| 1 | Sch \"A\" |
| 2 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed. |
| 3 | M&L 75mm thick PCC 1:4:8 Type D-2 using 40mm graded crushed stone aggregate as in sub base offloor complete all as specified and directed. |
| 4 | M&L chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick set, jointed and pointed in neat cement slurry in floors with grey cement and pigment , over and incuding 20mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 5 | M&L 60mm thick interlocking paver block with grey cement and pigment of any size and shape confirming to IS 15658-2006, M-35 Grade as approved laid in flooring and joints filled/broomed with fine sand complete all as specified and directed. |
| 6 | M&L for Sand filling underfloors or in foundations complete all as specified and directed. |
| 7 | M&L cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate provided in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. |
| 8 | Demolition of brickwork built in cement or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articlescomplete all as specified and directed. |
| 9 | M&L brick work with sub class \"B\" bricks straight or curved on plan exc. 6 mtr mean radius built in CM 1:6 complete all as specified and directed. |
| 10 | All as per item No 8 above but except bricks complete all as specified and directed (Old bricks shall be reused). |
| 11 | M&L Brick work with sub class ‘B’ brick in CM 1:4 straight or curved on plan to any radius in half brick thick wall complete all as specified and directed. |
| 12 | All as per item No 10 above but except bricks complete all as specified and directed (Old bricks shall be reused). |
| 13 | Racking out Joints/Pointing to brick work in walls or to brick on edges in floors channels roofs etc complete all as specified and directed. |
| 14 | M&L for Flush pointing to brick walls in cement and sand mortar (1:4) complete all as specified and directed. |
| 15 | M&L for Plain cement contreate type B-I using 20mm graded crushed stone aggregate as in surface channels and benching to drains complete all as specified and directed. |
| 16 | Extra for forming fair finished drain or channel30cminnergirthincement concrete, using extracement including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 17 | Dismantling of RCC Post any section, embedded in natural ground including taking out embedded portion in natural ground complete all as specified and directed. |
| 18 | Excavation in post holes (or similar holes) each not exceeding 0.50 cubic meter in any typeof soil , getting out, returning filling in watering and ramming earthor broken rubble mixed with earth around inlayers not exceeding 25 cm and removing surplus soil to a distance n.exc 50 mtr and making good surface complete all as specified and directed. |
| 19 | M&L PCC1:3:6, type C-2 using 40mm graded crushed stone aggreage in foundation filling and mass concrete complete all as specified and directed. |
| 20 | S&F post and strut in fencing including cutting tops to shape as directed drilling holes notching for wire flat iron fillet ( for securing wire mesh) including all necessary drilling bolting and rivetting conforming to Fe-290Gd-165 complete all as specified and directed. |
| 21 | S&F mild steel screw bolt (maching made) with hexagonal or square head at one end and screwedthe other with washer n.exc 5 cm long dia bolt 5 to 10mm complete all as specified and directed. |
| 22 | Dismantling of steel barbed wire of any thickness and in any position, complete all as specified and directed. |
| 23 | Supply only Chain link MS galvnised fencing , any size or type, complete all as specified and directed. |
| 24 | Labour for Fixing only chain link fencing including line wires, any mesh, size and type to any type ofstandards,rails,strainingbolts,etc. including provision of binding wire complete all as specified and directed. |
| 25 | S&F galvanised2 strand, steel barbed wire 2.24mm dia, barbed with 2.24 mm dia barbed at 75 mm spacing c/cand straining and fixing to any type of standard rails, strainingbolts, including securing and tying at crossings with provison of galvisnised mild steel wire, staples or steel pins etc., complete all as specified and directed. Note : Net length of wire shall be measured. |
| 26 | M&Ltwo coats of synthetic enamel paint on new surface of steel and iron surfaces of any description over 10 cmwidth or girth over a coat of red oxide primer including prepration of surface complete all as specified and directed. |
| 27 | M&L for mild steel TMTbars 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoopingas in straightening bars for chain link fencing complete all as specified and directed. |
| 28 | Taking down cement plaster of any description on brick or concrete surfaces etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 29 | M&L 15mm thick rendering on external wall of brick work or concrete surfacesin cement mortar 1:4 finished the surfaces even and fair complete all as specified and directed. |
| 30 | M&L two coats cement base paint including preparation of newly plastered surfaces complete all as specified and directed. |