Limited Tender Enquiry For Lt Switchgear For Ukai Boiler R And M Project As Per Nit Letter , Break-Up Of Lt Switchgear (Complete Scope) , Modification In Gvdc U#3 , Modification In Bvdc U#3 , Modification In Unit Swbd U#3 , Modification In Sb Mcc U#3 , Modification In Dcdb U#3 , Modification In Emergency Mcc U#3 , Modification In Bvdc U#5 , Modification In Unit Swbd U#5 , Modification In Sb Mcc U#5 , Modification In Dcdb U#5 , Modification In Emergency Mcc U#5 , Mandatory Spares As Per Annexure-E Of Technical Specification , Bus Bar Support Insulators Of Each Type , 40 Mm Round Insulator , Two Way Insulator , Control Busbar Support Chanel , Vertical Busbar Support Big , Vertical Busbar Support Small , Breaker Control Switches Of Each Type , 16A, 240V Ac, 4 Pole , 2 Position Sel. Switch ,Base Type , Indicating Lamps/ Leds , Red Indication Lamp-240V Ac , Yellow Indication Lamp-240V Ac , Blue Indication Lamp-240V Ac , Red Indication Lamp-110V Ac , Green Indication Lamp-110V , Ac Amber Indication Lamp-110V , Ac Red Indication Lamp-220V Dc , Green Indication Lamp-220V Dc , Blue Indication Lamp-220V Dc , White Indication Lamp-220V Dc , Amber Indication Lamp-220V Dc , Cts Of Different Ratings And Type , Ct Rating-200/1A Cl-5P20 , Ct Rating-200/1A Cl-1 , Ct Rating-250/1A Cl-5P20 , Ct Rating-2501A Cl-1 , Ct Rating-300/1A Cl-5P20 , Ct Rating-300/1A Cl-1 , Ct 100/1A Metering, Cl-10 10Va Rasin Cast , Mcbs Of Different Ratings , Mcb 6A Dp-240Vac , Mcb 10A Dp-240Vac , Mcb 16A Dp-240Vac , Mcb 6A Dp-110Vac , Mcb 10A Dp-110Vac , Mcb 16A Dp-110Vac , Mcb 6A Dp-220Vdc , Mcb 16A Dp-220Vdc , Mcb 6A 4P-240Vac , Mcb 6A Sp-240Vac , Mcb 10A Sp-240Vac , Breaker Closing Coil , Closing Coil 220 V Dc , Breaker Tripping Coil , Tripping Coil 220 V Dc , Breaker Fixed Contact Assembly , Main Fixed Contacts (Upper Terminals) , Spring Charging Motors , Spring Charging Motor , Arc Chutes Of Each Type , Arc Chutes , Arcing Contacts Fixed And Moving Type , Arcing Contacts (Set Of 1 No. Fixed 1 No. Moving 1 No.) , Power Contacts Of Each Type (A) Fixed, (B) Moving , ?Main Fixed Contacts (Upper Terminals) , Main Moving Contacts Assembly , Auxiliary Contact Assembly , Auxiliary Isolating Contact Assembly , Numerical Relays Of Each Type (2 Nos. Each) , Numerical Relay 7Sj66 , Thermal Over Load Relay, 5 Nos. Of Each Rating , ?Thermal Over Load Relay 7-10A , Thermal Over Load Relay 9.0 -13.0 , Thermal Over Load Relay 12.0 -18.0 , Thermal Over Load Relay 48.0 ~ 65 .0 , Current & Voltage Transducer , Current Transducer (Dc),4-20Ma, Dual O/P,Aux -220V Dc , Vtd , Terminals For Outgoing (Fgdo) , Fgdo-160A , Fgdo-250A , Energy Meters, Ammeter, Voltmeter , Tvm , Multifunction Meter 3Ph, 4W Aux.-220V Dc With Pulse Output &Communication Facility , Ammeter Ratio-100/1A Sq96, Taut Band, 90 Degree Diff., Acc. Cl.1.0 , Ammeter Ratio-800/1A Sq96, Taut Band, 90 Degree Diff., Acc. Cl.1 , Mccb , Mccb Tp Adj O/L & S/C-16 , Mccb Tp Adj O/L & S/C-32A , Mccb Tp Adj O/L & S/C-125A , Mccb Motor S/C -16A , Mccb Motor Tp S/C-125A , Mccb Tp Adj O/L & S/C 200A Tm Based-250A , Push Buttons , Push Button-Spring Return With 1No+1Nc Aux, Contact , E Push Button-Spring Return With 1No+1Nc Aux, Contact , Power And Auxiliary Contactors , 3P Power Contactor-16A , 3P Power Contactor-32A , 3P Power Contactor-65A , 3P Power Contactor-80A , Auxiliary Contactors Ac , Auxiliary Contactors Dc , 24V On-Off Relay (Interposing) -10% Or Minimum One Of Each Rating And Type Of Installed Quantities