Tender For Term Contract For Removal Of Construction, C And D Waste From Cantonment Area To Comply With Delhi Pollution Control Committee Orders, In Delhi Cantonment.; 1 Supply, installation , testing and commissioning of end suction & top discharge, non self priming , single phase, centrifugal volute type pump having cast iron casing, enclosed type dynamically balanced phosphor - bronze/ SS impeller , hight tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep grove ball bearings, TEFC squirrel cage induction motor having IE-3 efficency, confirming to IS 12615-2018 at 2900 RPM speed star/delta starter panel, base plate, mounting chanel frame, accessories and fittings, viz mechanical seal, pressure gauges, thermometer , drain, coupling, coupling gaurd, vibration isolation arrangement by means of spring/ rubber type mounting suitable for operation no 3 phase, 415V +10% , 50 Hz AC supply including foundation as per manufacturer recommendation complete all as specified and directed by Engr in Charge. 2 Horizontal end suction long coupled pump with insulation 7.5 LPS water flow rate at 26 mtr head for domestic supply. 3 Horizontal end suction long coupled pump with insulation 9.3 LPS water flow rate at 45 mtr head for domestic supply. 4 Horizontal end suction long coupled pump with insulation 34 LPS water flow rate at 75 mtr head for domestic supply. 5 Supply, fix, install, testing and commissioning of LT Panel,indoor type cubical shape,three phase, 4 wire, copper bus barrating 400 amps for phases and 200 amps for neutral made out of CRCA sheet ,2 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frameand four legs of 50x50x6mm thick angle iron ,1 ft long grouted on PCC foundation of height not less than 40 cm from the ground level , grouting properly ,and of suitable size to accommodate the items mentioned belowand having separate compartment /chambers for cable gallery busbar,switch gearand front side door openable , back side fixedwall etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc with the following accessories:-(i) MCCB 4 Pole, 415V, adjustable type, 250 Amps with breaking capacity 25KA -01 No (Incoming)(ii)MCCB 4 pole 415V fixed type, 25 to 160 Amps with breaking capacity 16KA-03 Nos (outgoing) (iii)Motorstar delta startersuitable for UPTO 40HP motor - 02 Nos(iv) Voltmeter/ Ammeter,digital type 0- 400 volt,with selector switch -03 set(v) Phase indicating lamps LED type ( red , yellow, blue) -03 set(vi)MCB SPN 40 Amps- 06 Nos (outgoing) 6 Supply, install, testing and commissioning of motoron /off LT PanelCPRI Approved mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type, with frontside opening or suitable fixing of all breakers and controls for 415V, 3 phase,made of 2 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 600 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections Panel and fixing/connecting in new installed panel with provisions of thimble/lugs and necessary framework and PCC foundation including shifting of existing LT Panel of any making arrengement for fixing of panel and making good to disturbed surface as directedcomprising of the following :-(a)Motorstar delta startersuitable for UPTO 12.5HP motor - 02 Nos(b) MCCB 250Amps, 36 KA FP - 01 Nos (c) MCCB 100Amps, 36 KA, FP - 04 Nos (d) control panelwiring with 2.50 sq mm multistranded, pvc insulated copper conductor cable between voltmeter, Am meter, and their selector switch complete withCTs of ratio 400/5A- 2 Nos,320/5 A- 2 Nos , 250/5 A- 2 Nos ,200/5 A - 2 Nos , 160/5 A - 2 Nos , voltmeter flush pattern type 96 mm square dial -1 nos, Am- meter digitalCT operated 96 mm sqare dial flush pattern type -10 Nos, indication lamp for 3 phase and control fuses-3 Nos complete .(e) Aluminium bus bar 400 Amps for phase & 200 Amps for neutral complete with bus bar insulator,nuts & bolts complete.(f) Power panel wiring between bus bar to MCCB of different capacity with PVC insulated multistranded copper cable , 10 Sqmm ,singlecore ,1100 volts grade of appropriate size complete with copper lugs.(g) Digital Ammeter-03 No(f)Digital Voltmeter-03 No (g) Phase indicator lamp R,Y & B with slector switch - 03 Set 7 S&F in repair, testing and commissioning weather and vermin proof factory made manufactured by a CPRI approved factory, floor mounted, out door cubicle type double doortotally enclosed LT panel fabricated out of 3 mm thick CRCA sheetwith extended hood to arrest rain beat with MS angle iron frame made out of angle iron 45 x 45 x 6 mmsuitable for operation on 3 phase 4 wire 415 volt 50 HZ system, dust & vermin proof, front and rear operated, hinged panel doors coverstwo sides openablewith handles , locking arrangements and consisting of sufficient number of cable cutting holes at bottom for inserting incomming /out going cables with suitable PVC /Rubber bushes to arrest entry of water /vermin etcand fixed with chromiumplated brass cable glands to connect the cables of suitable sizes internal power wiring, adequataluminium strips for bus barsand stranded copper cables size suitable to the capacity of MCCBs an other controls including internal compartments using 3 mmthick CRCA sheet metal powder coated connecting all cables properly and consisting of the following controls and fitment in LT panel complete all as directed by Engineer - in -charge. 8 INCOMING(a) MCCB 250A, rated for 415Volt, 4 pole, 3 Phase, rupturing capacity of 36KA, Thermal-Magnetic type MCCB, Qty-01 No (. incoming), the service short circuit breaking capacity (Ics) shall be equal to ultimate breaking capacity (Icu) i.e. Ics =100% Icu. (Thermal adjustment and magnetic adjustment setting) (b)Bus bar of aluminium strip of suitable cross section to with stand 250 Amps rating 3 phase and half of the phase capacityfor neutral mounted on Epoxy/FRP bus bar insulator and colour codingOUTGOING :(a) MCCB 160A, Rated for415Volt, 4 pole, 3 Phase rupturing capacity of 16KA, Thermal-Magnetic type MCCB, Qty-04 No. (Outgoing) the service short circuit breaking capacity (Ics) shall be equal to ultimate breaking capacity (Icu) i.e. Ics =100% Icu. Fixed Thermaland magnetic setting (b) MCBSPN , 230 Volts, 63 Amps,10 KA -04 Nos (c) Indicator lamp (RYB) (set of three) - 01 Set (d) Digital Ammeter 0-200 Ampswith selector switch - 01 No (e) Digital Voltmeter 0-500 V with selector switch - 01 No.(f) Earting studs welded on body of pillar box- 02 Nos(g) Indicator lamp RYB LED Type(h) Necessary cable glands/cable lugs of suitable sizes. (j)Angle iron mounting support made of 50 X 50 X 6 mm including grounting in PCC 1:2:4, 4 lugs 60 cm height gounted 15 cm in ground including earth work complete (k) Testing and commissioning for insulation and earthing complete. 9 M&L for Construction ofbrick masonry valve pit chamber of size (105 x 105 x 105cm (finished internal dimensions ) using sub class Bbrick masonry in cement mortar cm 1:4 including plastering internally in CM 1:4 including1:4:8 using 40 mm gradedaggregate over 100 mm hardcore and painted flush externally as the work proceeds and PCC 1:2:4 type B-1 as in coppingwith repair/welding ofangle iron frame 40 mm x 40 mm x 6 mm with 2 mm thick MS sheet cover two side openwith 2 Nos hinges each side and 2 Nos lifting handle and in built locking arrangement including lock and key and surface with two coats of synthetic black paint and a coats of red oxide paint on steel surface including necessary excavation in any type of soil, earth work in any type of soil to distance n.exc 50 m all as specified also included in this schedule of rate including returning/filling of earth and removingsurplus soil as decided. 10 S&F in repair 200 MM ISI marked MS ERW pipes with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer, including supporting/fixing the pipe on floor/wall/ceiling with clamps, hangers, angles, channels (using anchor fastners) with painting of one coat primer and 2 or more coats of synthetic enamel paint complete all as specified and directed by the engineer-in-charge. 11 S&F in repair 150 MM ISI marked MS ERW pipes with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer, including supporting/fixing the pipe on floor/wall/ceiling with clamps, hangers, angles, channels (using anchor fastners) with painting of one coat primer and 2 or more coats of synthetic enamel paint complete all as specified and directed by the engineer-in-charge. 12 S&F in repair 100 MM ISI marked MS ERW pipes with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer, including supporting/fixing the pipe on floor/wall/ceiling with clamps, hangers, angles, channels (using anchor fastners) with painting of one coat primer and 2 or more coats of synthetic enamel paint complete all as specified and directed by the engineer-in-charge. 13 S&F in repair 80 MM ISI marked MS ERW pipes with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer, including supporting/fixing the pipe on floor/wall/ceiling with clamps, hangers, angles, channels (using anchor fastners) with painting of one coat primer and 2 or more coats of synthetic enamel paint complete all as specified and directed by the engineer-in-charge. 14 M&L for PCC 1:3:6 type C2 (using 40 mm graded crushed stone aggregate) for filling in hard standing/ plinth protectionofsemi under tank and suporttomain raw water supply lineallas directed by Engineer-in-Charge. 15 Supply and fix in repair GI tubing medium grade in trenches including provision of fitting and accessories in trenches/wall/shaft for diversion and improvement in water supply line complete all as specified and directed by Engineer-in-Charge for the following sizes:- 16 40 mm bore 17 50 mm bore 18 80 mm bore 19 100 mm bore 20 150 mm bore 21 Excavationin trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and taking out soft/loose soil for laying of cable /Laying of pipe/evection of pole/stay pit excavation eomplete all as specified and directed by Engr in Charge. 22 Returning and filling including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by Engr in Charge. 23 Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specifed and directed by Engr in Charge.