| Sl. No. | Item Description |
| 1 | Taking down & refixing carefully ceiling fan from any height and of any make / type for servicing & overhauling and replacing of rubber bushing, nuts, bolts, pins etc complete all as specified and as directed. |
| 2 | Taking down & refixing carefully exhaust fan from any height and of any make / type for servicing & overhauling and replacing of rubber bushing, nuts, bolts, pins etc complete all as specified and as directed. |
| 3 | M & L for winding of motor of 1200/1400 mm sweep ceiling fan of any make with super enameled copper winding wire of existing gauge including cutting and getting out old burnt winding, sleeve work, varnishing with E-class insulation varnish, threading, connections with twin core copper flexible wire of size 0.5 Sqmm of length not more than one meter with each fan including white/gray synthetic enamel spray painting of fan and blades after rewinding complete all as specified and directed. Make of winding wire : New India/ Jindal/ Devidyal/ HTP. (Note: Rate of re-fixing the fan is not deemed in the rate quoted above) |
| 4 | All as per item No. 3 but exhaust fan 300 mm to 450mm sweep Complete all as specified and as directed. |
| 5 | S&F capacitor 4.0 MFD 230 Volts incl PVC clamps complete all as per specified and directed. |
| 6 | S&F capacitor 2.5 MFD 230 Volts incl PVC clamps complete all as specified and as directed. |
| 7 | S&F in repair hanging clamp with provision of hook made out of MS flat with suitable size all as per site requirement incl nuts bolts washers etc., complete all as specified and as directed. |
| 8 | S&F in replacement exhaust fan, made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, 1200 RPM, copper winding of sweep 250mm complete all as specified & directed. Note: Old UNSV exhaust fan shall be deposited to MES store yard |
| 9 | S&F in replacement ceiling fans complete with blades, down rods and accessories, 230 V, 1200mm sweep min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) without remote complete all as specified & directed. Note: Old UNSV ceiling fan shall be deposited to MES store yard |
| 10 | S&F in replacement exhaust fan, steel body AC single Phase 230V of size 300mm sweep with, blades, frame and louvers complete all as specified & directed. Note: Old UNSV exhaust fan shall be deposited to MES store yard |
| 11 | Supply and fix louvers shutter section fabricated out of GI Sheet of 22 gauge suitable for 230 / 300 / 450 mm dia exhaust Fan complete all as specified and as directed. |
| 12 | M & L for Preventive maintenance of storage type electric water heater (Geyser) of capacity 25/35/50 ltrs comprising of the following tasks at different locations of any make:(Note.: Replacement of defective components such thermostat, safety valves fusible, plug, heating elements, storage tank apparatus plate, insulating material, PRV dead wt valve etc., will be measured and paid separately under relevant items |
| 13 | (a) Inspection of geyser after opening bottom cover plate. (b) Examine water tightness of storage tank.(c) Carry out operation of all stop cocks, pressure reducing valves, etc. to ensure free movement of the working parts.(d) Check and correct temperature setting of thermostats and functioning of indicator lamp.(e) Checking of dead weight type high pressure release valve (PRV) by removing dead weight protection cleaning the seat and ensuring that the waste hole is not blocked / chocked including replacing washers / spring etc. (f) Replacing of fusible plug & ensure it intactness. (g) Descalling of the immersion type heating element and cleaning with diluted hydrochloric acid or cleaning solution and testing.(h) Spray painting of geyser upper surface(i) Testing of geysers after repairs/maintenance in all respect for proper functioning. |
| 14 | Supply & fix heating element of geysers of capacity 1.5 KW including rubber washers triangular/ cup type base (ISI marked) complete all as specified and directed. |
| 15 | Supply & fix heating element of geysers of capacity 2.0 KW including rubber washers triangular/ cup type base (ISI marked) complete all as specified and directed. |
| 16 | S&F electric water heater 25 Ltr capacity, ABS body with SS inner tank and heating element upto 2 KW capacity, 230 Volts, BEE 5 star rated with all accessories such as safety valve, thermostate, NRV, connection piece etc, fixing on wall through proper nut, bolt, and fastner including electric and water connection complete all as specified and directed.Note :- (i) Srl Number of geyser and \"GE (AF) Amla and CA No. shall be marked on geyser with Red/Black colour paint and will be issued by Engineer-in-Charge and cost for the same shall deemed to be included in the quoted unit rate. (ii) Old UNSV geysers shall be deposited to MES store yard. |
| 17 | S&F in repair thermostat ISI marked suitable for geysers upto 50 ltrs capacity, 20 Amps, 240 Volts AC, fixed type, 300 mm long or nearest size, set at 90+/-6 degreeC as per sample (ISI marked) complete all as specified and directed. |
| 18 | S&F in repair geyser bottom assembly of 6 hole/7 hole/9 hole as per existing complete including nuts, bolts and rubber gasket for existing make of 25/35 ltrs geysers as per site requirement complete all as specified and directed |
| 19 | S&F in repair PVC pipe connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sqcm at both ends, 600 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe complete all as specified and directed. |
| 20 | S&F in repair SS pipe connection (304 grade) for hot/ cold water made of double layer SS braidedat a pressure of 6kg/sqcm at both ends, 600 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe complete all as specified and directed. |
| 21 | S&F in repair non return valve 15 mm dia made of bronze suitable for existing size of geysers ISI marked heavy duty complete all as specified and directed. |
| 22 | S&F in repair pressure saftey valve suitable for existing size of geysers ISI marked heavy duty complete all as specified and directed. |
| 23 | S&F in repair cable with copper conductor PVC round sheathed 3 core 1.5 sqmm with stranded copper conductor 1100 V grade from plug top to geyser complete all as specified and directed |
| 24 | Supply and fixing in repair modular type sheet metal enclosure for single pole and neutral with three pin plug top 15 Amp and socket 15 Amp complete with one SP MCB 20 Amps complete all as specified and directed. |
| 25 | S&F in repair 3 pin plug top, 16 Amp, 240 VAC, heavy duty, ISI marked complete all as specified and directed |
| 26 | S&F in repair grouting bolts on wallwith T head 6 MM to 12 mm dia 100 mm long (Set of 2 Nos) for fixing geyser of capacity 25/35/50 Ltr compete all as specified and directed. |
| 27 | S&F wall mounted fan, made of sturdy engineering plastic, voltage 230 V, 50 Hz, RPM 1350 copper winding of sweep 450 mm including connection as required at site complete all as specified and directed |
| 28 | S&F MCB DB SPN 4 way double door sheet metal enclosure comprising of 200 Amps, 415 Volts, 50 Hz bus bar and neutral link complete including inserting in wall complete all as specified and directed. |
| 29 | S&F MCB DB SPN 8 way double door sheet metal enclosure comprising of 200 Amps, 415 Volts, 50 Hz bus bar and neutral link complete including inserting in wall complete all as specified and directed. |
| 30 | S&F MCB DB SPN 12 way double door sheet metal enclosure comprising of 200 Amps, 415 Volts, 50 Hz bus bar and neutral link complete including inserting in wall complete all as specified and directed. |
| 31 | S&F MCB DB TPN 4 way double door sheet metal enclosure comprising of 200 Amps, 415 Volts, 50 Hz bus bar and neutral link complete including inserting in wall complete all as specified and directed. |
| 32 | S&F MCB single pole & neutral \"C\" curve 32 Amps 240 Volt 50 Hz 10 KA complete all as specified and directed |
| 33 | S&F MCB single pole & neutral \"C\" curve 20 Amps 240 Volt 50 Hz 10 KA complete all as specified and directed |
| 34 | S&F MCB single pole & neutral \"C\" curve 40 Amps 240 Volt 50 Hz 10 KA complete all as specified and directed |
| 35 | S&F MCB single pole & neutral \"C\" curve 16 Amps 240 Volt 50 Hz 10 KA complete all as specified and directed |
| 36 | S&F MCB single pole \"B\" curve 6 to 32 Amp 240 volt 50 Hz 10 KA complete all as specified and directed |
| 37 | S&F MCB TP \"B\" curve 25 to 63 Amp 240 volt 50 Hz 10 KA complete all as specified and directed |
| 38 | S&F MCB TPN \"B\" curve 16 to 32 Amp 240 volt 50 Hz 10 KA complete all as specified and directed. |
| 39 | S&F MCB TPN \"B\" curve 40 to 100 Amp 240 volt 50 Hz 10 KA complete all as specified and directed. |
| 40 | M&L for sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 2.5 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable sizeincluding concealed in wall etcone run of PVC insulated with 1.5 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 2.5 sqmm cable, one run of 1.5 sqmm cable and one run of PVC conduit will be measured as one unit. |
| 41 | M&L for sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable sizeincluding concealed in wall etcone run of PVC insulated with 2.5 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 4 sqmm cable, one run of 2.5 sqmm cable and one run of PVC conduit will be measured as one unit. |
| 42 | S&F in repair LED driver for existing 600x600mm size recess fitting, 36/40 W LED fittings, 240 Volts, 50 Hz as per site requirement suitable for existing make of ceiling light complete all as specified and directed. |
| 43 | S&F in repair LED driver for existing bollard lights of 8 to 10 W LED 240 Volts 50 Hz as per site requirement suitable for existing make bollard light complete all as specified and directed. |
| 44 | Fixing only in repair of building security light of any capacity with pre wired and necessary mounting arrangements andthree core copper conductor cable multi stranded from ceiling rose to light fitting including fixing of GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as specified anddirected.Note: Light fitting will be supplied under Schedule \"B\" free for fixing |
| 45 | S& F in replacement of wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driver connector block etc complete all as specified and as directed. |
| 46 | M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. light grade protection pipe for earth lead complete with charcoal and common salt in alternate layer including watering arrangement with galvanized iron pipe medium grade 20mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 ofpart I including excavation and earthwork in any type ofsoil/strata and testing on completion complete all as specified and directed. (Note:- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.) |
| 47 | S&F in replacement switch piano flush type single pole one way 6 amp complete ISI marked complete all as specified and directed. |
| 48 | S&F in replacement modular switch single pole one way 6 amp complete ISI marked complete all as specified and directed. |
| 49 | S&F in replacement socket outlet multipurpose having provision for 2 in 1, 3 oin 5 Amp piano flush type complete all as specified and directed. |
| 50 | S&F in replacement modular socket outlet multipurpose having provision for 2 in 1, 3 oin 6 Ampcomplete all as specified and directed. |
| 51 | S&F in replacement switch piano flush type single pole one way, and 15 amp complete ISI marked complete all as specified and directed. |
| 52 | S&F in replacement modular switchsingle pole one way, and 16 amp complete ISI marked complete all as specified and directed. |
| 53 | S&F in replacement socket outlet 2 in 1, 3 Pin 5 Amps and 15 Amps flush type complete all as specified and directed. |
| 54 | S&F in replacement mdular socket outlet 2 in 1, 3 Pin 6 Amps and 16 Amps complete all as specified and directed. |
| 55 | S&F in replacement bell push flush type 5 Amp complete all as specified and directed. |
| 56 | S&F in replacement modular bell push large piano type single pole one way 240 volts ISI marked complete all as specified and directed. |
| 57 | Supply & fixingstepped type electronic fan regulator flush type on the existing phenolic laminated sheet, etc as required complete all as specified and directed. |
| 58 | S&F in replacement modular ceiling fan regulator suitable electronic rotary step type 120 Watt 2 module ISI marked complete all as specified and directed. |
| 59 | Supply & fix in repair Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal all as specified and directed. |
| 60 | Supply & fix in repair Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal complete all as specified and directed. |
| 61 | S&F in replacementmodular switch piano type 10 Amps one way single pole 240 voltsISI marked complete all as specified and directed. |
| 62 | S&F in replacement modular switch piano type 20 Amps 240 voltsISI marked complete all as specified and directed. |
| 63 | S&F in repair sheet metal enclosure Two Pin Metal Clad Industrial Plug and Socket Fitted with 20A Single Pole MCB complete all as specified and directed. |
| 64 | S&F in replacement of geyser neon red and green light indicators complete all as specified and directed. |
| 65 | Fixing only in repair LED fitting of any type and any capacity complete with driver,three core flexible copper conductor cases of suitable size complete all as specified and directed.Note: LED fittings will be provided under Schedule \"B\" free for fixing. |
| 66 | M&L for servicing of air blast type electrically operated chimney installed in cook houses by dismantling complete filter assemblies / ducts and connected items for descaling with suitable chemical solution / caustic soda including reassembling, testing and painting with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade complete all as specified and directed. |
| 67 | M&L for dismantling unserviceable blower motor 3 phase 415 volts 1400 PRM 3 HP to 5 HP from existing pillar and transporting to civil work shop for repair/rewinding and reassembling the same on foundation and testing includes the followings:- (i) Opening/dismantling electric motor and removing burnt copper winding from starter and cleaning.(ii) M & L for rewinding starter with same gauge of super enameled copper winding wire including fixing of insulating papers, varnishing complete.(iii) S&F of ball bearings to match existing Nos. 2(Make : SKF) |
| 68 | Taking down old/defective energy meter and deposit to MES store. Supply and installation of smart Single Phase Meter with the following specifications:(i)AC Single phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt 865-867 MHz Radio Frequency communication facility with self-healing Mesh network with defalult and on demand display, biling date generation facility, anti-tamper features. Microprocessor and LED/LCD based circuitry.(ii)Meter should support the following data : 30 min instaneous data for voltage, current, power factor, power, cumulative energy and frequency, 30 load survey date for energy, mopntly billing survey for cumulative energy and Max Demand.(iii)Meter should have connect/disconnect functionality operable from prepaid billing software.(iv)The meter should support open communication protocol DLMS with the software. |
| 69 | Note:(a)The contractor would be responsible from removing the existing meter, noting down the reading and depositing it with the MES.(b)It would be possible to run the meter in both prepaid and postpaid mode. (c)The meters would carry 5 year warranty. |
| 70 | Comprehensive preventive & routine maintenance services of 1.5 TR window type air conditioner Make: Voltas/LG /Carrier/Blue Star or any other make on site installed at various location in the station by carrying out following checks and services:-(i) Cleaning of condenser and evaporator coils fins with mild detergent/chemical solution for descaling of coils and flushing with high-pressure jet of water after taking down the whole unit and refixing at the existing location or any other new location after servicing.(ii) Greasing of blower motors and all moving parts.(iii) Prevention of rusting of units(iv) Checking operation of controls of the air conditioner such as thermostat, relays, remote control etc.(v) Checking air flow through the supply air grill, return air grill, condenser.(vi) Checking air temperature at supply air grill, return air grill, inlet air condenser, outlet air from condenser. |
| 71 | (vii) Checking firmness of supporting arrangement for the compressor, blower motor, air conditioners casing and fixing of air-conditioners etc., anti-rusting painting of the MS portion prone to rusting.(viii) Replacement of any component of air conditioners found defective after the above checks and tests. |
| 72 | All as per item No. 68 above but for 1.5/2 TR split type air conditioner.Note for Item No. 68 & 69(a) Cleaning, overhauling and servicing of each unit shall be carried out on quaterly basis.(b) The AC units shall be checked completely and serviced/repaired thoroughly at least once in three months as prescribed by the manufacturer of the AC units. In addition to thisAC units shall be attended on break down with in 24 hours after intimation and shall be get repaired with in 48 hours, failing which necessary recovery @ Rs 200 per AC per hrs shall be made.(c)Items/parts required for repair/replacement shall be measured and paid separately under relevent items here-in-after. |
| 73 | Disconnecting, dismantling and taking out existing burnt out compressor from window/split type Air conditioner 1.5 TR Capacity and supply & fixing sealed unit compresser of existing capacity 1.5 TR, single phase, 230 V AC supply initialy filled with compressor oil complete all as specified by Engr-in-Charge and testing on load for 24 hrs in summer complete all as specified and directed. |
| 74 | All as per item No. 3 above but for 2 TR window/split type air conditioner complete all as specified and directed. |
| 75 | Taking down carefully Split type AC of any capacity with all accessories such as indoor unit, out door unit, copper pipe inlet outlet, flair nut etc. and shifting new position after minor repair including making good the opening of old location with cement mortor 1:3, treating the wall to matching with existing surface finish and making opening holes on brick wall at new location and gap well finish with cement mortor 1:3, making good the wall surface to match with existing surface, installation and commissioning with replacement of insulation of suction & discharge line complete all as directed.complete all as specified and directed. Note: (i) Replacement of any defective parts shall be measured and paid separately. (ii) The charging of gas shall be measured and paid separately. |
| 76 | Supply and fixing dual capacitor (starting & running) range 25+2 to 60+10 MFD, ISI marked for 1.5/2 TR capacity window/ split type AC complete all as specified and directed. |
| 77 | Supply and fixing in repair starting capacitor of 80 to 100 mFd capacity, ISI marked for 1.5/2 TR capacity window/ split type AC complete all as specified and directed. |
| 78 | Supply and fixing in repair running capacitor of 36 to 45 mFd capacity, ISI marked for 1.5/2 TR capacity window/ split type AC complete all as specified and directed. |
| 79 | Supply and fixing in replacement indoor unit blower motor for 1.5/2 TR split AC as per existing make and capacity complete all as specified & directed. |
| 80 | Supply and fixing in replacement condenser fan blade for 1.5/2.0 TR split AC as per existing size and make complete all as specified & directed. |
| 81 | Supply and fixing in replacement condenser fan motor for 1.5/2.0 TR split AC as per existing size and make complete all as specified & directed. |
| 82 | Supply and fixing in repair remote control with PC board complete suitable for existing model of split type AC of any capacity complete all as specified and directed. Make: As per OEM |
| 83 | Material and labour for taking down outdoor/indoor unit of 1.5/2.0 TR split type ACfrom installed position for leak testing & arresting the leakages in condenser coil by brazing or fixing the brass valve of same size and capacity complete all as specified and directed.Note :- Gas Charging shall be mesasured and paid separately under relavent item |
| 84 | Supply and fixingin replacement of refrigerant line copper tubing of size 5/8\" with clamping on wall surface or concealed with both the ends connection or fixing by brazing complete all as specified and as directed. |
| 85 | All as per item No. 81 above but for size 3/8\" complete all as specified and directed. |
| 86 | All as per item No. 81 above but for size 1/2\" complete all as specified and directed. |
| 87 | All as per item No. 81 above but for size 1/4\" complete all as specified and directed. |
| 88 | Material and labour for black rubber AC insulation pipe for copper tubing of size (5/8\") including packing material and PVC tape & tie complete all as specified and directed. |
| 89 | All as per item No. 85 above but suitable for copper pipe for size 3/8\" complete all as specified and directed. |
| 90 | All as per item No. 85 above but suitable for copper pipe for size 1/2\" complete all as specified and directed. |
| 91 | All as per item No. 85 above but suitable for copper pipe for size 1/4\" complete all as specified and directed. |
| 92 | Material and labour for rewinding of fan motor of 1.5/2 TR split AC with suitable size and gauge super enamelled copper winding wire etc complete all as specified and directed. |
| 93 | Supply and fixing in repair indoor unit for 2.0 TR split type AC with copper coil, temperature display with all accessories like blower motor, blower, PCB, remote, etc. complete all as specified and directed. |
| 94 | Supply and fixing in repair electronic circuit board PCB (Multi PCB-AC) suitable for window/split type AC 1.5/2.0 TR capacity as per the existing model & make complete all as specified and directed. |
| 95 | Supply and fixing in repair brass valve 5/8\" suitable for existing split AC of cap 1.5/ 2.0 TR complete all as specified and directed. |
| 96 | All as per item No. 92 above but for size 3/8\" complete all as specified and directed. |
| 97 | All as per item No. 92 above but for size 1/2\" complete all as specified and directed. |
| 98 | All as per item No. 92 above but for size 1/4\" complete all as specified and directed. |
| 99 | Material and labour for charging of refrigerant gas R-410A / 407C to the Window/Split type AC, water coolers and refrigerator after vaccumising the complete system & pressure test with nitrogen to ensure complete system leak proof, testing the appliances complete for cooling effect to the entire satisfaction. Note: contractor has to refill the gas without any additional payment in case of any leakage/less cooling effect. |
| 100 | All as per item No. 96 here-in-before but for refrigerant gas R-134A/32/22 complete all as specified and directed. |
| 101 | Supply and fix in repairs double ended fan motor forWindow AC 1.5 tonwith capacity 1/6 HP complete all as specified and directed. |
| 102 | Supply and fix in repairs double ended fan motor forWindow AC 2 tonwith capacity 1/4 HP complete all as specified and directed. |
| 103 | Supply and fixing PVC flexible pipe 15 mm dia medium grade including all accessories for drain out pipe complete all as specified and directed. |
| 104 | Material and labour for servicing of water coolers of storage capacity 80 to 150 ltrs and cooling capacity 40 to 150 Ltrs per hour, cleaning the water tank by brush, rubbing the inner portion of the tank, washing the tank by bleaching, washing the outer body by clean water complete alongwith cleaning condenser coil with air blower, wet servicing of condensor coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary applying oil in fan motor bushes checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ refrigerent controls, connecting up all connections and testing on completion complete all as specified and directed. Note: Defective Items/parts required for repair/ replacement shall be measured and paid separately under relevent items. |
| 105 | Supply and fixing in repair factory sealed compressor unit of water coolers 40 to 60 Ltrs/hr cooling capacity, connecting refrigeration system after thoroughly flushing out the system and leak testing with CO2, vacuumising and gas charging with refrigerant gas, testing, re-installing in its original position/location connecting up all electrical connections, testing on completion includung taking out burnt / unserviceable compressor unit complete all as specified anddirected. Note:(i) Sealed compressor unit shall be replaced with existing capacity/Make. (ii)Gas charging shall be mesasured and paid separately under relevent item. |
| 106 | All as per item No. 102 here-in-before but for capacity 120 to 150 Ltrs/hrs complete all as specified and directed. |
| 107 | Material and labour for removing the water cooler from position and checking all condensor/ compressor coil, arresting the leakages in condenser coil by brazing etc complete for water cooler 40 to 150 Ltrs/Hr cooling capacity all as specified and directed. |
| 108 | Material and labour for servicing refrigerators 165 to 320 Ltrs capacity complete with cleaning condenser coilwith air blower, cleaning internal body of refrigerator, wet servicing of condenser coil unit with caustic soda etc, repair/ replacement of sheet metal screws, minor parts, wherever necessary, checking and rectifying the wiring defects, tapping the loose wiring by proper insulation tape, proper setting of thermostat & other electrical/ refrigerent controls,connecting up all connections and testing on completion complete all as specified and directed. |
| 109 | Taking out unserviceable/burnt sealed compressor unit of refrigerator of capacity 250/300 Ltrs. Supply & fixing factory sealed compressor unit suitable for 250/300 ltrs capacity refrigerator, connecting with copper piping by brazing & copper tubing and testing on completion complete all as specifed and directed. Notes: (i) Sealed compressor unit shall be replaced with existing capacity/Make. (ii) Gas Charging shall be mesasured and paid separtely under relavent item |
| 110 | Removing refrigerator from position checking, testing and arresting the leakages in refrigerant line/ copper tubbing/cleaning all the related parts rectify the defect of refrigerant line/ copper tubbing or condenser coil by brazing or other means which ever is necessary at siteetc. for refrigerator up to 320 Ltrs complete all as specified and directed. |
| 111 | Supply and fixing in repair freezer fan motor (as per sample) single phase 230 Volt, 50 Hz suitable for refrigerator of capacity 165 to 320 Ltr complete all as specified and directed. |
| 112 | Material and labour for gas welding/brazing of capillary connections in the refrigerant circuit using copper rod for refrigerator/ water cooler/ window-split type AC/ Deep Freezer complete all as specified and directed. Note: Copper Tubing required will be measured and paid separately under relevant item of schedule. |
| 113 | Supply and fixing in repair starting relay box type for refrigerator/deep freezer complete all as specified and directed. |
| 114 | Supply and fixing in repair thermostat switch for refrigerator of any size as per existing make complete all as specified and directed. |
| 115 | Material and labour for repairing and rewinding of blower motor of water cooler of any size capacity complete all as specified and directed. |
| 116 | Supply and fixing in repair of running capacitor 20 to 30 mfd suitable for refrigerator/deep freezer/ water cooler complete all as specified and directed. |
| 117 | Supply and fixing in repair of starting capacitor 40 to 60 mfd suitable for refrigerator/deep freezer/ water cooler complete all as specified and directed. |
| 118 | Repair/servicing of desert cooler of capacity upto 3000/4000 CFM by dismantling the fan, motor, pumps etc., including checking up/ rectification of wire connections, replacement unserviceable parts & accessories, cleaning of the water tank, replacement of piping system, reassembling, painting one coat of synthetic enamel paint over a coat of red (inner and outerside of the desert cooler) oxide /primer after rubbing the all the rust inside cooler body tank side and base with emery paper and if, any leakage in tank by filling black coal paint completeconnecting up and testing all as specified and directed.Note :- (i) Cost of spare parts replaced during the process of repair/servicing shall be measured and paid separately under relevant item herein after.(ii) Labour charges for replacement of spares parts if any required during repair/ servicing deemed to be included in the quoted rate. |
| 119 | Supply & fixing in replacement of fan motor 18\"/20\" sweep, single phase, 3 speed 100% water resistance & dust proof, withstand voltage fluctuation 170-270 V, rust proof totally enclosed with double ball bearing 900-1400 RPM, electric connection with stranded copper cable of3 core 0.75 Sqmm including dismantling of unserviceable electric motor complete all as specified and as directed. |
| 120 | Supply and fixing in repair submersible water pump of desert cooler 230 VoltAC, discharge not less than 750 LPH at head 1.5 mtrs, ISI marked complete all as specified and directed. |
| 121 | Supply and fixing in replacement of wood wool pad (set of 03 Nos) heavy duty suitable for desert cooler of cap 3000/4000 CuM/Hr complete all as specified and as directed. |
| 122 | Supply, install, testing and commissioning steel body desert cooler electric driven 230 Volts AC, having nominal air delivery/capacity 4000 CuM per hour with 80 ltrs tank capacity having filter panel, grill, top of cooler body, cabinet made out of galvanized steel sheet (ISI marked to IS:277 latest) with zinc coating of thickness (nominal) 0.8mm and for sump tank 1.0mm, Fan motor size 500mm ISI marked as per IS:996 (latest), submersible pump, honeycomb filter pads with non-corrosive wire guard with provision of float valve inlet including stand complete all as specified and directed. Note: Old deteriorated/unserviceable desert cooler shall be deposite in AGE E/M store yard. |
| 123 | Supply and fixing 15mm bore PVC float valve high pressure with epoxy coated aluminium rod & high density plastic ball fixed in water cooler storage tank screwed for iron pipe complete all as specified and directed. |
| 124 | Supply and fixing PVC connection pipe 15 mm dia and 450 mm long with nuts/washers on either end, fixed in water cooler storage tank and GI pipe complete all as specified and directed. |
| 125 | S & F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of ±2.5% and of capacity 4 KVA complete all as specified & directed. |
| 126 | S & F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified & directed. |
| 127 | Material and labour for half yearly maintenance, repair and servicing of water purifier, purification capacity form 12 to 25 Ltrs/hr of any type/capacity/make by taking down, dismantling, cleaning and replacing worn out/damaged parts such as carbon filter, UV lamp etc., including reassembling, refixing, connecting up and testing complete all as specified and directed. Note: (i) Cost of spare parts replaced during the process of repair/servicing shall be measured and paid separately as supply only under relevant item herein after.(ii) Labour charges for replacement of spares parts if any required during repair/ servicing deemed to be included in the quoted rate. |
| 128 | Supply only spares required for replacement during the process of servicing/ repairing of water purifier Inline carbon filter suitable for Aqua Guard/ Aqua Plus |
| 129 | All as per item No 125 above butRO membrane capacity 100 GPD suitable for Kent UV, RO, UF+ |
| 130 | All as per item No 125 above but UV Lamp Suitable fo Aqua guard/ Kent purifier |
| 131 | All as per item No 125 above but Diaphragm RO pump with connectors set. |
| 132 | Supply & fixing MS powder coated wall mounting bracket stand for mounting 1.5/2.0 Ton window AC/ outdoor unit of split AC with fastener bolts, nuts and washer fixing on wall complete all as specified and directed. |
| 133 | Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch \"A\" while deriving the Contract Sum for Acceptance. |