Exterior Rustic Paint And Other Misc.Work At State Election Commission Building, Bhopal; 1 15.2.1 Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge Cu M 85 578 49130 2 14.64 Chipping, Removing, Carefully loose plaster and Concrete work by low impact Hammer, Breaker without damaging the structure asInstructed by Engineer-in-Charge. sqm. 152 120 18240 3 15.6.3 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material with in 50 metres leadas per direction of Engineer-inCharge. Cu M 46 487 22402 4 15.11 Dismantling tile/ Kota stone/ Marble / Granite work in floors / walls and roofs laid in cement mortar including stacking material within 50 metres lead.Dementling tiles a 15.11.1 For thickness of tiles 10 mm to 25 mm. Sq M 454.29 17 7723 b 15.11.2 For thickness of tiles above 25 mm and upto 40 mm. Sq M 210.00 26 5460 5 15.3 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of EngineerinCharge. Cu M 90.00 844 75960 6 15.14 Dismantling doors, windows and clerestory indows (steel or wood) shutter including chowkhats, rchitrave, holdfasts etc. complete and stackingwithin 50 metres lead : 15.14.1 Of area 3 sq. metres and below each 30.00 85 2550 7 15.45 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. each 30.00 223 6690 8 1.2 Transportation by manual labour including loading, unloading and stacking for lead up to 50 metre. A 1.2.1 Lime, moorum, building rubbish beyond 5km up to10 km per km Cu M 180 53.43 9617 9 15.25 Removal of old Tarfelt i/c disposal as directed by Engineer in charge. P.SQM 778 8.7 6769 BRICK WORK & PLASTER WORK 10 6.12 Providing half brick masonry with well burnt chimney bricks in bull patent trench kiln manufactured by ghol process crushing strength not less than 40 kg /cm2 and water absorption not more than 15% in superstructure above plinth level and up to floor two level. 6.12.2 Cement mortar 1:4 (1 cement : 4 sand) SQM 56 673 37688 ESTIMATE NAME OF WORK :- The Work Of Exterior Rustic Paint & Other Miscellaneous Work At State Election Commission Building, Bhopal. PAC-84,23,000 Time-06 Month 11 6.17 Extra for providing and placing in position 2 Nos. 8mm dia. M.S. bars at every third course of in half brick masonry. SQM 56 127 7112 12 13.3 20 mm cement plaster of mix : After grouting 13.3.1 1:4 (1 cement : 4 sand) sqm 98.2 245 24059 13 13.4 12 mm cement plaster finished with a floating coat of neat cement of mix : 13.4.1 1:3 (1 cement : 3 sand) sqm 32.2 210 6762 RCC,PCC & CEMENT CONCRETE WORK 15 2.6 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil cum 50.00 147 7350 16 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : 4.1.1 With 20mm nominal size graded stone aggregate. 4.1.1.1 M-20 – Grade concrete cum 12 4933 59196 4.1.1.2 M-15 – Grade concrete cum 11.2 4471 50075 17 2.26 Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding20cm in depth and dressing complete Note: - Maximum thickness of this layer shall be 20 cm. cum 25 672 16800 18 5.9 Centering and shuttering in cluding strutting, propping etc. and removal of form for: 5.9.2 Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. A 5.9.2.2 Above plinth upto 3.6 m height from plinth level sqm 45.20 330 14916 B 5.9.2.3 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of deshuttering and decentering at alllevels, over a height of 3.6 m, for every additional height of 1 metre or part thereof. sqm 20.52 2560 52531 19 5.16 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detalingIS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . (Note:- 1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers. 3.Couplers shall be conforming to IS code on “Reinforcement Couplers for MechanicalSplices of Bars for Concrete Reinforcement - Specification”) Thermo-Mechanically Treated bars.FE 500 D or more conforming to IS 1786 5.16.6 Thermo-Mechanically Treated bars.FE 500 D or more conforming to IS 1786 kg 52 80 4160 20 5.3 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate)in beams, suspended floors, roofs havingslope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstaircases above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement inconcrete grade. cum 7.20 6541 47095 21 2.39 Providing and laying of permanent piping technology antitermite treatment before flooring work by installing LLDP (Low linear density polyethylene) tube of 8 mm O.D. & 6.4 mm I.D.with inbuilt pressure compensation chip at every 30cm interval in the tube, having working pressure of 2 kg/cm2 and release rate of 1.9 ltr/hour fixed by P-clips and nails. The LLDP pipe shall be installed at the entire periphery of the building and atnternal network of building at a depth of 20 to 200 mm under floor at every 2 to 3 mtr. c/c distance (adjusted as per building layout) & Ends of loop pass i through a PVC elbow of minimum 32mm ID at junction box of wall and floor level, entering into a steel reinforced grooved flexible pipe of minimum 22 mm ID leading into Junction box and the loops shall terminate in junction boxes & test every junction during injecting chemicals for termite control treatment. The antitermite chemical Imidacloprid 30.5% SC mix as per IS6313, (part III) shall be injected by the pressure pump diluted with water @ 10.5ml/5 ltr of water at the rate of 2 kg/sq.cm. @ 5Ltr/SMT. The contractor shall submit approved line plan for piping system and junction boxes dully approved by Engineerincharge with bond of 5 year warranty. 2.39.2 Anti-termite chemical injected area sqm 602 53 31906 Water proofing 22 14.87 Providing and inserting 12mm dia galvanised steel injection nipplein honey comb area and along crack line including drilling of holes of required diametre (20mm to 30mm) up to depth from 30mmto 80mm at required spacing and making the hole & crack dust free by blowing compressed air, sealing the distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of EngineerIn-Charge Each 50 136 6800 23 14.83 Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/ pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight ofapproved grout injected.) 14.83.3 Epoxy injection grout in concrete / RCC work of approved make Kg 20.2 658 13292 24 22.14.1 Grading roof for receiving water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) Cu M 8.2 6569 53866 25 22.22 Water proofing treatment over Roof, Wall, Chajjas,, Balcony with fibre glass mesh andSealer coat at leakage/ seepage area consisting of (i) Surface preparation roughening of surface, opening cracks in ‘V’ groove in size of 5mmX10mm (WXD), filling of cracks with putty with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/Nylon brush. Removing all dust particles and washing with adequate water to clean completely. (ii) Providing and applying 1st coat of fibre glass mesh (minimum thicknes 70-80 micron) and two component flexible waterproof and protective modified mortar, dry powder 80% chemical 20% acrylic resin having 30% solid contents) with mix proportion of part 1 and 2 with proper mixing with laying of fiber glass mesh (of weaving size of 10X10 yarn/inch duly coated with alkaline resistant polymer). Allow the coating to air cure for minimum 2 Hrs. After two hours of 1st coat applying 2nd coat (minimum thickness 100 micron) of fibre glass mesh of with mix proporation of part 1 and 2 with proper mixing. Allow the coating to air cure for minimum 2 hrs. Consumption of two component should be acrylic resin @17.90 kg for 10 sqm area or as per manufacture instructions. (After two coats of diamond shield, surface is to be cured properly minimum for 4 hrs. before application of third coat). 22.22 (iii) Providing and applying 1st coat of sealer coat 50-60 micron (single component Hightbuild elastomeric, fixable pure acrylic waterproofing membrane having solid content of 65%) and allow it to air cure for 4Hrs. minimum. After two hours minimum of 1st coat applying 2nd and finals coat 120-140 micron of sealer coat and allow it to air curefor 4 Hrs mimimum. Consumption of Sealer coat should be @ 5.40 kg per 10 sqm area. (iv) The treated area should be cure with water for 48 hrs. by flooding the surface. (v) The final appearance of the coating will be milky white. All above operations to be done in order.(five years guarantee) Sq M 325.2 465 151218 26 22.9 Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth course of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45, 1.20 and 1.45 Kg per square metre of area respectively, second and fourth courses of roofing felt type 3 grade I conforming to IS : 1322 (Hessian based self finished bitumen felt) conforming to IS : 1322 and sixth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic dm per sqm including preparation of surface but excluding grading, complete. (With five years service gurantee). SQM 120.2 597 71759 27 22.7 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, alconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 sand ) admixed with water sqm 120 885 106200 FLOORING & GRANITE 28 11.3 Providing and laying gang saw cut 18 mm thick,mirror polished premoulded (wherever required)and pre polished machine cut granite stonework in flooring of required size shape of approved shade,color and texture in flooring laid over 20 mm thick base of cement mortar 1:4 (1 Cement: 4 sand) including grouting the joints with white cement mixed with matching pigments epoxy touch ups etc. complete as per direction of Engineer-inCharge 11.30.1 Area of slab over 0.50 sqm 11.30.1.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals ofother colors of glitter sqm 103.2 2642 272654 29 11.83 Providing and laying digital print random design(PGVT)/(GVT) vitrified tiles in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality / premium in skirting, riser, dado and wall lining laid our 12mm thick cement mortar 113 including grouting the joints with white cement and matching pigments etc. complete 11.83.1 For skirting, riser, dado and wall lining etc. glossy/ rustic /stain/mattfinished in all colours and shades a 11.83.1.2 Size 600X600 mm thickness 9-10 mm sqm 120.2 1129 135706 b 11.83.1.4 Size 600X1200 mm thickness 11-12mm SQM 130.2 1224 159365 FITTING & SANITARY 30 18.6 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer inCharge. 18.6.2 Concealed work including cutting chases and making good the walls etc. A 18.6.2.1 15 mm nominal outer dia .Pipes. MTR. 75.3 207 15587 B 18.6.2.2 20 mm nominal outer dia .Pipes. MTR. 45 234 10530 c 18.6.2.3 25 mm nominal outer dia .Pipes. MTR. 29 288 8352 31 18.13 Providing and fixing CPVC gate valve with knob of approved quality. A 18.13.1 25 mm nominal bore EACH 6 428 2568 32 17.58 Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. (minimum wall thickness 3.2mm) A 17.58.1 75 mm diameter MTR. 35 136 4760 B 17.58.2 110 mm diameter MTR. 35 238 8330 33 17.59 Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. A 17.59.1 Coupler I 17.59.1.1 75 mm EACH 7 117 819 II 17.59.1.2 110 mm EACH 8 154 1232 C 17.59.3 Single tee with door I 17.59.3.1 75x75x75 mm EACH 7 219 1533 II 17.59.3.2 110x110x110 mm EACH 8 346 2768 E 17.59.5 Bend 87.50 I 17.59.5.1 75 mm bend EACH 7 117 819 II 17.59.5.2 110 mm bend EACH 8 172 1376 33 19.4 Providing and laying below ground unplasticised PVC pipe to with stand working pressure of 4 kg/cm2 soild waste pipes confirming to IS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving 10mm gap for thermal expansion all necessary fittings etc. complete. Excavation to be paid seperataly. 19.4.5 300 mm diameter OD (min. wall thickness 7.7mm) meter 15 1232 18480 34 19.7 Providing and fixing squaremouth S.W. gully trap class SP1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 19.7.2 150 x 100 mm size P type 19.7.25.2 With sewer bricks conforming to IS : 4885 each 3 1707 5121 35 19.23 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 sand)finished with a floating coat of neat cement and making necessary channels for the drain etc. complete 19.23.1 For pipes 250 to 300 mm diameter each 21 292 6132 36 19.9 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design 19.9.2.1 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : 19.9.2.2 With Sewer bricks conforming to IS : 4885 each 5 17402 87010 37 25.1 Providing and fixing white vitreous china Anti germ FluoroPolymer Coated Water closet squatting pan with 100 mm sand cast Iron P and S- trap, and 7.2 liter Low level, dual flush, PP (Poly Propylene) made open slim wall hung cistern capacity 3 liter/6 liter flushing, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required. 25.1.1 White Vitreous china Anti germ Fluoro-Polymer coated Orissa Pattern W. C. Pan of Size 440X575X250mm With integral foot rests. (Premium Range) EACH 3 4726 14178 38 25.3 Providing and fixing white vitreous china European Wall hung Anti germ Fluoro-Polymer Coated water closet of approved shape with soft closing seat cover, and 7.2 litre Low level slim dual flushing, PP (Poly Propylene) made 80 mm thick concealed flushing cistern, flushing capacity 3 litre/6 litre, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required 25.3.1 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet Size 380X520X375 mm with solid poly propelyne made soft closing seat cover (Premium Range) EACH 2 26412 52824 39 25.12 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling) with sensotronic concealed type flushing valve battery & electricaloprated type (9V transformer) for urinal complete set with installation box with control cock complete including painting of fittings and brackets, cutting and making good the wall and floors wherever required . 25.12.1 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm with sensotronic concealed type flushing valve battery & electrical oprated type (9V transformer) for urinal complete set with installation box with control cock. (Premium Range) each 2 23927 47854 40 25.8 Providing and fixing white vitreous china type Anti germ fluoropolymer coated counter top wash basin with 15 mm C. P. wall mounted pressmatic Pillar cock auto closing system with square wall flange and spout complete (decol technology), 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required all fittings and fixtures etc. complete 25.8.1 Providing and fixing white vitreous china type Anti germ fluoropolymer coated counter top wash basin Size 570x415x200mm with 15 mm C. P. wall mounted pressmatic Pillar cock auto closing system with square wall flance & spout complete (decol technology). (Premium Range) EACH 2 14543 29086 41 25.19 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn)Bib cock. (Premium Range) EACH 6 2071 12426 42 25.2 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating. 10 micron and chrome plating 0.3 micron, quarter turn) Angular stop cock. (Premium Range) EACH 5 1573 7865 43 25.36 Providing and fixing in position best Indian (bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) 2- way Bib Cock .(Premium Range) EACH 5 2687 13435 44 25.37 Providing and fixing in position best Indian Health Faucet with 8mm dia 1.2 meter long Flexible Tube and wall bracket with N. R. V. (non-return wall).(Premium Range Sanitary Ware) EACH 5 1818 9090 45 17.61 Providing and fixing UPVC trap ofself cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet EACH 7 517 3619 46 17.78 Providing and fixing C.P. brass grating of approved quality and make conforming to IS: specification. 17.78.1 100 mm dia. EACH 11 74 814 47 17.67 Providing and fixing bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. SQM 5.2 2440 12688 48 18.28 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank LTR. 1000 7 7000 49 25.52 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Single Towel Ring Square. (Premium Range) EACH 5 2167 10835 50 17.77 Providing and fixing C.P. brass soap container 109 mm wide, 125 high and 112 mm distance from wall ofstandard shape with bracket of the same material with all fittings etc. of approved quality and conforming toIS: specification. EACH 3 1175 3525 51 25.57 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Toilet Roll Holder. (Premium Range) EACH 3 1354 4062 Aluminum windows 52 21.18 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-Charge (Door handle, lock and stopper etc.to be paid separately) sqm 11.55 4958 57265 53 21.19 Providing and fixing 50 micron thick reflective one way type heat /light control film to window/door glazing with complete accessories as per direction of Engineer-incharge of approved brand and make. sqm 11.55 448 5174 54 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.1 For fixed portion. 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 303.2 416 126131 55 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) : 21.3.2 With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg/sqm ) sqm 149.5 948 141726 56 10.26 Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S. Flat 15x3mm and nuts and bolts complete. 10.26.2 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides sqm 65.5 1334 87377 PANNELING 57 9.15 Providing and fixing plain lining with necessary screws/nuts and bolts/ nails including a coat of approved primer on one face and fixed on wooden /steel frame work complete as per direction of Engineer-in charge. (Frame work shall be paid for separately) 9.150.1 12 mm thick commercial ply conforming to IS: 1328 BWR type. Sqm 10 1210 12100 9.150.2 18 mm thick commercial ply conforming to IS: 1328 BWR type. Sqm 12 1320 15840 58 9.134 Providing and Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality. 9.134.2 1.0 mm thick. sqm 22.2 691 15340 CEILING 59 12.58.2 12.5 mm thick tapered edge gypsum board 12.58.2.3 12.5mm thick moisture resistant gypsum plaster boards Moistbloc as per BS EN 520 confirming to water absorption class H1 with total water absorption < 5%, Green Pro certified by CII SQM 55 920 50600 60 12.59 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre- painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge 12.59.1 GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. SQM 45.2 1431 64681 TEXTURED EXTERIOR PAINT 61 13.51 Providing and applying flakes textured homogeneous wall finishing system consisting of a two component system of dry flakes (9.5kgs per/pack) made of a special grade of heat treated China clay with rigid homopolymer coated with fade resistant pigments and a 100% acrylic polymer Bonding agent (5kgs/pack) applied thickness of the coating being between 0.8-1.2mm, to be applied in single coat, on a cured, smooth level plaster surface without keying, as per the shades/ combinations approved, as per manufacturers directions for usage, to be applied by approved applicator of manufacturer, as per direction/ supervision of the engineers-in-charge inclusive of one coat of primer on the base at all heights etc all complete. sqm 5229.8 650 3399370 INTERIOR PUTTY & PAINT 62 14.27 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete SQM 3140.8 5 15704 63 13.67 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. 13.67.3 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. SQM 3140.8 24 75379 64 13.41 Providing and applying white cement based putty of average thickness 1 mm, of approved brand over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete. Note : Putty shall be applied only on the internal walls, for application on the exterior walls prior permission of Chief Engineer will be required. SQM 1520 74 112480 65 13.46 Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work SQM 3181.6 64 203622 13.64 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. sqm 125.26 53 6639 S.SLETTER & SIGNAGE 66 27.8 Providing and fixing stainless steel English (Capital) and Hindi letters in standard pattern bellow type made with 1.20 mm thick stainless steel (ASI Grade- 304 ) Depth of letter shall not be less than 30mm and rate includes elding/soldering of joints polishing, buffing and fixing on the wall, plate and beam surface at any height with necessary nut and bolts/fastener wherever is required complete as per direction of Engineer-inCharge. per letter per cm height 1080 75 81000 STEEL & FABRICATION WORK 67 9.43 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete 9.43.1 Fixed to steel windows by welding. kg 352.2 119 41912 68 10.14 Steel work in built up M.S. tubular section (round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.14.1 Hot finished welded type tubes kg 355.2 117 41558 69 12.85 Design built, supply and erection of Tensile (fabric) structure system including designing and fabrication in M.S. steel tubular structure as per Indian standard section as per approved design and shape including base plate, dash fastener,clits etc. Cutting, patterning, plotting and wielding of fabric with the help of tensile structure software. Fabric should be wielded by high frequency PVC wielding inproper line with PVC cader to be fixed on end of the fabric and to be stretched & fixed on M.S. design structure with the help of. M.S. Flat bar with self-taping screw. M.S. structure to be painted with one coat of epoxy primer with MRF PU paint of approved colour in desired shape. With 1050 GSM tensile fabric 12.85.1 With precontraint tensile membrane 1050 GSM (20 years Warranty) sqm 25.6 9347 239283 70 5.36 Providing and sealing the retaining wall expansion Joints with anodized aluminum extruded section of 135 mm × 3.1 mm confirm to alloy of 6063 T5/T6including fixing of an imported EPDM moisture Barrier conform to (American Society for Testing and Materials) 2240 & ASTM - G53 & 84 fixing with Epoxy adhesive confirm to ASTM C-881 complete in all respect as per manufacturer Drawing and specifications. With 5 year guarantee. metre 12.24 3234 39584 71 12.15 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. SQM 18.12 652 11814 72 5.23 Providing and fixing sheet covering over expansion joints with iron screws as per design 5.23.2 Stainless steel Grade 304 plate-1.0 mm thick 5.23.2.1 150 mm wide. RM 164.52 367 60379 73 10.22 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.22.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. kg 81.25 105 8531 PAVER BLOCK 74 11.72 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks,lawns, drive ways or light traffic parking etc. of required colour strength, thickness pattern, surface texture (smooth/rough) and size/shape, conforming to 15658- 2006 made by table vibratory method using PU mould, laid in required colour and pattern over 50mm thick compacted bed of sand, compacting andproper embedding/ laying of inter locking paver blocks into the bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand including locking with M15 cement concrete in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturers specifications and direction of Engineer-in- Charge. 11.72.1 80 mm thick C.C. paver block of M-35 grade sqm 1950.00 805 1569750