| 1 | Removingdoorsandwindowswithframesandstackingthematerialsasdirectedwithall leads, lifts etc. complete. |
| 2 | RemovingW.C.pansincludingdisconnectingthesanitaryandwatersupplyconnections, removing and breaking flooring and bed con-crete around pan removingthe same carefully and stackingtheserviceablematerialsasadn wheredirected includingthrowingthe unserviceablemateriaslsoutsideetc.carefullyandthrowingouttherefusaloutsideetc. complete. |
| 3 | Removingtheexistingcementplasterofanythicknesswithoutcausingdustnuisanceand stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete. |
| 4 | Removing cement tiles, or marble or polishedshahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete |
| 5 | Removing urinal pans or wash hand basins with frame including disconnecting the sanitary andwatersupplyconnections,removingthesamecarefullyandstackingtheserviceable materialsasandwheredirectedincludingthrowingtheunserviceablematerialsoutsideetc complete |
| 6 | Replacement of damaged Aldrop 300 mm Chromium plated of approved quality and make to doorshutterincludingremovingexistingthesameinoriginalpositionmakingproper adjustment for smoothoperation etc. complete as per sample approved by Engineer in-charge. |
| 7 | Providing andfixing 450mm x550mm size superiortype Belgium mirrorwith16mmdia. nickel plated towel rod etc. complete. |
| 8 | Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. |
| 9 | Providing and fixing Bib cock with wall flange (Angular Shape) in wall surface including all labour and material cost of Jaguar Brand ets.complete.As directed by Engineer Incharge |
| 10 | Providing andfixing 10cm C.I.NahaniTrapincludingC.I.gratingbendandpiece ofC.I. pipe upto the outside face of the wall complete. |
| 11 | Providing andfixing onwalls/ceiling/floor 20mm dia.CPVC pipe withnecessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 12 | Providing , laying and fixing ,jointingEco- drain 110 mm SN 8 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete. |
| 13 | Providing and constructing Brick Masonry inspection trap Chamber 90cm x 45cm including 1:4:8C.Cfoundation,1:2:4C.C.channels/halfroundglazedstonewarepipechannel,salt glazedstone-wareinterceptingtrapwithroddingpipesetin1:4:8cementconcreteblock, brickmasonryplasteringinsideandOutside,fixedincementconcretewithR.C.C.Cover medium duty 140 Kilogram. etc complete |
| 14 | Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Medium duty (140 Kilogram) |
| 15 | Providing and fixingTable top white wash basin of size 120x635x405mm rubber plugs and brass chain, withpillar cock, C.P.Angular stop cock long thread, continentalincluding S.S. bottle trap of approved make havingnecessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. |
| 16 | Providing andfixing white europeantype wall-hung pan, of size 350mm x355mm x570 mmconcealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe uptotheoutsidefaceofwall,100mmdiaC.I.plugbendinletpipeallfittings,cutting& making good walls, floors etc. complete. |
| 17 | Providing and fixing divertor with overhead shower,shower arm,spout,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware or equivalentmake including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge.) |
| 18 | Providing internal cement plaster 20mm. thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. |
| 19 | Manualy clearing the chockes from under ground drainage line including Inspection chambers with the help of required tools for propre functioning line chamber to chamber etc. complete. |
| 20 | Cleaning elevated water storage Reservoir within a given period, by using bleaching powder at the rate of 14 gm/sq.m .washing thrice potassium permanganate at the rate of 2.50 gm/sq.m. finally, cleaning washing by using nylon brush, coir string and duster, bailing out water etc. complete. i)Tank capacity up to 2,000 litre. |
| 21 | Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium platedfixturesandfastenings,withbrassmortiselock,chromiumplatedhandlesonboth sides, and finishing with French Polish etc. complete. |
| 22 | Providingandapplyingmelaminepolishofrequiredfinishtothewoodworkbyspray machineincludingknottingandpreparingtheevensurfacebyscraping,applyingFrench polish , scaffolding if required etc. complete.Note:The work to be executed on prior approval of Superintending Engineer will be necessary. |
| 23 | Providing andfixing in position(as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Runningmetre.Theshuttershouldbeofbearingbottom40x18x1.25mmat weight 0.417Kilogram/One Running Metre.Inter locking section 40x 18x 1.10mm atweight 0.469Kilogram/Runningmetre.andhandleandtopsection40x18x1.25mm atweight 0.417Kilogram/Runningmetre.Asperdetaileddrawingsandasdirectedby Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mmthickplainglassandaluminiummosquitonetshutterwithstainlesssteeljailwithall required screws and nuts etc, complete. With colour Anodising with box |
| 24 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of varioussizeswithpowdercoatingasperdetaileddrawingandspecificationsincluding aluminiumframes80x38mmx1.22mmboxtype,5mmthicksheetglasslouvers,of approved quality etc. complete. |
| 25 | Providing and fixing fly proof mesh shutter toventilator / window using CCTW members of size 45 x22 mm for frame work and35 x 22 mm for middle support andfixing fly proof mesh on it and coveringTW battens of size 20 x 10 mm including priming and two coats of oil painting to the new wood and steel work and all labour charges including all fixture and fastenings etc. complete |
| 26 | Providing antitermite treatment around the periphery of the existing building as per I.S. 6313 (Part-III) by excavating trenches of 20cm width and exposing the sides of columns and plinth beams upto a depth of 300mm and injecting one percent of chlorodane emulsion concentrate at the rate of 2.25 litres per One Running Metre and refilling the trenches etc. complete covering 2 years guarantee on bond paper. |
| 27 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Rubyred / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. |
| 28 | Providing and laying vitrified rustic matt stone finish tileshaving size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approvedmake,shadeandpatternforflooringinrequiredpositionlaid onabedof1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. |
| 29 | Providing and laying vitrified rustic matt stone finish tileshaving size 590 mm to 605 mm x 590 mm to 605 mm to 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approvedmake,shadeandpatternfordadoandskirtinginrequiredpositionfixedin1:4 cement mortar including neat cement float, filling joints, curing and cleaning. etc. complete. |
| 30 | Providing and laying ceramic tileshaving size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. |
| 31 | Providing and laying ceramic tiles having size 30 cm. x 60 cm. confirming to corresponding I.S.for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. |
| 32 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-10oftrap/granite/ quartzite/gneissmetalforfoundationandbeddingincludingbailingoutwater,Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredandcuringcomplete,withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade) |
| 33 | Providing, laying and fixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles forsteps and dado of approved colour and design 22 +/ -2 mm thick bayercolourpigmentedasperIS1237-1980reaffirmedin2006,havingwerttransvrse strenghth of 3.5 / mm 2, water absorption less than 10 % abrasion / wear resistance less than 2 mm ,skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing,polished and cleaning etc. complete. For steps, and dado |
| 34 | ProvidingandfixingP.V.C.Rainwaterpipesof160mmouterdiameterandhavingwall thicknessof2.2to2.7mmconfirmingtoI.S.13592-1992includingproperrainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket withsolventcementandproperlyrestingtheshoeofpipesonC.C.ormasonryblocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. |
| 35 | Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate) |
| 36 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, teesetc.asperdetaileddesignanddrawingsorasdirectedincludingcutting,fabricating, hoisting,erecting,fixinginpositionmakingriveted/bolted/weldedconnectionswithout connecting plates, braces etc. andincluding one coat of anticorrosive paint andover ittwo coats of oil painting of approved quality and shade etc. complete. |
| 37 | Providing and fixing superior quality decorative type wall paper etc.complete. |
| 38 | Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. |
| 39 | Providing andapplying one coatofsealcementprimerofapprovedmanufacture andshed includingscaffoldingpreparingthesurfacebycleaningdirtandotherforeignmatters, scrapping if necessary including scaffolding etc. complete. |
| 40 | Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in single coat including scaffolding, preparing the surface. (excluding the primer coat)etc. complete. |
| 41 | Providing and applying One coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat,scaffolding if necessary , and watering the surface for two days etc complete. |
| 42 | Providing and applying two coats of flat oil paint of approved colour to the old structural steel workandironworkpreviouslypaintedinbuildingincludingscaffolding,ifnecessary, cleaning and preparing the surface (excluding primer coat)etc. complete. |
| 43 | Transportation of material obtained from debris of various sorts excavated stuff including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed.( Beyond 10 Km. ) |
| 44 | Providing royalty charges against royalty paid by the contractor to the Revenue department for supply of different construction material for which royalty is necessary. Natural Sand |
| 45 | Testing Charges for Conducting BASIC TEST OF CEMENT.Standard ConsistancyFineness, Specific Gravity,Setting Time ( Initial & Final ), CompressiveStrength, Soundness etc. complete. |
| 46 | Testing Charges for Conducting BASIC TEST OF FINE AGGREGATES. Fineness Modulus ( Sieve Analysis ),Silt & Clay Content |
| 47 | Testing Charges for Conducting BASIC TEST Of CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) |