Tender For Proposed Rejuvenation And Development Of Tourist Facilities At Assi Ghat At Varanasi(U.P.) (Notice No. -64/Uppcl/Gm-1/2025-26/E-Tenderdated: 22.08.2025) - Proposed Rejuvenation and Development of Tourist Facilities at Assi Ghat at Varanasi(U.P.) 2 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed as directed by Engineer-in- charge.All kinds of soil 3 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming & watering, lead up to 50 m and lift upto 1.5 m. 4 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 5 Carriage of Earth by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 6 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. - Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 7 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 8 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 9 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 10 Demolishing stone pitching in floors, slopes, etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 11 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 12 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 13 Carriage of Rubbish by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 14 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. 15 Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete. 16 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. 17 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 18 Same as item 16. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 19 Carriage of Soling Stone by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 20 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 21 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 22 1:3:6 (1 Cement : 3 coarse sand (zone-Ill) derived from natural sources :6 graded stone aggregate 40 mm nominal size derived from natural sources) 23 Carriage of Stone Aggregate 40mm nominal size and above by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 24 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 25 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.Concrete of M25 grade with minimum cement content of 330 kg /cum.All works upto plinth level 26 All works above plinth level upto floor V level. Concrete of M25 grade with minimum cement content of 330 kg /cum 27 Carriage of Sand, Stone Aggregate below 40mm by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 28 Add for using extra cement in the items of design mix over and above the specified cement content therein. 29 Carriage of Cement by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 30 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating, brooming with wire brush etc. All complete including shutting, channel, etc. as per specifications and directions of Engineer-in-charge. 31 Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) :400 mm dia piles 32 Same as item 30 but 500 mm dia piles 33 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/ Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing.Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.Single pile upto 50 tonne Safe capacity. Initial test (Test Load 2.5 times the Safe capacity) 34 Same as item 32 but Routine test (Test Load 1.5 times the Safe capacity) 35 Same as item 32 but Single pile above 50 tonne and upto 100 tonne Safe capacity Initial test (Test Load 2.5 times the Safe capacity) 36 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for all lift and level.Thermo-Mechanically Treated bars (Fe500d) 37 Carriage of Steel by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 38 Centering and shuttering including strutting propping etc, and removal of form for : Foundations, footings, bases of columns etc., for mass concrete 39 Centering and shuttering including strutting propping etc, and removal of form for :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 40 Centering and shuttering including strutting propping etc, and removal of form for :Suspended floors, roofs, landings, balconies and access platform 41 Centering and shuttering including strutting propping etc, and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers 42 Centering and shuttering including strutting propping etc, and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts 43 Carriage of Timber by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 44 Brick work with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 45 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 (1 cement : 6 coarse sand) 46 Carriage of Bricks by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 47 12 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand) 48 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 49 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) 50 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) 51 Finishing with Acrylic smooth exterior paint of required shade: New work (two or more coat applied @ 1.67 ltr/10 sqm. Over and including priming coat of exterior primer applied @ 0.90 Lt./ 10 sqm.) 52 Finishing with Acrylic smooth exterior paint with Silicone additives of required shade:New work (two or more coat applied @ 1.43 ltr/10 sqm. Over and including priming coat of exterior primer applied @ 0.90 Lt./ 10 sqm.) 53 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. 54 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. 55 Providing & mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck, using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of selfhealing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 56 Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/ honey-comb area of concrete/ masonry by suitable gun/ pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) Stirrer mixed SBR Polymer (of approved make) modified Cement slurry made with Shrinkage Compensating Cement in concrete/ RCC work. 57 Same as item 55 but Epoxy injection grout in concrete/RCC work of approved make 58 50 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. (At riser and skirting also). Red sand stone 59 50 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. (At riser and skirting also).White sand stone 60 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone / granite. 61 Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. 62 Stone work in plain ashlar in super structure upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with cement mortar 1:2 (1white cement :2 stone dust) with an admixture of pigment matching the stone shade : Both face dressed. Red sand stone 63 Stone work in plain ashlar in super structure upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with cement mortar 1:2 (1white cement :2 stone dust) with an admixture of pigment matching the stone shade : Both face dressed. White sand stone 64 Kota stone (25mm thick) slab flooring over 20 mm (avg) thick base laid over & jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing & polishing complete with base of cement mortar 1:4 (1 cement :4 coarse sand): 65 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 66 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.- Polished Granite stone slab of approved colour 67 Providing and laying gang saw cut, mirror polished pre-moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. completeas per direction of Engineer-in-Charge. Granite 30mm thick of any colour and shade 68 Extra for sand blasted finish over granite stone as per design requirement. 69 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - exposed face fine dressed with roughbacking - 30mm thick 70 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :White sand stone - exposed face fine dressed with roughbacking - 30mm thick 71 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 72 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. 73 Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge.(The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). Red sand stone - 30mm thick gang saw cut stone 74 Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge.(The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). White sand stone - 30mm thick gang saw cut stone 75 Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/ RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to theEngineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/ planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). 76 Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge. 77 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 78 Providing and Fixing of Stone bollard 150mm dia and 900mm high including foundation of the bollard. All complete as per approved drawing, sample and directed byEngineer-in-charge. 79 Providing and fixing stainless steel (Grade 304) railing, gate, Changeroom, Bin, etc. (Matt / Glossy finish) made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval ofEngineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 80 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. All complete as per approved drawing, sample and directed by Engineer-in-charge. Red sand stone 81 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. All complete as per approved drawing, sample and directed by Engineer-in-charge.White sand stone 82 Designing, providing and Fixing of Sitting pavillion of 3x3 mt. (c/c) with 4 nos. Stone columns of avg. 350x350mm and Stone tie beam 250x450mm with 300mm projection from bottom of beam having clear height of3.0 mtr. above finish level including design depicted with the help of carving, embossing, engraving and inserting along with base of the column as per approved design based on Client/ Architects input. (Foundation works is in civil scope). All complete as per approved drawing, sample and directed by Engineer-in-charge. (refer reference drg.) 83 Designing, providing and installing of PVC/ PVDF composition of coated composite material as per conceptual drawing. The flexible composite material (fabric) have characteristics of High tenacity polyster: Tio2 reinforced PVC coating and PVDF coated both sides, etc. All complete including Fabric wire rope 16mm, Anchor bolts to tie with RCC/ Stone Column, etc. as per approved drawing, sample and directed byEngineer-in-charge. (refer reference drg.) (Plan area shall be measured.) 84 Designing, providing and installation of Post top light in Stone column of size 300mm dia (avg.) x 3.0 mtr. high (height incl. square base) inclusive of carving, embossing, engraving, insertion, etc. with LED light fixture. (Foundation works is in civil scope). All complete as approved and directed by Architect and Engineer-in-charge. 85 Providing and applying silicone based water repellent coating confirming to BS: 6477-1984 in 2 coats with a consumption of 6 sq.mtr/ litre per coat over the exposed surface including cleaning the surface making it free from dirt, oil grease, wax and all other contamination using mechanical tool, wire brush, compressed air followed by water washing and as per the manufacturer specification and direction of Engineer-in-charge. 86 Research, designing, providing and fixing of stainless steel(Grade 316) (Matt / Glossy finish) 50x50mm hollow circular pipe in ring shape of 4 different sizes of diameter 1650mm, 2350mm, 2850mm & 3150mm of 3mm thickness respectively placed in ascending order from top creating a umbrella structure and fixed on a column (Stone/ Metal) as per approved design based on Client and Architects input of height 2800mm (having a SS capital on top) and a SS pipe arch of 90mm dia. & 3.6mm thick and of radius 1625mm. IP65 rated LED strip light placed on 15mm SS flat welded to the inner side of the SS ring and laser cut SS Diya of size 1050x900mm of desired thickness between the portals and work includes welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete of required sizeetc. (Foundation is in civil scoppe). All complete as per approved drawing, sample and as directed by Engineer-in-charge. (refer reference drg.) 87 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 88 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 89 Carriage of Stone Blocks, GI, CI, Stainless steel pipes below 100mm dia and other heavy material by Manual Labour including loading, unloading and stacking for lead up to 500 mtr. (net quantities after deduction of prescribed percentage for voids as per specification) 90 Supply and Installation of Light Fixtures. 91 Supply and installation of 4000mm Florian pole made of circular mild steel pipe of two section (grade YST 210) Bottom section 139.7mm Dia x 3.6mm thick with 1200mm Height & Top section 76.1mm Dia x 2.6mm thick with 2695mm Height. On the top of the pole a decorative flower arrangment as shown in the image. Decorative base made of Gravity Die-cast aluminium (436mm Dia x 481mm Height). Decorative Die- cast Aluminium cone (180mm Dia x 175mm Height) covered on the both section joint area. Pole section welded by certified welders using high end MIG welding processes. PDC aluminium service door 348mm height x 110mm width shall be provided with the company logo embossed on the bottom of the door and safety rope. The control gear tray is prewired with 2.5 Sq.mm cable, 6A SP MCB and 32A Ramanuj stud type 4 way terminal block for loop-in / loop-out arrangement, 5A 2 Way terminal connector and provision for earthing. Any other internal cables and connections shall not be covered in the scope of supply. Mild steel mounting plate 200mm Square x 12mm thick Steel of grade E250 to IS 2062 : 2011 with 4 elongated holes 38 x 19 to suit M16 x 300mm bolts of grade 4.6 at CC 140. The base plate have a cable entry hole of 70mm dia at the center. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. All dimension are within +/- 5% tolerance. After fabrication, entire pole is shot blasted (Inhouse). The pole is coated with zinc rich primer & pure polyester powder coating or epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint (coating thickness 60-80 microns). The Pole shall be provided with Graphite grey / Anthracite grey / Black as standard colour options. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-charge. Make K-lite/ Unilamp/ Havells and Phillips or Equivalent. 92 Supply and installation of 45-50W Post top with LED 3000K, 4000K, 5700K 240Vac CRI >80 MacAdam step 3 Dimension not less than Ø400 x 807 mm, Light Distribution360° Electronic driver ON/OFF, IP rating IP65, Spun aluminium top cover Ø400 mm of 1.6mm thickness, die cast aluminium decorative knob on top, Mild steel (Sand Blasting with zinc primer supporting arm integrated with die-cast aluminium base suitable for mounting Ø76mm OD pipe. SS fasteners. Pure polyester powder coated process : Acid treatment & pure polyester powder coating. Clear acrylic diffuser with controlled downward light emission. Lamp fixed position. Lumen efficacy should be minimum 120lm/W. This luminaire should contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire >56,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >88%, power factor >0.96, THD <10%, Surge protection 6KV. All complete including consumables required for installation. Sample should be submitted for approval fromEngineer-in-charge. Make: K-Lite/ Unilamp/ Philips and Havells or Equivalent. 93 Supply and installation of Surface mounted LED linear with system power [20W ± 5%], should be available in 3000K/4000K/6000K color temperature, maximum dimesnion 1200 x 43 x 52mm should be made up of High-Grade Aluminium with Die-cast Endcaps, Diffuser/ Lens Material : Polycarbonate, Secondary : Hexa-Cell (Matt Black), UGR<16, dali dimmable driver operational voltage range of 90-265V, power factor > 0.9, THD < 10%, Inbuilt surge protection of 3 KV, Luminaire has Ingress protection ofIP20. The luminaire should have minimum lumen outputof 100lm/W, CRI of >80. The LEDs used have a life of 50,000 burning hrs Lumen maintenance as per L70B10 with SDCM<=3 binning Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs - LEDs of CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/LUMILED / NICHIA/ CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-charge. Make: K-Lite/ Unilamp/ Havells and Phillips or Equivalent. 94 Supply and installation of Static White 3000K surface mounted compact spot light designed to provide directional light. Beam angle 15° / 25° / 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. Clear toughened glass of 4mm thickness. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression.Power consumption should be between 10W to 12W at steady state full intensity luminaire should have minimum luminous flux of 1054 Lm. Color rendering index CRI ≥ 80 and power factor of complete luminaire ≥ 0.90, at white colour.Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP65/66. Mechanical resistance IK06. Pure polyester powder coated graphite grey / anthracite grey / jet black. Available colour temperature 3000K / 4000K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire 113 x 84 x 117mmmm. Adequate heat sink with proper thermal management shall be provided. Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%. THD should be less than 10%. Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs -LEDs of CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/ LUMILED /NICHIA/CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval fromEngineer-in-charge. Make: K-Lite/ Unilamp/ Havells and Phillips or Equivalent. 95 Supply and installation of Decorative Pole Height 6M with Cast Iron Base made of circular mild steel pipe of two section (ISI Marked, grade YST 210), Bottom section & Top section 114.3mm Dia x 3mm thick respectively. Decorative Golden ring made of Die cast Aluminium at jointing section of two pipes (230mm Dia x 250mm Height) . Decorative base made of Gravity Die-cast aluminium or CI base approximately A/f 420mm and 966mm Height. Wind speed considered in design 50 m/sec in compliance with IS 875 Part 3 : 1987. Wind pressure calculation as per IS 875 (part-3) & structural calculation report certified by any Government Institution as per EN40 should be submitted to verify the pole design. Pole section welded by certified welders using high end MIG welding processes. PDC aluminium service door 348mm height x 110mm width shall be provided with the company logo embossed on the bottom of the door and safety rope with IP protection rating. The Double arm pelican jesy bracket is a split constructed type, Bracket stem made of MS Pipe 60.3mm Dia x 2.6mm thick, emerging from a Gravity Diecast Aluminium embellishments.The Bracket is crowned at top with CNC cut Chakra of Appropriate size. The artistically curved single arm made of MS pipe 38.1mm Dia x 2mm thick, with gravity diecast aluminium leaves Shaped embellishment, is firmly held to the stem by way of MS clamps and the arm bears cast iron knobs at one end and other ends facilitates the fitment of luminaire at 800mm on either side from the vertical axis of the bracket stem, it should be highlighted with 6W surface mounted compact spot light designed to provide directional light. Beam angle 15° / 25° / 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. Clear toughened glass of 4mm thickness. Surface mounting spike made of polypropylene black. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP65. Mechanical resistance IK06. Pure polyester powder coated graphite grey/ anthracite grey/ jet black. Available colour temperature 3000K/ 4000K/ 5700K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. 96 Supply and installation of pendent type 50W LED, pendant mounted compact street light. Asymmetrical light distribution. Decorative luminaire made of pressure die cast aluminium body of high corrosion resistance and non corrosive stainless steel fasteners. Clear toughened glass diffuser of 5mm thickness.Stainless steel 304 suitable for mounting to internally threaded pipe of designation M30. Protection class IP65. Mechanical resistance IK10. Pure polyester powder coated RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 7016 Anthracite grey. Available colour temperature 3000K / 4000K / 5700K, Colour rendering index (CRI)>70. SDCM-3 MacAdam. LED module with expected service life of at least 1,00,000 operating hours with luminous efficacy of 140 lm/W at 4000K and with T-IV optics. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD <10%, Surge protection 6KV. Make of LEDsof CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/ LUMILED / NICHIA/ CITIZEN. Luminaire dimension Should not be more than : 490mm diameter x 160mm height. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities CE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Architect and Engineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent.. The control gear tray is prewired with 2.5 Sq.mm cable,6A MCB and 32A terminal connectors for loop-in / loop-out arrangement. Mild steel mounting plate of round shape with 280x 12mm thick Steel of grade E250 to IS 2062 : 2011 with 4 elongated holes 38X19 to suit M16 x 500mm bolts of grade 4.6 at CC230. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. All dimension are within +/- 10% tolerance. Shot blasting process for surface preparation of pole before painting / powder coating is required. The manufacturer should have in-house shot blasting machine and salt spray testing equipment. Test report should be submitted. The pole is coated with zinc rich primer & pure polyester powder coating or epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint of desired RAL (coating thickness 60-80 microns).All complete including consumables required for installation. Sample should be submitted for approval fromEngineer-in-charge. Make:Havells and Phillips or Equivalent. 97 Supply and installation of 12W square decorative leser cut designer bollard LED 3000K, 4000K, 6500K 230-240Vac CRI >80 MacAdam step-3 Height910mm Light DistributionSymmetrical, Electronic driver ON/ OFF LUMINAIRE TYPE Bollard. IP rating IP66, Extruded square aluminium tube (grade 6063 with test certificate) Sq. 150 x 3mm thickness. Should have Bespoke laser cutting design options. SS fasteners.Should have Die-cast aluminium mounting plate Sq.150 x 4mm thick with 3 elongated holes 20 x 12 to suit M10 bolts at PCD 90 with pure polyester powder coating. This mounting plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foudation. Hot dip galvanised foundation bolt. Mechanical resistance IK06. Optical grade clear toughened glass diffuser of 4mm thickness with controlled downward light emission. Lamp fixed position. This luminaire should contains built-in IP 65 LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, power factor >0.9, THD <10%, Surge protection 2.5KV. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities. All complete including consumables required for installation. Sample should be submitted for approval fromEngineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 98 Supply and installation of White 3000K 1W In-ground with in built honey comb louvre symmetrical luminaire made up of die-casting withØ34 x 62 mm,the Ø34front ring should be made up of stainless steel 316 grade front ringwith silicone black gasket and toughened clear glass diffuser. The luminous flux of the luminaire is upto 169.06 lm for 3000K BEAM - 40. The ingress protection is IP67 and impact resistance of IK06. The luminaire is integrated with high power CITIZEN COB with CRI≥80, SDCM≤3, L70/ B10 @ 60000 Hrs. The integral constant current driver comes with the power factor greater than or equal to 0.9, total harmonic distortion less than 15% with operating efficiency greater than 80% and a surge protection of 2KV. The driver input voltage 240Vac at 50-60Hz, operating voltage of 100-277Vac and operating temperature of -20˚ ~ +40˚C. Adequate heat sink with proper thermal management shall be provided. Operating Humidity : 10%-90%. THD should be less than 10%. The fixtures proposed must have passed LM 79 & LM-80, Reports from NABL laboratory will be submitted post the issuance of LOA to the successful bidder and before the supply of material. Make of LEDs -LEDs of CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/ LUMILED /NICHIA/CITIZEN. CE & BIS Certified. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 99 Supply and installation of Input power : 12WCeiling-mounted compact down light emission designed to use monochromatic Warm white (3000K) & Neutral white (4000K). Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Extruded aluminium section with inner grooves to fix the top andbottom frame (grade 6063) ?100 x 3mm thickness, die-cast aluminium glass fixing frame ?100mm with clear toughened glass diffuser of 4mm thickness with ceramic black coated on outercorner siliconed to frame & die-cast aluminium cover for surface mounting on ceiling ?106mm (ADC12). Die-cast aluminium heat sink for excellent thermal management. Single cable entrance via black M10 cable gland (SS). All external screws are made of stainless steel. Clear silicone gasket. Protection class IP65. Mechanical resistance IK07. Acid treatment & pure polyester powder coated graphite grey / anthracite grey / jet black. The luminaires built-in LED module are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21). Operating ambient temperature range is from -15°C to +50°C. Beam angle 15° / 25° / 40°, Colour rendering index (CRI)>80. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD <10%, Surge protection 2.5KV. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities . Luminaire square 106mm x height 150mm. CE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 100 Supply and installation of6W, Wall-mounted compact down light emission designed to use monochromatic Warm white (3000K) & Neutral white (4000K). Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Extruded aluminium section with inner grooves to fix the top and bottom frame (grade 6063) Ø100 x 3mm thickness, die-cast aluminium glass fixing frame Ø100mm with clear toughened glass diffuser of 4mm thickness with ceramic black coated on outercorner siliconed to frame & die-cast aluminium top closing frame Ø100mm (ADC12). Die-cast aluminium heat sink for excellent thermal management. Single cable entrance via black PG7 cable gland, Die cast aluminium base for surface mounting on wall (ADC12). All external screws are made of stainless steel. Clear silicone gasket. Protection class IP65. Mechanical resistance IK07. Acid treatment & pure polyester powder coated graphite grey / anthracite grey / jet black. The luminaires built-in LED module are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21). Operating ambient temperature range is from -15°C to +50°C. Beam angle 15° / 25° / 40°, colour rendering index (CRI)>80. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.90, THD <10%, Surge protection 2.5KV. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities Luminaire dimension : 150mm length x 100mm width x 150mm height. CE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval fromEngineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 101 Supply and Installation of Light Fixtures. 102 Supply and installation of 7m multi head pole with provision of 8X45W Led, With diffrent beam angle as per requirement, bottom should be in two parts dia 139.7mm and top dia 88.9mm, Wind speed considered in design 50 m/sec in compliance with IS 875 Part 3 : 1987. Pole section welded by certified welders using high end MIG welding processes. Two PDC aluminium service door 348mm height x 80mm width shall be provided with the company logo embossed on the bottom of the door and safety rope with IP protection rating. The control gear tray is prewired with 2.5 Sq.mm cable, 6A MCB and 32A terminal connectors for loop-in / loop-out arrangement & Driver box. The Mild steel mounting plate 250mm Sq x 12mm thick Steel of grade E250 to IS 2062 : 2011 with 4 elongated holes 38 x 19 to suit M16 x 500mm bolts of grade 4.6. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. All dimension and weight are within +/- 5% tolerance. The pole is coated with pure polyester powder coating or epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint (coating thickness 60-80 microns). The Pole shall be provided with Graphite grey/ Anthracite grey/ Black as standard colour options Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs - LEDs of CREE/ LUMINOUS/ OSRAM / SEOUL / SAMSUNG/ LUMILED/ NICHIA/CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of material CE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 103 Supply and installation of 70W LED Spot beam light, Integral control gear, should be maximumu Dimension : Ø210 x 216 x 268 Mounting: Surface ProductFinish: Grey IP: 65/66, should be made from Pressure Die-Cast Aluminium and toughened glass, Luminaire should be capable8° / 12° / 24° / 40° / 60 ° / 40°x11°. Should have different options in beam angles, Luminaire should be complete with driver and capable of operating at line voltage of 100-270 Vac, 50Hz with PF of >0.9, Fixture should be capable to operate at ambient temperature range of -20-to +40°C and should be IP65 and IK07, LED life of L70 B10 60,000 H. Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs -LEDs of CREE/ LUMINOUS/ OSRAM/ SEOUL/ SAMSUNG/ LUMILED/ NICHIA/ CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Engineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 104 Supply and installation of IP rating IP67, Linear grazer Input power : 10W, 2700K, 3000K, 4000K24Vdc CRI >80 MacAdam step 3 Dimension not more than 1010 x 17 x 9mm Beam angle: 120° Electronic driver ON/OFF (External driver), High-Grade aluminum & Endcaps, Polyurethane Encapsulation diffuser. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire >60,000 hours at 40°C. Operating ambient temperature range is from -25°C to +55°C. Must be operated with 24V DC External Driver efficiency >85%, power factor >0.90, Surge protection 3KV. Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs -LEDs of CREE/ LUMINOUS/ OSRAM/ SEOUL/ SAMSUNG/ LUMILED/ NICHIA/ CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval fromEngineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 105 Supply and installation of Static White 3000K surface mounted compact spot light designed to provide directional light. Beam angle 15°/ 25°/ 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. Clear toughened glass of 4mm thickness. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Power consumption should be between 10W to 12W at steady state full intensity luminaire should have minimum luminous flux of 1054 Lm. Color rendering index CRI ≥ 80 and power factor of complete luminaire ≥ 0.90, at white colour. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP-66. Mechanical resistance IK06. marine grade coating graphite grey / anthracite grey / jet black. Available colour temperature 3000K/ 4000K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire 113 x 84 x 117mm. Adequate heat sink with proper thermal management shall be provided. Operating Temperature: -10°C to +50 C, Operating Humidity : 10%-90%. THD should be less than 10%. Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs -LEDs of CREE/ LUMINOUS/ OSRAM/ SEOUL/ SAMSUNG/ LUMILED/ NICHIA/ CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval fromEngineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 106 Supply and instllation of 9W/m encapsulated silicon flex, should be at least IP 67 3000K 24Vdc CRI >80 MacAdam step 3 Beam angle: 120°, Should be equipped with dot less homogenous lighting effect Electronic driver ON/OFF (External driver) Material Characteristics: Copper coated strip, Silicone moulded diffuser, End cap,Clip. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 50,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >70%, Power factor >0.80, Surge protection 3KV. Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs -LEDs of CREE/ LUMINOUS/ OSRAM/ SEOUL/ SAMSUNG/ LUMILED/ NICHIA/CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Architect and Engineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 107 Supply and installation of Customised narrow spot light of 6-8W LED, should be available in LED colors 3000K, 4000K, 6000K 24Vdc CRI >80 MacAdam step 5, should have maximum Dimension of 65 x 55 x 99mm and with beam angle of 2°, IP rating 66, Made from Die Cast Aluminium Alloy. Toughened clear glass diffuser. SS fasteners. Aluminium mounting bracket for surface mounting on ground. Toughened Clear glass diffuser and optical to reduce glare controlled. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Must be operated with 24V DC External Driver efficiency >85%, power factor >0.90, Surge protection 3KV. Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs -LEDs of CREE/ LUMINOUS/ OSRAM/ SEOUL/ SAMSUNG/ LUMILED/ NICHIA/ CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval fromEngineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 108 Supply and installation of IP rating IP67 linear wall washer. Input power: 20W, 2700K, 3000K, 4000K 24Vdc CRI >80 MacAdam step 3 Dimension not more than 1005x 25x 32mm Beam angle : 30/60° Electronic driver ON/OFF (External driver), High-grade aluminum & Endcaps, Polyurethane Encapsulation diffuser. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire >60,000 hours at 40°C. Operating ambient temperature range is from -25°C to +55°C. Driver efficiency >85%, Surge protection 3KV. and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval fromEngineer-in-charge. Make: K-Lite/ Unilamp / Havells and Phillips or Equivalent. 109 Bought Out Items 110 Designing, providing, fabrication and placing Sand Stone 3-seater Bench placed on ground including base/ foundation as per approval. The stone should be carved using CNC machine. Before execution, the agency shall submit shop drawings with all necessary details. Mock-up at site shall be put as per approved shop drawing. Final execution shall be done as per tested and approved mock-up. All complete as per approved drawing, sample and directed by Architect and Engineer-in-charge. (refer reference drg.) 111 Designing, providing, fabrication and placing dustbin of SS 304 having an outer frame in SS finish fixed to the ground and drum made of 4mm thick sheet fixed on pivot over the outer frame. Drum finish is matt from outside and polished from inside. High proformance rust proof treated outer wall with invisible seamless welded. Sand stone of 100 mm thick fixed at bottom of the frame. Placed over the hard firm base. The dustbins with the complete framework and with all necessary hardware, brackets, clits, base, etc. all complete shall be fixed over the pedestal. Before execution, the agency shall submit shop drawings with all necessary details. Mock-up at site shall be put as per approved shop drawing. Final execution shall be done as per tested and approved mock-up. All complete as per approved drawing, sample and directed by Architect and Engineer-in-charge. (refer reference drg.) 112 Supply installation, testing and commissioning of Water ATM/ Purified Water Vending Machine Power Supply- AC 220V 50Hz/ AC 110 V 60 Hz- Production capacity 3000 GPD- Water Tank capcity- 200 L- UV power- 20 W- Ozone capacity- 1000 mg, Filling Flow Rate- 8 L/min-Selling Method- IC card coins paper note, Size of filling bottle- 200 ml, 500 ml,1L, 2L,20Ltr ( at a time in one tap), Filteration step- 9 steps, Size- L80 cmxW68 cmxH200 cm, Packing-Carton for FCL or Poly wood case for LCL, 19 inch for adertisement LCD panel, Reverse Osmosis (RO), Ultra Violet (UV) Technology, Ozonation Water chiller LED Technology. All complete including over head water tank, base of Kiosk and shed with foundation as per approval of Architect and Engineer-in-charge. 113 SUB HEAD -I ELECTRICAL PANELS:FEEDER PILLAR FEEDER PILLAR-01 (IP-67) INCOMER: MCCB 415V, 50Hz, 100A, 4P, 25kA for 1 sec rated thermal magnetic based MCCB with inbuilt LSIG protection- 1 Nos. Indication lamps LED type phase indication lamps suitable for 230V,50Hz AC (red, yellow, blue) - 1 Set.LED type Indication lamps for breaker, suitable for 230V,50Hz AC supply (on, off, trip) - 1 set With Photo Sensor/LUX Sensor + Timer With Astronomical Switch. BUS-BAR- Busbar (1 Set - 4P + E)Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 150 A, 25 kA for 1 sec of required length and cross sectional area. OUTGOINGS: MCB18Nos. 415V, 50Hz, 25A, DP, 10 kA MCB.24Nos. 415V, 50Hz, 32A, DP, 10 kA MCB. Feeder Pillar as described above 114 SUB HEAD- II : EARTHING -Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 115 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 116 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 117 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. 118 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe From earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. 119 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 120 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 121 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 122 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 123 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 124 SUB HEAD- III : CABLE & CABLE TERMINATION- Supplying following 1.1kV grade, heavy duty XLPE insulated, FRLS type armoured /Unarmured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete as required. 3.5C x 50 sqmm A2XFY 125 3C x 6 sqmm 2X 126 3C x 4 sqmm 2X 127 1C x 4 sqmm 2XY 128 Supplying and making end termination with brass compression gland and cuppor lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 50 sq. mm (35 mm) 129 Supplying and making end termination with aluminium lugs for following size of aluminium conductor cable of 1.1 kV grade as required. 3C X 6sq. Mm 130 3C X 4sq. mm 131 SUB HEAD-IV:CIVIL WORK - Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) 132 90 mm dia (OD-90 mm & ID-76 mm nominal) 133 Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 134 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 80 m :All Kinds of Soil.Pipes, cables etc., exceeding 80mm dia but not exceeding 300mm dia 135 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm diameter 136 200 mm diameter 137 250 mm diameter 138 300 mm diameter 139 Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with RCC Top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix ( 1 cement :4 coarse sand: 8 graded stone aggregate 40 nominal size), inside plastering 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand),finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80 cm and 50 cm deep including perforated C.I. / RCC cover with frame (Heavy duty) 455x610 mm internal dimensions. 140 Inside size 120x90 cm and 90 cm deep including C.I./RCC cover with frame (heavy duty) 560 mm internal diamete 141 Providing & fixing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per I.S:10910 on 12 mm dia steel bar conforming to I.S:1786 having minimum cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 165 mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturers permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15cm cement concrete block 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) complete as per design. 142 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 300 to 350 mm diameter 143 For pipes 250 to 300 mm diameter 144 Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.4 145 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 500x700 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design. Dimensions 500x700 mm & 45 cm deep for pipe line with one or two inlets. With common burnt clay F.P.S. (non modular) bricks of class designation 7.4 146 GST Extra as applicable