complete all as specified and as directed. 15 Material and Labour for red earth/moorumfilling in floors or pavings, laid in layers n exc 15 cm thick spread, levelled and rammed including watering all as specified and as directed. 16 Material and labour for hard core with broken stone or boulders of gauge not exceeding 63 mm, deposited, spread, and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface all as specified and as directed. 17 Material and Labour for 75mm thick Plain Cement Concrete 1:3:6 type C2 using40 mm graded stoneaggregate as in plinth protection, floors, pavings and hardstanding etc, finished even smooth without using extra cement etc including necessary forwork, complete all as specified and as directed. 18 Material and labour for 25mm thick plain cement concrete 1:2:4 type B0using 12.5 mm graded stone aggregate as in as in leveling course including use of form work as necessary completeall as specified and as directed. 19 Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete all as specified and as directed. 20 Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams to rough finished surface of concrete for flat complete all as specified and as directed. 21 Use and waste of formwork to sides ofpillars, post, struts, piers, coloumn and stanchions, square, rectangular or polygonal, fair finished surfaces of concrete all as specified and as directed. 22 Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings, and similar work, not exceeding 200 mm thick etc, fair finshed surfaces of concrete (Horizontal or sloping) complete all as specified and as directed. 23 Material and labour for rendering 10mm thick in Cement Mortar 1:6 on fair faces of internal brick walls or on concrete surfaces, finished even and smooth,without using extra cement complete all as specified and directed. 24 Material and labour for 15 mm thick renderingon brick/concrete surfaces in two layers in CM 1:4, finishing coat of 5mm thick using water proofing compound @3% by weight of cement, finished even and smooth without using extra cement complete all as specified and as directed.Note: Water proofing compound shall be measured separately. 25 Supply only integral water proofing compound all as specified and as directed. 26 Material and labour for preparation of of new plastered/concrete surfaces of walls and applying two coats ofacrylic distemperof approved shade/tint over a coat of primer,over 3mm thick wall care putty finish to achieveuniform smooth surface of wallall as specified and as directed. 27 Material and labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. 28 Material and Labourfor TMT bar 10mm dia and over, cut to length, bent to shape required, including cranking,bending spirally for hooping ,for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 29 M&Lmild steel TMT bars 5mm diaandover up to 10mm for stirrups cut to length , bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia bars confirming to Fe-410-S or Fe-410-0complete in all respect as specified and directed. 30 Supply and fix Steel rolling shutters 1.25mm thick, width of lath 75 mm, with out ball bearingwith gear operated type with chain wheel and hand chaintype as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position complete all as specified and as directed. 31 M&L for preparation of new or previously untreated steel surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxideprimer complete all as specified and as directed 32 Supply and fix aluminium powder coated frame for doors,windows, ventilators with one or more rebates with joint clip and using rubber beading etc complete all as specified and directed.Note:Glass panel/particle board panel filling shall be measured and paid separately. 33 Supply and fix for powder coated,Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.), hinges type B-21 100mm long (2 no.) suitable handle (1 no.) completeallasspecified. 34 Supply and fix 5.5 mm thick sheet glass, ordinary quality and glazing with oil putty in squaren.exc 0.5 sqm in each pane, complete all as specified and as directed. 35 M & L for point wiring using 1.5 Sqmm lSI marked 1.1 KV grade single core FR LS flexible cable, conforming to IS: 694-1990, having multi-drawn thin strands of electrolytic copper conductors, conforming to IS: 8130-1984 and insulation conforming to IS:5831-1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in and including not less than 20 mm NB PVC medium grade conduits (concealed), conforming to IS: 9537 (Part 3)- 1983, colour coded as specified in IS: 11353-1985, including factory made sunken, galvanized, not less than 1.00 mm thick modular flush sheet metal enclosure having top, bottom, side and back-wall knockout for conduit entry from any direction, conforming to IS: 14772- 2000 and suitable for modular cover-plates complete all as specified in IS: 732-1989 and directedfor the following:-. Note: Circuit wire from DB to switch boards shall be included in the quoted rate. No additional payment will be paid to the contractor for the circuit submain.(a ) onelight/fan point controlled by one switch 5 Amps 36 Supply and fix Switch flame proof, rotary type with termination box in LM6,16 A, single pole, 250 V complete all specified and as directed. 37 Supply and Fixing of Flameproof cum Waterproof LED light fitting of 16W, CMRI certified recommended for gas/vapor group of IIA & IIIB, Zone 1 & 2 and IP65 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen A clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size.complete all as specified and as directed.Make:Bajaj/ L&T/Crompton Greaves/Havells 38 Supply and fix Flame proof exhaust fan of size 300 mm sweep with louvers,having air discharge capacity of 1120CFM with metal body AC 230 V, 50 Hz, 1440 RPMand connecting to ceiling rose terminals with 23/.0076 flexible cable complete all specified and directed. Make:Havells/ Usha/Crompton Greaves. 39 Supply and fix MCB SPN 40-63 amp rating 240V, 10KA C curve miniature circuit breaker (MCB) of single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed.Make: Indo Asian/ L&T/Crompton Greaves/Havells 40 Supply and fix MCB SP 6-32 amp rating 240V, 10KA B curve miniature circuit breaker (MCB) of single pole in the MCB DB,IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed.Make: Indo Asian/ L&T/Crompton Greaves/Havells 41 Supply and fix Flame proof Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 4 way with 5000 Amps rated copper bus bar double doorprotection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommer flush to wall complete all as specified and as directed. 42 Material and labour for Sub main wiring using two runs of single corePVC insulated cable (FR) 6 sqmm copper conductor multi stranded and one run of 6 sqmm copper conductor insulated cable (FR)using as earth wire drawn through and including suitable size surface/recessed steel/PVC conduct including taking down old aluminium/CopperSub main wirng complete all as specified and directed. Note-3 run of 6 sqmm PVC copper wire and One run of PVC casing caping shall be measured and paid as oneunit. 43 Supply and fix Copper Air termination rod 12 mm dia single pointed 300mm longalong withbase plate welded at bottom of termination rod, of size 10 cm longfabricated out of 32 x 6 mm thick Copper strip along with making 9mm dia for fixing in fastners complete all as specified. 44 Supply and fixing galvanised steel water tubing medium grade 20 mm bore including all necessary fittings such as bends, L bows, short piece connections, backnuts, caps plugs, unions couplings, flanges, sockets etc,fixed to wall/floor/ceilingincluding necessary cutting/chauging in walls made of brick/concrete surface complete all as specified and as directed. 45 Supply and fix test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw all as specified and directed. 46 Supply & fixing Earthing complete with copper earth plate electrode 60cm×60cm× 3.15mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to20×3mm copper strip as earthing lead, by means of bolts, nuts, check nuts and washers ofbrass or steel all as shown in electrical plate No. 3 connected to earthing test point all asspecified or indicated including testing on completionall as specified & directed .Notes:Quoted rates shall be deemed to be included the following (a) Excavation ,RFR earth workin any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1, pre cast RCC cover40 mm thick in PCC 1:2:4type B-1, with suitable handle reinforced with welded steel wire fabric weighing not less than 1.87 kg/sqm.(c) funnelwith wire mesh , watering pipe of GI 20 mm nominal bore light grade and lugs etc. complete all as specified & directed. (d) 32 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified & directed. (e) Requisite quantity of common salt and charcoal in alternative layers as specified. 47 Supply and Fix High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches 40 mm bore with all acessoires for cable protection, complete all as specified and as directed. 48 Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting outin soft/loose soil complete all as specified and as directed. 49 Material and labour for cement concrete work in pavement/hard standing of flexural strength 40 Kilogram/Sqcm in field using 400 Kilogram of cement per cubic meter thickness of concrete 25 cm or less all as specified and as directed. 50 Removing excavated material (soil)n.exc 50 m and depositing where as directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed. 51 Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel stripor wire armoured electric power cable conforming to IS:7098 (Pt-I)-1988, heavy duty with stranded aluminium conductor 1100 Volts grade of size 6 Sqmm 4 core with necessary fixing arrangements such as lungs, glands and terminal etc including connecting/testing after taking out unserviceable LT UG cable from trenches/ polecomplete all as specified and directed.NOTE: Excavation, earth work shall be measured and paid for separately. 52 Supply and laying double wall corrugated pipe (DWC) conforming to IS 14930 Part - I of size 40 mm outer dia and 32 mm inner dia complete all as specified and as directed 53 Material and labour forcutting bituminous road/ harstanding(hard Rock ) of any description not more than 50CM x 50 CM size forlaying of pipe or cable (crossing the cables across the road) and making good with PCC 1:3:6 type C2 using 40mm graded stone aggregate, removing the surplus material away from the site, all as specified and directed by the Engr-in-charge 54 Supply & Fix 25 mm dia galvanized iron tube medium grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed.