| 1 | Supplying of vermin and dust proof totally enclosed phosphatised powder coated cubical indoor type, floor mounting compartmentalize panel board of size 1.2 m x (1.3 + 0.3) m x 0.35 m made of 16 SWG (1.66 mm) thick C.R sheet and 40 mm x 40 mm x 5 mm size angle having four legs at the bottom, complete neatly wiring done as specified and directed by the deptt. confirming to IP 65 protection comprising of following electrical items:i) 125 Amps FP (25kA) MCCB as incoming – 01 Pc.ii) Single phase LCD Meter (5-30 A) - 12 Pcsiii) 40 Amps SPN (10 kA) MCB - 12 Pcsiv) 30 mm x 10 mm 4 Strips Aluminium Bus-Barv) Digital 3 Phase Voltmeter Accuracy class 0.5 - 1 Pc.vi) Digital 3 Phase Ammeter Accuracy class 0.5 - 1 Pc.vii) Pilot Lamp with integral ckt LED 110-230 V (Red, Yellow & Blue) - 3 Pcs.viii) 6 A SP MCB (10 kA) for indicator wiring - 3 Pcsix) 125/5 Ratio CT Coil - 3 Pc. |
| 2 | Supplying of vermin and dust proof totally enclosed phosphatised powder coated cubical indoor type, floor mounting compartmentalize panel board of size 1.6 m x (1.1 + 0.3) m x 0.35 M made of 16 SWG (1.66 mm) thick C.R sheet and 40 mm x 40 mm x 5 mm size angle having four legs at the bottom, complete neatly wiring done as specified and directed by the deptt. confirming to IP 65 protection comprising of following electrical items:i) 125 Amps FP (25kA) MCCB as incoming - 01 Pc.ii) Three Phase Four Wire Meter (10-40 A) - 06 Pcs.iii) 40 Amps TPN (10 kA) MCB - 06 Pcs.iv) 30 mm x 10 mm 4 Strips Aluminium Bus-Barv) Digital 3 Phase Voltmeter Accuracy class 0.5 - 1 Pc.vi) Digital 3 Phase Ammeter Accuracy class 0.5 - 1 Pc.vii) Pilot Lamp with integral ckt LED 110-230 V (Red, Yellow & Blue) - 3 Pcs.viii) 6 A SP MCB (10 kA) for indicator wiring - 3 Pcs.ix) 125/5 Ratio CT Coil - 3 Pcs. |
| 3 | Supplying of vermin and dust proof totally enclosed phosphatised powder coated cubical indoor type, floor mounting compartmentalize panel board of size 1.5 m x (1.2 + 0.3) m x 0.35 M made of 16 SWG (1.66 mm) thick C.R sheet and 40 mm x 40 mm x 5 mm size angle having four legs at the bottom, complete neatly wiring done as specified and directed by the deptt. confirming to IP 65 protection comprising of following electrical items:i) 125 Amps FP MCCB (25 kA) as Incoming - 01 Pc.ii) Single phase LCD Meter (5-30 A) - 09 Pcsiii) 40 Amps SPN (10 kA) MCB - 09 Pcs.iv) 30 mm x 10 mm 4 Strips Aluminium Bus-Bar.v) Digital 3 Phase Voltmeter Accuracy class 0.5 - 1 Pc.vi) Digital 3 Phase Ammeter Accuracy class 0.5 - 1 Pc.vii) Pilot Lamp with integral ckt LED 110-230 V (Red, Yellow & Blue) - 3 Pcsviii) 6 A SP MCB (10 kA) for indicator wiring - 3 Pcs.ix) 125/5 Ratio CT Coil - 3 Pcs. |
| 4 | Supplying of vermin and dust proof totally enclosed phosphatised powder coated cubical indoor type, floor mounting compartmentalize panel board of size 1.6 m x (1.1 + 0.3) m x 0.35 m made of 16 SWG (1.66 mm) thick C.R sheet and 40 mm x 40 mm x 5 mm size angle having four legs at the bottom, complete neatly wiring doneas specified and directed by the deptt confirming to IP 65 protection comprising of following electrical items:i) 125 Amps FP MCCB (25 kA) as incoming-01 Pc.ii) Single phase LCD Meter (5-30 A) - 09 Pcs.iii) 40 Amps SPN (10 kA) MCB - 09 Pcs.iv) 30 mm x 10 mm 4 Strips Aluminium Bus-Barv) Digital 3 Phase Voltmeter Accuracy class 0.5 - 1 Pc.vi) Digital 3 Phase Ammeter Accuracy class 0.5 - 1 Pc.vii) Pilot Lamp with integral ckt LED 110-230 V (Red, Yellow & Blue) - 3 Pcs.viii) 6 A SP MCB (10 kA) for indicator wiring - 3 Pcs. |
| 5 | Supplying of vermin and dust proof totally enclosed phosphatised powder coated cubical indoor type, floor mounting compartmentalize panel board of size 1.0 m x (1.2 + 0.3) m x 0.35 m made of 16 SWG (1.66 mm) thick C.R sheet and 40 mm x 40 mm x 5 mm size angle having four legs at the bottom, complete neatly wiring done as specified and directed by the deptt. confirming to IP 65 protection comprising of following electrical items:i) 125 Amps FP (25kA) MCCB as incoming - 01 Pc.ii) Three Phase Four Wire Meter (10-40 A) - 04 Pcs.iii) 40 Amps TPN (10 kA) MCB-04 Pcs.iv) 30 mm x 10 mm 4 Strips Aluminium Bus-Barv)Digital 3 Phase Voltmeter Accuracy class 0.5 - 1 Pc.vi) Digital 3 Phase Ammeter Accuracy class 0.5 - 1 Pc.vii)Pilot Lamp with integral ckt LED 110-230 V (Red, Yellow & Blue) - 3 Pcs.viii) 6 A SP MCB (10 kA) for indicator wiring - 3 Pcs.ix)125/5 Ratio CT Coil - 3 Pcs. |
| 6 | Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc80 mm dia nominal bore |
| 7 | Laying of one number XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following sizes direct in ground including excavation sand cushioning protection covering and filling the trench etc as required, (i) Size exceeding 95 Sqmm but not exceeding 185 Sqmm |
| 8 | Laying of one number XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following sizes direct in ground including excavation sand cushioning protection covering and filling the trench etc as required, (i) Size exceeding 185 Sqmm but not exceeding 400 Sqmm |
| 9 | Supplying and making end termination with brass comperession gland and alluminium lugs for following size of PVC insulated and PVC sheathed/XLPE alluminium conductor cable of 1.1 KV gland as required, (i) 3.50 Core x 150 Sqmm |
| 10 | Supplying and making end termination with brass comperession gland and alluminium lugs for following size of PVC insulated and PVC sheathed/XLPE alluminium conductor cable of 1.1 KV gland as required, (i) 3.50 Core x 240 Sqmm |
| 11 | Supplying and fixing cable route marker with 10cm x 10 cm x 5mm thick GI Plate with inscription there onb, bolted/welded to 35mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required |
| 12 | Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand,including finishing smooth etc. complete as per direction of Engineer in- charge. |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 14 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 15 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth(I) level :(I)1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 16 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand |
| 17 | 15 mm cement plaster on the rough side of single or half brick wall of mix1:6 (1 cement: 6 fine sand) |
| 18 | 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) |
| 19 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of requiredshade(Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 20 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 21 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 22 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 23 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 24 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade |
| 25 | Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and testedBeyond 12 m and up to 18 m depth |