| 1 | Supply, installation and commissioning of High Performance Liquid Chromatography (HPLC) with Photodiode Array (PDA) Detector |
| 2 | 1.0 -System Configuration: HPLC system with quaternary gradient pump, autosampler, column oven, PDA detector, regulatory compliant software, 2.0 - Solvent delivery system (Pump), 3.0 -Autosampler, 4.0 - Column oven, 5.0 -Photo Diode Array Detector, 6.0 - software |
| 3 | 7.0 - Equipment Control and Data processing unit |
| 4 | 8.0. Consumables |
| 5 | 8.1 - Reversed-phase C18 (ODS), 250 × 4.6 mm, 5 µm |
| 6 | 8.2 -Suitable guard cartridges (C18 compatible) |
| 7 | 8.3 - Glass vials (1.5/2 mL) with PTFE caps septa- 500 Nos |
| 8 | 8.4 - Amber vials (1.5/2 mL) with PTFE caps septa- 500 Nos |
| 9 | 8.5 - Solvent bottles 1 L, borosilicate, with GL caps |
| 10 | 8.6 - Bottle caps with 4-port solvent inlet adaptors |
| 11 | 8.7 - Inline solvent filters (0.2 µm stainless steel or PTFE) |
| 12 | 8.8 - Waste bottles with safety caps & tubing |
| 13 | 8.9 - Suitable Stainless-steel Union |
| 14 | 8.10 - Syringe filters (13 mm or more, 0.45 µm PTFE)-500 Nos |
| 15 | 8.11 - Syringe filters (13 mm or more, 0.45 µm suitable for aqueous)- 100 Nos |
| 16 | 8.12 - Membrane filters (47 mm, 0.45 µm PTFE) |
| 17 | 8.13 - Membrane filters (47 mm, 0.45 µm for aqueous) |
| 18 | 8.14 - Spare lamps suitable for PDA detector |
| 19 | 8.15 - Flow cells for PDA detector |
| 20 | 8.16 - Maintenance kit (Complete set) |
| 21 | 8.17 - Autosampler: Syringe/loop volumes of 50,100, and 250 μL of each 2 nos |
| 22 | A vibration-free table of suitable strength and stability, with sufficient surface area to accommodate the complete HPLC system along with PC and printer |
| 23 | Non-Comprehensive Annual Maintenance chargesfor 1st year after the warranty period of 3 years |
| 24 | Non-Comprehensive Annual Maintenance chargesfor 2nd year after the warranty period of 3 years |
| 25 | Non-Comprehensive Annual Maintenance chargesfor 3rd year after the warranty period of 3 years |
| 26 | Non-Comprehensive Annual Maintenance chargesfor 4th year after the warranty period of 4 years |
| 27 | Non-Comprehensive Annual Maintenance chargesfor 5th year after the warranty period of 5 years |
| 28 | Supply, installation and commissioning of UltraPerformance Liquid Chromatography (UPLC) with Photodiode Array (PDA) Detector |
| 29 | 1.0 - System Configuration: UPLC system with quaternary gradient pump, autosampler, column oven, PDA detector, regulatory compliant software, 2.0 - Solvent delivery system (Pump), 3.0 - Autosampler/Injector, 4.0 - Column Oven, 5.0 - Photodiode Array Detector, 6.0 - Chromatography Control software |
| 30 | 7.0 - Data Control and Processing Unit |
| 31 | 8.0. Consumables |
| 32 | 8.1 - Reversed-phase C18 (ODS), 150 × 2.1 mm, 3.0 µm (or) lower |
| 33 | 8.2 - Suitable guard cartridges (C18 compatible)- |
| 34 | 8.3 - PTFE Syringe Filter for organic phase samples (13mmX 0.2µm particle size) – 1000 nos. |
| 35 | 8.4 - Syringe Filter suitable for aqueous phase samples (13mmX 0.2µm particle size) – 1000 nos |
| 36 | 8.5 - Membrane Filters (PTFE) for organic solvent (0.2 µm pore size and 47 mm diameter) - 1000 nos |
| 37 | 8.6 - Membrane Filters suitable for aqueous solvent (0.2 µm pore size and 47 mm diameter) - 1000 nos |
| 38 | 8.7-Suitable Solvent Inlet Filter |
| 39 | 8.8 - Suitable Stainless-steel Union |
| 40 | 8.9 - Solvent Filtration Apparatus (47 mm glass filter funnel) with oil-free vacuum pump with two gauges and regulators – 2 no. each |
| 41 | 8.10 - Waste collecting reservoir Capacity up to 8-10 litres, compatible for storage of polar and non-polar solvents. Should be supplied with 30 meters connecting tube- 2 nos |
| 42 | 8.11 - Spare lamps suitable for PDA detector |
| 43 | 8.12 - Flow cells for PDA detector |
| 44 | 8.13 - Maintenance kit (Complete set) |
| 45 | 8.14 - Autosampler: Syringe/loop volumes of 50,100, and 250 μL of each 2 nos |
| 46 | 8.15 - A vibration-free table of suitable strength and stability, with sufficient surface area to accommodate the complete UPLC system along with PC and printer |
| 47 | 8.16 -Semi-Micro Analytical Balance |
| 48 | Non-Comprehensive Annual Maintenance chargesfor 1st year after the warranty period of 3 years |
| 49 | Non-Comprehensive Annual Maintenance chargesfor 2nd year after the warranty period of 3 years |
| 50 | Non-Comprehensive Annual Maintenance chargesfor 3rd year after the warranty period of 3 years |
| 51 | Non-Comprehensive Annual Maintenance chargesfor 4th year after the warranty period of 4 years |
| 52 | Non-Comprehensive Annual Maintenance chargesfor 5th year after the warranty period of 5 years |