| 1 | Dismantling and taking out unserviceable MS frontal pipe of IRP of any size and supply and fixing 80 mm bore heavy duty MS frontal pipe including welding, brazing complete all as specified and directed. |
| 2 | Taking up CI water mains of 150 mm bore (including all fittings), with Spigot and Socket ends and burning out the old lead joints, cleaning/ removing deposited sludge etc. including preparing the leak proof new run lead joint complete all as specified and directed. |
| 3 | All same as item No. 02 above, but CI Pipe of size 100 mm bore. |
| 4 | Relaying cast iron pipes of size 150 mm bore with Spigot and Socket endsafter cleaning internal surface of serviceable pipes by using of wire brush and cleaning thoroughly with fresh water and taking out mud/soft deposited inside the pipes ( CI pipe obtained from Ser item No. 4) complete all as specified and directed. |
| 5 | All same as item No. 04 above, but CI Pipe of size 100 mm bore. |
| 6 | Supply and laying for CI pipes of size 150 mm bore with Spigot and Socket ends centrifugally cast, Class LA, in any length laid in trenches complete all as specified and directed. |
| 7 | All same as item No. 06 above, but CI Pipe of size 100 mm bore. |
| 8 | Supply and Fix Butter fly valve of size 100mm boreincluding taking down the old unserviceable valve, preparing the joint and replacing the gasket jointbolts with the new complete all as specified and directed. |
| 9 | All same as item No. 08 above, but 80 mm bore size. |
| 10 | Material and labour for cast iron non return(Reflux) valve with flanged ends Non Return with GM workingparts IS - 5312 heavy duty, drilled for bolts, including necessary rubber gasket joint complete with nuts and bolts for the Non return Valve 150 mm dia bore sizes including taking down theold unserviceable valves complete all as specified and directed. |
| 11 | All same as item No. 10 above, but Non Return valve100mm dia bore size |
| 12 | Material and labour run lead joint for spigot and socket pipe and complete for C.I pipe 150 mm bore size. |
| 13 | All same as item No. 12 above, but C.I100 mm bore size . |
| 14 | Material and labour for C I bends, Tees, collar, Tail piece etc(any type & shape and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) Tee pieces single branch, \"Y\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs suitable for CI pipe upto 100 mm dia complete all as specified and directed. |
| 15 | M & L brick masonry with brick valve chamber of internal size 1.2 M x1.2M x1.0 M with 23 cm thick wall in CM 1:6 including excavation, earth work in any strata & PCC 1:4:8 foundation type D-2, 75 mm thick including 20 mm thick PCC 1:2:4 type B1 in & plastering the internal surface with 10 mm thick cement mortar 1:4 providing 3.15 mm MS sheet chamber cover double opening arrangement center lock system with40x40x6mm angle iron frame duly painted with two coat of black bituminous paint over one coat of red oxide primer complete all as specified and directed. |
| 16 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 17 | Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out/laying CI/GI pipes and getting out in soft/loose soil complete all as specified and directed. |
| 18 | Removing excavation soil at a distance not exc 50 m and deposited where diverted complete all as specified and directed. |
| 19 | M&L for 2 mm thick MS sheet cover plate with locking arrangements in existing valve pit and removing of old / rustedMScoverincl painting complete all as specified and directed. |
| 20 | Demolition of cement concrete in ground floors and paving not exceeding 15 cm thickness including removing the material and deposited complete all as specified and directed. |
| 21 | M & L for Cement concrete type C-1,1:3:6 (40 mm graded aggregate) complete all as specified and directed. |
| 22 | Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, keep Serviceable Bricks in Safe Custody for re-use and taking out the broken and damaged bricks from the site complete all as specified and directed. |
| 23 | M&L Brick Work with Sub-Class ‘B’ Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 metre mean Radius, built in Cement Mortar 1:6, complete all as specified and directed. |
| 24 | M&L Rendering 15mm thick in Cement Mortar 1:6 on fair faces of Brick Work or Concrete Surfaces, Plastered Surfaces finishing Fair and Even, complete all as specified and directed. |
| 25 | Cutting vegetation and surface dressing not exceeding 15 cm deep including removing the materials to a distance not-exc 60 mtr complete all as specified and directed. (Note :- Item shall be executed twice in each installation and quantity is given for two operation. However unit rate to be quoted by the tendered for single operation only) |
| 26 | Dismantling and taking out old unserviceable panel board of any type and shape after breaking of PCC foundation/platform and taking away from existing location after necessary disconnection of all out going andincoming cable joints, earth strips etc. complete all as specified and directed. |
| 27 | Supply , install, testing and commissioning of cubical housing cabinet type LT panel board indoor type, platform/wall mounted factory made, totally enclosed dust and vermin proof openablefromfrontside made out of 2.0 mmthick CRCAMS Sheetof suitable size and built upon suitable size angle ironframe work , having front hinged door,, earthing strips at rear side , bottom/side detachable gland plate complete with suitable size zinc plated and passivized nut, bolts , spring and washers.The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment The panel shall be Epoxy Powder coated and the control circuit diagram shall be with colour code multi slandered conductor copper 1.5 Sqmm . The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:-Incoming Side(i) MCCB4 Poleof capacity 100 Amp ,breaking capacity 36 KA with thermal release-01 Nos(iii) Digital type Voltmeter 0-500 volts, 3 Phase, 4 digit, high resolution, LED type with one side programmability -1 Nos . (iv)Ammeterdigital type three phaseCT operated onside programmablewith copper wound CT coilfor three phases of suitable ratio & size class I accuracy, 0.5 VA burden, -01 Nos (v)Indicator lamp with holder key flush mounted, LED typeRed, yellow, blue with toggle switch-1 SetOutgoing Side(i) MCCB4 Poleof capacity 40 Amp ,breaking capacity 25 KA with thermal release-03 Nos(ii) MCB 2 Poleof capacity 32 Amp breaking capacity 10 KA-2 Nos (iii) Star delta starter suitable for 15 HP Motor with all type of protection-01 Nos(iv) Electronic Motor Protection relaywith in built Earth Fault Protection suitable for 240 V AC thermal O/L Range 16-44 Amps -01Nos |
| 28 | Supply , install, testing and commissioning of cubical housing cabinet type LT panel board out door type, platform/wall mounted factory made, totally enclosed dust and vermin proof openablefromfrontside made out of 3.15 mmthick CRCAMS Sheetof suitable size and built upon suitable size angle ironframe work , having front hinged door,, earthing strips at rear side , bottom/side detachable gland plate complete with suitable size zinc plated and passivized nut, bolts , spring and washers.The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment The panel shall be Epoxy Powder coated and the control circuit diagram shall be with colour code multi slandered conductor copper 1.5 Sqmm . The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:-Incoming Side(i) MCCB4 Poleof capacity 100 Amp ,breaking capacity 36 KA with thermal release-01 Nos(iii) Digital type Voltmeter 0-500 volts, 3 Phase, 4 digit, high resolution, LED type with one side programmability -1 Nos . (iv)Ammeterdigital type three phaseCT operated onside programmablewith copper wound CT coilfor three phases of suitable ratio & size class I accuracy, 0.5 VA burden, -01 Nos (v)Indicator lamp with holder key flush mounted, LED typeRed, yellow, blue with toggle switch-1 SetOutgoing Side(i) MCCB4 Poleof capacity 40 Amp ,breaking capacity 25 KA with thermal release-03 Nos(ii) MCB 2 Poleof capacity 32 Amp breaking capacity 10 KA-2 Nos (iii) Star delta starter suitable for 15 HP Motor with all type of protection-01 Nos(iv) Electronic Motor Protection relaywith in built Earth Fault Protection suitable for 240 V AC thermal O/L Range 16-44 Amps -01Nos |
| 29 | Supply, connecting & fixing of submersible PVC insulated PVC sheathed 3 core flat copper cable of size 6 sqmm, 1100 V grade conforming to IS 694 : 1990 without any joint complete all as specified and directed. |