Tender For road work Gms Sabzi Rajouri- 1 Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) includingdisposal of excavated earth lead upto 50meters and lift upto 1.5 m,as directed by Engineer-in-Charge. All kinds of soil 2 Earth work in excavation by manual means in trenches for foundations, drains,pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspitsand the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil 3 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, lead upto 50Mt & lift upto 1.50M. 4 Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete 5 Dry stone pitching, 225mm thick, including cost of stones and preparation of surface. 6 Nallah stone 7 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete 8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level 9 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 10 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 11 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) 12 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 13 CAST-IN-SITU Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level. 14 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 15 Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 16 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 17 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 18 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 19 Reinforced cement concrete work in arches, archribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with: 20 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 21 Steel Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete 22 Thermo-Mechanically Treated bars of grade Fe-500D or more 23 Centering and shuttering including strutting, propping etc. and removal of form work for :- 24 Foundations, footings, bases of columns etc. for mass concrete 25 Columns, Pillar, Pier, abutments, posts and struts 26 Lintel, beams, plinth beams, girders, bressumers and cantilevers 27 Suspended floors, roofs, landings, balconies and access platforms 28 Edges of slabs and breaks in floors and walls - Under 20 cm wide 29 Stairs (excluding landings) except spiral staircases. 30 Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : 31 Cement mortar 1:6 ( 1 cement : 6 coarse sand) 32 Extra for brick work in super structure above plinth level upto floor V-level. 33 Half brick masonryHalf brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : 34 Cement mortar 1:3 ( 1 cement : 3 coarse sand) 35 Extra for half Brick masonry in superstructure above plinth level upto floor V level 36 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 37 Providing and fixing pressed steel door / WINDOW frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60mm thickness, including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.60mm pressed, mild steel welded or rigidly fixed together by mechanical means, including M.S pressed butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 38 Profile B-Fixing with adjustable lugs with split end tail to each jamb 39 Profile E-Fixing with adjustable lugs with split end tail to each jamb 40 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). 41 Second class deodar wood - 35MM 42 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. 43 Ply wood 5 ply, 9 mm thick- Decorative ply wood both side decorative veneer (type 1) conforming to IS 1328 BWR type 44 Float glass panes- 5.0 mm thick glass pane (weighing not less than 12.50 kg/sqm) 45 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia wire and 1.4 mm wide aperture with matching wood beading 46 Providing and fixing IS : 1341 marked M.S. heavy weight - Butt Hinges with necessary screws etc., complete : 47 125x90x4.00 mm 48 Providing and fixing bright finished brass door latch with necessary screws etc. complete. : 49 300x16x5 mm 50 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. 51 250x10 mm 52 Providing and fixing bright finished brass handles with screws etc. complete : 53 125 mm 54 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete 55 Twin rubber stopper 56 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 57 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 58 Providing and fixing hand rail of approved size by welding etc. to steel Ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 59 M.S. tube 60 VITRIFIED FLOOR TILESProviding and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching Pigments etc. complete. 61 Size of tile 600x600 mm 62 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shades, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints. 63 Size of tile 600x600 mm 64 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 65 Size of tile 600x600 mm 66 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 67 Stone tile work for wall lining upto 10m height with special adhesive like araldite or equivalent over 12mm thick bed of cement mortar 1: 3 (1 cement : 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade. 68 8mm thick (mirror polished and machine cut edges) - Granite stone of any colour and shade 69 Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 70 Granite work 71 Providing and fixing on wall face un-plasticized Rigid PVC rain waterpipes conforming to IS: 13592 Type A including jointing with seal ring confirming to IS:5283 leaving 10 mm gap for thermal expansion. 72 (i) Single socketed pipes - 110 mm diameter 73 Providing and fixing on wall face un-plasticized - PVC moulded fittings / accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 74 Coupler - 110 mm 75 Bend 87.5° - 110 mm bend 76 Shoe (plain) - 110 mm shoe 77 CEMENT PLASTER (IN FINE SAND)12mm Cement plaster of mix: 78 1:6 (1 cement : 6 fine sand) 79 15mm cement plaster on the rough side of single or half brick wall of mix 80 in 1:6 (1 cement : 6 fine sand). 81 6MM CEMENT PLASTER 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) 82 Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: 83 Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.75litre/10sqm of approved brand and manufacture 84 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 85 1 mm thick 86 Distempering with 1st quality acrylic distemper (ready mixed)having VOC content less than 50 gms/litre,two or more coats on new work of approved manufacturer, of required shade and colour complete as per manufacturer’s specifications 87 Finishing walls with 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 13.94.1 New work (Two or more coats applied @ 1.43 litre/10 sqm. Over & including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 88 Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations.a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs)c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofingcompound conforming to IS 2645 and approved by Engineer-in-charge.d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep.e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer in-charge. 89 With average thickness of 120mm and minimum thickness at khurra as 65 mm 90 Carriage of Materials By Mechanical Transport including loading, unloading and stacking 91 Sand for an averagd distance of 150km by MT , 92 Stone Aggregate or an averag distance of 40km by MT , below 40 mm nominal size 93 Bricks for an average distance of 170 km by M T 94 Soling stone for an average distance of 10km by M T 95 Carriage of Materials - By Manual Labour including loading, unloading and stacking for lead less than 0.50 km 96 Sand for an averag distance of 300mtrbyH.L 97 Sand, stone aggregate for an averag distance of 300mtrbyH.L 98 Bricks for an averag distance of 300mtrbyH.L 99 Soling stone for an averag distance of 300mtrbyH.L 100 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 101 Group A 102 Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required. 103 Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required. 104 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 105 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 106 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 107 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 108 Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required 109 Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required. 110 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 111 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 112 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessedconduit as required. 113 25 mm 114 40 mm 115 Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But withoutMCB/RCCB/Isolator) 116 6 way (4 + 18), Double door 117 Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted includingearthing etc. as required. 118 12 way , Double door 119 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, Ccurve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. 120 Single Pole 121 Single pole and neutral 122 Supplying and fixing 40 A to 63 Arating, 240/415 V, 10 kA, Ccurve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. 123 Single pole and neutral 124 Supplying and fixing following rating, Four pole, 415 V, 10 Ka M.C.Bin the existing MCB DB complete with connections, testing andcommissioning etc. as required. 125 40 A F.P MCB 10 Ka C Curve 126 32 A F.P MCB 10 Ka C Curve 127 Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required. 128 Supplying,installation,Testing&CommissioningofStreetlightLEDfixture powdercoatedpressurediecastaluminumbody withdriver as per the requirement with Driver efficiency >85%,Input voltage: 140-270 VoltAC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5KVL,N,EasperIEC61000-4-5,Driverefficiency >85%,THD< 10%asperIEC61000-3-2,P. F.≥0.95,IP66,IK-10,CRI>80,undervoltageandovervoltageprotection,EMIEMCAsper CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry)ofminimum 50000BurningHourswith70%ofinitial Lumenmaintained tilllife ends as per LM80 extrapolation IES TM-21-11 report,CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K(AsperANSIBin),SDCM(Standard Deviation Color Matching) <5,Maximumpowerconsumption should not more than the specified rating and Fixture shall be of relevant BIS standardcompleteinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥105 <120lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C). 129 120 watt 130 Supply installation testing and commissioning ofCeiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt,Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. 131 1200 MM 132 Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body materialand construction as per IS : 10322 withdriver (Replaceable)as per the requirement with Driver efficiency >85% ,Operating voltage AC140-270 Volt,freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20,CRI>80, Flicker free, (flickershould be below 5 %), life time (LED,Driver & electrical circuitary), ofminimum 50000BurningHourswith,70%ofinitial Lumenmaintained tilllife ends, CCT3000°K/ 4000°K / 5700°K/6000°K/6500°K(AsperANSIBin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BISstandard andtrade markcertificate(T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. completeinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy≥105 <120lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures asper BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C). 133 Powdercoated die cast/ Extrudedaluminium Body (Thickness≥ 1.20 mm) 134 40 watt 135 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thickincluding accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required. 136 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required. 137 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metrebelow ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nutbolt & spring washer spaced at 50mm) 138 Supplying,Installation,Testing and Commissioning of Cubical Type Indoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)(BuildingDistributionPanel ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagrambefore start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall beCPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD 139 INCOMER 140 Adj. TMR Based MCCB 100Amps FP Icu=Ics=100%Breaking Capacity 36 KA with Extendable ROH (01 Nos) 141 Adj. TMR Based MCCB 63 Amps FP Icu=Ics=100%Breaking Capacity 36 KA with Extendable ROH 142 150 A,415 Volts 50Hz Aluminium Busbarset of 4 strips 143 100 A,415 Volts 50Hz Aluminium Busbar set of 4 strips 144 Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. 145 OUTGOINGS 146 Manual Changeover 63 A F.P 415 Volts with AC-23 Duty (Front operated) 147 Adj. TMR Based MCCB 63 Amps FP Icu=Ics=100%Breaking Capacity 36 KA with Extendable ROH 148 F.P 32A 10 Ka C Curve MCB 149 D.P 25A 10 Ka C Curve MCB 150 F.P 40A 10 Ka C Curve MCB 151 Load Bearing Members to be made out of 2.0 mm CRCA Sheet. 152 Partitions to be made out of 1.6 mm CRCA Sheet 153 Gland Plates to be 3.0 mm Thick. 154 Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required. 155 63 mm dia (OD-63 mm & ID-51 mm nominal) 156 Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required. 157 3.5 C X 25 Sq.mm A2XFY 158 Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet) 159 3½ X 25 sq. mm (28mm)