|
| 1 | Providing D.I. pipes (push on joints pressure pipes of D. I. of following class and diameters confirming to the I. S. specification inclusive cost of jointing materials (Rubber gasket of EPDM Quality ) excluding GST levied by GOI & GOM in all respect including Third party inspection charges of TPI Agency approved by MJP including Transit insurance, Railway Freight, Unloading from railway wagon, Loading into Truck, Transportation to departmental store, unloading, stacking etc. completed as directed by Engineer in charges (IS 1536/2001 for pipes and IS 158/1969 and IS 12820/1989 or latest edition/ revision with amendments for Rubber Gaskets. |
| 2 | a) 100 mm dia. |
| 3 | b) 150 mm dia. |
| 4 | Providing and supplying ISI standard CI /DI double flanged pipes excluding GST levied by GOI & GOM in all respect including railway freight, insurance, unloading from railway wagon, loading into truck transport to stores, unloading etc. complete as directed by Engineer-in-charge. |
| 5 | 150mm dia. |
| 6 | Lowering laying and jointing with SBR ruber gaskets C.I. /D.I , S/S pipes of various classes with CI / MS specials of following diameter in proper position, grade and alignment as directed by Engineer-in-charge including conveyance of material from stores to site of work, including cost of jointing materials and rubber rings labour etc. complete. |
| 7 | a) 150 mm dia. |
| 8 | Providing and supplying ISI standard D. I. specials & fitting with sealing rubber gasket of S.B.R, complete with cast iron follower gland and M. S. nut bolts coated or otherwise protected from rusting and suitable for D.I.pipes including cost of labour, materials, and transportation to stores / site, loading and unloading excluding GST levied by GOI & GOM in all respect, complete as per IS-9523. For all types of specials, bends tees etc. |
| 9 | a) 80 to 300mm dia. |
| 10 | Supply & fixing of C. I. Mechanical Compression Collar Coupling suitable for C. I. Spun Pipes ( as per - IS - 1536 /2001) and complete with sealing rubber gasket of SBR,.C.I. follower Glands and M.S. nut Bolts.The whole assembly should be mechanically and hydraulically tested to the provisions as laid down in IS:1538 /1993. |
| 11 | a)150 mm dia |
| 12 | Hydraulic testing of C.I./D.I. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position using water supplied by the contractor. |
| 13 | a) 150 mm dia. |
| 14 | D.I. Socket and flanged fittings :-Providing and supplying D.I. fitting with ISI mark socket pushon joints or flanged joints confirming to table 12 to 31 of IS 9523/2000 upto latest amendments including cost of SBR/ EDPM tyton rings. Fittings should be with internally ordinary portland cement mortor lined and externally metallic zinc coating/zinc rich paint with finishing layer of black bitumen coating including transportation & excluding all statutary duties and taxes such as GST levied by Gol and GoM in all respect etc. complete. |
| 15 | a) Double socket bend 90 degree- 150 mm dia. |
| 16 | b) Double socket bend 45 degree- 150 mm dia. |
| 17 | c) Double Socket Concentric Reducer 150* 100 mm |
| 18 | d) All Socket Tee -150*100 mm dia. |
| 19 | e) All Socket Tee -150*150 mm dia. |
| 20 | f) Double Socket Tee with Flange branch-PN-10150*150 mm dia. |
| 21 | g) Flange Socket-PN-10-150 mm dia. |
| 22 | h) Blank Flange -PN-1-150 mm dia. |
| 23 | i) All Flang TEE -PN-10 - 150*150 mm dia. |
| 24 | j) Plug - 150 mm dia. |
| 25 | Providing and supplying D.I. fittings with ISI mark Mechanical joint confirming to tables 12 to table 31 of IS 9523/2000 upto latest amendments including cost of SBR/ EDPM gaskets, Nuts, Bolts, Washers and Ductile iron follower glands. Fittings should be with internally Ordinary portland cement mortor lined and externally metallic zinc coating/zinc rich paint with finishing layer of black bitumen coating including transportation and excluding all statutary duties and taxes such as GST levied by Gol and GoM in all respect etc. complete. |
| 26 | a) MJ Collar/Coupling-100 mm dia. |
| 27 | b) MJ Collar/Coupling-150 mm dia. |
| 28 | Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, excluding GST lev-ied by GOI & GOM in all respect including inspec- tion charges, transport to departmental stores, unloading and stacking etc. complete as per IS-458/1988. |
| 29 | a) Class \"NP-IV\" -400 mm dia. |
| 30 | Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineer in- charge (For all class of pipes.) as per IS- 783-1985. |
| 31 | a) 400 mm dia. |
| 32 | Providing double flange sluice valveconfirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. |
| 33 | a) Sluice valve - PN - 1.6 (With by passarrangement) - 150 mm dia. |
| 34 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) |
| 35 | a) 150 mm dia. |
| 36 | Providing and supplying Air Valves as per IS-14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in allrespect etc. complete. |
| 37 | a) Air Valve Single Ball Flanged / ScrewedType-PN-1.6 - 50 mm dia. |
| 38 | Lowering, laying and fixing in proper alignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete. (for all class of valves). |
| 39 | a) Air Valve Double Ball (PN-1 and PN-1.6) - 50 mm |
| 40 | Cutting and champhering of pipes of following diameters including cost of all materials and labour involved, etc. complete as directed by Engineer-in-charge (for all class of pipes). |
| 41 | a) C.I. Pipes - 100 mm dia. |
| 42 | b) C.I. Pipes - 150 mm dia. |
| 43 | Valve Chamber with Precast RCC Covers Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B.masonry in CM 1:5 proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge |
| 44 | a) As above of 1.2 x 1.2 M internal size and depth upto 1.2 M with precast R.C.C slab cover. |
| 45 | Making cross connection to existing distribution main of any type including excavation, breaking and removing existing pipes, lowering, laying of specials and pipes in their position, refilling, closing the water supply in that area, dewatering and restarting the water supply, etc. complete as directed by Engineer-in-charge for following diameters of existing pipeline, irrespective of diameter of branch line. (The number of joints involved will be paid separately depending upon the nature of joints and required pipes, valves and specials will be supplied free of cost at stores.) |
| 46 | a) 100 mm dia. |
| 47 | b) 150 mm dia. |
| 48 | Removable mechanism type Bulk water meter as per ISO 4064 Providing, installing and giving satisfactory field testing of bulk water meter,horizontal inferential multijet type with magnetic drive and dry dial suitable for ambient 50º C Temperature duly sealed against tampering complete with flanges at both ends and conforming to class B as per ISO 4064 along with manufacturer\"s test certificate and guarantee certificate, including cost of all materials and labour etc with OIML. MID certification forAbroad meter and FCRI for India including 36 months guaranteeetc complete. |
| 49 | a) 150 mm |
| 50 | C.I. Strainer \"T\" (Basket) Typewith flanged ends Providing, and fixing C.I.Strainer for water meters including cost of all material and labour. of \"T\" (Basket) Type with flanged ends and with stainless steel or brass mesh with openings of 2.5. mmto 3 mm and suitable for operating pressure of 16 Kg./cm2 and test pressure of 24 Kg./cm21 |
| 51 | a) 150 mm |
| 52 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 1/259) |
| 53 | Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259) |
| 54 | a) Lift 0 to 1.5 M |
| 55 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt roadincluding removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 4/259) |
| 56 | a) Lift 0 to 1.5 M |
| 57 | Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means. (Bd-A-6/259) |
| 58 | a) Lift 0 to 1.5 M |
| 59 | Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete.(Bd-A-9/261) |
| 60 | Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc.complete. |
| 61 | Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting,etc. complete.(Bd-A-12/264) |
| 62 | Providing structural steel work in single stanchions composed of RSJ, channel, etc. with caps, bases, mild steel plates, angles, brackets, cleats, gusset plates, anchor bolts, etc. as per detailed design and drawing or as directed by Engineerincharge including cutting, fabrication, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc. complete. (Bd C-6/277) |
| 63 | Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules;including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) |
| 64 | a) Tor Steel |
| 65 | Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags/cum) |
| 66 | a) In PCC M-150 |
| 67 | Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)-- |
| 68 | a) In RCC M-300 |
| 69 | b) Hire charges of machineries - Rent for JCB |
| 70 | Manufacturing, providing and supplying spirally welded / ERW/ SAW / fabricated M. S. pipes (Commercial Quality) including procurements of plates, gas cutting torequried size rolling, tack welding assembling in suitable lengths to form pipes, welding on automatic welding machine and forming ‘V’ edge on both ends of pipes including railway freight, insurance, unloading from railway wagon, loading into truck, transport to stores, unloading, stacking excluding GST levied by GOI & GOM in all respect, etc, complete as per IS - 3589 and IS-5504 as applicable as per specifications (No negative toleranceinthicknessispermissible). |
| 71 | a) DiaofPipe:219.10mm(O.D.) Thicknessofpipe:- 4.8 mm |
| 72 | Lowering and laying of MS pipe in position to correct line and level including M. S. specials such as distance pieces, straps, bends, tapers, etc. on pedestals or chairs upon piers or trestles. The rate to include loading, unloading, hoisting, marginal cutting wherever required, assembling and tack welding, and includingtransportation upto 500 m. etc.complete as specified. |
| 73 | a) 5 mm to 8 mm thick ( Upto 250 mm. dia.) |
| 74 | Welding in all positions with required number of runs, for M. S. pipes internally and / or externally including gauging wherever necessary, fixing appurtenances and other accessories in connection with pipe laying work as per specification. |
| 75 | a) 10 mm dia. |