| 1 | APPENDIX-A |
| 2 | Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes ( D S R10.16.1) |
| 3 | Providing and fixing plain multipurpose cement board(Hight pressuresteam cured) with suitable screws for cement particle board in ceiling, partitionetc. complete (frame work to be paid seperatately). 8 MM thick Cement fiber board as per IS: 14862(DSR12.26.1) |
| 4 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with: Gypusm Plaster Board of size 1200 x 2400 x 12.5 mm, with all 4 side tapered ( D S R2016 12.45.1. ) |
| 5 | Designing, fabricating, testing, installing and fixing in position CurtainWall with Aluminium Composite Panel Cladding, with open groovesforfor linear as well as curvilinear portions of the building , for all heightsand all levels etc. including: ( D S R25.7. ) |
| 6 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm (D S R11.41 .2 ) |
| 7 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxygrout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardenerand 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm ( D S R11.48.2. ) |
| 8 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete .( 2018 D S R 13.88) |
| 9 | Providing and applying Plaster of paris Putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete.( D S R 13.26) |
| 10 | Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface : Water thinnable cement primer (D S R13.43.1 ) |
| 11 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work ( D S R2018 , 13.52.1) |
| 12 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work.( D S R13.60.1.) |
| 13 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work.( D S R13.61.1 . ) |
| 14 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work. ( 2018D S R,13.99.1 ) |
| 15 | Finishing walls with Acrylic Smooth exterior paint of required shade:Old work (Two or more coats applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface (2018D S R13.111.1) |
| 16 | Providing and fixing Aluminium work for Doors,Windows,Ventilatorsand Partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, free, straight, mitred and jointed mechanically wherever requiredincluding cleat angle, Aluminium snap beading for glazing / paneling,C.P. brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) :For fixed portion - Polyester powder coated aluminium(minimum thickness of polyester powdercoating 50 micron) ( D S R21.1.1.3) |
| 17 | For Shutters of doors, windows & ventilators includingproviding and fixing hinges/ pivots and making provisionfor fixing of fittings wherever required including the costof EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Polyester powder coated aluminium(minimum thickness of polyester powdercoating 50 micron) ( D S R21.1.2.3 ) |
| 18 | Providing and fixing Double action hydraulic floor spring of approvedbrand and manufacture conforming to IS : 6315, having brand logoembossed on the body / plate with double spring mechanism anddoor weight upto 125 kg, for doors, including cost of cutting floors,embedding in floors as required and making good the same matchingto the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete asper the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mmthickness (D S R21.4.1.) |
| 19 | Supplying and Fixing Good Quality Stainless Steel DoorHandle ForGlass Doorof size45cm Withall necessary screws, nut boltsetccomplete as approved by the Engineer in Charge. ( Observed Data od 46046/2021-2022 ) |
| 20 | Disposal of building rubbish / malba / similar unserviceable, dismantledor waste materials by mechanical means, including loading,transporting, unloading to approved municipal dumping ground or asapproved by Engineer-in-charge, beyond 50 m initial lead, For all leadsincluding all liftsinvolved. ( D S R2018 , 15.60) |
| 21 | Supplying and Fixing Openable Glass door lock of approved quality and make (EBCO OR EQUIVALENT ) with all necessary accessories etc complete. od20254/2024_2025 |
| 22 | LABOUR ENGAGED FOR REPAIR WORK PLUMBER/FITTERod20255/2024_2025 |
| 23 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishingand making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railingwith necessary accessories & stainless steel dash fasteners , stainlesssteel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall beconsidered excluding fixing accessories such as nuts, bolts, fastenersetc.).( D S R10.28)ForRepairofExistingSSRacks |
| 24 | LABOUR ENGAGED FOR REPAIR WORK,Beldarod20255/2024_2025 |
| 25 | Supplying fabricating and fixing in position Sales counterwithGranite /Glasstopof60 CM TOP WIDTHANDHEIGHT80 CM ( AV ) ,made with frame work of 16 mm BWR(IS303GRADE )Plywoodincludingcoveringthe front and SIde , Providing inside Racks using16 mmBWR ( IS 303GRADE ) Ply wood,Coveringall the exposedsurfaceusing1.00 mmthickness decorative Laminatedsheet with Texture Finishofapproved brandwith suitable adhesive ( HEATEXor equvqlent ), the insideof the counter being painted with synthetic enamel paint 2 coat over one coat of wood primerand putty leveling, filling etc.Providing12 mm thicedgepolishedglass/18 mm thickegde polished Granite for the Top area with necessary glasscaps or adhesives, providing8 mm thickedge polished glass for the frontvertical area withsuitableDbrackets , Finishingincludingpolishing all the exposedarea completeas per the approved drawings anddirection of the Engineer in charge..(OBSEVED DATA od3_P100001/2019-2020 ) |
| 26 | Supplying and fixingModiguardorEquivalentBrand glass Mirror over Frame work of16 mmBWRQualityIS303Grade Play woodframe and covering the rear side with 12MM BWR plywood and finishingall theexposedsurfacewith 1.00 mmThicknessDecorativeLaminatedSheetsWith Texture Finishofapprovedbrandandshade, FixingonWall etc. complete as per the direction of Engineer in charge. |
| 27 | Providing and Fixingplywood Back groundpanel made out ofFRAMEworkusing16 mmBWRQUALITY( IS303grade )plywoodat suitable spacingboth horizontally and vertically, including making hole in the concrete/ masonry wall, with necessary SS hold fasts or SS screws of necessary size. ThenCommercialplywood12 mm thick B W R grade (IS 303 Grade )of approved make is fixed to the Exposedside of theframe work with screws of necessary size , all the exposed surface coveredby1.00 mmthickness Decorative LaminatedSheetswithsuitable adhesive ( Heatex or Equivalent )includingsealing all the joints and holes all as per the approved drawings andDirection of the Engineerin Charge . |
| 28 | Providing and fixing Glazing in Aluminium Partitionsdoor, window and ventilator shuttersetc. with EPDM rubber / neoprene gasket etc. complete asper the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item): With TOUGHNED GLASS panes of 12 mm thickness |
| 29 | Providing Name Board by Vinyle Sticker Work on ExistingACPPANNEL WORK as per approved Design |
| 30 | Providing and fixingWOODENDisplay shelffor Ornamental Items(RACK BEHINDCASH COUNTER)withframe work using 16 MMBWR( IS 303 GRADE )PLY WOOD , providing12 mm thick (IS 303 GRADE )BWRply woodon rear side,covering the frame workwith16 mm ( IS 303GRADE )BWR ply wood,covering the exposedsurface withsuitablethickness Decorativelaminatedsheets ofTexture Finish withaddhessiveof approved brand (HeatexorEquivalent ) , providing12mmthickedgemechinepolishedglass forrackswith necessary supports in theupper portion,providing 16 mm thickBWR(IS 303GRADE ) PLY WOODSHUTTERS INCLUDINGNECESSARYHINGES ,HANDLESETCfor racksin thelower area, applying 1 coat of wood primer ,putty finishing, syntheticenamel 2 coatall as per the drawing and Direction of theEngineer in Charge . |
| 31 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.GROUPB ( D S RELECTRICAL1.10.2) |
| 32 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required(DSREectrical 2018, 1.55.3) |
| 33 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm (D S RELECTRICAL1.17.3) |
| 34 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm(D S RELECTRICAL1.17.12) |
| 35 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm( D S RELECTRICAL1.17.21) |
| 36 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 MM( D S RELECTRICAL1.21.1) |
| 37 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25MM( D S RELECTRICAL1.21.2) |
| 38 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch(D S RELECTRICAL1.24.1) |
| 39 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch( D S RELECTRICAL1.24.3) |
| 40 | Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator (ODElectrical90.10.3.15) |
| 41 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet(D S RELECTRICAL1.24.4) |
| 42 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet(D S RELECTRICAL1.24.5 ) |
| 43 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.(D S RELECTRICAL1.26) |
| 44 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)( D S RELECTRICAL1.27.1) |
| 45 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)( D S RELECTRICAL1.27.2) |
| 46 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6Module( D S RELECTRICAL1.27.4) |
| 47 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12Module (200mmX150mm)(D S RELECTRICAL1.27.6) |
| 48 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). ( D S RELECTRICAL1.31) |
| 49 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCBIRCCB/Isolator2+12 way, Double door )( DSR ELECTRICAL2.3.8.) |
| 50 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. SinglePole( D S RELECTRICAL2.10.1) |
| 51 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required (D S RELECTRICAL2.11) |
| 52 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. ( 40Amps)( D S R2.12. 1) |
| 53 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. ( 63Amps)( D S R2.12. 2) |
| 54 | Supplying and fixing following rating,Doublepole, (Singlephase and neutral), 240volts, Residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63Amps(D S RELECTRICAL2.14.3.) |
| 55 | Supply, Conveyance , Installation, testing and commissioning of Wall mounting fan of 400 mm Sweep with Oscillation System and Pull Cord, Fixing to wall with wall mounting brackets supplied along with the fan and Giving Connections with Existing wire etc. complete. od28805/2023_2024 |
| 56 | Supply Conveyance, installation, testing and commissioning of sleek compact recess mounting LED Slim Panel Light Fitting 18 W, Square or Round, Cool or Warm,size 205 mm or nearest available , with light weight body, energy efficient drive , complete with all accessories , fixing directly on ceiling including giving connections with required length of 3 core round copper conductor flexible wire confirming to the relevant ISS or extending the original wire etc. as requiredod28806/2023_2024 |
| 57 | Supply Installation , testing , Commissioning of Sleek Compact Recess Mounting, LED Slim Panel Light Fitting Square or Round, Cool or Warm, 12w ofsize 155 mm or Nearest available size, with Light Weight Body, Energy efficient Drive, with all accessories, fixing directly on ceiling including giving connections with required length of 3 core round copper conductor flexible wire confirming to relevant ISS or extendingthe original wire etc. as required od28807/2023_2024 |
| 58 | Supply Conveyance, Installation, Testing and Commissioning of Sleek Compact Recess Mounting LED Slim Panel Light Fitting 6 w , Square or Round , Cool or Warm, Size 105 mm or nearest available size, with Light weight Body , Energy Efficient Drive,complete with all accessories, fixing directly to the Ceiling including giving connection with required length of 3 core round copper conductor flexible wireconfirming to relevant ISS or extendingthe original wire etc. as required od28808/2023_2024 |
| 59 | Supply, Conveyance, Installation, Testing and Commissioning of Sleek , Compact Recess Mounting LED Slim Panel Light Fitting 3W or 4W, Round or Square, Cool or Warm, Size 75 mm or nearest available , with Light weight Body, Energy efficient Drive,complete with all accessories ,fixing directly on ceiling, Giving connections with required length of 3 core copper conductor flexible wire confirming to relevantISS or extendingthe original wire etc. as required od28809/2023_2024 |
| 60 | Supplying and drawing following sizes of CC TV CABLE in theexisting surface / recessed steel/ PVC conduit as required. - 3 +1 CC TV CABLE PURE COPPER OF BRAND D LINK OR EQUIVALENT BRANDS APPROVED BY THE ENGINEER IN CHARGE. |
| 61 | SupplyandFixingandcommissioning of2 MPHDCAMERAHIKVISION( DS -2CE 16 DOT-ITPFS ,3.6 MM) with all necessaryfittingsandaccessories |
| 62 | Providing M SDISPLAY RACKSin Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including weldinggrindingand bolted with special shaped washers etc. complete.Hot finished welded type tubes ( D S R10.16.1) |
| 63 | Providing and fixing8.00 mm thick FloatGlasspanesasracksinMSDisplayRacks , Display Standincludinggrindingandpolishing theexposed edgesetccomplete as per the architectural drawings and the directionsof Engineer-in-charge |
| 64 | Modifications and Repairs to Existing Plywood Furniture ( Sales Counters and Cash Counter ) by providing required 12 mm thick IS 303 Grade Plywood with necessary nails, screws, adhesives , including all labor charges , charges for rectification of damages etc complete as directed by the engineer in charge |
| 65 | Providing and Fixing 1 mm thick ISI Marked Approved Quality , Color , and Design Laminated Sheets with Texture Finish ( MICA ) on existing surface with good quality Adhesive ( Heatex or Equivalent ) as directed by the Engineer in charge |
| 66 | ENGAGING LABOUR FOR REPAIR WORK CARPENTER GRADE 1 (od155107/2024_2025) |
| 67 | DismantlingExistingCCTVSystemKattappanaOld KGSandInstalling, TestingandcommissioningatNewKGS Kattappana withallnecessaryfittingsas requiredasdirectedby theEngineerinCharge |
| 68 | Providing and Fixing 12 mm thick Edge Polished Glass as Counter Top withstainless steel studs with necessary screws etc complete . |
| 69 | Dismantling , Loading, Convayance, Unloading , andplacingof ExistingRacksandCountersatExistingKattappanaKGStoNewKGS atKATTAPPANAIncluding DismandlingofGlasstops,Racks,GraniteTopsEtccarefully,Packingofthesame, refixingall at NewKattappanaKGSwithoutanyDamage. |