Tender For Spl Repair Tobldg No P-46 (Csd) Of Hq 69 Mtn Bde At Ghunghora Under Ge Dehradun; 1 M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished surfaces even and smooth includingtaking down cement plastering of any description on brick/stone/concrete wall surfaces of any description incl racking out joints hacking for key,scrubbing down with water etc. complete all as specified and as directed.complete all as specified and as directed 2 M&L for rendering 15 mm thick in cement mortar 1:6on fair faces of brick work or concrete surfaces finished surfaces even and smooth includingtaking down cement plastering of any description on brick/stone/concrete wall surfaces of any description incl racking out joints hacking for key,scrubbing down with water etc. complete all as specified and as directed.complete all as specified and as directed 3 M&L for preparation of wall and applying interior grade acrylic water proof wall care putty 2mm thick to make the surface smooth complete all as specified and directed . 4 M&L for applyingtwo coats of distemper oil emulsion over a coat of suitable primer including preparation of new surfaces of wall etc, complete all as specified and directed. 5 M&L for applyingtwo coats of oil bound distemper in any tint on wallsincluding preparation ofold plastered surfaces by brooming down with corewire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and finally clean with sand paper complete all as specified and directed 6 M&L forprepration of new plastered surface and applying Two or more coatsof 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance asper IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including primingcoat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces complete all as specified and directed. 7 M & Lfor complete removal of existing treatment of old plastered surface and applying Two or more coatsof 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including primingcoat of exterior primer applied @ 0.90 litre/ 10sqm including preparation of surfaces complete all as specified and directed. 8 M&L for 25 mm thick PCC1:2:4 type B-1 ( using 20 mm graded stone aggregate) incl demolition of old concrete complete all as specified and directed 9 M&L for 100mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate incl demolition all as specified and directed 10 M&L for 60 mm thick pre polished rubber moulded coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658- 2006 M-35 Grade with grey cement and no pigment complete all as specified and as directed. 11 M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. 12 M&L for Vitrified Ceramic tiles light shade 7-8 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. over andincluding screed bed 15 mm thick in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to matchwith tileincluding dismantling of existingtiling complete all as specified and directed 13 M&L for Vitrified Ceramic tiles light shade 7-8 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting/ dado etc. over andincluding rendering/screed bed 10 mm thick in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to matchwith tileincluding dismantling of existingtiling complete all as specified and directed 14 Material and labour for point wiring with 1100 Volts, grade 1.5 Sqmm (nominal area), PVC insulated but unsheathed multistranded copper conductor single core FRLSH cable drawn through and including non metallic medium duty rigid PVC surface/ concealed conduit as per existing or as directed at site with medium duty 20mm dia or higher size PVC conduit complete with all accessories such as socket, elbow, junction box, bell mouth, bend, reducer etc including pressed iron/steel suction boxof thickness 1.2 mm for mounting of switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm (nominal area) single core FRLSH, PVC insulated 1100 Volts, grade multi stranded unsheathed FRLSH copper conductor cable green colour as earth wire upto common earth and connected to earth dolly including cutting chases for conduits and sunken boxes including taking down existing unserviceable copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc as existing for the followings: Note : The wiring to be done as per IE rule and as per colour code. 15 (a) One light point,controlled by one way switch. 16 (b) One fan point, controlled by one way switch through regulaor. 17 (c) One bell point, controlled by bell push switch. 18 (d) One three pin 5 Amp socket on same board with other switches. 19 (e) One three pin 5 Amp socket on independent board. 20 (f) Allas per ItemNo 14 mentionedhere-in- before but one three pin 15 Amps switch socket outlet on the independentboardwith 2.5 sq mmPVC insulated FRLSH copper conductor and 2.5 Sqmm FRLSH copper conductor for continuous earthing complete. 21 Material and labour for point wiring with 1100 Volts, grade 1.5 Sqmm (nominal area), PVC insulated but unsheathed multistranded copper conductor single core FRLSH cable drawn through existing concealed conduit any type or size complete including pressed iron/steel suction boxof thickness 1.2 mm for mounting of switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm (nominal area) single core FRLSH, PVC insulated 1100 Volts, grade multi stranded unsheathed FRLSH copper conductor cable green colour as earth wire upto common earth and connected to earth dolly including cutting chases for sunken boxes after taking down existing unserviceable copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc as existing for the followings: Note : The wiring to be done as per IE rule and as per colour code. 22 (a) One light point,controlled by one way switch. 23 (b) One fan point, controlled by one way switch through regulator. 24 (c) One bell point, controlled by bell push switch. 25 (d) One three pin 5 Amp socket on same board with other switches. 26 (e) One three pin 5 Amp socket onindependent board 27 (f) Allas per ItemNo 15 mentionedhere-in- before but one three pin 15 Amps switch socket outlet on the independentboardwith 2.5 sq mm PVC insulated FRLSH copper conductor and 2.5 Sqmm FRLSH copper conductor for continuous earthing complete. 28 Material and labourfor sub main wiring with 2 single core wire for phase and neutral and one run of earth wire PVC insulated unsheathed cable 1100 Volts grade heavy duty FRLSH copper conductor multistranded drawing in and including 20 mm dia or higher medium duty PVC surface/ concealed conduit/ flexible conduit as existing or as directed at site whereever required and conduit accessories and fittings including one single core green colour PVC insulated unsheathed FRLSH cable copper conductor multistranded as earth wire upto common earth and connected to earth dolly complete including cutting chases for conduits etc after taking out old unserviceable submain and making good disturbed surfaces of walls, floors, etc as existing for the followings sizes of wires all as directed. Note : The wiring to be done as per IE rule and as per colour code. 29 (a) 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire. 30 (b) 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire. 31 Material and labourfor sub main wiringwith 2 single core wire for phase and neutral and one run of earth wire PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded drawn in existing concealed conduit any type or size including one single core green colour PVC insulated unsheathed cable FRLSH copper conductor multistranded as earth wire upto common earth and connected to earth dolly complete after taking out old unserviceable submain and making good disturbed surfaces of walls, floors, etc as existing for the followings sizes of wires all as directed. Note : The wiring to be done as per IE rule and as per colour code. 32 (a) 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire. 33 (b) 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire. 34 Supply and fix switch piano flush type single pole one way 230 Volts 6 Amp complete all as specified and directed. 35 Supply and fix socket outlet 3 pin, 230 Volts 5/6 Amps flush type multipurpose 5 pin complete all as specified and directed. 36 Supply and fix switch piano flush type, single pole, one way, 230 Volts 15/16 Amps complete all as specified and directed. 37 Supply and fix socket outlet multipurpose having provision for 3 pin, 230 Volts 15/16 Amp and 3 pin, 5/6 Amp, piano flush type complete all as specified and directed. 38 Supply and fix bell push flush type 5 Amps 230 Volts single pole complete all as specified and directed. 39 Supply and fix calling bell ding dong type AC 230 Volt single pole complete all as specified and directed. 40 Supply and fix lamp holder polycarbonate insulated body, with back plate suitable for batten fitting complete all as specified and directed. 41 Supply and fix stepped type regulator socket type double module 5 step for ceiling fan 1200/1400 mm size230 volts, 6 Amps 120 watts complete all as specified and directed. 42 Supply and fix Ceiling rose, three terminal ISI marked surface bakelite suitable for batten fitting complete all as specified and directed. 43 Supply and fix energy efficient LED tube light fittings 20 Watts, 230 volts with efficiency of not less than 100 lumens per watt, PC extruded body with PC diffuser including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed. 44 Supply and fix energy efficient LED tube light fittings 10 Watts, 230 volts with efficiency of not less than 100 lumens per watt, PC extruded body with PC diffuser including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed. 45 Supply and fix LED luminaire 600 mm x 600 mm, 35/36 watt, (White/ warm white as per user equirement at site) 220 Volts, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. 46 Supply and fix LED Bulk head light fitting 10 Watt capacity die cast alluminum including surface mounted, with decorative oval diffuser comprrising of high brightness LEDs complete all as specified and directed. 47 Supply and fixing LED building security light fitting 35 Watt 230 Volts, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including bracket made out of 32 mm bore medium grade GI pipe made to shape with bolts, nuts & washers of min 1.2 mtr incl grouting of nuts or fasteners clamps and conductor to fitting with 3 core 1.5 sqmm PVC insulated cable complete all as specified incl taking out old u/s fitting complete. 48 Supply and fix distribution board SPN 8 Way double door, for mounting MCBs isolator, ELCBs etc factory made fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar 100 Amps rating of IP 43 protection including taking down existing unserviceable and depositing to MES store yard complete all as directed.Note:- DB and MCCB/MCB shall be of same make. 49 Supply and fix distribution board SPN 12 Way double door, for mounting MCBs isolator, ELCBs etc factory made fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar 100 Amps rating of IP 43 protection including taking down existing unserviceable and depositing to MES store yard complete all as directed.Note:- DB and MCCB/MCB shall be of same make. 50 Supply and fix distribution board Triple pole and neutral double door 415 Volt 4 way DBs IP-43 suitable for 160 Amps rated bus bar incl taking down existing unserviceable and depositing to MES store yard complete all as directed.Note:- DB and MCCB/MCB shall be of same make. 51 Supply and fix distribution board vertical Triple pole and neutral double door 415 Volt 4 way DBs IP-43 IK- 09 Vertical type suitable for 160 Ams rated bus bar & including one MCCB 100 Amp 4 pole as incoming incl taking down existing unserviceable and depositing to MES store yard complete all as directed.Note:- DB and MCCB/MCB shall be of same make. 52 Supply and fix MCB single pole and neutral 240 volt 10 KA 40 Amp C series conforming to ISI marked complete all as directed. 53 Supply and fix MCB single pole and neutral 240 volt 10 KA 32 Amp C series conforming to ISI marked complete all as directed. 54 Supply and fix MCB single pole 240 volt 10 KA 6- 32 Amp C series conforming to ISI marked complete all as directed. 55 Supply and fix MCB TPN 415 volt 10 KA 63 Amp C series conforming to ISI marked complete all as directed. 56 Material and labour in replacement for earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised from 4 mm dia earth lead by means of bolts, nuts, check nuts and wathers of GI or steel all as shown in electrical plate No. 5 of SSR Part-I 1991 connected to earthing test point/transformer/panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber ( 1 : 3 : 6) type C1, RCC pit cover , charcol, salt including provision of earth lead protected by 40mm dia light grade GI pipe and 20mm dia medium grade GI Pipe for watering complete. Note: (i) If the desired earth resistance less than 05 Ohm is not found within permissible limit shall be redone by contractor at no extra cost.(ii) Cost of GI wire 4 mm dia earth lead and 20mm dia light grade GI pipe and 20mm dia medium grade GI Pipe for watering upto 7.5 mtr is included in the rate quoted for this item. 57 Material and labour for laying, jointing and testing in replacement undergroundXLPE insulated & PVC sheathed, armoured heavy duty multistranded electric cable with aluminium conductor, 1100 volts grade in trenches/ ducts/ along poles/ through pipe/ under road/ PCC etc and connecting with new aluminium lugs including taking out existing unserviceable of any size/ type complete for the following cables of cross sectional area all as directed: Notes:(a)Excavation, returning, removal, sand cushioning, cable protection covers, GI protection pipe etc shall be measured and paid separately.(b)Any damage done during cable excavation to the existing UG infra like UG pipelines, UG electric cables, OFC etc shall be repaired by the contractor at their own expenses.(c)Cost of T&P required for handling/ laying of cable is deemed to be included in the rate quoted by the contractor. 58 (a) 10.0 Sqmm, 4 core. 59 (b) 16.0 Sqmm, 4 core. 60 (c) 25.0 Sqmm, 4 core. 61 Excavation in trenches in any type of soil not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth for laying of cable, foundation etcand getting out complete all as directed. 62 Material and labour for sand cushioning & covering of UG cable using crushed metal sand in trenches for cable protection complete all as directed. 63 Material & labour for sub class B bricks well burnt of size 23 x 11.5 x 7.5 cm for protection of UG cable laid dry flat over the cable width wise across the length of the cable and abutting each other with gap less than 10mm between the adjacent bricks in trenches complete all as directed. 64 Returning, filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in soil complete all as directed. 65 Removing of excavated soil to a distance n exc 50 mtr and deposited where directed at a level not exc 1.5 mtr above the starting point complete all as directed. 66 Supply & Laying GI tubing light grade with all fittings and accessories for protection of cables on ploe/ wall or under road crossings including clamps, nuts, bolts etc of size 50 mm complete all as directed.