| 1 | Schedule \"A\" B/R |
| 2 | Surface dressing not exceeding 15 cm deepand getting out In soft/ loose Soil, complete all as specified and directed by Engineer-in-Charge. |
| 3 | Excavating in trenches, not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and depth not exceeding 1.5 Metre, and getting out in soft/loose soil, complete all as specified and directed by Engineer-in-Charge. |
| 4 | All as per item No 2 above, but depth exceeding 1.50 Metre but not exceeding 3.00 Metre, complete all as specified and directed by Engineer-in-Charge. |
| 5 | Material & Labour for PCC 1:4:8 type D-2 (using 40mm graded aggregate) in foundations, filling and mass concrete, complete all as specified and directed by Engineer-in-Charge. |
| 6 | Material & Labour for RCC M-30, using 20mm graded stone aggregate for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed by Engineer-in-Charge. |
| 7 | Use and waste of formwork to the sides of concrete footing, base of columns, plinth beams and similar work for vertical or to batter rough finished surfaces of concrete, complete all as specified and directed by Engineer-in-Charge. |
| 8 | Material & Labour for RCC M-30, using 20mm graded stone aggregate, as in Columns, pillars, piers, posts and struts, complete all as specified and directed by Engineer-in-Charge. |
| 9 | Use and waste of formwork to the sides of rectangular columns for rough finished surfaces of concrete, complete all as specified and directed by Engineer-in-Charge. |
| 10 | Material & Labour for RCC M-30, using 20mm graded stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed by Engineer-in-Charge. |
| 11 | Use and waste of formwork to sides and soffits of beams, bands and the like for rough finished surface of concrete, complete all as specified and directed by Engineer-in-Charge. |
| 12 | Material & Labour for RCC M-30, using 20mm graded stone aggregate, as in chajja & canopy,complete all as specified and directed by Engineer-in-Charge. |
| 13 | Use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n. exc. 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 10cm but n. exc. 20cm wide, complete all as specified and directed by Engineer-in-Charge. |
| 14 | Form work to chullah hoods, chajjas, trough and similar items including edges rough finished flat surfaces, complete all as specified and directed by Engineer-in-Charge. |
| 15 | Material & Labour for RCC M-30, using 20mm graded stone aggregate, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed by Engineer-in-Charge. |
| 16 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified and directed by Engineer-in-Charge. |
| 17 | Material & Labour for RCC M-30, using 20mm graded stone aggregate, as in Fins, fascias, louvres, parapets, and railings exc.60cm in height, newels, balustrade, and the like, complete all as specified and directed by Engineer-in-Charge. |
| 18 | Use and waster of formwork to fins, louvers, fascia, parapet etc., complete all as specified and directed by Engineer-in-Charge. |
| 19 | Material & Labour for Mild steel CRS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-in-Charge. |
| 20 | All as per item No. 18 here-in-before, but 6mmto 8mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 21 | All as per item No. 18 here-in-before, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, complete all as specified and directed by Engineer-in-Charge. |
| 22 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm as in soft/loose soil, complete all as specified and directed by Engineer-in-Charge. |
| 23 | Material & Labour for Moorum/red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering, complete all as specified and directed by Engineer-in-Charge. |
| 24 | Removal of excavated soil to a distance exceeding 500 Metre but not exceeding 1000 Metre and depositing where directed at level not exceeding 1.5 Metre above the starting point, complete all as specified and directed by Engineer-in-Charge. |
| 25 | Material & Labour for Pre-cast cement concrete block masonary C-1 (1:3:6) 20mm graded aggregate with solid blocks, exc. 10cm in width and setting in Cement Mortar (1:6), complete all as specified and directed by Engineer-in-Charge. |
| 26 | Material & Labour for rendering 15mm thick, cement plaster, in cement mortar (1:4) in two layer one layer of 10mm thick and another 5mm thick layer mixed with integral water proofing compound as per manufactures instruction, on roof slab surfaces finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.Note:- Water proofing compound shall be measured and paid separately. |
| 27 | Supply only liquid water proofing compound as per manufacturer\"s instructions, complete all as specified and directed by Engineer-in-Charge. |
| 28 | Material & Labourfor rendering 10mm thick on fair face of brick work or concrete surfaces in Cement Mortar 1:6 finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 29 | Material & Labour for rendering 5mm thick cement plaster in cement mortar 1:3 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement on ceiling in any height, complete all as specified and directed by Engineer-in-Charge. |
| 30 | Material & Labour for preparation of surfaces and applying three coats of white wash on new plastered surfaces over a coat of putty on ceiling, complete all as specified and directed by Engineer-in-Charge. |
| 31 | Material & Labour for preparation of new plastered surfaces of wall and applying two coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/ltrs and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm all as per the manufacturer’s instructions, complete all as specified and directed by Engineer-in-Charge. |
| 32 | Material & Labour for preparation of newly plastered surfaces of wall and applying two coats of OBD over a coat of wallputty, complete all as specified and directed by Engineer-in-Charge. |
| 33 | Material & Labour for rendering 10mm thick on fair face of brick work or concrete suraface in Cement Mortar 1:3, finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 34 | Material & Labour for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) including tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per Sqm including cleaning concrete surface by forced application, complete all as specified and directed by Engineer-in-Charge. |
| 35 | Material & Labour for 125mm x 60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed, complete all as specified and directed by Engineer-in-Charge. |
| 36 | Material & Labour for 40mm Flush shutters, solid core construction, with block board core and one face is covered with decorative face veneer with lipping/frame to match, fixed in repairs, complete all as specified and directed by Engineer-in-Charge. |
| 37 | Supply & Fixing anodised aluminium Powder coating ventilator shutters, fixed type without sash bars aluminium section weighing 0.55Kg/m including glazing with 4mm thick tinted glass necessary joining cleats, glazing clips, rubber neoprene packing , anodised aluminium snap beading screws, complete all as specified and directed by Engineer-in-Charge. |
| 38 | Supply & Fixing powder coated aluminium anodised three track sliding window shutter and frame including jointing cleat for fixing frame/chowkhat of window as per JINDAL section code (frame 20831), shutter (20846) including glazing with 4mm thick tinted glass (02 shutters) & SS wire mesh (01 Shutter) necessary fittings, rubber packing, suitable handles, rollers for shutters and locking arrangement etc., complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supply & Fixing Anodized aluminium grills of type Doco grill DG 104 or equivalent with Aluminium section of size 7.5mm x 6 mm with necessary channels and clips, complete all as specified and directed by Engineer-in-Charge. |
| 40 | Material & Labour for 200mm long, Aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed by Engineer-in-Charge. |
| 41 | Material & Labour for 150mm extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed by Engineer-in-Charge. |
| 42 | Material & Labour for 100mm long stainless steel Butt hinges, best quality, complete all as specified and directed by Engineer-in-Charge. |
| 43 | Supply & Fixing 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed by Engineer-in-Charge. |
| 44 | Material & Labour For Hard-core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and directed by Engineer-in-Charge. |
| 45 | Material & Labour for 75mm thick PCC (1:3:6) type C-2 using 40mm graded aggregate as in sub bases of flooring, complete all as specified and directed by Engineer-in-Charge. |
| 46 | Material & Labour for 75mm thick plain cement concrete B-2, 1:2:4 (using 40mm graded crushed stone aggregate) as in plinth protection finished fair and even without using extra cement, complete all as specified and directed by Engineer-in-Charge.Note:- The plinth protection shall be laid in panels and length of the each panel shall not be more than 2.00 mtr all as directed. 6mm joints filled with 85/25 grade bitumen and sand (1:3 ratio) shall be provided. No deduction for joints shall be made while making payment against the above item. |
| 47 | Material & Labour 18mm thick Granite (of any type)work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over screed bed or bedding layer of 15mm thick Cement Mortar 1:6 etc., complete all as specified and directed by Engineer-in-Charge. |
| 48 | Material & Labour for Machine cut kota stone slab flooring 20-25mm thick over 15mm thick screed bed of cement mortar (1:4) including jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and directed by Engineer-in-Charge. |
| 49 | All as per serial item No .47 above but as in vertical surfaces such as skirting’s over 10mm thick rendering on fair faces of brick work in cement mortar 1:4, complete all as specified and directed by Engineer-in-Charge. |
| 50 | Material & Labour for treating the backfill in contact with foundation at the rate of 7.5 Litres of emulsion per Square Metre of vertical surface (Area of the sub structure in contact with backfill to be measured), complete all as specified and directed by Engineer-in-Charge. |
| 51 | Material & Labour for treating the top surface of filled earth at the rate of 5 Litres of emulsion per Square Metre of surface, complete all as specified and directed by Engineer-in-Charge. |
| 52 | Material & Labour for treating the soil under plinth protection at the rate of 5 Litres of emulsion per Square Metre of surface area, complete all as specified and directed by Engineer-in-Charge. |
| 53 | Supply & Fixing 110mm PVC (SWR) pipes double socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed by Engineer-in-Charge. |
| 54 | Supply & Fixing 110mm dia PVC (SWR) bends fixed as required, complete all as specified and directed by Engineer-in-Charge. |
| 55 | Material & Labour for Hard-core of gauge exceeding 63mm but not exceeding 100mm deposited spread and levelled in layers not exceeding 15cm thick watered and reamed to a true surface with broken stone or boulders, complete all as specified and directed by Engineer-in-Charge. |
| 56 | Material and labour for 100mm thick Plain Cement concrete type B-2, 1:2:4 (using 40mm graded aggregate) as in base floors, complete all as specified and directed by Engineer-in-Charge. |
| 57 | Material & Labour for laying machine pressed precast concrete interlocking reflective coloured pavers block any shape and size confirming to IS 15658-2006 of 55mm to 60mm thick, M-35 Grade, including interstices filling with fine sand etc., complete all as specified and directed by Engineer-in-Charge. |
| 58 | Material & Labour for 25mm thick sand layer for laying interlocking paver blocks, complete all as specified and directed by Engineer-in-Charge. |
| 59 | Material & Labour for Rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even and smooth w/o using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 60 | Material & Labour for providing and laying or near ground level factory made Kerb stone of M-25 cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand) including making joint with or without grooves (thickness of joints except as sharp curve shall not be more than 5mm ), including making drainage opening where ever required, complete all as specified and directed by Engineer-in-Charge. |
| 61 | Material & Labour for cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate as in coping, moulded or chamfered edges and like, complete all as specified and directed by Engineer-in-Charge. |
| 62 | Schedule \"A\" E/M |
| 63 | Material & Labour for Point wiring complete with 1.5 Sqmm single core PVC insulated but unsheathed multi-stranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non-metallic rigid PVC heavy duty concealed conduit (minimum 20mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable as earth continuity wire for modular wiring, complete all as specified and directed by Engineer-in-charge. for the following:- |
| 64 | One light point /fan point controlled by one switch with cable 1.5 Sqmm |
| 65 | One 3 pin socket outlet 5 Amps on the same board with other switches with cable of size 1.5 Sqmm nominal area |
| 66 | One 3 pin socket outlet 5 Amps independent board withcable 1.5 Sqmm nominal area. |
| 67 | Material & Labour for Point wiring complete with 2.5 sqmm single core PVC insulated but unsheathed multi-stranded copper conductor FRLS cable 1100 Volts grade drawn through and including PVC heavy duty conduit (minimum 20mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part-1, ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 2.5 sqmm PVC insulated but unsheathed multi-stranded copper conductor FRLS cable as earth continuity wire, complete all as specified and directed by Engineer-in-charge. for the following:-(a) one 3/5 pin 15/16 Amps socket. |
| 68 | Supply & Fixing Modular switch 1 way, 10 Amps, 1 module, complete all as specified and directed by Engineer-in-charge. Make:- Legrand (Arteour) / Schneider (zencelo) / hager (berker) |
| 69 | Supply & Fixing Modular switch 1 way, 16 Amps, 1 module, complete all as specified and directed by Engineer-in-charge. Make:- Legrand (Arteour) / Schneider (zencelo) / hager (berker) |
| 70 | Supply & Fixing Modular socket, 6 Amps, 2/3 pin combined 2 module, complete all as specified and directed by Engineer-in-charge. Make:- Legrand (Arteour) / Schneider (zencelo) / hager (berker) |
| 71 | Supply & Fixing Modular socket, 6/16 Amps, 2/3 pin combined 2 module, complete all as specified and directed by Engineer-in-charge. Make:- Legrand (Arteour) / Schneider (zencelo) / hager (berker) |
| 72 | Supply & Fixing Modular fan regulator, 120 watt, 2 module (ISI marked), complete all as specified and directed by Engineer-in-charge. Make:-Legrand (Arteour) / Schneider (zencelo) / hager (berker) |
| 73 | Supply & Fixing 6 Amp, 250 V high quality robust surface/ flush type polycarbonate/ PVC ceiling rose, conforming to IS: 371- 1979, having 2/3 terminals and outside diameter not less than 63.5 mm, complete all as specified and directed by Engineer-in-charge. Make:- Anchor/ Crabtree/ Cona |
| 74 | Supply & Fixing modular metal flush box 3 module ISI marked), complete all as specified and directed by Engineer-in-charge. Make:-Legrand/Schneider/Hager |
| 75 | Supply & Fixing modular metal flush box 6 module ISI marked), complete all as specified and directed by Engineer-in-charge. Make:- Legrand/Schneider/Hager |
| 76 | Supply & Fixing modular metal flush box 12 module ISI marked), complete all as specified and directed by Engineer-in-charge. Make:- Legrand/Schneider/Hager |
| 77 | Supply & Fixing modular cover plate with frame, 3 module (ISI marked), complete all as specified and directed by Engineer-in-charge. Make:-Legrand / Schneider / Hager |
| 78 | Supply & Fixing modular cover plate with frame, 6 module (ISI marked), complete all as specified and directed by Engineer-in-charge. Make:-Legrand / Schneider / Hager |
| 79 | Supply & Fixing modular cover plate with frame, 12 module (ISI marked), complete all as specified and directed by Engineer-in-charge. Make:-Legrand / Schneider / Hager |
| 80 | Material & Labour for Sub main wiring with two runs of 4.0 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable fire retardant low smoke drawn through and including PVC concealed conduit heavy duty grade ISI marked 25mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I including conduit accessories like bends, tees, junction boxes etc including 4.0 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire fixed, complete all as specified and directed by Engineer-in-charge. |
| 81 | Supply & Fixing 20 Watt surface/ wall mounted LED batten, aluminium housing, operating voltage 140-270, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to LED batten fitting, complete all as specified and directed by Engineer-in-charge. Make: Wipro Cat Part No. LL20-281-XXX-65AL1 / Philips Cat Part: BN108C LED 20S PSU NW WH or equivalent make mentioned in Appendix \"B\". |
| 82 | Supply & Fixing BEE five star rated energy efficient high-speed ceiling fan having 1200mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a downroad of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan, complete all as specified and directed by Engineer-in-charge. |
| 83 | Supply and fixing MCB (DB) SPN 8 way double door 415 V made of sheet metal enclosure for MCB\"s as incomming and SPN/SP MCB as outgoing, complete all as specified and directed by Engineer-in-charge. |
| 84 | Supply and fixing MCB SPN pole 240 Volt C curve 10 KA, ISI marked as per IS/IEC 60898-1 2002 of 6-32 Amps capacity IP 20, complete all as specified and directed by Engineer-in-charge. |
| 85 | Supply and fixing MCB SP 240 Volt C curve 10 KA, ISI marked as per IS/IEC 60898-1 2002 of 6-32 Amps capacity IP 20, complete all as specified and directed by Engineer-in-charge. |
| 86 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 Core, complete all as specified and directed by Engineer-in-charge. |
| 87 | Supply and laying double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 (Part I and II) for protection of underground cables of size 63mm outer dia with all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection, Complete all as specified & directed by Engineer-in-Charge. Note:- Excavation and earth work shall be measured and paid separately Make: Rex/Poly/Gemini |