Tender For Electrification Of Record Room Revenue In Collectrate District Muzaffarnagar - Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed M, Saharanpur-Uttar Pradesh

Tender Notice

51689441
Tender For Electrification Of Record Room Revenue In Collectrate District Muzaffarnagar - Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed M
Tender
Indian
Uttar Pradesh
Saharanpur
15-10-2025

Tender Details

Tender For Electrification Of Record Room Revenue In Collectrate District Muzaffarnagar - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 2 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 3 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 4 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2x1.5sqmm+1x1.5sqmm earth wire 5 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2x2.5sqmm+1x2.5sqmm earth wire 6 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 7 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 8 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 9 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 10 Supplying and fixing of following sizes of medium class 25 mm PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 11 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet 12 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet 13 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 14 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 15 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 16 Supplying and fixing PVC batten/ angle holder including connection etc. as required. 17 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 18 Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. 19 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 20 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 21 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections, etc. as required. 22 Suppling and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including provinding and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 23 Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100Amp.,30KA,FP MCCB 24 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 Way ,Double door 25 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 Way ,Double door 26 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4+12), Double door 27 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4+12), Double door 28 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.single pole 29 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole 30 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A 31 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 32 Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 33 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 34 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 35 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 36 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 37 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 38 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 39 Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. 40 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 41 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 42 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 43 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 44 Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. 45 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3.5x185 sqmm 46 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4x95 sqmm 47 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4x 16sqmm 48 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4x 10sqmm 49 Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. 50 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 51 Supply & Fixing of Wall Bracket Fan 400 mm Make Havells/Crompton 52 S/f Exhaust Fan300 MM Make Havells./Crompton/usha/etc HD 53 S/f Exhaust Fan300 MM Make Havells./Crompton/usha/etc 54 S/f Of LED Bulb 9w/12w 55 S/F of LED Tube light with batten suitable for up to 1x22 watt LED tube light complete including tube etc on surface complete in all respect. Make Havells 56 Supply and fixing ofrecess/ Surface/ Pendent mountinground 10to15WattLEDDownLighter havingPowdercoateddiecastaluminiumhousing with heatsink,diffuser/Reflectoranddriverset complete in all respect. CAT- AAA 57 Supplyandfixingof36Wattto46Wattindoor Recess mounting LED Square Fitting for Armstrong CeilinghavingPowdercoateddiecastaluminium housing body withextended heat sink and diffuser of SpecialPolycarbonatemeterialanddriverset complete in all respect.CAT-AAA 2x2 58 S/F of LED Street light fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 watt .confirming to IP 65 and above protection complete in all respect. 59 Supply & fixing of 8 mtr GI Octagonal pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thick) having 3mm thickness withsinglearm bracket 1 mtr length in 1:2:4 RCC foundation bolt including the required T&P complete in all respect. 60 Supply andfixingof decorative8to16WattLED bollardluminaire with driverset confirming toIP 65 protection complete in all respect 61 Supply andfixingof decorative40to45WattLED Post Top luminaire with driverset confirming toIP 65 protection complete in all respect 62 Supply and fixing ofwater tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in allrespect. 63 Supply and fixing ofSingle LED light wall bracket 3 to 6WattonmatchingM.D.F.E.GBoardbaseetc. complete in allrespect. 64 Supplyandfixingofshocktreatmentchart(prescribed underI.E.rules)dulyframedwithglassandsupported fromback withhardboard or soft boardwithsupply of all material labour T&P for proper completion of work. 65 Supply and Laying of185sqmm 3.5 Core Aluminium Conductor PVC insulated armoured served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by Engineer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 66 Supply and Laying of95sqmm 3.5 Core Aluminium Conductor PVC insulated armoured served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by Engineer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 67 Supply and Laying of16 sqmm 4CoreAluminium Conductor PVC insulated armoured served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by Engineer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 68 Supply and Laying of10 sqmm 4CoreAluminium Conductor PVC insulated armoured served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by Engineer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 69 S&F of100 AMP four pole Mouled case type on load change over switch with enclosure including the cost of labour, T & P andmaterialreuiredfor propercompletionof the work as per direction and satisfaction of Engineer an charge. 70 S&F of320 AMP four pole Mouled case type on load change over switch with enclosure including the cost of labour, T & P andmaterialreuiredfor propercompletionof the work as per direction and satisfaction of Engineer an charge. 71 Supply &Erracetionoffactory fabricated&wired metalcladdustandverminprooffloormounting,M.S. Channel Base with bottom and top cable entreisElectricalcontrolpanelwithTPNMCCBs (FourPole36KAwiththermalmagnatic release)Switches Complete andinstrument chamber etc.complete in all respects. The instrument chamber shallbeseparateandshallcompriseofflushtype digitalmeteringsystemforphasetophasevoltage andsinglephasevoltage,currentandother parameters(KVA,P.F,KWetc)ineachphasewith touchtypeselectorswitchesfordifferentreadings, instrument fuses, current transformer etc. The panel boardshall havesuitablecapacity electrolytic alumininum busbars as perIS8623 orabove istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC supportwithdeteachablesidecoversandshallbe suitableforextensiononthesides.TheMCCBs shallbecompletewithsuitablecableendboxes, compressionglandsandindicatinglampon incoming etc.The Jobincludesthe grounting oftheboardas perdirectionsofEngineer-incharge.Alloutgoingsof 100AmpandaboveshallhaveanAmmeter.The panelboardshallbefabricatedwithCRCAsheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.Incoming 400 Amp MCCB Outgoing 200 Amp-01, 100 Amp-02,63 Amp-01, 72 Supply &Erracetionoffactory fabricated&wired metalcladdustandverminprooffloormounting,M.S. Channel Base with bottom and top cable entreisElectricalcontrolpanelwithTPNMCCBs (FourPole36KAwiththermalmagnatic release)Switches Complete andinstrument chamber etc.complete in all respects. The instrument chamber shallbeseparateandshallcompriseofflushtype digitalmeteringsystemforphasetophasevoltage andsinglephasevoltage,currentandother parameters(KVA,P.F,KWetc)ineachphasewith touchtypeselectorswitchesfordifferentreadings, instrument fuses, current transformer etc. The panel boardshall havesuitablecapacity electrolytic alumininum busbars as perIS8623 orabove istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC supportwithdeteachablesidecoversandshallbe suitableforextensiononthesides.TheMCCBs shallbecompletewithsuitablecableendboxes, compressionglandsandindicatinglampon incoming etc.The Jobincludesthe grounting oftheboardas perdirectionsofEngineer-incharge.Alloutgoingsof 100AmpandaboveshallhaveanAmmeter.The panelboardshallbefabricatedwithCRCAsheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.Incoming 100 MCCB Outgoing 63 Amp-01,,32 Amp-02 73 Supply Installation Testing Commissing of NVR/DVR 16 Channel Make CPPLUS 74 Supply Installation Testing Commissing of Hard Disk 1TB Make Hp 75 Supply Installation Testing Commissing of Dom Camera 2.4 mpMake Cp plus 76 Supply Installation Testing Commissing of VF Bullet Camera 2.4 mpMake Cp plus 77 Supply Installation Testing Commissing of POE SwitchMake Cp plus 78 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. 79 Supply, Installation,Testing & Commissioning ofInput /Output Jack (Make- Schneider/AMP) 80 Supply, Installation,Testing & Commissioning ofEpabex System 16 Channel Complete all respect. 81 Supply, Installation,Testing & Commissioning ofTelephone Instrument Complete all respect. 82 1/2 port icon able face plate- white 83 Supply, Installation,Testing & Commissioning of 24 port CAT6 fully loaded si series patch Pannel IU (Make- Schneider/AMP) 84 Supply, Installation,Testing & Commissioning ofSlime lineRJ45 to RJ45 CAT6 UTP Patchcord with flexible transparent Boot (Data Rack End) = 1Mtr (Make- Schneider / AMP) 85 Supply, Installation,Testing & Commissioning of 9 u wall mountable open rack with front glass and rear ms door including with 3 socket 6/ 16 Amp PDU mounting hardware & fan tray (make - Comrack) 86 Supply, Installation,Testing & Commissioning of horizontel cable organiser /2U channel(Make- Schneider / AMP) 87 Sr No 1 to Sr No 86 amount 5126156 GST 18%@5126156X18%=922708

Key Value

Document Fees
INR 2354 /-
EMD
INR 460000.0 /-
Tender Value
INR 60.50 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.