Tender For Various Sanctioned Works At Age B/R Ii Under Ge Shillong (Tender I); 1 Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed 2 Taking down old defective chowkhats with shutter (without taking off shutters from the frame) n.exc 1.5 sq.m eachand removing away from site, complete all as specified and as directed. 3 M&L mild steel work as in bands, straps, supports or stays for rain water, ventilating pipes including bolts, if required, hooks (stay) heavy for large gates, hooks and pintle hinges, large hasp and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans and similar articles conforming to Fe-290 Gde E-165 complete all as specified and as directed. 4 M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate inroof kerbs or mud stops, rounded or chamfered on edges or slab staging for water tank or filling of chowkhats complete all as specified and as directed. 5 S&F 2nd class hardwood plain, solid, straight chowkhats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and as directed. 6 S&F 35 mm thk Flush door shutters solid core construction with block board core and ply wood face pannels commercial veneered on both faces complete alll as specified and directed. 7 S&F of 35mm thick 2nd class hard wood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed. 8 MSupply and fixing 2nd class HW 35mm thickGlazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares(without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats as specified in SSR Part-I section 8 Clause 8.24 (a) complete all as specified and as directed. 9 Supply and fixing of solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed. 10 S&F of Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rails on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying & fixing in the frame at site as per specification & drawing, complete all as specified and as directed. 11 M & L for powder coated (colour) aluminium frame for doors, windows, ventilators (thickness of powder coating not less than 50 micron) with one or more rebates including joining cleat for fixing including handle, tower bolt, door stopper, grills etc. complete all as specified and as directed. Note:- Design/ pattern, profile sizes and other dimensions shall be of standard size and as directed. 12 M & L for powder coated Anodised aluminium window andventilator shutters, side hung typewithout sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 No.) suitable handle (1 No.) completeallasspecified and directed. 13 Supply & fix sheet glass, ordinary quality, 4.8 mm thick and glazed with oil putty or fixed with beads in square exceeding 0.5 Sqm in each pane complete all as specified and directed. 14 Dismantling of wrought or mild steel work of any description such as in ladder work, bracing/supporting angle iron, roof top MS sheets, railings etc. complete all as specified and directed. 15 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed. 16 Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. 17 M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 18 S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed. 19 S & F 200 mm size, mild steel barrel tower bolts with mild steel barrel and mild steel bolt, dia of bolt 10 mm, bolt finished bright, other parts finished stove enamelled black complete all as specified and as directed. 20 S & F mild steel, pressed oval type, 150 mm size, stove enamelled black finish complete all as specified and as directed. 21 S & F mild steel sliding door bolts, type I (plate type), size 250 mm, stove enamelled black finish to back plate, straps and staple, electroplated finish with nickel and chromium to hasp and bolt, bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed. 22 S & F 100 mm size, mild steel barrel tower bolts with mild steel barrel and mild steel bolt, dia of bolt 10 mm, bolt finished bright, other parts finished stove enamelled black complete all as specified and as directed. 23 S & F mild steel, pressed oval type, 100 mm size, stove enamelled black finish complete all as specified and as directed. 24 S & F floor door stoppers made out of aluminium alloy pressure die casting body and tongue with hard drawn steel wire spring, overall length of cover plate 140 mm, 4.5 mm thickness of cover plate, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, suitable for 30 & 35 mm thickness of door shutter, fixed in floor complete all as specified and as directed. 25 S & F in repairs galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised steel wire staples complete all as specified and as directed. 26 M & L in repairs for 4 mm thick plain fibre cement flat sheets type B, any category as per IS 14862: 2000 (non-asbestos) building boards, fixed to timber/GI /Aluminium framework with screw in ceilings flat or sloping complete all as specified as directed by the Engineer-in-Charge. 27 Dismantling wooden fillets, rails, posts, rafters, purlins, etc. under 40 sqcm in section in unframed works, in any position complete all as specified and directed. 28 M & L for anodised aluminium snap grid frame work for false ceiling of size 605 mm x 605 mm in true horizontal level complete all as specified and as directed. 29 M & L for Hangers 6mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by mean of ceiling cleats made out of G.I. flat 40x3 mm size long, grid 605mm x 605mm complete all as specified and as directed. 30 M&L for forming jambs, etc.to openings CM 1:6 (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete alll as specified and directed. 31 Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc. 32 M&L for 20mm thick granite (of any type), work in cooking platform, in toilets for fixing wash hand basin, counter slab (table rubbed and polished), in steps, jambs, pillars, window cills and like, fixed in cement mortar 1:4 including pointing in white cement 1:2 using granite / marble dust with admixture of pigment to match with shade of granite, laid over and including 15 mm thick cement screed in CM 1:4, complete all as specified and as directed. 33 M & L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed. 34 M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top: (i) Taking out old roof tratment and roughening tha same old concrete slab by picking, sweepingc clean and washing down with water to remove dust etc. (ii) Screed bed or bedding layer of mortar 15mm thick in CM 1:4 for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement (WPC shall be measured and paid seperately) (iii) Cleaning the plastered roof surface and applying one coat of cold bituminuous primer @ 0.25 ltr/Sqm confirming ti IS: 3384 -1986 (iv) APP based polymeric menbrane 3mm thick (minimum) weighing 3.5 kg/Sqm reinfiorced with polyster non woven fabric (weighing not less than 160gms/Sqm) shall be less appliedb over bituminous primer as specified above over a application of polymeric membrane shall by torch application. The overlaps shall be minimum 100mm on the teransverese direction and 75mm on longitudinal direction. (v) Applying one coat of aluminium paint over the APP modified membrane @ 0.11Kg/sqm. 35 Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. 36 Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 37 Cutting chases in stone, concrete block walls & slabs to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., not exceeding 10 cm girth and making good the same with cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate or cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 complete all as specified and as directed. 38 Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. 39 Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 40 S & F in repairs 15 mm nominal size, nonrising spindle type fancy stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed. 41 S & FIN REPAIRS,wall mixer with and including over head shower with 115 mm long bend pipe on upper side, connecting legs and wall flangescomplete all as specified and as directed. 42 S&FIN REPAIRS,bib taps with wall flange, fancy type, quarter / half turn, chromium plated, long body with capstan head and cup, screwed down, screwed for iron pipe or for brass ferrule including accessories, suitable for bore of pipe 15 mm, complete all as specified and as directed. 43 S & F in repair 15 mm bore CP fancy type 2 in 1 bib tap longbody cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. 44 S & F in repair of mild steel brass chromium plated health faucet (ABS body) for 15mm bore pipe and 1.25m long and flexible tube and ABS wall hook including making connection and fixed in position complete all as speified and directed. 45 S & F in repairs brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed. 46 S & F in repairs 20 mm dia harrison rails, anodised aluminium alloy with fixing brackets, stops, rollers etc. complete all as specified and as directed. 47 S & F in repairs 600 mm X 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. 48 M & L in repairs for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed. 49 S & F in repairs vitreous china wash down water closet pan (Pedestal pattern) with P or S trap white (excluding flushing cistern) including connection to trap and cistern, flush pipe including white plastic water closet seat cover, closed pattern with flat bottom & cover and aluminium anodised hinging device including 10 litre capacity PVC flushing cistern and making good disturbed surface of floor, complete all as specified and as directed. 50 S & F 10 litres cap PVC, valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with 32mm dia PVC pipe 600 mm long and PVC connection pipe 15mm bore with PTMT nuts of length 450mm complete all as specified and directed. 51 S & F in repair vitreous china counter type wash hand basin, ovel shape size 450 mm x 300 mm including brackets including32 mm PVC waste coupling andPVC waste pipe 32mm bore complete all as specified and as directed. 52 S&FIN REPAIRS, Pillar taps, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe 15 mm bore complete all as specified and as directed by Engineer-in-charge at site. 53 S & F in repairs sink made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers & 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to draft wall or including fixing cantilever brackets & connecting union to pipe, overall size 495 mm X 420 mm, bowl size 410 mm X 330 mm X 160 mm complete all as specified and as directed. 54 S & F in repairs to 600 mm long PVC flexible Waste pipe to WHB/urinals/Sink complete all as specified and as directed. 55 S&F in repairs Corner Glass Shelf of size 300 mm with chromium plated bracket guard and railing, complete all as specified and as directed. 56 S&F in repair PVC (SWR) Pipes single socketed in any length with rubber ring joints, 110 mm bore fixed to walls/floor, complete all as specified and as directed. 57 S&F PVC(SWR) pipes 75mm dia single socketed in any length with rubber ring joints fixed to walls/floor complete including clamps for securing pipe, complete all as specified and as directed. 58 S & F in repair SWR vent cowl, 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed. 59 S&F in repairs PVC (SWR) bend with access door of110mm bore complete all as specified. 60 S&F in repairs PVC (SWR) bend with access door of75mm bore complete all as specified. 61 S & F PVC Tee (87.5⁰) single, 110 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and directed. 62 Supply and fix in repairs PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed. 63 S&F in repair rotational moulded polyethylene water storage tank 500 litre capacity of triple layered layer wall construction (Cylindrical, vertical with closed top) hoisted and fixed in position including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule all as specified and as directed 64 S & F in repairs 20 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete 65 S & F in repairs ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm size, minimum weight 210 grams complete all as specified and as directed. 66 M & L for precast RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:6) complete with joints to match complete all as specified and as directed. (Note: Reinforcement shall be measured and paid seperately) 67 M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height complete all as specified and as directed. 68 Demolition of reinforced cement concrete of any description (reinforcement cut as required to facilitate demolition) and in any position, above or below ground floors, not otherwise specifically provided for complete all as specified and as directed. 69 Dismantling wooden boarding, any description, fixed in any position with nails complete all as specified and as directed. 70 S & F of 20mm thick, second class hard wood boarding,plane on one side with butt joints and fixed complete in position as in eaves board, etc. complete allas specified and directed. 71 Taking down cement plaster, any description, on brick or stone walls, etc.including racking out joints, hacking for key, scrubbing down with water, etc. including removal of rubbish material away from site, complete all as specified and as directed. 72 Material and labour for plastering 15 mm thick (in two layers of 10mm and 5mm thk) on fair faces of brick wall or concrete surfacesin cement mortar 1:4 with water proofing compound as per manufacturers printed instruction finished even and fair complete all as specified and directed. Note: Water proofing compound shall be measured and paid for separately. 73 Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and fair without using extra cement complete all as specified and as directed. 74 Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces as in ceiling in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and as directed. 75 Supply only integral water proofing compound complete all as specified and directed. 76 M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of suitable primer with auto roller over 1 mm thick putty to match the surfaces complete all as specified and as directed. 77 M&L for preparing newly plastered surfaces of ceiling andapplying three coats of whitewash complete all as specified and as directed. 78 M&L for complete removal of existing treatment and applying two coats of 100% Premium acrylic emulsion paint havingVOC less tham 50 gm/ltrs and UV resistance as per IS 15489:2004, alkali and fungal resistanxe dirt resistance exterior paint of required shade with silicon additives @1.43 ltrs/10sqm over and including priming coat of exterior primer applied @0.90 ltrs/10 sqm over a coat of 1mm thick wall care putty to achieve a smooth surface complete all as specified and directed. 79 M&L for preparation of new surfaces and applying two coats of 100% Premium acrylic emulsion paint havingVOC less tham 50 gm/ltrs and UV resistance as per IS 15489:2004, alkali and fungal resistanxe dirt resistance exterior paint of required shade with silicon additives @1.43 ltrs/10sqm over and including priming coat of exterior primer applied @0.90 ltrs/10 sqm over 1mm thick exterior putty on new surfaces complete all as specified and directed. 80 M & L for complete removal of existing treatment of wall and applying two coats of oil bound distemper over a coat of suitable primer with auto roller over 1mm thick wall care putty complete all as specified and as directed. 81 Preparation of old decorated surfaces on ceilings and applying two coats of white wash complete all as specified and as directed. 82 Demolition of ashlar facings, dressed stonework, precast concrete articles and precast concrete block walling built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed. 83 M & L for precast cement concrete solid block masonry of grade C(5.0) with concrete M 10 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate exceeding 10 cm in width and set in cement mortar (1:6) complete all as specified and as directed. 84 Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) and complete all as specified and as directed. 85 M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as in plinth protection all as specified and as directed. 86 M & L for cement concrete in foundation, filling and mass concrete in M5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 87 M & L for cement concrete in surface channels and drains in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 88 M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed. 89 S & F 40 mm Continuous (piano) hinges,brass complete all as specified and directed. 90 S & F in repair 12mm thick Block boards grade 1 quality exterior grade commercial type fixed with screws to timber frame complete all as specified and as directed. 91 S&F 18/19 mm thick block boardsgrade 1 quality exterior grade commercial type, fixed with screws to timber frame complete all as specified and directed. 92 M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. 93 S & F 1 mm thick, type S (Standard type), wear index No. 3, Impact Index No. 2, Scratch Index No. 3, one side decorative, laminate as per IS 2046: 1995 of surfaces finish, colour and pattern as per approved, fixed with approved adhesive as per manufacturers instructions complete all as specified and directed by Engineer-in-charge. 94 M & L for structural timbers of group B, first or second choice as per IS 3629: 1986 in fillets, square, rectangular, triangular in section, bull nosed, splayed, chamfered or rounded on one edge or face, clean sawn, secured with screws, cross sectional area exceeding 6 sqcm but not exceeding 13 sqcm complete all as specified & as directed. 95 S&F Magnet catches for cupboard shutter, brass body and striking plate including letting in all as specified and as directed. 96 S & F cast brass handle, cast type, 75 mm size, nickel chromium plated finish as per service grade number 1 of IS 1068: 1993 complete all as specified and as directed. 97 S&F soap dish chromium plated fixed to wall with chromium plated brass screws and plastic cleats complete all as specified and directed. 98 S & F in repairs brass chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed. 99 S & F in repairs corner sheet glass shelf assembly consisting of 8 mm thick glass sheet shelf, 30 cm wide with chromium plated screwed down for fixing to wall with screws complete all as specified and as directed. 100 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises 101 M&L for Non Skidjoint free coloured Ceramic tiles 7 to 8 mm thick (square or rectangular),area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile, laid over and including screed bed or bedding layer of mortar, 15 mm thick, in CM 1:4 complete all as specified and as directed. 102 M&L for Glazed ceramic tiles on vertical surface of size 450X 350X 7-8mm or 300x200x7-8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with shade of the tiles laid over and including 10mm thick rendering as backing coatin CM 1:4 with wire markings to receive tile over it, complete all as specified and as directed. 103 M&L Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and as directed. 104 M&L Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in dado , skirting and riser etc, set and jointed in cement slurry and pointed in white or colour cement to match over and including 10 mm thick backing course in cement sand mortar 1:4 complete all as specified and directed 105 M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and as directed. 106 M & L for machine cut Kota stone slab flooring 20 to 25 mm thick over cement screed bed of 20 mm thick in cement mortar 1:4, laid and jointed with grey cement slurry, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. 107 M & L for machine cut Kota stone flooring 20-25 mm thick over and including backing coat in cement mortar (1:4), 10 mm thick as in skirting /dado laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete. 108 M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed ineat cement slurry in floors with grey pigments cement and pigments and including 15 mm thick screed bed in cement sand mortar 1:6 complete all as specified and as directed. 109 Dismantling of plain or corrugated steel sheeting, any gauge, thickness including any pattern roof coverings complete all as specified and as directed. 110 M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering/ wall clading fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. 111 S & F extruded aluminium alloy handle, fabricated type, 100 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. 112 S & F cast aluminium alloy handle, cast type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. 113 S & F 75 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed. 114 Supply & fix sheet glass, ordinary quality, 3 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed. 115 M & L for 4 mm thick plain fibre cement flat sheets type B, any category as per IS 14862: 2000 (non-asbestos) building boards, fixed to timber/GI /Aluminium framework with screw in ceilings flat or sloping complete all as specified as directed. 116 M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and as directed. 117 M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed. 118 M & L for formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pilasters, buttresses, etc.; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed. 119 M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed. 120 M & L for mild steel TMT bars 5 mm dia and over, upto and including 10mm dia as in stirrups, spaces and binders bent to shape as required including cranking, bending and binding with mild steel wire (annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and directed. 121 Taking down plastering on lathing (other than wire-netting), without removing lathing, in cement lime or cement mortar (one side only measured in cases where both sides are plastered) complete all as specified and as directed. 122 Material and labour for plastering 10 mm thick on fair faces or the other side of lathing (on vertical surfaces) in cement mortar 1:4 finished even and fair without using extra cement and using water proofing compound @ 3% by weight of cement complete all as specified and as directed. Note: Water proofing compound shall be measured and paid seperately. 123 M&L for preparation of newly plastered surfaces on walls and applying three coats of white wash complete all as specified and as directed. 124 Preparation of old decorated surfaces on walls and applying two coats of white wash complete all as specified and as directed. 125 M & L for machine cut Kota stone slab flooring 20 to 25 mm thick over cement screed bed of 20 mm thick in cement mortar 1:3, laid and jointed with grey cement slurry, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. 126 M & L for 20 to 25 mm thick machine cut mirror polished Kota stone in risers of steps, skirting, dado and pillar laid on backing layer of 10 mm thick in cement mortar 1:4, laid and jointed, pointed with grey cement slurry, mixed with pigments to match the sheds including rubbing and polishing complete all as specified and directed. 127 M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. 128 Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out in soft/ loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and as directed. 129 M & L for cement concrete in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 130 S & F for steel work of grade-3 as per IS 10748 in tubular trusses including special shaped washer etc. complete using ERW or HRIW welded tubes conforming to IS 1161: 2014 (Yst 240 Grade) complete all as specified and directed. 131 S&F PVC gutter , Half Round, 180mm size complete all as specified and directed. 132 S&F Joint Bracket (with 2 clamps), 180mm for PVC pipes (half round) complete all as specified and directed. 133 S&F support Bracket, 180mm for PVC pipes (half round) complete all as specified and directed. 134 S&F running Outlet (with 2 clamps), 180mm for PVC pipes (half round) complete all as specified and directed. 135 S&F Stop End Outlet (with 1 clamp), 180mm for PVC pipes (half round) complete all as specified and directed. 136 S&F PVC Reducer, 180mmx110mm complete all as specified and directed. 137 S & F PVC (SWR) bends with inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed. 138 S & F hot rolled medium and high tensile structural steel of gradeFe 410-W (Gde E- 250)quality A conforming to IS 2062: 2011 as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed. 139 Excavating over areas not exceeding 1.5 m deep and getting out in soft/ loose soil complete all as specified and as directed. 140 M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. 141 M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings, floorings etc. all as specified and as directed. 142 M & L for cement concrete M15 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in flooring finished even and fair complete all as specified and as directed. 143 M & L for 15 mm thick cement plaster on fair faces of bricks/ concrete surfaces in cement mortar 1:6 including plastered surfaces shall be finished even & smooth without using extra cement all as specified and as directed. 144 Preparation of newly plastered surfaces on walls and applying two coats of white wash complete all as specified and as directed. 145 Removing excavated material (soils) exceeding 250 m but not exceeding 500 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. 146 M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 75 mm thick finished even and smooth without using extra cement complete all as specified and directed. 147 Providing and fixing factory made uPVG white colour Sliding window area exc 2.00 sqm, three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose. 148 Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed. 149 Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed. 150 M & L for preparing new plaster surfaces walls including chajjas, facias etc and filling of holes and flake out portion with appropriate quality putty and applying two coat of weather proof acrylic exterior paint (100% Acrylic) over a coat of alkali resistance primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed. 151 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. 152 M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC concealed conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk type pressed steel / welded MS terminal boxes made out of 1.20mm MS sheet, 3mm thick modular top cover for mounting of modular fittings, switches, sockets, regulators etc suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.Note:- Cutting chases and making good in CM (1:3) are deemed to be included in quoted rate. 153 M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC concealed conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 154 M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC concealed conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 155 M & L for concealed point wiring for one bell/ buzzer point controlled by one push button on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 156 M & L for point wiring for one light controlled by two 2-way switches complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC concealed conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.(Note: Cost of cutting chase and making good shall be included in the quoted rate.) 157 M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC concealed conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. Note: Cutting chases and making good to match with existing surfaces are deemed to be included in the quoted rate. 158 M & L for point wiring for one light or one fan or one exhaust fan or bell point controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including PVC casing caping of suitable size as required as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. 159 M & L for point wiring for one 3 pin/ 5 pin 6 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing caping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. 160 M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. 161 M & L for point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing caping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. 162 Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including taking down old sub main wiring complete all as specified and directed. Note - (i) Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length.(ii) Cutting chases and making good in cement mortar 1:3 are deemed to be included in the quoted rate. 163 M&L for switch piano (flush button type) single pole one way 5 Amps complete all as specified and directed. 164 S & F (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed. 165 S & F switch socket combination with (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 6 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. 166 S & F switch socket combination with (3 pin and 3 pin) having two earthing pins, combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A and neon indicator and fuse complete all as specified and as directed. 167 S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed. 168 S & F bell push, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. 169 S & F call bell, din dong, suitable for single phase, AC, 240 volts complete all as specified and as directed. 170 S&F in repair of building security light fittings 35 watts, minimum system lumen output 100 lumen/ watt, made up of pressure die cast housing with prismatic polycarbonate diffuser and individual LED with secondary optic and IP 65 including 40mm dia GI pipe of suitable length with nuts, bolts and clamps complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. 171 Taking down and refixing of serviceable LED batten complete all as specified and directed. 172 Supply and fixing 18 W LED light fitting wall mounted batten 4ft , extruded aluminium housing , enivromental friendly . heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt , 6000K including necessary connection complete all as specified and directed. 173 Supply and fixingLED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 174 S&F of lamp holder PVC polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. 175 S & F in repair LED Bulb 9/10 watts with high power LEDs as light source complete all as specified and as directed. 176 S & F in repair of vertical double door MCB Distribution board of sheet metal enclosure, triple pole and neutral, 4 way with 200 Amps rated bus bar, 415 volt, IP42 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 177 S & F in repair double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 12 way with 100 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 178 S&F MCB, SP, 240 volts, 6-32 Amps 10 KA, C Curve, complete all as specified and as directed. 179 S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 40 A-63A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. 180 S&F in repair MCB TPN 40- 100 Amp C series 10KA 415 volts complete all as specified and as directed. 181 S & F exhaust fan, AC, 50 Hz, single phase, 230 V, 300 mm sweep, 4 pole, heavy duty, metal body, 4 Nos blades, Insulation Class A, ISI marked including capacitor to ensure power factor more than 0.9 including louvers complete all as specified and as directed. 182 Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm with, blades, and frame and louvers including cutting/ enlargement of hole and giving proper finishing complete all as specified and directed. 183 Supplying, installing, testing & commissioning, Storage Geyser vertical, five star rated, 25 litres Capacity, ABS plastic body material, stainless steel inner tank material, shock proof, auto cut, on-off indicator, thermoplastic body, corrosion free with safety valve, fusible plug, thermal cut out including fixing by grouting and fastener complete all as specified and as directed. 184 M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 15 mm dia GI pipe light grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing including taking down old earthing complete all as specified and as directed. 185 Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories and fixed on walls and 2.5 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 2.5 sqmm cable, one run of 2.5 sqmm cable and one run of casing/capping shall be measured and paid as one unit length. 186 Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including heavy duty PVC casing caping of suitable size as required at site including all accessories and fixed on walls and 4 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 4 sqmm cable, one runf 4 sqmm cable and one run of casing caping shall be measured and paid as one unit length. 187 Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of casing/capping shall be measured and paid as one unit length. 188 S&F of building security light fittings 35 watts, minimum system lumen output 100 lumen/ watt, made up of pressure die cast housing with prismatic polycarbonate diffuser and individual LED with secondary optic and IP 65 including 40mm dia GI pipe of suitable length with nuts, bolts and clamps complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. 189 S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 12 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 190 Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. 191 Excavating in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and exceeding 1.5 m but not exceeding 3 m in depth and getting out in soft/ loose soil complete all as specified and as directed. 192 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. 193 Removing excavated material (excluding hard rock) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. 194 M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed. 195 Supplying & laying, in trenches 40 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 196 Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. Note :- Only punned down sand shall be measured. 197 M&L for bricks, common burnt clay building bricks, sub- class B designation 75 complete all as specified and directed. 198 Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. 199 S & F single door MCB Distribution board of sheet metal enclosure, single pole and neutral, 2 way with 100 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 200 S & F MCB SPN, 40 A, 240 V, 10 KAcomplete all as specified and as directed. 201 Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 6 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.