| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable, foundation, laying of pipe line and getting out in soft/loose soil all as specified and directed . |
| 2 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. |
| 3 | Removing surplus excavated material to a distance not exceeding 50 meter and deposting where diserted at a level not exc. 1.50mabove the starting point complete all as specified and directed. |
| 4 | M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 200 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grease etc complete all as specified and directed.Note :- (i)DI fitting/special will be measured and paid separately.(ii) Excavation & earthwork shall be measured & paid seperately |
| 5 | M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 150 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grease etc complete all as specified and directed.Note :- (i)DI fitting/special will be measured and paid separately.(ii) Excavation & earthwork shall be measured & paid seperately |
| 6 | M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 100 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grease etc complete all as specified and directed.Note :- (i)DI fitting/special will be measured and paid separately.(ii) Excavation & earthwork shall be measured & paid seperately |
| 7 | Note :-(a) In case of laying of CI/GI/DI pipe line is to be executed in civil area, it will be the responsibility of the contractor to obtain necessary permission for cutting of road & berm from BWSSB. |
| 8 | (b) For this purpose amount to be paid online to BWSSB, same is deemed to be included in unit quoted rate. |
| 9 | (c) The T&P like JCB, Drill Machine, Moveable Generator etc required for cutting of road shall be arranged by the contractor & no extra cost shall be paid for the same. |
| 10 | (d) After execution of work, the contractor will make good disturbed portion of road with bitumen or PCC complete as directed by Engineer-in-Charge. |
| 11 | M & L for cutting up to 2 mtr depth of the existing Municipal corporation Bitumen layer roads for laying of pipe line 100 /150 mm dia and re-fiiling after completion of pipe laying with relaying of Bitumen layer as per municipal / BBMP norms including getting approval from municipal / BBMP authorites complete all as specified and directed . |
| 12 | M & L in repairs for Joint with rubber or fibre board gasket of pipe dia 100 mm bore all as required at site complete all as specified and directed. |
| 13 | M & L in repairs Rubber gasket joint for DI pipe 100 mm dia all as required at site complete all as specified and directed. |
| 14 | M & L for Cutting cast iron pipes and reducing to required length in position for insertion of new tees, branches, etc. of 100 mm bore complete all as specified and directed. |
| 15 | M & L for Cutting cast iron pipes and reducing to required length in position for insertion of new tees, branches, etc. of 300 mm bore complete all as specified and directed. |
| 16 | S & F in repairs MS Bends, Tapers, Tee pieces (single & double branch) any type and angle/radius and straight connecting pieces but all ends flanged upto 150 mm dia |
| 17 | S & F in repairs Connecting MS pieces one end flanged and other socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth of size 200 to 300 mm dia complete all as specified and directed. |
| 18 | S & F in repairs MS Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290. Gde-E-165 complete all as specified and directed. |
| 19 | M & L for providing cement concrete in foundations, filling and mass concrete of B1grade with using 20 mm aggregate (1:2:4)complete for anchoring of pipe line all as specified and directed. |
| 20 | S & F in replacement DI mechanical collar 100 mm bore complete all as specified and directed |
| 21 | S & F in replacement DI mechanical Tee equal 100 mm bore complete all as specified and directed |
| 22 | S & F in replacement DI mechanical tail piece 100 mm bore complete all as specified and directed |
| 23 | S & F in replacement DI mechanical collar with one side Flange and one side socket type of 100 mm bore complete all as specified and directed |
| 24 | S & F in replacement DI mechanical long bend 90 Degree of 100 mm bore complete all as specified and directed |
| 25 | Supply and fixing in replacement Sluice valve of size 200 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all as specified and directed. |
| 26 | Material & Labour as in repair for Construction ofValve pit chamber having inner dimensions 1200 x 1200 x 1000 mm with foundation PCC 1:4:8 type D2 using 40mm graded stone aggregate, brick work with sub class \"B\" old size bricks/ built in Cement mortar 1:6, PCC 1:2:4 type B1 using 20mm stone aggregate for Coping, 15 mm thick renderingin CM 1:4 inluding MS cover with locking arrangement all as specified and as directed.Note :- Chamber Covers shall be measured and paid separately under relevant item of this schedule. |
| 27 | Supply and fix in repairs Valve, reflux, with by-pass Arrangement, 300 mm (10”) dia incl necessary cutting the existing pipe line and alteration as required complete all specified and directed. |
| 28 | Supply and fix in repairs Foot Valve conforming to IS 4038, 200 mm (8”) dia (ISI marked), suitable for 200 mm dia pipe line complete all specified and directed. |
| 29 | Supply and fixing in replacement Sluice valve of size 150 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all as specified and directed. |
| 30 | Supply and fixing in replacement Sluice valve of size 100 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all as specified and directed. |
| 31 | Material & Labour as in repair for Construction ofValve pit chamber having inner dimensions 900 mm x 900 mm x 900 mm with foundation PCC 1:4:8 type D2 using 40mm graded stone aggregate, brick work with sub class \"B\" old size bricks, built in Cement mortar 1:6, PCC 1:2:4 type B1 using 20mm stone aggregate for Coping, 15 mm thick renderingin CM 1:4 inluding MS cover with locking arrangement all as specified and as directed.Note :- Chamber Covers shall be measured and paid separately under relevant item of this schedule. |
| 32 | Supply and fix in replacement Cast Iron Air Valves with two air Outlets, 100 mmbore and fixing up in cast iron water supply mains complete all as specified and directed. |
| 33 | Supply and fix in repairs Valve, reflux, with by-pass Arrangement, 100 mm (4”) dia (ISI marked), suitable for 100 mm dia pipe line complete all specified and directed. |
| 34 | Supply & Fix as in replacement GI tubing medium grade of size 80 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified and directed.Note:Excavation & earthwork shall be measured & paid seperately |
| 35 | Supply and fix in repairs Valve, reflux, with by-pass Arrangement, 80 mm (3”) dia (ISI marked), suitable for 80 mm dia pipe line complete all specified and directed. |
| 36 | Supply and fix in replacement Foot Valve conforming to IS 4038, 80 mm (3”) dia (ISI marked), suitable for 80 mm dia pipe line complete all specified and directed. |
| 37 | M & L for new masquito proof PVC wire mesh superior quality cut to shape and fixed with air vent of sumps/tanks complete all as specified and directed. |
| 38 | S & F in repairs over head tank water level indicator made up of 2 mm thick MS sheet of width 300 mm and depth 3600 mm duly painted on both side with level marking equally in feet measurement mounted on MS Angle iron support of 50 x 50 x 6 mm thick with necessary float, SWR, Needle with pulley arrangement complete and fixed on the exterior wall of OHT complete all as directed |
| 39 | S & F in repairs under ground sump water level indicator made up of 2 mm thick MS sheet of width 300 mm and depth 3000 mm duly painted on both side with leavel marking equally in feet measurement mounted on MS Angle iron support of 50 x 50 x 6 mm thick with necessary float, SWR, Needle with pulley arrangement complete and fixed on the exterior wall of UG Sump complete all as specified and directed. |
| 40 | Supply, errection, testing and commissioning raising and lowering type not less than 16 Mtr height high mast system shaft in two section suitable for 44m/s wind speed along with head frame, luminaire carriage suitable for upto 08 luminairies in symmetrical arrangement and other accessories manufactured in factory including raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box.HIGH MAST SYSTEM: Height of the mast not less than 16Mtr, Design standard PLG 07 of ILP, Basic Wind speed as per IS:875 Part III Design life - 25 yrs; Material construction as per S355 grade as per BSEN10 025; Base dia - 410mm & Top dia - 150mm; with plate thickness : Bottom - 3mm & Top - 3mm. Cross section of the mast shall be 20 side polygon with BS EN ISO 1461 standard galvanisation. With GI single spike lighting protection finial. The high mast shall have 8 nos of foundatino bolt with a PCD of 490mm of TS600 type with 30mm dia and 850mm length. Base plate with a dia of 570mm and thickness of 25mm LUMINAIRE CARRIAGE: Luminaire carriage shall be made of 50NB ERW class B MS Pipe with diameter of carriage ring at 535mm. Construction shall be with 8 arms which are welded and 2 sections capable of holding 08 luminairies. TRAILING CABLE: 5 core 2.5sq mm copper cable with EPR insulation and PCP sheathed. WINCH/POWER TOOL: Winch with double drum, SWL 750Kg integral motor with 1HP capacity with 6 pole, single speed. STAINLESS STEEL WIRE ROPE: Stainless Steel wire with AISI 304 grade and 7/19 construction with 2/3 wire rope of 6mm dia and a 2x2350Kg breaking load capacity including OEM recommendation electrical panel of both Auto and manual mode complete all as specified and directed. Make: Bajaj Model No: BHMRL16C or equivalent make in CG/Phillips. |
| 41 | Note: The rate quoted shall be inclusive of the following:-(a) Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates & templates- complete set(b) Supply of suitable copper conductor cable, glands, lugs and wiring from panel to light fittings- 01 Job(c) Construction of suitable shallow RCC foundation with M-20 grade concrete for the mast considering the safe soil bearing capacity at site as 10 t/m² at 2 metre depth with all material and labour all as per Manufacturer\"s design of foundation drawing as approved by GE.(d)Erection and commissioning of the high mast with the help of suitable equipment. |
| 42 | (e)Provision of GI pipe earthing for mast with 2.5m long 40mm dia GI Pipe including connection to mast earth terminal with 32 X 6mm GI flat with all material and labour.(f) Provision of Aviation obstruction lightLED type. (g) Provision of lightening arrestor spike.(h) The Contractor shall submit OEM technical specification of High mast for approval of Accepting Officer before placing order.(j) The Contractor shall submit warranty & TC before claiming payments.(k) Provision of control panel for operation in both auto and manual mode, as per OEM specification. |
| 43 | Material and Labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983and as directed. Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc as per IS and refiiling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable(ii) For the purpose of measurement only punned thickness shall be considered for payment. |
| 44 | Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :-The tenderer shall take into consideration for following points while quoting rate for this item andthe unit rate is deemed to be inclusive for :-(i) Earth work and excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed.(iii) Removing excavated material to out side MD land.(iv)Laying of any type/any bore of pipe in trenches including taking down. Pipe shall be measured and paid separately(v)150 mm thickPCC 1:2:4 type B1 using 20mm graded stone aggregate as inroad to make good existing disturbed surfaces. |
| 45 | Material and Labour for well burnt subclass ‘B’ bricks as mechanicalprotection forunder ground LT electric cables laidalong with length of the bricks equal to the width of the trench complete all as speified and directed . |
| 46 | Supply and Fixing GI tubing light grade 50 mm dia fixed on walls/pole/ laid in trenches as protection pipe for under ground cable including provisioning of specials and clamps etc complete all as speified and directed. |
| 47 | Material and labour in repair for 4 core 6 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/ Polycab/ RPG Asian |
| 48 | Material and labour in repair for 4 core 10 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/ Polycab/ RPG Asian |
| 49 | Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 300x200x100mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified anddirected. |
| 50 | Supply & Erecting Mild steel tubular swaged pole 9 meter long 410, SP-31 complete with cast iron base plate, bracket, finial taper plug, bolt, nuts & screws and painted on both side (internally & externally), external surface painted with two coat of aluminum paint over coat of primer and painting with blackup to 1.5 meter from top of PCC 1:3:6 using 20 mm graded stone aggregate coping white colour paint as in strips of equal width with marking pole numbers by using one coat of synthetic enamel paint including necessary PCC 1:4:8 with 40 mm graded stone aggregate as in foundation and coping as per TD drawing including dismantling of old damaged pole complete all as specified and as directed.Note (i)Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately.(ii) Pole upto 1.5 m top of copping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer. The rate for above items shall be deemed to be inclusive in the quoted rate. |
| 51 | Supply and fix GI bracket for street lights made out of medium grade GI pipe 40mm dia, 1.5 mtr long bent to shape as directed, fixed on poles with necessaryclamp of required sizesuitable for steel tubular pole including suitableGInuts and bolts washers complete all as specified and as directed . |
| 52 | M&L as in repairenergy efficient street light luminaire LED type 70watts,with light sensor, IP66 ,230volts, 50 Hz , in deepdrawn aluminium housingand cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductor and one no of 10 KV External SPD fixing in cable junction box complete all as specified and as directed. Make - Philips /Baja/Havells/CG |
| 53 | Supply and fix9/10 watt LEDPosttop energy saving environmental friendly antique finish with IP 65 Protection completeall as specified and directed Make - Philips /Baja/Havells/CG |
| 54 | Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having12 KW 3 phase 32 Amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor. Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 luxand for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS.Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity. The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal weather proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 typeB1 for grouting of base including taking down unserviceable panel etc complete. The scope of work also comprising the following :-The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, Ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity.The panel should have three operation mode :-1. GSM mode -in this mode light should be switched as per GSM controller\"s preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switches as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The Gsm controller should also compatible for cloud based data transmission for interfacing with web for future use,Password protection for Accessing the control of device via SMS/IVRS complete all as specified and directed. |
| 55 | (a) MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, BCH, Havells)(b)Supply Resign cast CT\"S - set of 3(c)Gsm based smart street light controller.(d) Lux based sensor to operate external as per light intensity.(e)Line Contactor, AC 3duty, 3 phase, 415 volts. 50 Hz , 25 Amps -03 Nos (make - L & T, BCH, Havells)(f)MCB SP 32 Amps- 03 Nos(make -L & T, BCH, Havells)(g)Terminal block suitable for 100 A rating with brass contacts for INPUT/ and 63 A for OUTPUT termination.(h) GSM/Timer/Bypass Mode switch.(j) Panel wiring for control circuit with copper flexible 1.5 sqmm & power wiring 10 sqmm flexible.Make- Tricolite/ Kewintech/HPL |
| 56 | Material and labour forBoring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including HDPE pipes upto 50 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed. |
| 57 | Material and labour in repair for 4 core 16 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/ Polycab/ RPG Asian |
| 58 | Material and labour in repair for 3.5 core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/ Polycab/ RPG Asian |
| 59 | Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 250mm x 200 mm x 105mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified anddirected. |
| 60 | M&L for Octgonal GI poles complete with GI base plate finial taper plug, bolts, nuts and screws,with suitable bracketall as specifiedof height 7 M including necessaryEarth work,PCC foundation copping etc and refixing of all existing fitting fixture from exist in old electric pole complete all as specified and as directed Make - Philips /Baja/Havells/CG |
| 61 | Supply & fix PVC insulated Copper Conductor Cable 1.5 Sqmm, 3 Core Round Flexible for connection of Street Light Fitting, complete all as specified and as directed. Make : Havells/ Plaza/ Finolex |
| 62 | Supply and fixLED 40 wattPosttop energy saving environmental friendly ,design with symmetrical light distribution,clearelandscape luminair(CDL)made in cast aluminium spigot housingand IP 65 Protection all as directed Make - Philips /Baja/Havells/CG |
| 63 | Supply and fixLED 10 WattBollard light made in cast aluminium spigot housing with decorative cleare opal arcylic diffuser and IP 65 protection complete all as specified and as directedMake - Philips /Baja/Havells/CG |
| 64 | Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation complete all as specified and directed..Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global |
| 65 | The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. |
| 66 | (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. |
| 67 | (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. |
| 68 | (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval |
| 69 | (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. |
| 70 | (vi) Copper strip of size 20 x 3 mm shallbe fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately). |
| 71 | (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned. |
| 72 | (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. |
| 73 | (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. |
| 74 | (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. |
| 75 | (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. |
| 76 | (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. |
| 77 | (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period. |
| 78 | (xiv) The electrode shallcarry manufacturer\"s name . |
| 79 | (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. |
| 80 | (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. |
| 81 | (xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. |
| 82 | (xviii)The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material. |
| 83 | (xix) Sign boardof mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge. |
| 84 | Material and labour for Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit completeall as specified and directed.Make : Model SEPC 250 of SAFE TRODE or equivalent in Snaga/ Cubes 6 Global |
| 85 | S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip, complete all as specified anddirected. |
| 86 | Supply, errection, testing and commissioning raising and lowering type not less than 12 Mtr height high mast system shaft in two section suitable for 44m/s wind speed along with head frame, luminaire carriage suitable for upto 08 luminairies in symmetrical arrangement and other accessories manufactured in factory including raising lowering system comprising double drum winch, 5 mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box.HIGH MAST SYSTEM: Height of the mast not less than 12 Mtr, Design standard PLG 07 of ILP, Basic Wind speed as per IS:875 Part III Design life - 25 yrs; Material construction as per S355 grade as per BS EN10 025; Base dia - 360 mm & Top dia - 100 mm; with plate thickness : Bottom - 3mm & Top - 3mm. Cross section of the mast shall be 20 side polygon with BSEN ISO 1461 standard galvanisation. With GI single spike lighting protection finial. The high mast shall have 4 nos of foundatino bolt with a PCD of 445 mm of TS600 type with 24 mm dia and 850mm length. Base plate with a dia of 520 mm and thickness of 25mm LUMINAIRE CARRIAGE: Luminaire carriage shall be made of 40 NB ERW class B MS Pipe with diameter of carriage ring at 450 mm. Construction shall be with 6 arms which are welded and 2 sections capable of holding 08 luminairies. TRAILING CABLE: 5 core 2.5sq mm copper cable with EPR insulation and PCP sheathed. WINCH/POWER TOOL: Winch with double drum, SWL 350 Kg integral motor with 0.75 HP capacity with 6 pole, single speed. STAINLESS STEEL WIRE ROPE: Stainless Steel wire with AISI 304 grade and 7/19 construction wire rope of 5 mm dia and a 2x1350 Kg breaking load capacity including OEM recommendation electrical panel of both Auto and manual mode complete all as specified and directed. Make: Bajaj Model No: BHMRL12B or equivalent make in CG/Phillips. |
| 87 | Note: The rate quoted shall be inclusive of the following:-(a) Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates & templates- complete set(b) Supply of suitable copper conductor cable, glands, lugs and wiring from panel to light fittings- 01 Job(c) Construction of suitable shallow RCC foundation with M-20 grade concrete for the mast considering the safe soil bearing capacity at site as 10 t/m² at 2 metre depth with all material and labour all as per Manufacturer\"s design of foundation drawing as approved by GE.(d)Erection and commissioning of the high mast with the help of suitable equipment. |
| 88 | (e)Provision of GI pipe earthing for mast with 2.5m long 40mm dia GI Pipe including connection to mast earth terminal with 32 X 6mm GI flat with all material and labour.(f) Provision of Aviation obstruction lightLED type. (g) Provision of lightening arrestor spike.(h) The Contractor shall submit OEM technical specification of High mast for approval of Accepting Officer before placing order.(j) The Contractor shall submit warranty & TC before claiming payments.(k) Provision of control panel for operation in both auto and manual mode, as per OEM specification. |
| 89 | Notefor Item No 40 & 86 here in above: (i) The earth work in any strata i.e. excavation,returning filling, removal, RCC foundation with foundation bolts manufactured from special steel with nuts, washers, anchor plate, template and Control paneldeemed to be included in unit quoted rate.(ii) The M&L for LED flood light fittings shall be measured and paid separately under relevant Schedule items. |
| 90 | Supply and fixing LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed. Make : Philips/ Bajaj/CG |
| 91 | Supply and fixing LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed. Make : Philips/ Bajaj/CG |
| 92 | Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panel,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermi proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall be submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. ofpolycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF >0.95 under canopy for easy maintenance . Panel should be fitted outside with one No of 16 A 3 Pole IP65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 Phase and neutral 400Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board all as directed and comprising of the following:- |
| 93 | (a) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 200 Amps ,25 KA- 01 No (Incomer).(b) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 63 Amps ,10 KA- 04 Nos.(c ) Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 No.(d) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(e) Space for spare feeder -01 No.Note :-(i)The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, wiring, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu = 100 % ICs .(v) Make of LT Panel /FPB shall be as mentioned in list of makes (PS). |
| 94 | Supply of Chemical Dosing system having top dia 540mm x bottom dia 480mm x height 575 mm, net capacity 95 -100 Ltr consisting of (i) water inlet line (ii) Dosing pump inlet arrangement (iii) Drain (iv) Overflow (v) Level Gauge (vi) inspection port (vii) Agitator 120 watt 800 - 900 RPM Single Phase flange mounted motor with plastic shaft and impeller along with dosing Injector of the following specification. Adjustable dosing pump max pressure 30kg/cm square & max flow rate 0 - 50 ltr/hr including Y stainer, Power input 3Ph, 415V, 50Hz, 4-pole, Foot Mounted, 200 SPM, etc. complete all as specified and directed. Make: - Model No. VST 1012 of Ravi Enterprise or equivalent as per E-in-Cs make approved.Note:-(a)Old Unserviceable chemical dosing system with connected fitting fixtureshall be deposited to MES store yard. |
| 95 | Supply and fixingin repair 20 mm dia Chlorinated PVC (CPVC) Pipes ofheavy gradeincluding fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. |
| 96 | Supply and fixingin repair 25 mm dia Chlorinated PVC (CPVC) Pipes ofheavy gradeincluding fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. |
| 97 | Supply and fixingin repair Chlorinated PVC ball Valve of size 20 mm dia, suitable forheavy grade ISI marked complete all as specified and as directed. |
| 98 | Supply and fixingin repair Chlorinated PVC ball Valve of size 25 mm dia, suitable for heavy grade ISI marked complete all as specified and as directed. |
| 99 | M&L for plain cement concrete 1:2:4 type B-2 (40mm graded stone aggregate) 100 mm thickness as in staging for water tankssurface finished even and smooth without using extra cement complete all as specified and directed. |
| 100 | Supply and fixing mild steelwork in framed brackets of angle or tees, flat iron, channels, etc with web flanges including plates (plain or chequered) cut to shape, drilled and countersunk of screw, including bending and welding angles, bent to curve shape wherever required necessary, gusset plates, riveting, etc. n exc, 10 kg each bracket, and hanging also fastening and fixing conforming to Gde Fe 290, Gde E-165, incl painting with 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as specified anddirected. |
| 101 | Supply, fixand fabricating high intensity standingLED Glossysign boardof size 4.77X0.05X1.22 Mtr with customized brand color outdoor typemade from 3 mm thick arcylic/polycarbonatetransparent sheet,aluminium combined sheet and two sheets placed back to back sidefixed with pvc sheettosteel square pipe of minimum size 40X20 mm of 16 guage and frame with LED driver . The letter shall be costomized brand colorLED glow arcelic sheetshall be pasted on with weather proof white fluorescent computer cut tape in the Board Note : -(i) Matter for printing shall be provided by the department .(ii) Suitable LED lights and driver is inclusive in the quoted rates. |
| 102 | Supply, fixand fabricating high intensity standingLED Glossysign boardof size 1.84 X0.05X0.93Mtr with customized brand color outdoor typemade from 3 mm thick arcylic/polycarbonatetransparent sheet,aluminium combined sheet and two sheets placed back toback sidefixed with pvc sheettosteel square pipe of minimum size 40X20 mm of 16 guageand frame with LED driver . The letter shall be costomized brand colorLED glow arcelic sheetshall be pasted on with weather proof white fluorescent computer cut tape in the Board Note : -(i) Matter for printing shall be provided by the department .(ii) Suitable LED lights and driver is inclusive in the quoted rates. |
| 103 | Supply, fixand fabricating high intensity standingLED Glossysign boardof circular size of dia 0.92 Mtrwith customized brand color outdoor type made from 3 mm thick arcylic/polycarbonatetransparent sheet,aluminium combined sheet and two sheets placed back toback sidefixed with pvc sheettosteel square pipe of minimum size 40X20 mm of 16 guageand frame with LED driver . The letter shall be costomized brand colorLED glow arcelic sheetshall be pasted on with weather proof white fluorescent computer cut tape in the Board Note : (i) Matterfor printing shall be provided by the department .(ii) Suitable LED lights and driver is inclusive in the quoted rates. |
| 104 | Supply and fix split type flame proof air conditioner 1.5 TR suitable for \"Ex-d IIC\" IP 66 230V AC, 50 Hz single phase, hermetically sealed compressor with flameproof terminal box, R-407 CFC free refrigerent gas, flame proof induction motor of S1 Duty and \" Ex-d IIC\" Zone-IP-66 for indoor cooling unit, material of indoor and outdoor unit is SS 304, copper tubes with aluminium fins, Flame proof control panel, provn of Earthing terminalinside and outside,necessary steel frame structure for indoor and outdoor will be provided as per OEM, Noise as per OEM, warranty period 12 months after installation. Note :- All the accessories i.e copper tube indoor to outdoor, connecting lead as per OEM andinitial refrigerent gas required for connection of split AC unit and making suitable hole in wall for passing the pipe and making good as per exisitng surface and other parts required to install and working of the AC deemed to be included in this item rate all as specified and duly approved by CIMFR Dhanbad , PESO(Nagpur)andBISas manufacturers intructions and complete all as specified and directed. Make - Shyaam Switch GearCat Part No - Product Cat No SSPL/HC/508 or equivalent in Baliga / FlexproFlame proof Control Panel:-Lamps 230 VAC-03 Nos.(Power ON,Cooling Motor ON,Compressor ON) with temprature indicator , 2 relay output, FLP RTD PT 100 3wire. MCB, contactor & Overload relay for protection compressor and condensing motor, cooling motor incomer MCB will be provided. clasification Area -Zone I&II , Gas Groups IIA, IIB, IIC with Dust protection Zone 21&22.Note :- (i) The rates quoted is inclusive of Platform for Outdoor unit and steel stand for indoor unit and copper tubes of indoor and oudoor upto 5 mtr. |
| 105 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA with enclosure for stabilizer complete all as specified and as directed. Make :- Shyaam Switchgears Cat part no SSPL/MCDB/186 or equivalent in Baliga / Flexpro. |
| 106 | M&L for sub main wiring with two single core 4 sqmm multi stranded copper conductor, FRLS PVC insulated, unsheathed cable, including ERWrigid metallic steel conduit medium grade, ISI marked, 19/20 mm dia for sub main wiring including 4.0 sqmm FRLS PVC insulated and unsheathed stranded copper conductor as earth wire in surface/ recess with all MS conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc and making good to the disturbed surfaces to match the existing surfaces completeall as specified and directed.Note:- (i)Three runs of 4.0 sqmm copper conductor cable, and one run of ERW rigid metallic conduit shall be included in quoted rates.(ii) Junction boxes, bends, tees, elbows shall be include in quoted rates. |
| 107 | S&F flame proof junction box with spigotted cover in LM-6, three way/terminal block 4 way strip type cable entry, 20 mm dia hole aluminium constructed, internal dimension 80 mm dia and 40 mm depth, complete all as specified and directed. Make:- Shyaam Switchgears Product Cat No SSPL/JB/105 or equivalent in Baliga / Flexpro |
| 108 | S&F flame proof rotary switch in LM-6, 10/16 Amps with termination box, single pole, 250 volts and enclosed cast aluminium body with threaded cover with switch operated by a sigle pole knob with double entries suitable for 20 mm dia ERW threaded steel conduit as per manufacturers intructions complete all as specified and directed.Make:- Shyaam Switchgear/ Baliga / Flexpro |
| 109 | S&F fix flame proof cast iron enclosure distribution board 415 volts, 6 way, SPN and MCB suitable for explosive atmosphere with explosive including necessary panel board for required connection from busbar to different outgoingand including making good to the disturbed surfaces of walls, floors etc, complete with following incoming and outgoing controls all as specified and directed:- (i)Incoming:- MCB, 2 Pole 32 Amp -01 Nos.(ii) Outgoing:- MCB Single Pole 6-32 Amp - 04 Nos. with complete internal bus bar & wiring up to terminals Make:- Shyaam Switch Gear Product Cat No SSPL/MCDB/186 or equivalent in Baliga / Flexpro |
| 110 | Supply & Fixing of drain outlet PVC 15 mm dia pipe connected from rear side of AC upto drain with necessary clamp and fixtures on wall and floor all as specified and as directed. |
| 111 | Supply and fixing ofCopper tubing of size 1/2\" flare size conforming to relevant IScomplete all as specified and as directed. |
| 112 | Supply and fixing ofCopper tubing of size 1/4\" flare size conforming to relevant IS complete all as specified and as directed. |
| 113 | Note :- An amount of Rs 2,71,254.00 on account of credit schedule for schedule \"A\" part II shall be deducted from the total amount of BOQ to arrive at the contract sum. |