Tender For Rectification Work Of Fire Fighting At Jnis; 1 Fire system 2 supply,installation,testing and commissioning of double door fire hose box fabricated from 18SWG MS sheet,duly powder coated in red colour,complete with locking arrangement and key,suitable for housing two lengthsof fire hose and branch pipe,wall mounted type,as per relevant IS standards,including all accessories,materials,labour,tools and incidentials required to complete the work in all respects as per the direction of the engineer in charge 3 SITC of hydrant valve coupler ring washer made of high quality neoprene/nitrile rubber suitable for 63mm (2 1/2) instaneous fire hydrant valve coupling.The washer shall have an inner diameter of approximately 63/65mm,puter diameter of 72mm,and thickness not less than4 mm,designed to provide a watertight seal under pressure conditions.The washer must be compatible with standard fire hydrant couplings as per IS:903 and IS:5290 or equivalent 4 Supplying installing testing and commissioning of pressure guage 100mm dia glycerin filled dial type range 0 to 21 kg per sq cm (0 to 300psi) bottom connection brass internals with necessary GI nipple socket isolation cock and accessories ,complete as require for fire fighting system 5 OD333981/2025-2026Supplying, installing, testing and commissioning of Hose Reel Drum conforming toIS:884, 20mm dia. thermoplastic hose (reinforced), 30 m length, fitted with heavyduty shut-off nozzle, complete with wall mounting bracket, MS drum (swing type),inlet connection 25 mm dia. ball valve, and all accessories, as required 6 OD333982/2025-2026Supplying, installing, testing and commissioning of 25 mm dia Air Release Valve(ARV),screwed type, PN 16 pressure rating, body made of cast iron / ductile iron / gunmetal,ISImarked, complete with isolation valve, nipple, socket and all accessories as required,suitable for fire fighting pipeline 7 Supply and fixing Fire Hose BOX Key,suitable for double door hose box,fabricated in MS/stainless steel,powder coated/chrome finish,complete as required. 8 OD333983/2025-2026Supply and delivery of Fire Hose RRL Coupling (Male & Female), completewith gasket, of approved material and size as per IS:903Net Total 1.000no 9 OD333985/2025-2026Supplying and providing Stainless Steel Branch Pipe with 63 mm male instantaneouscoupling (IS:903), complete with suitable SS nozzle (20 mm / 25 mm dia),confirming to relevant IS standards, heavy duty type, polished finish, suitable for usewith fire hydrant hose 10 Suppling and fixing PVC protective cap suitable for 63mm hydrant valve outlet (IS:5290 typeA/B),heavy duty red colour ,with chain arrangement to prevent loss,complete as required 11 Supply, delivery, and installation of Single Head Hydrant Valve, flanged type withlugs, madeof Gunmetal IS:318 LTB2, 63 mm female instantaneous outlet as per IS:5290, PN 16,completewith blank cap and chain, tested to relevant IS standards. 12 OD334021/2025-2026Supply and replacement of handwheel suitable for hydrant valve, heavy duty castiron/CI, red painted, of standard make and size as per IS:5290. 13 Supply and replacement of glass for hydrant valve key box,clear/transparent type,rectangular cut,thickness 3-4mm,suitable for standard fire hydrant key box. 14 Supply and replacement of front glass for fire hose box made of clear float glass 4 to 5 mm thick cut to required sizesuitable for standard single /double door hose box 15 Supplying and fixing 63 m dia,15m long RRL hose pipe with 63 mm dia male andfemale couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A)as required: Stainless steel (Grade 304) 16 OD334022/2025-2026Supply and fixing of LED Exit Sign, single/double sided, with legend EXIT, made ofCRCA sheet/aluminium housing, with acrylic front cover, letters in green/red as perIS/ISO standards. 17 OD334026/2025-2026Supply and installation of ABC type 5kg fire extinguisher 18 OD334024/2025-2026Supply, installation, testing and commissioning of 12V, 150AH SMF battery forstand by generator 19 Fire Alarm system 20 FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying,installation, testing & commissioning fire alarm sounder with facility to makeannouncement, mounted in M.S. box (16 SWG) with hinged cover plate &suitable for operation with amplifier i/c line matching transformer etc. complete asrequired. 21 Supply and replacement of breakable /frangible MCP (Manual Call Point)glass,suitable for standard type manual call point unit in the alarm system,including fixing in position complete as required 22 FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying,installation, testing & commissioning of heat detector operating at 54ºC /57ºC with rate of rise cum fixed temperature (dual thermistor) type withmounting base complete with all connection etc. as required. 23 Supply and installation of sealed maintenace-free (SMF) lead acid battery,12 Volt,7 Ampere-hour capacity ,suitable for use in Fire Alarm System control panel,including necessary connections and testing ,complete as required 24 FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying,installation, testing & commissioning talk back slave station in surface/ recesssuitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc.complete as required. 25 FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying,installation, testing & commissioning of manual call boxes of MS Constructionin surface/recess with stainless steel chain & hammer assembly Complete withglass and push button etc. as required. 26 Supplying, installation, testing & commissioning sector panel suitable forfollowing zones, complete with visual indications for short circuit fault, open circuitfault, fire condition and all other standard facilities as per IS:2189 with mimicdiagram for all area/zone covered, complete with all connections, interconnections asrequired.12 Zone 27 PUBLIC ADDRESS SYSTEMSupplying, installation, testing & commissioningof digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply completeas required.