}

Tender For Improvement Of E.I. & Fan In Newly Constructed Class Room And Toilet Block In M.C. Pry. School Kucha Moatter Khan Morigate Under Cspz., Delhi-Delhi

Municipal Corporation Of Delhi has published Tender For Improvement Of E.I. & Fan In Newly Constructed Class Room And Toilet Block In M.C. Pry. School Kucha Moatter Khan Morigate Under Cspz.. Submission Date for this Tender is 17-10-2025. Electrical Maintenance Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

51677854
Tender For Improvement Of E.I. & Fan In Newly Constructed Class Room And Toilet Block In M.C. Pry. School Kucha Moatter Khan Morigate Under Cspz.
Tender
Indian
Delhi
Delhi
17-10-2025

Tender Details

Tender For Improvement Of E.I. & Fan In Newly Constructed Class Room And Toilet Block In M.C. Pry. School Kucha Moatter Khan Morigate Under Cspz.; 1 Wiring for light point /fan point /exhaust fan point /call ball point with 1.5sq.mm FRLS PVC installed copper conductor single core cable in surface / recessed steel conduit, with modular switch,modular plate , suitable size G.I. box and earthing the point with 1.5sq.mm. FRLS PVC installed copper conductor single core cable etc as required. Group C 2 Rewiring for light point /fan point /exhaust fan point /call ball point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/ pvc conduit i/c dismentaling as reqd. etc as required.Group C 3 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. A.20 mm 4 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessedmedium class PVC conduit as required. A 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 5 (b)2 X 4 sq. mm + 1 X 4 sq. mm earth wire 6 Supply and fixing of following piano type swich/ socket on the existing switch box/ cover including connection etc as required. 7 (a) 5/6amps switch 8 (b)15/16 amps switch 9 © 3 pin 5/6 amps socket outlet 10 (d) 6 pin 15/16 amps socket outlet 11 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 12 (a) 200 mm X 300 mm X 100 mm deep 13 Supply & Fixing of phenolic laminated 3 mm thick sheet i/c cutting as reqd. 14 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(a) 8 way, Double door 15 (b) 12 way , Double door 16 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. A Single Pole 17 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 amps 18 (b)40 amps 19 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.(a)Upto 35 sq. mm 20 Laying of one no PVC insulated and PVC sheathed/XPLE Al Conductor armoured power cable of 1.1KV grade of following sizeon wall surface as required. Up to 35 sq,mm (clamped with 1mm thick saddle) 21 Supply of XLPEinsulated and PVC sheathed armoured cable of 1.1KV grade conforming to IS 1554 part-1 as required. A. ( 2x10 sq mm) 22 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/ coke and salt as required. 23 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 24 Supply, Installation, Testing and Commissioning of ceiling fan with BrushLess Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, steel/Al body Power Factor not less than 0.9,Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS :374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remainingaccessories including safety pin, nut bolts, washers, temperature rise=75degree C (max.), insulation resistance more than 2 mega ohm, suitable for230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fanSupply, earthing etc. complete as req. 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min(Minimum) 25 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 26 Supply of 15(380mm)sweep 1400 rpm heavy duty Exaust Fan complete with ring, blade etc as required. ISI marked. 27 SSupplying, installation, Testing & Commissioning of LED surface mountedBatten light of following body material and construction as per IS : 10322 withdriver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short &Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flickerfree (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)<3, Maximum power consumption should not more than the specified ratingand Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screenprinting on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEMwarranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80Test report from NABL lab for all testing required for LED fixtures asper BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sinkof aluminium housing such that LED junction temperature shall not rise above 90°C). (a) 18-22 Watt 28 Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres 29 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting andcutting, jointing etc..direct in ground (75 cm below ground level)including excavation and refilling the trench but excluding sandcushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) 30 Supply and fixing of 32mm dia X 1 meter long G.I. Pipe (Medium Class) bracket for mounting of fluorescent/HPMV/HPSV Street Light fitting on pole including bending the pipe to the required shape , 2 nos 25mm X 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd. 31 Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI EMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximumpower consumption should not more than the specified rating and Fixtureshall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single corecable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shallbe submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink ofaluminum housing such that LED junction temperature shall not rise above 90°C). 70Watt 32 supply of single phase monoblock pumpset complete with all accessories workable on 240/415 volts 50HZac supply (a) 1 HP (.75KW) single phase pump set head ffrm 12-30 mtr suction and delivery 25X25 mm

Key Value

Document Fees
INR 590 /-
Tender Value
INR 3.71 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail