| 1 | B/R WORKS |
| 2 | Cement concrete, type B-1 (1:2:4), using 20 mm graded stone aggregates as in lintels over 1.5 metre clear span, cills, steps, seismic and other similar band, plinth courses, lacing courses , copings, kneelers, apex stones, bed plates, water troughs and the like complete all as specified. |
| 3 | Brick work using bricks as specified in PS clause 5.1, continuous brick edging with height equal to the width of the laid dry on edge or in angle shape on curve for making / laying for running track both side complete all as specified. |
| 4 | Mild steel works in hand rails, half round or other stock section or core for wooden handrail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) in-cluding all necessary drilling, bolting or riveting, etc., confirming to Fe-290-Gde E-165, complete all as specified |
| 5 | Supply only chain link mild steel galvanised hot dippedfencing (mesh size100mm x 100mm of 4mm wire)complete all as specified.NOTE:- The weight of chain link fencing shall be ascertained by BOO as ordered by GE and payment shall be made acoordingly. |
| 6 | Fixing only chain linkfencingincluding line wire mesh, any mesh, size and type to any types of standards rails, straining bolts, etc. including provision of binding wire complete, all as specified. |
| 7 | Mild steel round bars 10mm dia and over, cut to length, bent to shape required, for chain link fencing complete, all as specified. |
| 8 | Stainless steel waiting bench seating capacity of 03 persons & size ( length not less than 1750 mm longer side) any colour along-with back seat and with side arm rest,complete.NOTE- Design as approved by GE |
| 9 | 100 mm thick Plain Cement Concrete 1:2:4 type B-1 using 40mm graded crushed stone aggregate as sub base in flooring / hardstanding etc. complete all as specified.NOTE:- The rate included of necessary form work. |
| 10 | 100 mm thick Plain Cement Concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as sub base in flooring / hardstanding etc. complete all as specified.NOTE:- The rate included of necessary form work. |
| 11 | Plastic dividing strip to prevent cracks 38mm wide and 1.5mm thick inserted in position and confom to design complete all as specified. |
| 12 | M&L Providing, Supplying and installation of 8 layer acrylic synthetic flooring for basketball/volleyball/throwball court (3 to 4 mm thick) over existing plain cement concerete with folloiwng stages given below:-PATCH: 100% Acrylic based emulsion to repair cracks to concrete and asphalt pavment it should be carried out after 30 days from dateof placement of concrete.PRIMER:-100% Acrylic unic floor based emulsion to improve bond of acrylic court system to the concrete or asphalt surface.RESURFACER:-02 Layers of Acrylic Resurface 367-30 for filling and smoothing asphalt or concrete surface in preparation for Acrylic ITF approved system and fills the surface chips, voids and conceals repairs while providing a smooth surface for colour coating.CUSHION COAT:- 01 layser of cushion coat consisting thicker rubber granules having comsumption of about 30-45 sqft per KG to be applied with rubber sequeeszee. This cushion coat to be mixed with potable water and silica aggragate beofre installation. Acrylic floor cushion for asphalt or concrete surfaces in preparation for Acrylic ITF approved system.ULTRA CUSHION COAT:- 02 layser of cushion coat consisting thicker rubber granules having comsumption of about 15-25 sqft per KG for 2 layers to be applied with rubber sequeeszee. This cushion coat to be mixed with potable water and silica aggragate beofre installation. Acrylic floor cushion for asphalt or concrete surfaces in preparation for Acrylic ITF approved system.PRE COAT:- 02 layer of Acrylic based textured tennis top coat. Ideal for colour coating basketball/Volleyball/thro ball/through ball courts and other sport pavment surfaces complete all as specified and directed.Note:- (i)Over 30 days old from the date of placement of concrete alongwith repairing of cracks of concrete and asphalt surface the Acrylic Synthetic Flooring work of Basketball/Volleyball/Throwball is carried out.(ii)The work shall be got executed throughauthorized applicators of manufacturer’s only |
| 13 | S&F (Installation of turf) (a) Synthetic Artificial Turf, Pile Height 50mm. (b) Backing of Turf : Turf will be provided with duble backing with PU (Poly Urethane) specialized for play purpose. (c) DTEX 18000. (d) Sewing/ Gluing of Joints. (e) Jointing of Turf with Glue for installation. (f) Infill of Graded silica sand. (g) Infill of Ambient Rubber granules. (h) Making of Volleyball court. Note : Warranty 5 Yrs from the dt of installations (ii) Work done through auth applicant only. |
| 14 | Endura vitrified paving coloured tiles 9 to 10 mm thick (square/ rectangular) area of each tile exc. 0.11 Sq.m but not exc. 0.18 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed in grout of matching shade, laid over and including 20 mm thick bedding layer in cement mortar (1:4) complete all as specified. |
| 15 | Granite 15-18 mm thick,as in step, jambs, cooking platform and like, machine cut, machine polished,bedded and jointed with grey cement slurry & pointed with grout of matching shade including necessary cutting over & including 10 mm thick (average thickness) cement mortar (1:4), complete all as specified. |
| 16 | Rendering 15 mm thickon fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), mixed with water proofing compound as per manufacturers instructions, complete all as specified.NOTE:- WPC will be measured and paid for separately under respective item of BoQ. |
| 17 | Supply only water proofing compound, ISI marked, complete all as specified. |
| 18 | Prepration of new plasterd wall surfaces of any description & applying Two coats of exterior acrylic emulson over and including a coat of water based exterior primer complete all as specified. |
| 19 | Complete removal of existing treatment of any description on wall& applyingTwo coats of exterior acrylic emulsion over and including a coat ofwater based exterior primer & including prepration of wall surfaces of any description complete all as specified . |
| 20 | Marking of basket ball / Volley ball court as approved colour oftwo coatsof synthetic enamel paint over & including a coat ofprimer on 8 layer acylic synthetic flooring surface complete all as specified. |
| 21 | Peparation of old painted steel & iron surfaces of any description not other wise described over 10cm width or girth and applying one coat (finishing coat) of synthetic enamel paint complete all as specified. |
| 22 | Two coatsof synthetic enamel paint over & including a coat of red oxide primer over steel or iron surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces, complete all as specified. |
| 23 | Taking down cement plaster of any description on brick walls or concrete surfaces etcincluding raking out joints, hacking for key, scrubbing down with water etc complete all as specified. |
| 24 | Demolition of un-reinforced cement concreteof any description and in any position not otherwise specifically provided all as specified. |
| 25 | E/M WORKS |
| 26 | Point wiring complete with 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with milti standaed copper conducton drawn through and including non metallic rigid medium grade PCV conduit with alll accessories alongwith fixing arrangements concealed in walls roofs, floors etc. or fixed in walls and including provision of 2.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor connected to common earth dolly including providing suitable size mild steel terminal boxes concealed in walls with new 3 mm thick hylum sheet top cover or new PVC gang box fixing on wall surface to accommodate switches, fan regulators, sockets, socket outlets, etc, all as specified and as directed. |
| 27 | Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade for earthing in conduits, with and including rigid non metallic PVC medium duty concealed conduit not less than 25mm dia complete all as specified for the following: - |
| 28 | 2 runs of single core of6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable. complete all as specified and directed.NOTES: (i)For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as \"1 RUNNING METRE\" |
| 29 | MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, \"C\" curve type of rating6 to 32 Amp, complete all as specified and directed. |
| 30 | MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, \"C\" curve type of rating 32 to 40Amp,complete all as specified and directed. |
| 31 | Sheet metal enclosure for DB for fixing MCCBs / MCB’s, isolators etc., having IP-43 protection, suitable for surface and flush mounting, complete all as specified comprising the following: - |
| 32 | SPN, 8 way with 200 Amp rated bus bar, 240 V, double door type. |
| 33 | TPN, 4 way with 200 Amp rated bus bar, 415 V, double door type having housing and including MCCB 4 pole 63 Amp, 16kA. |
| 34 | LED flood light 120 Watt outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrossion resistant, with driver and lamp die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting, with high power LED as light source with suitable drivers etc and connecting with 4.0 Sqmm aluminium conductor PVC insulated twin core weather proof cable etc, fixing to wall/pole, of following capacity, complete.Note:-(i) Contractor has to produce LM-79/LM-80 certificate along with purchase vouchers and Guarantee certificate from Manufacturer.(ii) Surge protection of the driver should be 10 KV. |
| 35 | Excavation in trenches in SOFT/LOOSE soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, taking out/ laying pipe line, cable etc. and getting out complete, all as specified. |
| 36 | Returning filling in including spreading, levelling, watering and well ramming in layers notexceeding 25cm thick complete all as specified. |
| 37 | Removal of excavated surplus spoil to a distance n. exc. 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified. |
| 38 | Brick protection with pulverized fuel ash lime brickslaid flat across the route of underground cable all as specified. |
| 39 | Sand cushioning ( local dry river sand) for under ground cable 23cm thick (one layer of 8cm thickness before laying the cable and other layer of 15cm thickness after laying the cable) all as specified.NOTE:- Punned down thickness (over all 18cm) shall be considered for measurement and payment.) |
| 40 | GI pipe 50mmborelight grade with all fittings fixed as termination postal ,fixed to poles/ walls/ under floors/ under road etccomplete all as specified. |
| 41 | Supplying, laying, jointing and testing XLPE insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor of sectional area 35 Sq.mm,4 corelaid in trenches/ ducts/ through pipes/ in floors / underroads/ hard standing /along poles and testingcomplete all as specified : - |
| 42 | Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GIstrip 32x6 mm as earthing lead by means ofGI or steel bolts/nuts/washers, protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mmbore GI light grade pipe for watering and including funnel, wire mesh, RCC cover, reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 12 mm dia, using round bar, PGI funnel with wire mess & frame, PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of MES Schedule Part – I. complete all as specified. Note:- (i)PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.(iii) Earth resstance shall be less than 3 ohm. In case the test results are not found less than 3 ohm, complete earthing shall be redone by the contractor without any extra cost to Govt. |