Supply And Installation Of Advance Life Support Ambulance With Fully Loaded Equipment Accessories To G.G.H. Eluru, Eluru District In Andhra Pradesh , Advance Life Support Ambulance With Fully Loaded Equipment And Accessories-1.1 A Ambulance shall be Type D and Category of M2 Vehicle. Vehicle Engine Capacity (cc) shall be 2100 to 2500. Type of Fuel shall Diesel BS-VI in white color with red strip and department name and logo. Whole ambulance shall be fully airconditioned 1.2 Vehicle Mileage ( declared by OEM as certified by Test Agency under Rule 115of CMVR 1989) (Kmpl) shall not less than 16.5 and Top Speed (km/hr) shall not less than 110 km/hr 1.3 Gradeability of Vehicle (degree ) shall not less than 14.5 degree and Turning radius (mm) shall 6800 millimetre. 1.4 Acceleration (0-70KmPH) in sec shall 19-20 second. Engine shall not less than 100 horsepower and Rated RPM at Max Engine BHP shall 3750 1.5 Engine Torque Max (N-m) shall 200. Rated RPM at Max Engine Torque shall 1000. The whole ambulance shall fully air-conditioned 1.6 Type of Vehicle Body shall monocoque and total doors shall not less than 03. 1.7 Fuel Tank Capacity (liter) shall not less than 60 ltrs 1.8 The minimum engine BHP shall not less than 100 horsepower. Rated RPM at max engine BHP shall 3750. Engine torque max (N-m) shall 200. Rated RPM at max engine torque shall 1000. 1.9 Length of Vehicle Body (mm) shall 5478 millimetre Width of Vehicle Body (mm) shall 1905 millimetre Height of Vehicle Body (mm) shall 2670 millimetre Ground Clearance (road Clearance from floor) (mm) shall 185 millimetres. Wheel Base (mm) shall 3488 millimetre Kerb Weight (kg) shall not more than 2160 kilogram Gross Vehicle Weight (kg) shall not more than 3385 kilogram 1.10 Tyre and Tube shall BIS marked Pneumatic Tubeless tyres Size Of Tyre shall 195 R15LT 8PR. 1.11 Vehicle transmission system shall manual and Nos of Speed/ Forward Gears shall be 5.Type of Wheel drive shall two wheel drive and drive axle shall front axle. Steering shall power steering. Vehicle Brake shall ABS Fitted, Low Fuel warning Light. Front vehicle brake shall disc brake and rear vehicle brake drum brake. Vehicle air intake system shall Turbo Charged. FABRICATION OF INTERIOR 2.1 Interior paneling fabricated with Fiber Reinforced Plastic (FRP) 2.2 Thermal insulation providing better atmosphere temperature inside patient cabin 2.3 Driver & patient cabin partition in FRP with sliding communication window 2.4 Overhead rack with sliding glass for storage. 2.5 Non static, anti-skid Vinyl flooring on 12mm FR Grade ply-board. 2.6 Grab rail on rear entry door for easy access. 2.7 Roof Mounted Stainless Steel hand support rail with 2 No’s of strap Handles. 2.8 Ergonomically designed Storage drawers for medical consumables and accessories within easy reach from Paramedic seat. 2.9 Stainless Steel waste bin for Biomed waste 2.10 Hooks for IV Bottle’s -2 No with IV holding attachment 2.11 Provision to Mount Critical Care Equipment like Ventilator, Defibrillator, Monitor etc. (Original mount to be provided by the customer along with equipment) 2.12 Full Length Foot step at rear entry 2.13 Fire extinguisher 1Nos ELECTRICALS 3.1 Internal lighting- LED 3.2 220V AC 5 Amp Sockets-4 no 3.3 12 V DC Socket – 2 No. 3.4 True Sine Wave Inverter of 800 VA capacity with additional backup battery 3.5 High intensity LED blinkers 2 No’s each on three sides (6 No’s) 3.6 Charging Socket for Inverter from 220 VAC with 5 meters of charging lead. 3.7 LED Emergency Light Bar &Siren with public address system 100 W. 3.8 Fans -2 No’s. LED Interior Tube lights. Lights 12V DC – 6 No’s LED Patient Examination Light 1 No’s Electric Protection Circuit with heavy duty 12 V DC Cut off switch located near driver seat for easy accessibility. Rear Door Switch light to illuminate Patient Cabin light. Rear door open warning alarm in Driver cabin AIR CONDITIONING 4.1 Centralized ducted air-conditioning system coupled with vehicle Engine for Patient Cabin. OXYGEN THERAPY 5.1 Heavy duty trolley to mount 2 Nos. JUMBO ‘D’ Type OXYGEN cylinders changeable from outside the vehicle with separate lockable door helps in maintaining good hygiene in patient cabin. High Pressure flexible stainless steel braded Teflon tubing from oxygen cylinders to regulators. Oxygen regulator for better patient safety with pressure gauge’s near doctor seat for easy accessibility. Complete gas pipe lining with tubing on common rail with 2+1 oxygenoutlet. PATIENT HANDLING & MEDICAL EQUIPMENT: (OPTIONAL) 6.1 Auto Loader Stretcher:- Should have AIS 125 Certified Scoop Stretcher:- Lightweight , Portable Aluminum Scoop Stretcher 6.2 SPINE BOARD:- Made of High Strength engineering plastic Portable and anti-aging, Can float In water Suitable for all Radio-diagnostic X-ray procedure 6.3 HEAD IMMOBILIZER:- Water Proof plastic Coating to prevent bacterial growth Unique Head Straps to confirm patient’s fore- Head. 6.4 WHEEL CHAIR Made of high quality aluminum alloy Adjustable Telescopic handles 6.5 Pneumatic Air Splints with pneumatic pump-Set of 6 Good quality Suction Machine Foot and Battery operated Pulse Oximeter Finger Tip MULTIPARA MONITOR 7.1 Monitor should have high resolution 12.1 colour, LED display. Should be able to display atleast 6 waveforms. 7.2 Should be able to monitor following vital sign monitoring for Adult, Paediatric and neonatal patients such as ECG, NIBP, Spo2, Respiration, Temperature. 7.3 Should be able to monitor ECG: 3/5 lead, Cascade ECG waveform with HR measurement, arrhythmia detection, ST segment analysis. 7.4 Non-Invasive Blood Pressure (NIBP): Measurement and display of systolic, Diastolic, and mean pressure values on NIBP measurement through Oscillometric method for adult, child, and neonate. Modes: Manual, STAT (Continuous 5 min. operation) and automatic selectable interval 2- 480 minutes. 7.5 Respiration: Display of respiration waveform with respiration rate using impedance principle. 7.6 Temperature: Should be able to monitor two temperatures simultaneously. The unit selection should be possible. 7.7 SpO2 sensors should be suitable for Adult, Paediatric & Neonate. Should be upgradeable to Etco2 and Dual IBP 7.8 The Graphical and tabular trends of up to 168 hours should be available. The monitor should have battery backup of up to 5 hours. Should have automatic pacemaker detection facility. Should be Compatible with central monitoring system both wired and wireless. Should be Compatible with HL7 and Nurse Call. The Weight of monitor should not be more than 3 kgs. Should have three priorities of alarm of all the parameters. Should have option of recording up to 2waveforms on paper roll. TRANSPORT VENTILATOR 8.1 Display: 3.5 Inch Monochromatic Display AVAILABLE MODES: PCV, VCV, VACV, PACV, VSIMV, PSIMV, CPAP, BIPAP, HFTWaveforms: Pressure PEEP :0 TO 30 cm H2O (ELECTRONIC) PRESSURE SUPPORT :0 TO 50 cm H2O RESPIRATORY RATE: 7 TO 60 BPM INSPIRATORY PRESSURE: 5 TO 100 cm H2O▪ High pressure limit▪ Low pressure limit INSPIRATORY TI M E: 0.1 TO 9.9 sec I: E RATIO: 1:9.9 -2.5:1 TRIGGER: PRESSURE (0.5 TO -20CM H2O) TIDAL VOLUME: 40ml to 2000ml FIO2: 21% TO 100% DIMENSIONS (W*D*H): 300 mm* 260 mm* 130mm EX SENCE: 50% To 100% APNEA BACKUP: YES DETACHABLE AND AUTO CLAVABLE EXPIRATORY VALVE: YES RECHARGABLE Li-ion BATTERY: BACKUP UPTO 12 HOURS AUOTAMATED EXTERNAL DEFIBRILLATOR 9.1 It should be Semi-automatic external defibrillator. Should withstand free fall damage from a height of 1.5mtr onto the hard surface. Waveform should be Bi-phasic, Truncated exponential (BTE) waveform. Impedance Range 20-180Ω Energy Level should be:Adults energy released at 50Ω impedance: 150 J. Children Energy released at 50Ω impedance: 50J The energy levels should be fixed. Should have CPR Coaching CPR instructions for adults and children, with metronome and hand placement instructions Should comply with AHA 2020 guidelines. Charge/Discharge Time: The time from the prompt of “Shock Advised” to when the shock can be performed: 7 sec. Analysis Time should be typically, 8 seconds. It should have LED lights, graphic panel and voice prompt. Volume should be adjustable through mobile app. Device Status Indicator: Visual and audible indicators help to monitor the status of the main device, electrodes, and battery. Flashing red light indicates the device is faulty. Volume should be adjustable through mobile app Flashing green light should indicates the device is normal. Controls: Users can switch to Child Mode at the touch of a button to lower energy and receive CPR guidance suitable for children (under 8 years old or less than 25Kg.) Communication: USB Interface, Bluetooth (standard); and 4G module (optional) Battery Pack: TYPE- Lithium manganese dioxide (Li/MnO2) battery (non-rechargeable), 12V/3000mAh Battery Capacity: At 20°C±2°C, the new battery can discharge 200±10 times at 150J Operation Life (standby) 5 years (typical). A battery should indicate low battery can still be used 30 times at 150J. ECG/Event Storage: At least 8 hours of ECG and event/incident recording. Environmental Configuration: - Atmospheric Pressure 59.4kPa~106kPa. Operating/Standby Temp 0°C ~ +50°C Relative Humidity 5%~95% (No condensation). One Hour operating Temperature limit (extreme cold): –20°C. Short term Storage/Transport Temp: –40°C~+70°C, within one week, with battery and pads uninstalled. Should have Ingress Protection IP55. Weight should be 1.5 kg. (Including battery, pads & handle). Should also be available in Hindi Language. Should have CE certified. Certificate to be submitted. Should Comply with IEC 60601-2-4 Should be supplied with the AED pad- 1 Pair. SYRINGE PUMP 10.1 Mains /Battery operated Flow rate O.10ml -200ml/hr depending upon syringe size Bolus/KVO Accepts all size syringes PORTABLE OXYGEN CYLINDER 11.1 Made of seam less aluminum or equivalent RESCUE TOOLS 12.1 Set of Rescue tools i.e. wrecking Bar, Crow Bar,Axe, Hammer, Rope, Hacksaw, torch etc. along with D Type Cylinders (2 Nos) EMERGENCY BAG 13.1 Ambu Bag 2 no’s (1 Adult & 1 Paed.) Laryngoscope (4 Blades) Oxygen mask 2 No’s –1Adult & 1Paed. Magill Forceps -1 No. Artery Forceps – 1 No. Toothed forceps-1No. Universal Scissor-1 No. Stethoscope – 1 No. Cervical collar-Adjustable Glucometer Fingertip Pulse oximeter Aneroid blood Pressure unit -1 No. Sterile Gloves-5 Pairs Carrying Case WARRANTY AND SUPPORT 14.1 All the bidders are required to submit Bid specific OEM Authorization Letter in their favor issued by the principal manufacturer for the following items:- Base Vehicle Spine Board Suction Machine Auto loading Stretcher Syringe Pump AED Multipara Monitor Emergency Kit Transport Ventilator 14.2 Manufacturer to note that there shall be a one (3) years warranty period. Warranty period shall commence from the date that the system has been fully accepted following Training and Commissioning 14.3 Rates should be quoted along with all costs including installation, testing and commissioning, No extra amount will be paid. 14.4 A 3 year software subscription license including technical support, quarterly release software upgrades and access to expanding scenario library should bepart of the service. 14.5 Supplier shall commit to providing after sales support without any restrictions for aminimum period of 5 years. Also, supplier should demonstrate their local presence in UP/NCR, India for providing the necessary after sales support. 14.6 All software and software licenses included for operation of the system for a period of 3 years. 14.7 Training for trainer shall be provide by the supplier at UPFS training centre orlocation suggested by DG-UPFS DOCUMENTS TO BE SUBMITTED BY THE BIDDER ALONG WITH THE BID. 15.1 All Relevant BIS/UL/NABL Approval Certificate along with License number. Test Report shall be submitted along with the bid 15.2 Vendor shall submit Manufacture test certificate as evidence for having used materials for various components as per specifications 15.3 Installation manual and Operation manual shall be provide in English and Hindi language 15.4 Before supply the material/goods site inspection shall be carried out at the place of OEM/Bidder by the nominated team from DG F&ES. All Expenses for inspection shall be borne by OEM/bidder.